• Title/Summary/Keyword: 음향진단

Search Result 228, Processing Time 0.03 seconds

Prosthetic restoration of the patient with inaccurate pronunciation after prosthesis fabrication through systematic diagnosis and treatment procedure: A case report (보철물 제작 후 부정확한 발음을 가진 환자에서 체계적인 진단 및 치료과정을 통한 보철 수복 증례)

  • Choi, Yu-Sung;Lee, Seong-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.413-422
    • /
    • 2016
  • Recently, there are cases where anterior esthetic prostheses are fabricated for better esthetics, but biologic, mechanical factors could be overlooked, too focusing on esthetic factor. This leads to changes in neutral zone, dentition, position of tongue and lips, occlusion and anterior guidance causing inaccurate pronunciation. Therefore, consideration of systematic diagnosis and treatment procedure are required. In this case, prosthesis was refabricated through a systematic diagnosis and treatment procedure using four factor (acoustic analysis, esthetic analysis, occlusion, neutral zone) for the patient who complained of inaccurate pronunciation and esthetics of the fixed prosthesis fabricated 10 years ago. Thus, by promoting functional, esthetic recovery, this case report demonstrates satisfying results to both the patient and dentist.

A Study on Efficient Fault-Diagnosis for Multistage Interconnection Networks (다단 상호 연결 네트워크를 위한 효율적인 고장 진단에 관한 연구)

  • Bae, Sung-Hwan;Kim, Dae-Ik;Lee, Sang-Tae;Chon, Byoung-SIl
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.5
    • /
    • pp.73-81
    • /
    • 1996
  • In multiprocessor systems with multiple processors and memories, efficient communication between processors and memories is critical for high performance. Various types of multistage networks have been proposed. The economic feasibility and the improvements in both computing throughput and fault tolerance/diagnosis have been some of the most important factors in the development of these computer systems. In this paper, we present an efficient algorithm for the diagnosis of generalized cube interconnection networks with a fan-in/fan-out of 2. Also, using the assumed fault model present total fault diagnosis by generating suitable fault-detection and fault-location test sets for link stuck fault, switching element fault in direct/cross states, including broadcast diagnosis methods based on some basic properties or generalized cube interconnection networks. Finally, we illustrate some example.

  • PDF

A New Loose Parts Monitoring Technique for Nuclear Steam Supply System based on High Resolution Sensor Array Signal Processing (고해상도 센서어레이 신호처리법을 이용한 원자력발전소 핵증기 공급계통의 새로운 금속파편 진단기법)

  • Rhee, Ill-Keun;Choi, Jae-Won
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.6
    • /
    • pp.76-84
    • /
    • 1997
  • Loose parts monitoring system(LPMS), which is used to detect metallic loose parts in the nuclear power plant, plays an important role in safe and reliable operation of the plant. To prevent from the damage due to the loose parts, most domestic nuclear power plants are using, or planning to use LPMS. However, these LPMS's, which are all invented from overseas and thereby depend on the oversea technologies, are very expensive, and are known to be inefficient to diagnose loose parts due to the lack of fundamental know-how of LPMS. Therefore, the main purpose of this paper is to propose and to realize a new loose parts localization algorithm which is simple and efficient enough even for the inexperienced operators to diagnose loose parts accurately and promptly. Considering practical nuclear power plant circumstances, some simulations for estimating the loose parts location have been done. The results show that the proposed method, called a modified circle intersection method, performs high resolved loose parts localization with 3.4% of error.

  • PDF

Contrast Improvement in Diagnostic Ultrasound Strain Imaging Using Globally Uniform Stretching (진단용 초음파 변형률 영상에서 전역 균일 신장에 의한 콘트라스트 향상)

  • Kwon, Sung-Jae;Jeong, Mok-Kun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.8
    • /
    • pp.504-508
    • /
    • 2010
  • In conventional diagnostic ultrasound strain imaging, when displaying strain image on a monitor, human visual characteristics are utilized such that hard regions are displayed as dark and soft regions are displayed as bright. Thus, hard regions representing tumor or cancer are displayed as dark, decreasing the contrast inside the lesion. Because the lesion area is stiff and thus displayed as dark, a method of inverting the image brightness and thereby increasing the contrast in the lesion for better diagnostic purposes is proposed wherein a postcompression signal is extended in the time domain by a factor corresponding to the reciprocal of the amount of the applied compression using a technique termed globally uniform stretching. Experiments were carried out to verify the proposed method on an ultrasound elasticity phantom with radio-frequency data acquired from a diagnostic ultrasound clinical scanner. It is found that the new method improves the contrast-to-noise ratio by a factor of up to about 1.8 compared to a conventional strain imaging method that employs a reversed gray color map without globally uniform stretching.

Acoustic Emission Signal Analysis for Damage Assessment of the Reinforced Concrete Slab Structures (철근 콘크리트 슬래브 구조 손상 평가를 위한 음향방출 신호분석)

  • Kim, Jeong-Hee;Han, Byeong-Hee;Seo, Dae-Cheol;Yoon, Dong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.360-367
    • /
    • 2009
  • The acoustic emission(AE) behavior of reinforced concrete slab under flexural loading was investigated to assess the integrity. This study was aimed at identifying the characteristics of AE response associated with damage development. By applying cyclic loading in various load steps, it was able to differentiate each AE source such as distributed micro crack initiation, friction, flexural crack and localized diagonal tension crack. The secondary peak and the change of AE hit rate gave valuable criteria fur assessment. From the analysis of the felicity ratio, furthermore, it was shown that this values can be used for evaluating the degree of concrete damage. Based on the experimental results, this approach for practical AE application may provide a promising method for estimating the level of damage and distress in concrete structures.

Diagnosis of Micro-Calcified Lesions of Breast Tissue Phantoms Using Acoustic Resonance Coupled with Power Doppler (공명현상과 파워도플러를 이용한 유방조직 팬텀의 미세 석회화 병변 진단)

  • Kim, Jeong-Koo;Ha, Myeung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.80-86
    • /
    • 2008
  • Breast ultrasound has many advantages over mammography but suffers from a shortcoming of being not suitable in detecting microcalcification. We studied on a method based on acoustic resonance and power Doppler to detect calcification of breast tissue using a typical 7.5 MHz linear probe used in breast ultrasound examination. We first constructed a breast tissue phantom made of gelatin and then observed calcified legions as external vibrations varied. Calcification injected to the breast tissue phantom being resonated different from the surrounding medium, and its acoustic resonance driven by external vibrations was visualized by differences for color brightness and area in ROI of power doppler. In low frequency regions, the acoustic resonance almost not appeared and showed a plateau in $300{\sim}600\;Hz$ and the color vanished as the frequency further increased.

Diagnosis of Valve Internal Leakage for Ship Piping System using Acoustic Emission Signal-based Machine Learning Approach (선박용 밸브의 내부 누설 진단을 위한 음향방출신호의 머신러닝 기법 적용 연구)

  • Lee, Jung-Hyung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.1
    • /
    • pp.184-192
    • /
    • 2022
  • Valve internal leakage is caused by damage to the internal parts of the valve, resulting in accidents and shutdowns of the piping system. This study investigated the possibility of a real-time leak detection method using the acoustic emission (AE) signal generated from the piping system during the internal leakage of a butterfly valve. Datasets of raw time-domain AE signals were collected and postprocessed for each operation mode of the valve in a systematic manner to develop a data-driven model for the detection and classification of internal leakage, by applying machine learning algorithms. The aim of this study was to determine whether it is possible to treat leak detection as a classification problem by applying two classification algorithms: support vector machine (SVM) and convolutional neural network (CNN). The results showed different performances for the algorithms and datasets used. The SVM-based binary classification models, based on feature extraction of data, achieved an overall accuracy of 83% to 90%, while in the case of a multiple classification model, the accuracy was reduced to 66%. By contrast, the CNN-based classification model achieved an accuracy of 99.85%, which is superior to those of any other models based on the SVM algorithm. The results revealed that the SVM classification model requires effective feature extraction of the AE signals to improve the accuracy of multi-class classification. Moreover, the CNN-based classification can be a promising approach to detect both leakage and valve opening as long as the performance of the processor does not degrade.

Study on the Comparison of Piezoelectric Property of Acoustic Sensor for Valve Leak Diagnosis (밸브누설 진단용 PZT 및 Pb-Free 음향센서의 압전특성 비교 연구)

  • Lee, Sang-Guk;Park, Sung-Keun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3383-3388
    • /
    • 2007
  • To compare the sensor performance of AE leak diagnosis system which can measure valve leak conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured on valve of the simulated test system for power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, pressure difference, valve size and fluid using both piezoelectric acoustic emission sensor and Pb-Free acoustic emission sensor. The results of this study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve.

  • PDF

Hoarse Speech Analysis Using Dissymmetric Four-Mass Model of Vocal Cords (비대칭 4 질량 성대 모델에 의한 쉰목소리 분석)

  • Jiang, Gan-Yi;Chen, Hui-Fang;Choi, Tae-Young
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.5
    • /
    • pp.94-101
    • /
    • 1995
  • In this paper, a new vocal cords model, called a four-mass model, is proposed for a hoarse speech mechanism. Pathological changes of vocal cords cause hoarse speech and glottal waveform reflects motion states of vocal cords. From these facts, we assumed that the morbid vocal cords be dissymmetric and take the four-mass type. The glottal waveforms and the model parameters of normal and hoarse speech signals are analyzed, and some relations bet ween the model parameters and the hoarse pathology are discussed. Experimental results show that the new research method of hoarse speech can reveal relations between the acoustic features of hoarse speech and the hoarse pathology, and be used to diagnose laryngeal diseases and to improve tone quality of hoarse speech.

  • PDF

A Study on an Ultrasonic Circular Array Transducer for Intra-vascular Ultra-sound Diagnosis (혈관 내부 진단용 원형 배열 초음파 트랜스듀서에 대한 연구)

  • 김희원;이수성;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.4
    • /
    • pp.329-336
    • /
    • 2003
  • Intra-Vascular Ultra-Sound (IVUS) transducers were developed for the application to diagnose coronary diseases. The transducer consists of 32 piezoelectric elements with a front insulation layer and a polymeric acoustic backing layer on a hollow alumina tube. The optimal geometrical structure of the transducer was designed through theoretical analysis of radiation patterns of the transducer. Samples of the IVUS transducers of the diameter of 3㎜ were fabricated to illustrate the design scheme. For the piezoelectric elements, 2-2 mode piezocomposite materials were employed. Experimental performance of the transducers showed good agreement with the design results, which verified feasibility of the transducer for IVUS applications.