• Title/Summary/Keyword: 음이온 교환 수지

Search Result 147, Processing Time 0.027 seconds

Coulometric Determination of Plutonium in PWR Spent Fuels (PWR 사용후핵연료내 플루토늄의 전기량적 정량)

  • Sohn, Se Chul;Suh, Moo Yul;Kim, Jung Suk;Song, Byung Chul;Jee, Kwang Yong;Choi,In Kyu;Kim, Won Ho
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.6
    • /
    • pp.581-586
    • /
    • 2000
  • Separation and coulometric titration method were applied for the determination of plutonium content in samples of PWR spent fuel. Plutonium was separated on an anion exchange(AG MP-1) column and determined by the controlled-potential coulometric titration. In this study, we discussed some experimental conditions related to the separation and determination of plutonium in PWR spent fuel samples. Average accuracy(recovery of plutonium) for the determination of 0.230∼3.02 mg plutonium standard was 99.36%. Average precision(relative standard deviation, RSD) for the determination of 0.250∼0.450 mg plutonium in PWR spent fuel samples was 0.38%.

  • PDF

Direct determination of gadolinium in urania-gadolinia nuclear fuels by inductively coupled plasma atomic emission spectrometry (유도결합플라스마 원자방출분광법을 이용한 UO2-Gd2O3 핵연료 중 가돌리늄 분석)

  • Choi, Kwang-Soon;Suh, Moo-Yul;Lee, Chang-Heon;Han, Sun-Ho;Jee, Kwang-Yong
    • Analytical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.131-137
    • /
    • 2007
  • The urania-gadolinia fuels were dissolved with nitric acid. The analytical conditions of ICP-AES for the direct determinations of gadolinium in the uranium matrices without separation process were investigated. Based on the effect of uranium on gadolinium intensity, the best wavelength for gadolinium was 336.223 nm. The relative deviation of two methods, direct and indirect measurements with anion exchange chromatography, was less than 5 %. Therefore it was possible for this procedure directly to measure 5~10 wt.% of gadolinium in urania-gadolinia fuels without separation by ICP-AES.

Solid Bases as Racemization Catalyst for Lipase-catalyzed Dynamic Kinetic Resolution of Naproxen 2,2,2-Trifluoroethyl Thioester (리파아제에 의한 나프록센 2,2,2-트리플로로에틸 씨오에스터의 Dynamic Kinetic Resolution을 위한 라세미화 촉매로서의 고체 염기)

  • 김상범;원기훈;문상진;김광제;박홍우
    • KSBB Journal
    • /
    • v.19 no.3
    • /
    • pp.215-220
    • /
    • 2004
  • A variety of solid bases such as inorganic bases, basic anion exchange resins, and resin-bound bases were tested as a catalyst for racemization of (S)-naproxen 2,2,2-trifluoroethyl thioester in isooctane at 45$^{\circ}C$. Among the various bases, DIAIOM WA30, which is a weakly basic anion exchange resin with a tertiary amine based on a highly porous type styrene-divinylbenzene copolymer, showed the highest catalytic activity. The second-order interconversion constant of DIAION WA30 was 8.6${\times}$10$\^$-4/ mM$\^$-1/h$\^$-1/ and about 3 times higher than that of trioctylamine under the same conditions. The rate of DIAION WA30-catalyzed racemization decreased with increasing an amount of water added to the reaction medium. Lipase-catalyzed kinetic resolution of racemic naproxen 2,2,2-trifluoroethyl thioester was successfully carried out under in situ racemization of substrate with DIAION WA30 in isooctane at 45$^{\circ}C$. More than 60% conversion and 99% enantiomeric excess for the desired (S)-naproxen product were obtained. Furthermore, such a solid base catalyst could be easily separated and reused in contrast to trioctylamine.

Selective Separation of $^{59/63}Ni$ from Radioactive Wastes (방사성 폐기물 내 $^{59/63}Ni$의 선택적 분리)

  • Lee Chang-Heon;Jung Kie-Chul;Choi Kwang-Soon;Jee Kwang-Yong;Kim Won-Ho
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.121-128
    • /
    • 2005
  • A study on the selective separation of $^{99}Tc,\;^{94}Nb,\;^{55}Fe,\;^{90}Sr$ and $^{59}Ni(^{63}Ni)$ from various radioactive wastes discharged from the nuclear power plants in Korea is being performed for use in their quantifications which are indispensible for the evaluation of the radionuclide inventory. Separation behaviour of Ce, Ca, Mg, Al, Cr, Ti, Mn and Cu recovered along with Ni during the separation of Re (as a surrogate of $^{99}Tc$), Nb, Fe and Sr by anion exchange and Sr-Spec extraction chromatography was investigated by cation exchange and Ni-Spec extraction chromatography using synthetic radioactive waste dissolved solutions containing matrix elements such as Re, Nb, Fe, Sr, Ni, B, Na, K, Ce, Co, Ca, Mg, Al, Zn, Cr, Pb, Cd, Mo, Mn, Cu, Zr, Ti and U. To purify the Ni fraction recovered and prepare a radionuclide source available for gas proportional counting, an application of the Ni precipitation procedure with dimethylglyoxime in the medium of ammonium citrate and tartaric acid solutions as a masking agent for co-existing metal ions was described in detail.

  • PDF

Ion-Exchange Chromatography of Some Toxic Heavy Metal Ions (인체유해 중금속이온의 이온교환 크로마토그라피)

  • Lee, Dai Woon;Yu, Euy Kyung
    • 한국해양학회지
    • /
    • v.10 no.1
    • /
    • pp.33-40
    • /
    • 1975
  • The ion exchange sorption and elution behavior of toxic heavy metal ions, such as Hg(II) and Zn(II), have been studied in aqueous and methanolic media of MCl (M: K, Na and NH$\_$4/). The ion exchange resins studied are Dowex 1-X8, Cl$\^$-/ (50-100 or 200-400 mesh) and Dowex 50W-X8, M$\^$+/ form (M: K, Na, NH$\_$4/ and H). the sorption and elution of metal ion on the resin is largely due to the formation of the anionic chlororocomplex of metal ion. The addition of methanol in the medium contributes markedly to the distribution data. In order to apply this work for the treatment of polluted sea water with toxic heavy metal ions, removal experiment of the metal ions from the synthetic sample solution was investigated.

  • PDF

Introduction of Denitrification Method for Nitrogen and Oxygen Stable Isotopes (δ15N-NO3 and δ18O-NO3) in Nitrate and Case Study for Tracing Nitrogen Source (탈질미생물을 이용한 질산성 질소의 산소 및 질소 동위원소 분석법 소개)

  • Lim, Bo-La;Kim, Min-Seob;Yoon, Suk-Hee;Park, Jaeseon;Park, Hyunwoo;Chung, Hyen-Mi;Choi, Jong-Woo
    • Korean Journal of Ecology and Environment
    • /
    • v.50 no.4
    • /
    • pp.459-469
    • /
    • 2017
  • Nitrogen (N) loading from domestic, agricultural and industrial sources can lead to excessive growth of macrophytes or phytoplankton in aquatic environment. Many studies have used stable isotope ratios to identify anthropogenic nitrogen in aquatic systems as a useful method for studying nitrogen cycle. In this study to evaluate the precision and accuracy of denitrification bacteria method (Pseudomonas chlororaphis ssp. Aureofaciens ($ATCC^{(R)}$ 13985)), three reference (IAEA-NO-3 (Potassium nitrate $KNO_3$), USGS34 (Potassium nitrate $KNO_3$), USGS35 (Sodium nitrate $KNO_3$)) were analyzed 5 times repeatedly. Measured the ${\delta}^{15}N-NO_3$ and ${\delta}^{18}O-NO_3$ values of IAEA-NO-3, USGS 34 and USGS35 were ${\delta}^{15}N:4.7{\pm}0.1$${\delta}^{18}O:25.6{\pm}0.5$‰, ${\delta}^{15}N:-1.8{\pm}0.1$${\delta}^{18}O:-27.8{\pm}0.4$‰, and ${\delta}^{15}N:2.7{\pm}0.2$${\delta}^{18}O:57.5{\pm}0.7$‰, respectively, which are within recommended values of analytical uncertainties. Also, we investigated isotope values of potential nitrogen source (soil, synthetic fertilizer and organic-animal manures) and temporal patterns of ${\delta}^{15}N-NO_3$ and ${\delta}^{18}O-NO_3$ values in river samples during from May to December. ${\delta}^{15}N-NO_3$ and ${\delta}^{18}O-NO_3$ values are enriched in December suggesting that organic-animal manures should be one of the main N sources in those areas. The current study clarifies the reliability of denitrification bacteria method and the usefulness of stable isotopic techniques to trace the anthropogenic nitrogen source in freshwater ecosystem.

A Study on Optimization for Separation of Phenols and Preconcentration-Separation of Trace Phenols in Reversed-Phase Liquid Chromatography (역상 액체 크로마토그래피에서 페놀류의 분리 최적화 및 미량 페놀류의 농축-분리에 관한 연구)

  • Lee Dai Woon;Lee Sung Won;So, Min Jeong;Cho Byung Yun
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.5
    • /
    • pp.513-522
    • /
    • 1993
  • The purpose of this study is to optimize the selectivity of mobile phase solvents for separation of 25 phenols in reversed phase liquid chromatography and to accomplish the simultaneous preconcentration and separation of trace phenols from water samples. Phenols used in this study were classified into three groups, chloro-, methyl-, and nitrophenols. Quaternary solvent mobile phases were employed to improve the selectivity. Overlapping resolution maps(ORM) as a statistical simplex techniques was used to predict the optimum solvent system. Additional criterion such as pH and temperature were also investigated. In order to improve the resolution and decrease the analysis time, isoselective multisolvent gradient elution system was employed with ORM-Prism method. The simultaneous preconcentration and separation of trace phenols from water samples were performed by using XAD-2/Dowex 1-X8 tandem column. When the extraction efficiency was evaluated by sampling up to 1 L of distilled water, recovery of the phenols, except phenol, was above 90% and the limit of detection of the phenols was 5 ppb. The XAD-2/Dowex 1-X8 method was superior to C18 cartridge in terms of recovery and selectivity.

  • PDF

A Study on the Development of Analytical Methods and Behaviors of Environmental Pollutants(III) : On-Line System for Preconcentration and Separation of Trace Phenols by HPLC (환경 오염물질의 정량법 개발과 거동에 관한 연구(III) : 미량 페놀류의 HPLC 정량을 위한 온 라인 농축)

  • Lee, Dai Woon;Kim, Jin Young;Park, Young Hun;Moon, Myeong Hee
    • Analytical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.33-39
    • /
    • 1994
  • The purpose on this study was to develop a new improved chromatographic method for determination of trace phenols from environmental waste water. The research was carried out with selected 8 phenols, and solid-phase extraction was employed as sample pretreatment method. The coupling of XAD-4 and Dowex $1{\times}8$ resin as preconcentration column increased the selectivities toward interferences coexisted in matrix. Automation was accomplished with on-line process of pretreatment and HPLC system. After elution of sample through XAD-4 column, phenols were adsorbed by dispersion force, then displaced from it by ACN basified, simultaneously and selectively readsorbed via anion exchange on Dowex $1{\times}8$. Dowex $1{\times}8$ column was washed by water. Phenols readsorbed were removed from Dowex $1{\times}8$ column by a minimum volumn of methanol containing HCl. Each pretreatment step was connected by switching valves and the eluate was directly on-line injected to obtain fast and reliable results into the HPLC. Recovery of phenols was greater than 90%. To examine utility of this method, analysis of phenols from laboratory waste water sample which was added some organic pollutants to find with phenols on environmental waste water were also accomplished without their interference effects.

  • PDF

Determination of 129I in simulated radioactive wastes using distillation technique (증류법을 이용한 모의 방사성폐기물 중 129I 의 정량)

  • Choi, Ke-Chon;Song, Byung-Cheol;Han, Sun-Ho;Park, Yong-Joon;Song, Kyu-Seok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.3
    • /
    • pp.141-148
    • /
    • 2011
  • It is clarified in the radioactive waste transfer regulation that the concentration of radioactive waste for the major radio nuclide has to be examined when radioactive waste is guided to the radioactive waste stores. In case of the low level radioactive waste sample, the analytical results of radioactive waste concentration frequently show a value lower than minimum detectable activity (MDA). Since the MDA value basically depends on the amount of a sample, background value, measurement time, counting efficiency, and etc, it would be necessary to increase a sample amount with a intention of minimizing MDA. In order to measure a concentration of $^{129}I$ in low and medium level radioactive waste, $^{129}I$ was collected by using a distillation technique after leaching the simulated radioactive waste sample with a non-volatile acid. The recovery of $^{129}I$ measured was compared with that measured with column elution technique which is a conventional method using an anion-exchange resin. The recovery of inactive iodide by using the distillation method and column elution were found as $86.5{\pm}0.9%$ and $87.3{\pm}2.7%$, respectively. The recovery and MDA value calculated for distillation technique when 100 g of extracted solution of $^{129}I$ was taken, were found to be $84.6{\pm}1.6%$ and $1.2{\times}10^{-4}Bq/g$, respectively. Consequently, the proposed technique with simplified process lowered the MDA value more than 10 times compared to the column elution technique that has a disadvantage of limited sampling amount.

Copper Isotope Measurements Using a Neptune MC-ICP-MS (다검출기 유도결합 플라즈마 질량분석기를 이용한 구리 동위원소 분석법)

  • Park, Sanghee;Ryu, Jong-Sik;Shin, Hyung Seon;Kil, Youngwoo;Jo, Yunsoo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.221-227
    • /
    • 2016
  • Copper is an essential transition metal involving in various biogeochemical processes. With the recent advances in analytical techniques and mass spectrometry, such as MC-ICP-MS, it is possible to measure Cu isotopes, which allows us to understand various biogeochemical processes in detail. Nonetheless, few studies have been performed in South Korea. In this study, we compared two purification methods previously reported using an anion exchange resin ($AG^{(R)}$ MP-1M), developed the best method in our lab environment, and then verified it by measuring Cu isotopic compositions in two USGS geological reference materials (BHVO-2 and BIR-1a). Although all matrix cations causing mass bias were effectively removed through both two methods with the yield of better than 95%, the method using the mixture of HCl and $H_2O_2$ only displays Cu isotopic compositions, in excellent agreement with reported values within the error. The method developed in this study is expected to be commonly applied to earth and environmental sciences.