The Assessment of Water Quality Contamination Following the Utilization of Coal Ash as Fill Material (성토재로서 석탄회 사용에 따른 수질오염도 평가)

  • 김학삼;조삼덕
    • Geotechnical Engineering
    • /
    • v.11 no.3
    • /
    • pp.5-16
    • /
    • 1995
  • In this paper, two leaching tests(batch test & column test) were carried out to estimate the detrimental effects of coal ash leachates. The variation of constituents and concentration of coal ash leachate with the lapse of leachins time was analysed through the column tests. From the test results, it was found coal tach can be classified as a general waste, and all other items except pH of coal ash leachate are satisfied the concentration requirements for the drinking water. It was also found the concentration of coal ash rapidly decrease with the lapse of the leaching time and become the insignificant value after an elapsed time.

  • PDF

Development of Real-time Groundwater Quality Monitoring and Advanced Groundwater Purification Technology for Groundwater using Photoinduced Reactive Oxygen Species (지하수 수질 실시간 모니터링 및 광유도 활성산소를 이용한 고도수처리 기술)

  • Kang-Kyun Wang;Byung-Woo Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.15-15
    • /
    • 2023
  • 2020년 기준 국내 상수도 보급률은 99.1% 차지하고 있으며(환경부, 2019), 수도관리차원에서 수돗물은 먹는 물로 시판되어질 만큼 우수한 관리체계를 유지하고 있다. 그 반면에 지하수는 생활용수, 식품가공, 농·축산, 양어, 군부대를 비롯한 전국지역에서 연간 10억 8천만톤 용수를 소비하고 있음에도 (환겨례 신문, 2013; 환경부, 2019) 사용되는 지하수의 약 65%가 음용수 불가판정을 받았으며, 최근 지하수의 오염비율은 급격히 증가하는 추세이다. 특히, 지하수관정의 관리부주의에 의한 수질오염 및 수인성 다제내성균(슈퍼박테리아) 등에 의한 오염사례가 국내는 물론, 국제적으로 다수 보고되고 있는 실정이다 (환경부, 2013). 현재 지하수 수질관리는 공공기관 및 지자체 지정기관을 통해 진행되고 있으며, 검사기간은 수질채취로부터 통상 7~15일정도 소요되어 수질 관리 및 기준, 검사주기에 대한 애로가 많다. 현장 지하수관정에서 실시간 수질을 모니터링하고 이에 연동된 자동 수처리 시스템의 개발 및 도입은 나날이 심각해지는 환경오염 상황에서 선제적 예방과 해결방법으로 중요한 요소기술이다. 현재 지하수오염 및 부적합 음용의 수질처리는 화학약품, 필터여과, UV살균, O3 (플라즈마)을 이용하는 것이 대표적이나, 화학약품의 경우 2차 오염이나 식품 세척 및 가공에 있어 부적합성의 한계점이 있다. 필터여과의 대표적인 RO필터의 경우 약 50% 순손실이 발생하고, UV 살균의 경우 UV에 의한 사용관리자의 위험 및 장비의 광부식 문제, O3 의 경우 고압전류 사용에 따른 위험성 등의 한계점이 나타나고 있다. 지하수 수질정화를 위한 광유도 활성산소(1O2, ·O-2)는 광감응제에 가시광의 빛 조사를 통해 생성되는 활성산소로의 에너지 및 전자 전이가 동시 진행되어 단일항 산소(1O2)와 슈퍼옥사이드 이온(·O-2)을 생성하게 된다. 생성된 활성산소는 유해미생물 또는 유기화학물과 개열, 제거, 치환 반응 등을 통해 미생물사멸 및 유해화학물질들이 분해 가능하다. 이를 이용한 지하수 유해미생물 사멸기술, 장비, 실시간 지하수의 분석기술 및 정수처리, 지하수 물순환 시스템 개발뿐만 아니라 지하수 음용수 및 오염개선, 지하수 기저유출에 의한 오염원 저감으로부터 지류·지천, 하천 본류 수질개선 등의 대상지역에 활용 가능하다. 또한 광유도 활성산소는 기존 상수도 수처리에 있어 오존(O3) 처리와 이산화티탄을 이용한 AOP과정을 단일처리 공정으로, 기존 O3 의 특성상 확산 거리가 매우 길어 사람을 포함한 생체 내에 유입 시 다양한 부작용 발생과 O3 차폐시설 요구의 문제점 극복의 대안으로 환경 및 인체에 무해한 광유도 활성산소 시스템을 적극적으로 도입 및 적용해야 한다. 본 연구 목적은 정류상태 흡광분광기술을 이용한 실시간 수질 모니터링과 광유도 활성산소를 이용한 유해 미생물의 멸균효능 및 지하수 수질관리 기술로의 적용 가능성을 제시하고자 한다.

  • PDF

팩카그라우팅 공법을 이용한 지표하부 오염방지 시공 및 응용 연구

  • 조희남;성익환;이병대;조병욱
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.77-81
    • /
    • 2003
  • 일반세균, 질산성질소, 탁도로 오염된 지하수 관정의 2개공에 대해 수질개선을 시행하였다. 그 결과 2개공 모두 음용수 기준에 적합한 수질개선 효과를 가질 수 있음으로 하여 수질오염 발생의 주요 요인 중의 하나가 지하수 지표하부 오염방지 시설인 그라우팅이 부실함으로써 기인함을 규명할 수 있었다. 따라서, 본 연구를 통해 수질이 오염된 지하수 관정의 수질개선이 가능하다는 확인은 물론 또한, 지하수 관정내 지표수의 유입을 방지하기 위해서 지하수 상부오염방지 시설의 설치가 적극적으로 추진되어야 할 것이다. 지하수 오염을 예방하기 위해서는 지하수 개발 단계에서부터 지하수 지표하부 오염방지 시설이 연암 암반층까지 견실하게 적용되어져야 한다는 것을 확인할 수 있었다.

  • PDF

수도직결 겸용 저수조 급수방식

  • 박정범
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.30 no.3
    • /
    • pp.15-20
    • /
    • 2001
  • 음용수에 대한 세계 각국의 기준과 현행 급수방식중 수도직결 겸용 저수조 급수방식 적용의 필요성 및 현황, 수질 개선방법과 관리지침을 중심으로 기술한다.

  • PDF

The Characteristics of Drinking Groundwater Quality in Daejeon reclamation (대전광역시 음용지하수 수질의 특성)

  • Han, Woon Woo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.2 no.3
    • /
    • pp.37-45
    • /
    • 2001
  • The characteristics of drinking groundwater quality was analyzed by investigating observed data during 1995-1997 in Daejeon city. As the analysis of observed data, the 30.1% of them were over the drinking water quality standards in Daejeon city and the unfit ratios of each region were 36.4% at Dong-Gu, 32.3% Daedeog-Gu, 31.2% Jung-Gu, 30.0% Seo-Gu and 25.2% at Yusoung-Gu. It was found that the items over the drinking water quality standards were 24 items and all of the mean concentration of water quality items were under the drinking water quality standard except Fe and Mn in 1997. The mean concentration of Fe was $1.31mg/{\ell}$ over the water quality at Daedeog-Gu and that of Mn was $0.53mg/{\ell}$ at Jung-Gu. The concentrations of $NH_3$-N, Mn, Fe, Al and F were increased rapidly in 1997, so that the cause of increasing also must be examined closely. It was found that the rainfall and unfit ratio(unfit frequency/test frequency) of E-coli and bacteria had the hydrologic persistance. The coefficient of correlation between them was 0.525. On the rainfall over 100mm, it was 0.673 and on the rainfall over 150mm, it was 0.641. The correlation between E-coli and rainfall was higher than that between bacteria and rainfall.

  • PDF

Study on the Characteristics of Dalgi Mineral Water in Cheongsong (청송 달기약수의 수질특성에 관한 연구)

  • Lee, Sung-Ho
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.3
    • /
    • pp.220-228
    • /
    • 2000
  • This study deals with the water qualities of Dalgi mineral spring in Cheongsong district.Water samples which were taken from upper, middle and bottorn spring sites were tested for twenty eight important water quality items including minerals, essential and/or toxic trace elements, and the analytical items to affect the taste of mineral water, seasonally from May 1999 to February 2000 The results obtained wereas follows:Each spring site showed much difference in major items. Bottom spring water showed higher value of Mg and Na than others. Middle spring water showed the highest value in all of the items except Mg and Na. The concentration of Hardness, Fe and Mn in mineral water were over than the normal standard for drinking water, but these items are not specified for the mineral water. As, Cd, $Cr^{6+}$ and Hg were not found and Pb was found ln trace level. All of the items proved nearly constant during the four seasons except water temperature. The contribution of mineral water to the nutrition of human was calculated in order to investigate the health effect of drinking water on the bases of Required Daily Allowance,one liter of water drinking and the mineral concentration of the bottom spring. The percentage of consumable minerals of Ca, Mg, Na, K, Mn,Zn and Fe were 35.05,36.43,5.88∼10.63,0.19∼0.57,21.86∼43.72,0.65, and 95.l respectively. This means Dalgl mineral water is pIenty of iron mineral. The K and O indexes of mineraI water appeared to be good for healthy and delicious water.

  • PDF

지하수 개발에 따른 자료 획득 및 이용에 관한 연구

  • Son Ju-Hyeong;Jeong Sang-Yong;Kim Sun-Yeong;Park Sang-Ju;Gwon Sun-Gyu
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.90-93
    • /
    • 2005
  • 경상남도 합천군과 창녕군 생활용수 지하수 관정 개발시 지하수 굴착공종으로부터 얻어진 구간별 지층자료와 대수층 수질 자료를 획득하여 이용하는 방법을 연구하였다. 지층정보를 파악하기 위하여 지하수공 굴착심도 10m마다 슬라임을 채취하였으며, 대수층 관통시에 지하수 시료를 구간별로 채수하여 전기전도도 및 수질시료를 분석하였다. 경도가 높은 지역의 경우, 음용수 수질기준치에 적합한 지하수를 개발하기 위해서 대수층별 전기전도도를 분석측정하여 경도를 간접적으로 파악함으로써 지하수 굴착심도 결정에 이용하였다. 그리고 대수층 구간별 불소 농도를 파악하였으며, 불소 농도가 높은 대수층 구간에서는 하부대수층 메움 등을 실시하였다. 대수층의 수질검사결과에서 기준치를 초과하는 우려 인자들(불소, 경도, 증발잔류물, 질산성 질소, 철, 알루미늄, 아연 등)에 대한 수질기준 초과 가능성을 대비한 양수시험 모니터링을 설계함으로써 지하수공의 수질 특성 파악이 가능하였다. 양수시험과정에서 탁도가 시간에 따라 기준치 이하까지 감소하는 일반적인 경향과 기준치 이상에서 더 이상 감소하지 않는 경향에 대한 원인을 분석할 수 있었다.

  • PDF

Fluoride and nitrate removal by electro-coagulation for decentralized water treatment plants (전기응집을 이용한 소규모 수도시설의 불소 및 질산성질소 이온의 제거)

  • Han, Song-Hee;Chang, In-Soung;Back, Soun-Ok;Joung, Seun-Young;Lee, Cheol-Ku
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11a
    • /
    • pp.115-116
    • /
    • 2010
  • 광역상수도의 경우 수자원공사 및 지방상수도 사업자들에 의해 전문적으로 수질을 관리하고 음용수를 보급하고 있으나 소규모 수도시설의 경우 전문능력을 갖춘 관리자가 아닌 마을의 대표자가 맡아 관리함에 따라 안정성 및 유지관리의 어려움이 자주 제기되고 있다.[1] 또한 소규모 수도시설의 경우 취수원으로 지하수나 계곡수를 이용하여 여과나 염소소독을 거쳐 음용수로 이용함에 따라 중금속 및 무기이온 등 각종 오염물질이 효과적으로 제거되지 않아 이를 사용하는 주민들이 불편함을 겪고 있는 실정이다. 환경부의 법정 수질 검사에 따르면 부적합 판정을 받은 곳의 대부분은 마을상수도와 소규모 급수시설인 것으로 나타났으며 초과 항목으로는 무기이온 중 특히 불소와 질산성질소 인 것으로 나타났다.[2] 이러한 문제점을 해결하고자 기존의 고도 정수처리 시설인 막여과, 오존처리, 활성탄 흡착 공정 등을[3-5] 적용하고 있으나 소규모 수도시설에 적용하기에는 유지관리, 규모, 경제적 측면 등 여러 한계점을 지니고 있다. 따라서 본 연구에서는 이러한 문제점을 해결하기 위한 방안으로 전기응집기술을 이용하여 음용수 수질기준을 초과하는 무기이온 중 불소와 질산성 질소를 제거하고자 하였다. 전기응집기술은 제거효율이 높고, 운전이 용이하며 부가적인 화학약품의 첨가가 불필요하다.[6,7] 또한 기존의 고도정수처리 기술에 비해 전기응집 공정은 처리효율과 경제적인 측면 모두를 만족시키고 있어 소규모 수도시설의 불소와 질산성질소를 효과적으로 제거할 수 있는 방안으로 판단된다. 본 연구에 사용된 실험장치는 직류전원공급장치 (DC power supply), 반응조, 전극으로 구성되어 있다. 직류전원공급장치는 최대전압 30 Volt, 최대 전류 30 Amper 까지 조절 가능하였으며 반응조의 크기는 14.5cm(w) ${\times}$ 9cm(L) ${\times}$ 22cm(H) 이고 실용적 1.5L이다. 반응조의 상부에는 전극이 고정될 수 있도록 0.5cm 간격의 홈을 만들어 제작 하였다. 전극은 가용성 전극인 알루미늄 (Al), 스테인레스스틸(SUS304)를 이용하였다. 이를 통해 전류밀도, 전극간격 등의 변수를 두어 최적의 전기응집 운전 조건을 파악하였으며 이는 소규모 수도시설의 수질개선 향상에 도움이 될 수 있을 것으로 판단된다.

  • PDF

The Effects of Timber Harvesting on Soil Chemical Ingredients and Stream Water Quality (성숙임목수확벌채가 토양의 화학성분과 계류수질에 미치는 영향)

  • 박재현;우보명;김우룡;안현철;김재수
    • The Korean Journal of Ecology
    • /
    • v.23 no.1
    • /
    • pp.9-15
    • /
    • 2000
  • The effects of clearcutting on soil chemical ingredients and stream water quality have been investigated at a natural deciduous forest catchment within the Seoul National University Research Forest in Mt. Paekun, Chunnam province during the periods of 1993 to 1998. Soil chemical ingredients and stream water qualities were monitored at a 13 ha clearcutting site and a non-treatment site nearby. During the first and second years after harvesting, the levels of total-N, and exchangeable ions (K/sup +/, Na/sup +/, Ca/sup 2+/, Mg/sup 2+/) decreased compared to the values of before harvesting. During the fifth years after harvesting, these levels were significantly higher than those during the first and second years after harvesting. But the chemical characteristics of soil were not changed at all. pH of water in the harvesting area was 6.5 in stream water. Among the nutrients, Cd, Pb, Cu, and phosphate were not found, and the level of BOD reached at the level of the domestic use suitable for drinking. Turbidity, odor, taste, NH/sub 4//sup +/ -N, NO/sub 3//sup -/-N, standard plate count, and coliform were also low enough to be used as the domestic use for drinking by the near villagers. During the first and second years after harvesting, BOD increased to about 1 ppm. For that reason, the harvesting planning should be built in the harvesting area in consideration of the control of water quality in the stream.

  • PDF

Risk Assessment of Groundwater Used for Washing GAP-certified Agricultural Crops after Harvest (GAP 농산물의 수확 후 처리에 사용되는 지하수의 위해성평가)

  • Kim, Hwang-Yong;Paik, Min-Kyoung;Kim, Areumnuri;Lee, Dong Gyu;Jeong, Mihye;Kim, Won-Il;Oh, Jin-A;Kim, Se-Ri;Hong, Su-Myeong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.6
    • /
    • pp.551-556
    • /
    • 2019
  • Recently, due to the fact that the mineral content in the wash water of the GAP-certified melon exceeds the GAP wash water standards, there are cases where the certification cannot be maintained. Therefore, agricultural industry demand requesting relaxation of the inorganic elements standard for water quality has been increasing, taking into account the consumption characteristics of Korean melon, which is eaten after removing the peel. This study was conducted to evaluate the human risks of four inorganic materials (fluorine, arsenic, iron and manganese) based on the water quality data of 142 samples of groundwater that was used for washing GAP-certified Korean melon in Seongju area from 2017 to 2019. As a result, the HQ of four minerals in Koreans who consumed groundwater used for washing GAP-certified Korean melons in the Seongju area was below 0.10 on average. In particular, in the case of iron and manganese which are esthetic influence substances, the average HQ was 0.00. The overexposure group showed 0.01, which was lower than the HQ (average 0.01, overexposure group 0.03) of the group that consumed Korean melon. Based on all the results, even if the groundwater of the Seongju area is used to wash GAP-certified Korean melon, the impact from these four inorganic materials, including iron and manganese, for Korean population consuming Korean melon will be minimal.