• Title/Summary/Keyword: 음압 레벨

Search Result 184, Processing Time 0.022 seconds

A Study on the Effect by Receiving Points as Measuring Floor Impact Sound (바닥충격음 측정 시 수음점 위치의 영향에 관한 연구)

  • Chung, J.Y.;Lee, S.H.;Jeong, G.C.;Oh, Y.K.;Joo, M.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.283-286
    • /
    • 2005
  • This study measures the levels of various receiving points for reducing deviations the floor impact sound. According to the results, 63-125Hz band appeals the large deviations. Among the spacial points, the spot of 0.75m from the wall correspond with the average of all spots. The KS stipulates that the receiving point should be off the wall more than 0.5m But obeying the rules, the large deviation appears. So, this study shows that the adequate receiving point is 0.75m from the wall.

  • PDF

Comparison of Rating Methods for the Floor Impact Sound Insulation Performance (바닥충격음 차단성능 평가방법의 상호비교)

  • Kim, Kyoung-Woo;Choi, Hyun-Jung;Yang, Kwan-Seop;Lee, Seung-Eon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.291-294
    • /
    • 2005
  • In this study, we compared and analyzed the floor impact sound insulation performance produced by the rating methods. The rating methods are using reversed A-weighting curve, A-weighted sound pressure levels and arithmetic average. On-site floor impact sound pressure levels of living room and room are measured. The results of this study are 1)the rating using reversed A-weighting curve for heavy-weight impact sound's standard deviation is lower than that of light-weight impact sound, 2)the number of rating using A-weighted sound pressure levels and arithmetic average is larger than that of using reversed A-weighting curve, and 3)the number of rating using reversed A-weighting curve mainly depends on impact sound pressure level of 63Hz in heavy-weight impact sound.

  • PDF

Design of Acoustic Resonator Array for Low Frequency Mode Control of Launch Vehicle (위성 발사체 탑재부 저주파 음향 모드 제어를 위한 공명기 배치 설계)

  • Seo, Sang-Hyun;Park, Soon-Hong;Jang, Young-Soon;Yi, Yeong-Moo;Cho, Gwang-Rae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.521-524
    • /
    • 2005
  • To protect a satellite and electronic equipment from the acoustic loads generated by rocket propulsion system, many launch vehicle use acoustic blanket. Most high frequency region of the acoustic loads is reduced by nose fairing skins and acoustic barrier, but low frequency region is not. In order to control low frequency acoustic mode, we designed away resonator panel which was made of composite materials. This paper shows the absorption coefficient measurement result of resonator and SPL(Sound Pressure Level) reduction by using resonators in a rectangular cavity for experiment. Proper arrangement of acoustic resonators at each mode reduce effectively SPL around the satellite through changing boundary condition.

  • PDF

The vibration and noise characteristic analysis of the BLDC Axial-gap type motor by using Finite Element Method (FEM 을 이용한 BLDC Axial-gap type 전동기의 진동과 소음 특성 분석)

  • Lee, Taeck-Jin;Park, Jun-Hong;Lee, Sang-Ho;Hong, Jung-Pyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.943-946
    • /
    • 2007
  • The vibration and noise characteristic of the Axial-gap motor for an air conditioner were analyzed. Experimental Modal Analysis was performed to understand the vibration characteristic of the motor. The noise of motor was measured in a dead room. Finite Element Method was performed to find the vibration characteristic of the motor by using ABAQUS program.

  • PDF

Numerical Investigation of Performance Characteristics for Cooling Tower Axial Fans with Sweep (스윕을 가진 냉각탑용 축류홴의 성능 특성에 관한 수치해석적 연구)

  • Oh, K.J.
    • Journal of Power System Engineering
    • /
    • v.13 no.4
    • /
    • pp.31-37
    • /
    • 2009
  • The purpose of this numerical study was to investigate performance characteristics for cooling tower axial fans with sweep. Performance data for the fans with various sweep angles were obtained in terms of the setting angle at a constant flow rate. Viscous flow calculations were carried out to obtain Performance data of the total pressure rise and hydraulic efficiency. A solution of the Ffowcs Williams-Hawkings equations was used to calculate the sound pressure level at three times fan diameter away from the fan. The calculated performance data well represented performance characteristics of the cooling tower axial fan. The total pressure rise and hydraulic efficiency at the same setting angle decreased with sweep angle. Sound pressure level slightly decreased for the fan with a sweep angle of 10 degree. No significant effect of the sweep geometry was found on the sound pressure level.

  • PDF

Auditory Perception Experiment on Attribute of Road Traffic Noise Causing Annoyance with Identical Linear Sound Pressure Level (동일한 선형 음압 레벨의 도로교통소음의 성가심 유발 인자에 관한 연구)

  • An, Jang-Ho;Schang, Seo-Il;Ko, J.H.;Chun, Hyung-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.641-648
    • /
    • 2006
  • This study investigates which sound quality indices except SPL raise annoyance response. For investigation, auditory perception experiments for road traffic noise with identical linear SPL were performed by Paired Comparison Method. The numerical results of a Paired Comparison experiment express relative preference about annoyance. So that these relative preference scores are to be correlated to sound quality indices, which are absolute, a transformation is required to go from the relative domain to an absolute and linear scale of preference. The results of the transformation will be the 'merit values,' which quantifies the annoyance(in this case) of the road traffic noise on a linear scale. Using multiple regression, a formula is established that can calculate predicted merit values. Furthermore, This investigation offers a method selecting sound samples that represent various sound quality indices values to use experiment.

  • PDF

Comparison of Rating Methods for the Floor Impact Noise (바닥충격음 평가방법 중 단일수치평가량과 dB(A) 비교)

  • Park, Cheol-Yong;Jang, Dong-Woon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.612-615
    • /
    • 2006
  • In this study, we compared and analyzed the floor impact noise insulation performance produced by the rating methods. The rating methods are using reversed A-weighting curve, A-weighted sound pressure levels(dB(A)). The results of this study are(1)dB(A) by the specified frequency is 0.5dB(A) at light weight and 2.5dB(A) at heavy weight upper than all pass dB(A)(2)the rating using reversed A-weighting curve is 5dB lower than dB(A)(3)the number of rating using reversed A-weighting curve mainly depends on impact noise pressure level of 63Hz in heavy weight but dB(A) does not.

  • PDF

A experimental study for the characteristics of impulse noise caused by shooting of K-7 silenced assault rifle (K-7소음총의 사격음 특성에 대한 실험적 연구)

  • Lee Jin-Ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.4 s.19
    • /
    • pp.36-43
    • /
    • 2004
  • In 1909 Hiram P. Maxim invented one of the first metal silencers for reducing sound levels in firearms. Silenced me have been mainly applied in the hunting and military operation. In particular special force make use of silenced rifle because it is low sound level. This paper considers experimental analysis for the characteristics of shock wave caused by shooting of a silenced me. Experimental results Indicate that the sound level of K-7 silenced rifle was lower than the sound level of MP5 silenced rifle. And, Sound Power Level of K-7 silenced rifle at a distance more than 75m or loom have nearly the constant value. This results that suggested the characteristics data about K-7 rifle's impulse noise will be apply to design the silencer of a small arms.

Pass by Noise Test Site Variability

  • Kim Byoung Sam
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.3
    • /
    • pp.116-121
    • /
    • 2005
  • The objective of this paper is to compare the site-to-site variability of ISO 10844 pass by the noise test sites. In order to investigate the site-to-site variance of test surfaces, European commercial tires are tested at seven different test sites. Three Korea test sites and four Europe test sites are selected. The pass by noise test is done according to a 2001/43/EC regulation. Although the ISO surface has a very specific track composition, it does not reduce the variation of pass by noise measurements over the surface of test sites. This paper shows that the test results of pass by noise level are different depending on the test sites. The correlation obtained in this work is able to predict the pass by noise level for certain test site using the data measured from another test site. The prediction value is range with an error within 1dB(A).

A Study on Reduction of Sound Noise Induced by Disk Rotation in Optical Disk Drives (광 디스크 드라이브의 공력소음 감소에 관한 연구)

  • 송인상;박건순;최학현;김수경;이승엽
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.693-702
    • /
    • 1999
  • We study the characteristics of airflow and sound noise induced by disk rotation in optical disk drives. The characteristics of airflow around a rotating disk surrounded by various tray structures are numerically investigated using a commercial CFD program and then compared with experimental results. Sound pressure and intensity caused by the fluid-structure interactions in the CD/DVD-ROM drive are measured, and the effect of the ariflow on the sound noise and disk vibration is discussed. In order to reduce airflow-induced noise and vibration around the rotating disk, tray geometry is modified. Both numerical and experimental studies implemented with different tray models show that the improved tray model alters the characteristics of the disk-induced airflow, causing the reduction of the airflow-induced sound level.

  • PDF