• Title/Summary/Keyword: 음성 구동

Search Result 66, Processing Time 0.026 seconds

Design of a tracking and demodulation circuit for wideband DDMA in IMT-2000 (IMT-2000 광대역 CDMA의 동기추적 및 데이터 복조 회로구현)

  • 권형철;오현서;이재호;조경록
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.6A
    • /
    • pp.871-880
    • /
    • 1999
  • In this paper, a pseudo-noise(PN) tracking and demodulation circuits are analyzed and designed for a direct-sequence/spread-spectrum multiple access system under a mobile fading channel. We consider noncoherent delay locked loop(DLL) as a PN code tracking loop which has 1/8 PN chip resolution. The tracking performance of DLL is evaluated in terms of locking time from a loose state and tracking jitter. The received signal is demodulated to original data by despreading with PN code locked by DLL. Also the designed circuit supports sound service of 32Kbps and in-band signal with 4.096MHz chip clock. The circuits are implemented and verified with FPGA, which is shown completely data recovery under AWGN 7dB and will be available for IMT-2000.

  • PDF

Evaluation of Word Recognition System For Mobile Telephone (이동전화를 위한 단어 인식기의 성능평가)

  • Kim Min-Jung;Hwang Cheol-Jun;Chung Ho-Youl;Chung Hyun-Yeol
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.92-95
    • /
    • 1999
  • 본 논문에서는 음성에 의해 구동되는 이동천화를 구현하기 위한 기초 실험으로서, 이동전화상에서 많이 사용되는 단어 데이터를 직접 채록하여 단어 인식 실험을 수행하여 인식기의 성능을 평가하였다. 인식 실험에 사용된 단어 데이터베이스는 서울 화자 360명(남성화자 180명, 여성화자 180명), 41상도 화자 240명(남성화자 120명, 여성화자 120명)으로 구성된 600명의 발성을 이용하여 구성하였다. 발성 단어는 이동전화에 주로 사용되는 중요 기능과 제어 단어, 그리고 숫자음을 포함한 55개 단어로 구성되었으며, 각 화자가 3회씩 발성하였다. 데이터의 채집환경은 잡음이 다소 있는 사무실환경이며, 샘플링율은 8kHz였다. 인식의 기본단위는 48개의 유사음소단위(Phoneme Like Unit : PLU)를 사용하였으며, 정적 특징으로 멜켑스트럼과 동적 특징으로 회귀계수를 특징 파라미터로 사용하였다. 인식실험에서는 OPDP(One Pass Dynamic Programming)알고리즘을 사용하였다. 인식실험을 위한 모델은 각 지역에 따라 학습을 수행한 모델과, 지역에 상관없이 학습한 모델을 만들었으며, 기존의 16Htz의 초기 모델에 8kHz로 채집된 데이터를 적응화시키는 방법을 이용하여 학습을 수행하였다. 인식실험에 있어서는 각 지역별 모델과 지역에 관계없이 학습한 모델에 대하여, 각 지역별로, 그리고 지역에 관계없이 평가용 데이터로 인식실험을 수행하였다 인식실험 결과, $90\%$이상의 비교적 높은 인식률을 얻어 인식시스템 성능의 유효성을 확인할 수 있었다.

  • PDF

Development of the hybrid-type ultrasound speaker (하이브리드형 초음파 스피커 개발)

  • Lee, Hyoung-Sang;Kim, Bok-Kyu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.3
    • /
    • pp.247-253
    • /
    • 2021
  • Directional ultrasonic speakers that are used to hear sound only in a specific area have been continuously researched on various improvements in terms of sound quality and cost compared to general speakers. In this paper, we propose a DSP based hybrid-type ultrasonic speaker that can be heard at the same time as a general speaker in order to compensate for the sound in the low-band range, considering that it is difficult to hear the low-band sound below 500 Hz due to the sensor characteristics of the ultrasonic speaker. In the case of the system that is implemented by simply connecting a general speaker and an ultrasonic speaker, there are issues of high cost and difficulties of control as two amplifiers are used to playback ultrasonic and general sound sources. In addition, sound quality deteriorates due to the difference in playback time between ultrasonic and general sound sources. In order to improve issues of cost, control and sound quality, we developed hybrid-type ultrasonic speaker with a DSP based amplifier that can simultaneously playback by synchronizing the general sound source with the regenerated ultrasonic sound source, in addition to implement the existing CODEC functions such as Dynamic Range Control (DRC) and Equalizer (EQ).

An Experimental Study on the Effect of Capillary Pressure on the Void Formation in Resin Transfer Molding Process (수지이동 성형공정에서 기공형성에 미치는 모세관압의 영향에 관한 실험적 연구)

  • 이종훈;김세훈;김성우;이기준
    • The Korean Journal of Rheology
    • /
    • v.10 no.4
    • /
    • pp.185-194
    • /
    • 1998
  • Flow-induced voids during resin impregnation and poor fiber wetting give serious effects on the mechanical properties of composites in resin transfer molding process. In order to better understand the characteristics of resin flow and to investigate the mechanism of void formation, flow visualization experiment for the resin impregnation was carried out on plain weaving glass fiber mats using silicon oils with various viscosity values. The permeability and the capillary pressure for the fiber mats of different porosities were obtained by measuring the penetration length of the resin with time and with various injection pressure. At low porosity and low operating pressure, the capillary pressure played a significant role in impregnation process. Video-assisted microscopy was used in taking the magnified photograph of the flow front of the resin to investigate the effect of the capillary pressure on the void formation. The results showed that the voids were formed easily when the capillary pressure was relatively high. No voids were detected above the critical capillary number of 2.75$\times$$10^{-3}, and below the critical number the void content increased exponentially with decrease of the capillary number. The content of void formed was independent of the viscosity of the resin. For a given capillary number, the void content reduced with the lower porosity of the fiber mat.

  • PDF

A Study of Inter-observer Agreements of Spiral Chest Computed Tomography in Diagnosing Pulmonary Embolism (폐색전증에서 나선형 컴퓨터 전산화 단층촬영의 관찰자간의 일치도에 관한 연구)

  • Kim, Yang-Ki;Lee, Young Mok;Kim, Ki-up;Uh, Soo-taek;Kim, Yong Hoon;Park, Choon Sik;Hwang, Jung-Hwa;Kim, Dong Hun;Goo, Dong-Erk;Choi, Deuk-Lin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.5
    • /
    • pp.473-479
    • /
    • 2005
  • Background : A pulmonary embolism often presents with nonspecific symptoms and signs. However, a delayed diagnosis can result in catastrophic outcome. The majority of preventable deaths associated with a pulmonary embolism can be ascribed to a missed diagnosis rather than to the failure of existing treatments. Therefore, accurate and rapid diagnostic methods are essential for the management of a pulmonary embolism. The recent generation of multidetector-row spiral CT scanners appears to outperform other imaging modalities in detecting a central and peripheral pulmonary embolism. However, there are some variations in the interpretations of the findings between observers. This study examined the inter-observer differences of the diagnoses in patients with a pulmonary embolism. Method : 64 patients who were diagnosed with a pulmonary embolism either clinically or with spiral chest CT from 2002 to 2004, were included. Two thoracic radiologists interpreted the multidetector-row spiral CT in terms of the diagnosis of a pulmonary embolism and the location of the thrombus independently. Among 64 patients, 14 patients were excluded because there was no evidence of a pulmonary embolism or there was different interpretation of the pulmonary embolism between radiologists. A clinical diagnosis was based on "Rules for predicting the probability of embolism". Results : The mean score of the patients according to the Wells method was $3.91{\pm}0.30$ (0-9). The accordance of the radiologists was 95% in the main, 85% in the lobar, 91.2% in the segmental, and 96% in the sub-segmental pulmonary arteries. After excluding the negative interpretation from both radiologists, their agreement was 76.2%(${\kappa}.$ 0.83) in the main, 57.6%(${\kappa}.$ 0.63) in the lobar, 51.5%(${\kappa}.$ 0.63) in the segmental, and 34.6%(${\kappa}.$ 0.49) in the sub-segmental pulmonary arteries. Conclusion : Chest CT has been recently applied to patients suspected of having a pulmonary embolism. It was found that spiral CT is a rapid test for diagnosing a thrombus, and there was reliable accordance between the observers from the area of the large pulmonary arteries. However, there was a lack of agreement between the observers in diagnosing thrombi located distal to the sub-segmental arteries.

Comparison of apical sealing ability of continuous wave of obturation technique using EndoTwinn and System B (EndoTwinn과 System B continuous wave of obturation units를 이용한 근단부 근관충전 효율비교)

  • Shin, Hyun-Ju;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.522-529
    • /
    • 2007
  • The purpose of this study was to compare the apical leakage of the root canal filled with the System B and the EndoTwinn(the combined application of heat and ultrasonic vibration). Sixty extracted premolars with straight root were cleaned and shaped to size 35. Group SB was obturated using System B and Group ET was filled with EndoTwinn. A size 35 of 0.06 tapered gutta-percha and Adseal were used and the plugger which could be introduced to 4 mm short of working length was selected in the obturation procedure. As the positive control, Group PC was not filled. In Group SB, ET and PC, all external surfaces of each tooth were coated with nail varnish leaving only 1 mm area around the apical foramen. In the negative control of Group NSB and Group NET, all of external tooth surface including apical foramen was coated with the nail varnish. The specimens were immersed in methylene blue dye solution for 2 days. Then the specimens were sectioned at each 1 mm from apex to 5 mm level. The final score of one specimen was given by summing up of the points at all levels. The dye leakage of Group ET was significantly less than that observed in Group SB (p < 0.05). And the frequency of gutta-percha pulling out from root canal when the plugger was removed was more often with the System B than with EndoTwinn but there was no significant difference.