• Title/Summary/Keyword: 유효가압면적

Search Result 4, Processing Time 0.016 seconds

The Development of Uniform Pressurizing System for Extremely Large Area UV-NIL (극대면적 UV-NIL 공정에서의 균일 가압 시스템 개발)

  • Choi, Won-Ho;Shin, Yoon-Hyuk;Yeo, Min-Ku;Yim, Hong-Jae;Sin, Dong-Hun;Jang, Si-Youl;Jeong, Jay-Il;Lee, Kee-Sung;Lim, Si-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1917-1921
    • /
    • 2008
  • Ultraviolet-nanoimprint lithography (UV-NIL) is promising technology for cost effectively defining micro/nano scale structure at room temperature and low pressure. In addition, this technology is fascinating because of it's possibility for high-throughput patterning without complex processes. However, to acquire good micro/nano patterns using this technology, there are some challenges such as uniformity and fidelity of patterns, etc. In this paper, we have focused on uniform contact mechanism and performed contact mechanics analysis. The dimension of the flexible sheet to get adequate uniform contact area has been obtained from contact mechanics simulation. Based on this analysis, we have made a uniform pressurizing device and confirmed its uniform pressurized zone using a pressure sensing paper.

  • PDF

Numerical Analysis on Flow Characteristics in the Pressurized Air Supply Smoke Control System (급기가압 제연설비의 내부 유동특성에 대한 수치해석)

  • Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.52-58
    • /
    • 2017
  • This study investigated the pressure difference distribution and the flow characteristics among room, ancillary room, and stair case by carrying out the numerical simulations on the air flow inside the pressurized air supply smoke control system. Numerical simulations were conducted to analyze pressure and velocity distribution of compartments by pressurized air supply for the air-leakage test facility which was built to measure the effective leakage area. In this study, the leakage of air was considered by locating the narrow slit onto fire door and window of room. Simulated results using this method precisely followed the previous experimental results for the pressure differences between the stair case and ancillary room. Predicted results showed that the local leakage of air rarely affected the overall flow pattern and pressure distribution. Although the average velocity over the door between room and ancillary room satisfied the regulation for fire safety, it was certified the unsafe outflow to ancillary room could be occurred in the local position such as the upper part of the door.

Numerical Simulation on Smoke Movement in Multi-Compartment Enclosure Fires under Pressurized Air Supply Conditions (급기가압 조건에서 복합 구획 공간 화재의 연기 거동에 대한 수치해석 연구)

  • Ko, Gwon Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.15-21
    • /
    • 2018
  • This study examined the flow characteristics of fire smoke under pressurized air ventilation conditions by carrying out fire simulations on multi-compartment enclosure, including room, ancillary room and stair case. Fire simulations were conducted for the air-leakage test facility, which was constructed to measure the effective leakage area and aimed to improve the understandings of fire and smoke movement by analyzing the overall behaviors of fire smoke flow and pressure distributions of each compartment. The simulation results showed that the heat release rate of the fires was controlled sensitively by the amount of air supplied by the ventilation system. An analysis of the velocity distributions between the room and ancillary room showed that fire smoke could be leaked to the ancillary room through the upper layer of the door, even under pressurized air supply conditions. From these results, it was confirmed that the fire size and spatial characteristics should be considered for the design and application of a smoke control system by a pressurized air supply.

Characteristics of heat transfer and bubble around horizontal tube in a fluidized bed heat exchanger (유동층 열교환기의 수평관에서 열전달 및 기포특성)

  • 김성원;안정렬;김상돈
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2000.11a
    • /
    • pp.97-100
    • /
    • 2000
  • 유동층 열교환기 (Fluidized Bed Heat Exchanger; FBHE) 는 온도 균일성이라는 유동층의 특징을 이용하여 적당한 전열면적을 갖는 열교환관을 층 내 설치하여 일정한 양의 열을 전열시키는 것으로, 최근 순환유동층 연소로의 scale-up 을 통한 열용량 증대와 함께 고온의 재순환물질로부터 열을 회수, 연소로의 온도제어 및 열회수율의 극대화를 얻고자 재순환부에 연결하여 사용하고 있다. 또한, 가압순환유동층의 개발과 더불어 유효열전달 면적의 증대를 통한 상대적인 연소로 소형화를 위해 채택되고 있다. 특히, 유동층 열교환기는 전체 공정에서 20-60% 의 열을 회수할 수 있어, 열전달에 있어 매우 중요한 역할을 차지한다.(중략)

  • PDF