• Title/Summary/Keyword: 유전체장벽

Search Result 99, Processing Time 0.032 seconds

The Characteristics of Ozone Generation for Dielectric Barrier Discharge with Discharge Area variation (방전면적에 따른 유전체장벽 방전에 의한 오존생성 특성)

  • Lee, Chang-Ho;Park, Soong-Gyu;Kim, Jong-Hyun;Lee, Hyun-Chul;Song, Hyun-Jig;Lee, Sang-Keun;Park, Won-Zoo;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.379-380
    • /
    • 2008
  • Recently, ozone is utilized in various fields and its needs are expanding. In this paper, glass and ceramic plate tyre ozonizer have been fabricated to investigate discharge parameter(input power, flow rate of supplied gas, electrode form, etc.) effect to discharge. And the conditions of discharge parameter have been investigated for optimum ozone generation. Ozone concentration is continuously increased with increasing input power for same discharge space, and ozone yield is also increased until maximum point after that it is saturated. Ozone concentration is inversely proportional to flow rate of supplied gas but ozone generation and ozone vield characteristics are improved.

  • PDF

The Dielectric Barrier micro-hollow cathode structure and its upper pD limitation in alternative current driving for flat panel light source (광원을 위한 AC구동 유전체장벽 미세공음극 구조와 상한 pd 제한조건)

  • Park K. W.;Lee T. I.;Jegal J. P.;Baik H. K.
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.45-47
    • /
    • 2005
  • The Dielectric Barrier micro-hollow cathode structure and it's upper pD limitation are investigated for determining of optimum hollow cathode discharge condition. In experiment, discharge is sustained by AC diriving and investigated gas is pure Xe. From Experiment, Optimum pD range is lower than 0.72 torr.cm at pure Xe and Cu cathode.

  • PDF

Flow Control using DBD Plasma on Backward-facing Step (DBD 플라즈마를 이용한 후향계단 아음속 유동 제어)

  • Song, Ji-Woon;Park, Sul-Ki;Kim, Tae-Hwan;Cho, Hyung-Hee
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.433-436
    • /
    • 2011
  • The effect of plasma on flow characteristics in subsonic flow in backward-facing step is studied. The velocty of main flows are 0.5 m/s. DBD plasma is using for flow control. Stainless foil and polymide films are used as an electrode and dielectric material. The change of flow characteristics are shown by different of plasma generation region in fluid flow.

  • PDF

Performance Improvement of Dielectric Barrier Plasma Reactor for Advanced Oxidation Process (고급산화공정용 유전체 장벽 플라즈마 반응기의 성능 개선)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.459-466
    • /
    • 2012
  • In order to improved treatment performance of dielectric barrier discharge (DBD) plasma, plasm + UV process and gas-liquid mixing method has been investigated. This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical). The basic DBD plasma reactor of this study consisted of a plasma reactor (consist of quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode), air and power supply system. Improvement of plasma reactor was done by the combined basic plasma reactor with the UV process, adapt of gas-liquid mixer. The effect of UV power of plasma + UV process (0~10 W), gas-liquid mixing existence and type of mixer, air flow rate (1~6 L/min), range of diffuser pore size (16~$160{\mu}m$), water circulation rate (2.8~9.4 L/min) and UV power of improved plasma + UV process (0~10 W) were evaluated. The experimental results showed that RNO degradation of optimum plasma + UV process was 7.36% higher than that of the basic plasma reactor. It was observed that the RNO decomposition of gas-liquid mixing method was higher than that of the plasma + UV process. Performance for RNO degradation with gas-liquid mixing method lie in: gas-liquid mixing type > pump type > basic reactor. RNO degradation of improved reactor which is adapted gas-liquid mixer of diffuser type showed increase of 17.42% removal efficiency. The optimum air flow rate, range of diffuser pore size and water circulation rate for the RNO degradation at improved reactor system were 4 L/min, 40~$100{\mu}m$ and 6.9 L/min, respectively. Synergistic effect of gas-liquid mixing plasma + UV process was found to be insignificant.

Effect of plasma treatment using underwater non-thermal dielectric barrier discharge to remove antibiotics added to fish farm effluent (양식장 배출수에 첨가된 항생제 제거 위한 수중 비열 유전체장벽 방전 플라즈마 처리 효과)

  • Kyu Seok Cho;Han Seung Kang
    • Korean Journal of Environmental Biology
    • /
    • v.40 no.4
    • /
    • pp.641-650
    • /
    • 2022
  • The purpose of this study was to compare the efficiency of air and oxygen injected into the underwater non-thermal dielectric barrier discharge plasma (DBD plasma) device used to remove five types of antibiotics (tetracycline, doxycycline, oxytetracycline, clindamycin, and erythromycin) artificially contained in the fish farm discharge water. The voltage given to generate DBD plasma was 27.8 kV, and the measurement intervals were 0, 0.5, 1, 2, 4, 8, 16 and 32 minutes. Tetracycline antibiotics significantly decreased in 4 minutes when air was injected and were reduced in 30 seconds when oxygen was injected. After the introduction of air and oxygen at 32 minutes, 78.1% and 95.8% of tetracycline were removed, 77.1% and 96.3% of doxycycline were removed, and 77.1% and 95.5% of oxytetracycline were removed, respectively. In air and oxygen, 59.6% and 83.0% of clindamycin and 53.3% and 74.3% of erythromycin were removed, respectively. The two antibiotics showed lower removal efficiency than tetracyclines. In conclusion, fish farm discharge water contains five different types of antibiotics that can be reduced using underwater DBD plasma, and oxygen gas injection outperformed air in terms of removal efficiency.

Development of PCR-based markers for selecting plastid genotypes of Solanum hjertingii (Solanum hjertingii 색소체 유전자형 선발을 위한 PCR 기반 분자마커 개발)

  • Tae-Ho Park
    • Journal of Plant Biotechnology
    • /
    • v.50
    • /
    • pp.34-44
    • /
    • 2023
  • The tetraploid Solanum hjertingii, a wild tuber-bearing species from Mexico is a relative of potato, S. tuberosum. The species has been identified as a potential source of resistance to blackening for potato breeding. It does not exhibit enzymatic browning nor blackspot which are physiological disorders. However, due to their sexual incompatibility, somatic hybridization between S. hjertingii and S. tuberosum must be used to introduce various traits from this wild species into potato. After somatic hybridization, molecular markers are essential for selecting fusion products. In this study, the chloroplast genome of S. hjertingii was sequenced by next-generation sequencing technology and compared with those of other Solanum species to develop specific markers for S. hjertingii. The chloroplast genome has a total sequence length of 155,545 bp, and its size, gene content, order and orientation are similar to those of the other Solanum species. Phylogenic analysis including 15 other Solanaceae species grouped S. hjertingii with S. demissum, S. hougasii, and S. stoloniferum. After detailed comparisons of the chloroplast genome sequence with eight other Solanum species, we identified one InDel and seven SNPs specific to S. hjertingii. Based on these, five PCR-based markers were developed for discriminating S. hjertingii from other Solanum species. The results obtained in this study will aid in exploring the evolutionary aspects of Solanum species and accelerating breeding using S. hjertingii.

Development of the Dielectric Barrier Discharge Plasma Generator for the Eco-friendly Cleaning Process of the Electronic Components (전자부품의 친환경 세정공정 적용을 위한 유전체장벽 방전 플라즈마 생성 장치 개발)

  • Son, Young-Su;Ham, Sang-Yong;Kim, Byung-In
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.10
    • /
    • pp.1217-1223
    • /
    • 2011
  • In this paper, the dielectric barrier discharge plasma generator has been studied for producing of the high concentration ozone gas. Proposed plasma generator has the structure of extremely narrow discharge air gap(0.15mm) in order to realize the high electric field discharge. We investigate the performance of the dielectric barrier discharge plasma generator experimentally and the results show that the generator has very high ozone concentration characteristics of 13.7[wt%/$O_2$] at the oxygen flow rate of 1[${\ell}$/min] of each discharge cell. So, we confirmed that the proposed plasma generator is suitable for the high concentration ozone production facility of the eco-friendly ozone functional water cleaning system in the electronic components cleaning process.

Experiment on the Sterilization Performance of Airborne Bacteria in Indoor Spaces using the Variation of Ozone Concentration Generated According to the Discharge Time of a Plasma Module with a Dielectric Barrier Discharge Technology (유전체 장벽방전 플라즈마 방전시간에 따른 오존 발생 농도변화의 값을 통한 실내 공간 내 부유세균 살균성능에 대한 실험)

  • Su Yeon Lee;Chang Soo Kim;Gyu Ri Kim;Jong Eon Im
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.344-351
    • /
    • 2023
  • Purpose: This study aimed to evaluate the effectiveness of a dielectric barrier discharge (DBD) plasma module for sterilizing airborne bacteria in indoor spaces and measure the concentration of ozone generated during plasma discharge. Method: The DBD plasma module was installed in a 76m3 space, and air samples were collected under various discharge times to compare the reduction of airborne bacteria. Result: The results showed a significant decrease in airborne bacteria, ranging from 92.057% to 99.999%, with an average ozone concentration of 0.04 ppm, below the reference value. Conclusion: The study suggests that plasma discharge can be used as a means of preventing the spread of airborne bacteria and viruses, while ensuring safety for human exposure.

The Ion Transport Phenomena through the Liquid Membrane with Macrocylic Compound (II). Transport of $H^+$Ion through Organic Liquid Membranes Containing Dibenzo-18-crown-6 and Dicyclohexyl-18-crown-6 as Carrier (마크로고리 화합물을 운반체로 하는 액체막을 통한 이온의 운반에 관한 연구 (제2보). 유기액체막 운반체를 통한 수소이온의 운반)

  • Yoon, Chang-Ju;Lee, Shim-Sung;Kim, Young-Hee;Kim, Si-Joong
    • Journal of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.170-175
    • /
    • 1984
  • The transport rates of $H^+$ ion by DBC and DCC as carrier molecules through organic liquid membranes were determined at 25$^{\circ}$C. The transport rates depend highly on the dielectric constants of membrane solvents and these results were discussed in terms of Born's potential energy barrier methods. The sizes of anions also affect the transport rates and these results were well explained theoreticlly by extended Born's equation.

  • PDF

A Basic Study of Plasma Reactor of Dielectric Barrier Discharge for the Water Treatment (수처리용 유전체장벽 플라즈마 반응기에 대한 기초 연구)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.20 no.5
    • /
    • pp.623-630
    • /
    • 2011
  • This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) by using dielectric barrier discharge (DBD) plasma. The DBD plasma reactor of this study consisted of a quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode. The effect of shape (rod, spring and pipe) of ground electrode, diameter (9~30 mm) of ground electrode of spring shape and inside diameter (4~13 mm) of quartz tube, electrode diameter (1~4 mm), electrode materials (SUS, Ti, iron, Cu and W), height difference of discharge and ground electrode (1~15.5 cm) and gas flow rate (1~7 L/min) were evaluated. The experimental results showed that shape of ground electrode and materials of ground and discharge electrode were not influenced the RNO degradation. The thinner the diameter of discharge and ground electrode, the higher RNO degradation rate observed. The effect of height gap of discharge between ground electrode on RNO degradation was not high within the experimented value. Among the experimented parameters, inside diameter of quartz tube and gas flow rate were most important parameters which are influenced the decomposition of RNO. Optimum inside diameter of quartz tube and gas flow rate were 7 mm and 4 L/min, respectively.