• Title/Summary/Keyword: 유입 공기

Search Result 609, Processing Time 0.026 seconds

Analysis of the efficiency of natural ventilation in a multi-span greenhouse using CFD simulation (CFD 시뮬레이션을 이용한 연동형 온실 내 자연환기의 효율성 분석)

  • Short, Ted H.
    • Journal of Bio-Environment Control
    • /
    • v.8 no.1
    • /
    • pp.9-18
    • /
    • 1999
  • Natural ventilation in a four and one-half span, double polyethylene commercial greenhouse was investigated with actual data collected at Quailcrest Farm near Wooster, Ohio. Moreover, a computational fluid dynamics (CFD) numerical technique, FLUENT V4.3, was used to predict natural ventilation rates, thermal conditions, and airflow distributions in the greenhouse. The collected climate data showed that the multi-span greenhouse was well ventilated by the natural ventilation system during the typical summer weather conditions. The maximum recorded air temperature difference between inside and outside the greenhouse was 3.5$^{\circ}C$ during the hottest (34.7$^{\circ}C$) recorded sunny day; the air temperatures in the greenhouse were very uniform with the maximum temperature difference between six widely dispersed locations being only 1.7$^{\circ}C$. The CFD models predicted that air exchange rates were as high as 0.9 volume per minute (A.C. .min$^{-1}$ ) with 2.5m.s$^{-1}$ winds from the west as designed.

  • PDF

Numerical simulation of two-phase flows in hydraulic jump using RANS model (RANS 모형을 이용한 자유도수 2상흐름 수치모의)

  • Choi, Seongwook;Choi, Sung-Uk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.98-98
    • /
    • 2022
  • 도수는 사류가 상류로 천이되며 흐름이 불연속적으로 변하는 현상이다. 도수는 롤러와 벽 제트와 같은 흐름이 발생하는 영역으로 구분되며 큰 에너지 손실을 발생시키므로, 보나 댐과 같은 수리시설물에서는 에너지 소산을 위한 목적으로 도수를 발생시킬 수 있다. 도수구간 중 롤러 영역에서는 공기가 유입되어 복잡한 3차원 2상 흐름을 발생시키므로 공기방울의 거동에 대한 정밀한 모의는 매우 중요한 것으로 평가된다. 그러나 현실적으로 롤러 영역에서의 작은 공기방울까지 재현하는 것은 어려운 일이다. 본 연구에서는 k-ω SST 난류모형을 이용하여 수문 아래에서 발생하는 자유도수를 수치모의하고 연행된 공기량에 대한 특성을 검토하였다. 롤러 영역에서 격자의 해상도를 다르게 하여 도수구간 내 공기의 체적비와 공기방울의 크기 및 공기방울의 거동을 분석하였다. 실내 실험자료에 난류모형을 적용하고 그 결과와 비교하여 모의 결과의 적정성을 확인하였다. 또한 도수구간에서 공기방울 거동의 정밀한 모의가 평균흐름 및 난류량의 종방향 변화에 미치는 영향을 검토하였다.

  • PDF

Development of Venturi System for Microbubble Generation (미세기포 생성을 위한 벤츄리 시스템 개발)

  • Yun, Jeong Eui;Kim, Joo Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.10
    • /
    • pp.865-871
    • /
    • 2014
  • This study was conducted with the aim of developing a venturi-type air supply system for a microbubble generator. In order to determine the influence of the varying geometry of the venturi tube on the flow characteristics, a computational fluid dynamics (CFD) simulation was performed using the commercial CFD software ANSYS CFX-15. Furthermore, in order to elucidate the effects of variation in major design dimensions such as the air supply hole size, position of holes, and number of holes on the air supply characteristics, two-phase multiflow CFD analysis was performed. The analysis results showed that the starting point of expansion on the venturi tube with 0.75 is the best hole position and that the air supply hole size and the number of holes are linearly proportional to the amount of air.

An Application of k-$\varepsilon$ Turbulence Model to Predict How a Rectangular Obstacle with Heat Flux Affects Air Flow in An Experimental Animal House (실험축사의 공기유동예측을 위한 k-$\varepsilon$ 난류모형 적용)

  • Choi, Hong-Lim;Kim, Hyeon-Tae
    • Journal of Bio-Environment Control
    • /
    • v.1 no.1
    • /
    • pp.72-83
    • /
    • 1992
  • 우리 나라 축사는 생산효율 제고를 위하여 대형화, 밀폐화, 고밀도화, 자동화 경향이 뚜렷하다. 대형의 밀폐된 고밀도 축사는 쾌적한 실내환경을 전제로 하기 때문에 기계적으로 실내환경을 적절히 제어하지 않으면 안된다. 제한된 공간에 먼지, 병원성 미생물, 유해기체, 수분이나 열의 과도한 집적은 생산과 재생산효율에 심각한 영향을 미친다. 그러므로 축사내 생산주체인 가축과 작업인이 쾌적한 실내환경에서 생산활동을 할 수 있도록 열적, 화학적/생물학적 환경을 물리적으로 제어하지 않으면 안된다. 본 연구는 실험축사내 가축이 일정한 열을 발생할 때 실내공기의 유동형태를 예측하기 위해서 수행하였다. 이 연구의 결과를 실내환경제어를 위한 환기시스템 책략 개발의 기초자료로 활용할 수 있다. 실험축사내의 공기유동을 예측하기 위해 Body-Fitted Coordinate(BFC)의 격자배열과 k-$\varepsilon$ 난류모형 및 SIMPLE계열 solution scheme을 사용하였으며, 예측의 유효성 검정은 Boon(1978)의 실험결과를 이용하였다. 예측한 공기유동의 형태와 실험한 공기유동의 형태를 비교한 결과 대체로 만족할만한 결과를 얻었다. 그러나 유입공기의 온도가 1$0^{\circ}C$인 경우의 공기유동은 실험유동형태와 약간의 차이가 있었다. 즉, 실험에서는 수평슬롯으로 유입 된 공기가 바로 아래로 굴절되어 유동하였으나, 예측의 결과는 일정 거리로 수평방향으로 유동하다가 아래로 굴절하였다. 이런 유동의 차이는 k-$\varepsilon$ 난류모형 자체가 경험적으로 부력에 민감하게 반응않는 결함이 원인이 될 수도 있으며, 실험의 부적절한 수행이 원인이 될 수도 있다. 이 유동의 경우 Reynolds 수가 3,000정도의 난류이며, 완전발달유동 (fully-developed flow)이므로 관성력 (inertia force)이 부력 (buoyancy force)보다 커, 일정거리 수평으로 유동하다가 아래로 굴절할 수도 있기 때문이다. 앞으로 이를 규명하기 위한 보다 깊이 있는 연구가 이루어져야 할 것이다.

  • PDF

An Effect of the Micro Bubble Formation Depending on the Saturator and the Nozzle in the Dissolved Air Flotation System (DAF 공정에서 공기포화장치와 노즐 특성 별 미세기포 발생에 미치는 영향)

  • Park, S.C.;Oh, H.Y.;Chung, M.K.;Song, S.L.;Ahn, Y.H.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.929-936
    • /
    • 2013
  • The saturator and injection nozzle are important facilities on the dissolved air flotation process. To increase the formation of micro bubble, it is required to improve the air dissolving performance in the saturator and keep the pressure uniform from the saturator to the nozzle. This study aimed to evaluate the performance of the saturator and the hydraulic effect of the nozzle and the pipe structure. The air volume concentration, bubble size and bubble residual time were measured in the test. The saturator, which had mounted with the spray nozzle, showed a good performance for bubble formation. Also, the characteristics of micro bubble formation were influenced by pressure uniformity and flow velocity through the orifice in the nozzle.

An Experimental Study on the Characteristics of the Vitiated Air Heater in the Ramjet Engine Ground-Testing (램제트 엔진의 지상시험용 Vitiated Air Heater의 특성에 관한 실험적 연구)

  • 윤현진;손창현;이충원
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.4
    • /
    • pp.51-57
    • /
    • 1999
  • Temperature and velocity controlling of air at inlet position of Ramjet combustor is important under Ramjet engine grounding-test condition since temperature of inlet air increases due to compression process by supersonic flow at inlet position of Ramjet combustor. In this study, Vitiated Air Heater methodology was used to control temperature of air that is inducted into Ramjet combustor. Temperature and velocity of air at Vitiated air heater exit, which is inducted into Ramjet combustor, were measured to evaluate Vitiated air heater system developed in this study. It is shown that temperature and velocity of inducted air can be well controlled using Vitiated air heater system developed in this study, and we could make a Vitiated Air which is almost same with real air.

  • PDF

Mosquito Net type Harmful Air Breaker (방충망형 오염공기 차단기)

  • Hwang, Dong-Hyeon;Kim, Yong-Jin;Lee, Woo-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.175-176
    • /
    • 2015
  • 봄철 황사나 대기오염으로 인하여 실내에 오염된 공기가 유입되고 있다. 이를 정화하기위해 현재 실내에서는 공기청정기를 사용한다. 그러나 기존의 공기청정기는 이미 실내공기가 오염되었을 때 작동한다. 이를 보완하고자 본 논문에서는 방충망형 오염공기 차단기를 제안하였다. 방충망형 오염공기 차단기는 방충망에 고압의 DC 전압을 인가하여 코로나현상을 일어나게 하도록 만든 장치이다. 코로나 현상이 일어나면 주변 공기가 이온화 되는 원리를 이용하였다. 고압의 DC 전압을 발생시키기 위해 Full-Bridge 인버터를 이용하여 LC공진으로 변압기의 1차측 전압을 상승시켰고, 권선비를 이용하여 변압기 2차측 전압을 승압하였다. 마지막으로 배전압 정류회로를 설계하여 최종 DC전압을 생성하였다. 실험을 통해 제안한 방식의 유용성을 검증하였다.

  • PDF

Measurement of Thermal Characteristics of Electric Unit for Sancheon High-Speed Railcar (고속열차 산천 전장품 발열특성 측정)

  • Park, Won-Hee;Yun, Su-hwan;Park, Choonsoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3672-3679
    • /
    • 2015
  • The heat generated by electrical components during train operation was estimated by measuring the wall temperature in a locomotive, as well as the temperature and speed of the air entering from the outside and then returning to the outside. The temperatures of the electrical components and wall surface in a high-speed train were measured using an infrared camera. The heat generated by the electrical components was exhausted to the outside through a duct installed on the ceiling of the high-speed train. Thus, the temperature and speed of this exhaust air were measured, as well as those of the air entering the locomotive from the outside. The temperatures at the surfaces of the electrical components and walls in the locomotive were also measured using an attachment-type temperature sensor. In addition, the measurement results were applied to analyze how the heat characteristics of the electrical components were affected by the train operation.

Characteristics of Sensible Heat Storage for Gravel (자갈의 현열축열 특성)

  • 이귀현
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.564-572
    • /
    • 2002
  • 본 연구에서는 크기가 서로 다른 자갈로 이루어진 3종류의 축열 매체에 대한 현열축열 특성을 조사하였으며, 그 연구 결과를 요약하면 다음과 같다. (1) 제 1 종 자갈: 축열조로 공급되는 공기의 온도가 5$0^{\circ}C$와 62$^{\circ}C$ 일 때, 축열조 출구의 공기온도가 33$^{\circ}C$에 도달될 때까지 가열되는 축열시간은 각각 170분과 130분이었으며, 방열시간은 각각 210분 및 250분으로 나타났다. 또한, 방열시 출열조 출구의 최고 공기 온도는 공급공기의 온도가 5$0^{\circ}C$와 62$^{\circ}C$ 일 때 각각 34.5$^{\circ}C$ 및 36.5$^{\circ}C$였으며, 출구 공기온도 33$^{\circ}C$이상을 기준으로 한 열 회수 시간은 각각 100분 및 115분으로 나타났다. (2) 제 2종 자갈: 축열조에 공급되는 공기의 온도가 52$^{\circ}C$와 64$^{\circ}C$ 일 때, 축열조 출구의 공기온도가 33$^{\circ}C$에 도달될 때까지 가열되는데 소요된 시간은 각각 175분과 140분이었고, 방열에 소요된 시간은 각각 215분 및 250분으로 나타났다. 방열과정 동안 축열조 출구의 최고 공기온도는 공급공기의 온도가 52$^{\circ}C$$65^{\circ}C$ 일 때 각각 35$^{\circ}C$ 및 38$^{\circ}C$였다. 축열조 출구의 공기온도 33$^{\circ}C$를 기준으로 한 열 회수 시간은 유입공기 온도가 52$^{\circ}C$ 및 64$^{\circ}C$ 일 각각 120분 및 140분으로 나타났다. (3) 제 3종 자갈: 축열조로 공급되는 공기의 온도가 52$^{\circ}C$와 64$^{\circ}C$ 일 때, 축열조 출구의 공기온도가 33$^{\circ}C$에 도달될 때까지 가열되는데 소요된 시간은 가열공기의 온도가 52$^{\circ}C$와 64$^{\circ}C$ 일 때 각각 180분과 150분이었고, 방열에 소요된 시간은 각각 240분 및 270분으로 나타났다. 방열과정 동안 축열조 출구의 최고 공기온도는 가열 공급공기의 온도가 52$^{\circ}C$$65^{\circ}C$일 때 각각 35.5$^{\circ}C$ 및 39.5$^{\circ}C$였다. 출구 공기온도 33$^{\circ}C$이상을 기준으로 한 에너지 회수시간은 유입공기 온도가 52$^{\circ}C$ 및 64$^{\circ}C$일 때 각각 140분 및 160분으로 나타났다. 이와 같이 자갈이 작을수록 축열조 출구의 공기온도가 기준온도 33$^{\circ}C$에 도달되는 시간이 길었으며, 이것은 축열조내의 공극이 작고 비중량이 커 자갈층을 가열시키는 축열시간이 길어지기 때문인 것으로 사료된다. 또한 작은 자갈일수록 방열시간도 다소 길어져 회수 가능 열에너지가 큰 것으로 나타났다.

  • PDF