• Title/Summary/Keyword: 유용에너지

Search Result 1,077, Processing Time 0.031 seconds

Dietary Fiber Intake of Middle School Students in Chungbuk Area and Development of Food Frequency Questionnaire (충북지역 중학생의 식이섬유 섭취 실태 및 식품섭취빈도조사지 개발)

  • Kim, Young-Hye;Kang, Yu-Ju;Lee, In-Seon;Kim, Hyang-Sook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.2
    • /
    • pp.244-252
    • /
    • 2010
  • This study aimed to offer groundwork for grasp and evaluation of nutritional status and dietary fiber intake through 24-hr recall method among middle school students in Chungbuk area. In addition, this study attempted to develop food frequency questionnaire (FFQ) for dietary fiber intake. Average calorie intake per person a day was 2035.6 kcal for boys, and 1876.7 kcal for girls which were 75.4% and 93.8% of estimated energy requirement (EER), respectively. Percent estimated average requirements (%EAR) of calcium, iron and folate were the lowest showing 34.3%, 54.2%, 67.5% for boys and 36.6%, 59.2%, 64.4% for girls, respectively. Average dietary fiber intake per day was $17.6\pm5.3$ g for boys and $16.5\pm4.8$ g for girls which indicate 54.8% and 68.8% of adequate intake (AI), respectively. The main food sources of dietary fiber were polished rice and kimchi. The main food source groups were vegetables, cereals and their products were fruits, seaweeds in the order named, indicating 68.44% total dietary fiber intake from vegetables and cereals. From preliminary 39 food items, 19 food items were selected to derive the correlation coefficient of each food item between 24-hr recall and FFQ method. Correlation coefficient was increased from 0.71 to 0.78 with significant level of p<0.01 after adjustment of FFQ from 39 items to 19 items set. Percentage of classifying subjects into the same levels by food frequency questionnaire and 24-hr recall based on joints classification quartile Kappa value was evaluated. Agreement was highest in the second lowest group showing percentage to correspond rose from 90.2% to 92.4% and Kappa value of 0.54 to 0.59. Consequently, FFQ developed in this study would be useful for estimating the groups which show low intake.

Performance Measurement of Siemens Inveon PET Scanner for Small Animal Imaging (소동물 영상을 위한 Siemens Inveon PET 스캐너의 성능평가)

  • Yu, A-Ram;Kim, Jin-Su;Kim, Kyeong-Min;Lee, Young-Sub;Kim, Jong-Guk;Woo, Sang-Keun;Park, Ji-Ae;Kim, Hee-Joung;Cheon, Gi-Jeong
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • Inveon PET is a recently developed preclinical PET system for small animal. This study was conducted to measure the performance of Inveon PET as recommended by the NEMA NU 4-2008. We measured the spatial resolution, the sensitivity, the scatter fraction and the NECR using a F-18 source. A 3.432 ns coincidence window was used. A $1\;mm^3$ sized F-18 point source was used for the measurement of spatial resolution within an energy window of 350~625 keV. PET acquisition was performed to obtain the spatial resolution from the center to the 5 cm offset toward the edge of the transverse FOV. Sensitivity, scatter fraction, and NECR were measured within an energy window of 350~750 keV. For measuring the sensitivity, a F-18 line source (length: 12.7 cm) was used with concentric 5 aluminum tubes. For the acquisition of the scatter fraction and the NECR, two NEMA scatter phantoms (rat: 50 mm in diameter, 150 mm in length; mouse: 25 mm in diameter, 70 mm in length) were used and the data for 14 half-lives (25.6 hr) was obtained using the F-18 line source (rat: 316 MBq, mouse: 206 MBq). The spatial resolution of the F-18 point source was 1.53, 1.50 and 2.33 mm in the radial, tangential and axial directions, respectively. The volumetric resolution was $5.43\;mm^3$ in the center. The absolute sensitivity was 6.61%. The peak NECR was 486 kcps @121 MBq (rat phantom), and 1056 kcps @128 MBq (mouse phantom). The values of the scatter fraction were 20.59% and 7.93% in the rat and mouse phantoms, respectively. The performances of the Inveon animal PET scanner were measured in this study. This scanner will be useful for animal imaging.

Monte Carlo Study Using GEANT4 of Cyberknife Stereotactic Radiosurgery System (GEANT4를 이용한 정위적 사이버나이프 선량분포의 계산과 측정에 관한 연구)

  • Lee, Chung-Il;Shin, Jae-Won;Shin, Hun-Joo;Jung, Jae-Yong;Kim, Yon-Lae;Min, Jeong-Hwan;Hong, Seung-Woo;Chung, Su-Mi;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.192-200
    • /
    • 2010
  • Cyberknife with small field size is more difficult and complex for dosimetry compared with conventional radiotherapy due to electronic disequilibrium, steep dose gradients and spectrum change of photons and electrons. The purpose of this study demonstrate the usefulness of Geant4 as verification tool of measurement dose for delivering accurate dose by comparing measurement data using the diode detector with results by Geant4 simulation. The development of Monte Carlo Model for Cyberknife was done through the two-step process. In the first step, the treatment head was simulated and Bremsstrahlung spectrum was calculated. Secondly, percent depth dose (PDD) was calculated for six cones with different size, i.e., 5 mm, 10 mm, 20 mm, 30 mm, 50 mm and 60 mm in the model of water phantom. The relative output factor was calculated about 12 fields from 5 mm to 60 mm and then it compared with measurement data by the diode detector. The beam profiles and depth profiles were calculated about different six cones and about each depth of 1.5 cm, 10 cm and 20 cm, respectively. The results about PDD were shown the error the less than 2% which means acceptable in clinical setting. For comparison of relative output factors, the difference was less than 3% in the cones lager than 7.5 mm. However, there was the difference of 6.91% in the 5 mm cone. Although beam profiles were shown the difference less than 2% in the cones larger than 20 mm, there was the error less than 3.5% in the cones smaller than 20 mm. From results, we could demonstrate the usefulness of Geant4 as dose verification tool.

Seasoning of Commercial Wood Using Solar Energy (태양에너지를 이용한 유용목재의 건조)

  • Jung, Hee-Suk;Lee, Hyoung-Woo;Lee, Nam-Ho;Lee, Sang-Bong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.10-39
    • /
    • 1988
  • This study investigated the temperatures and relative humidities in the semi-greenhouse type solar dryer with a black rock-bed heat storage and without heat storage and outdoor temperature and relative humidity at 9 a.m. and 2 p.m.. A comparison was made of the drying rates, final moisture contents, moisture content distributions, casehardening stresses, drying defects, volumetric shrinkage of dried lumber for solar- and air-drying from the green condition of mixtures of Douglas-fir, lauan, taun, oak and sycamore 25mm- and 50 mm-thick lumber during the same period for four seasons, and heat efficiencies for solar dryer with and without the heat storage for saving of heat energy and the cost of lumber drying using the solar energy. The results from this study were summarized as follows: I. The mean weekly temperatures in the solar dryers were 3 to $6^{\circ}C$ at 9 a.m. and 9 to $13^{\circ}C$ at 2 p.m. higher than mean outdoor temperature during all the drying period. 2. The mean weekly relative humidities in the solar dryers were about 1 to 19% at 9 a.m. higher than the outdoor relative humidity. and the difference between indoor and outdoor relative humidity in the morning was greater than in the afternoon. 3. The temperatures and relative humidities in the solar dryer with and without the heat storage were nearly same. 4. The overall solar insolation during the spring months was highest and then was greater in the order of summer, atumm, and winter month. S. The initial rate of solar drying was more rapid than that of air drying. As moisture content decreased, solar drying rate became more rapid than that of air drying. The rates of solar drying with and without heat storage were nearly same. The drying rate of Douglas-fir was fastest and then faster in the order of sycamore, lauan, taun and oak. and the faster drying rate of species, the smaller differences of drying rates between thicknesses of lumber. The drying rates were fastest in the summer and slowest in the winter. The rates of solar drying during the spring were more slowly in the early stage and faster in the later stage than those during the autumn. 6. The final moisture contents were above 15% for 25mm-thick air dried and about 10% for solar dried lumber, but the mean final MCs for 50mm-thick lumber were much higher than those of thin lumber. The differences of final MC between upper and lower course of pile for solar drying were greater than those of pile for air drying. The differences of moisture content between the shell and the core of air dried lumbers were greater than those of solar dried lumber, smallest in the drying during summer and greatest in the drying during winter among seasons. 7. Casehardening stresses of 25mm- and 50mm-thick dried lumber were slight, casehardening stress of solar dried lumber was severer than that of air dried lumber and was similar between solar dried lumber with and without heat storage, Casehardening stresses of lumber dried during spring were slightest and then slighter in the order of summer, autumn, and winter. Casehardening stresses of Douglas -fir, sycamore and lauan were slight, comparing with those of taun and oak. 8. Maximum initial checks of 25mm-thick lumber occurred above and below fiber saturation point and those of 50mm-thick lumber occurred in the higher moisture content than thin lumber. As the moisture content decreased, most of checks were closed and didn't show distinct difference of the degree of checks among drying methods. The degree of checks were very slight in case of Douglas-fir and lauan, and severe in case of taun and oak. The degree of checks for 50mm-thick lumber were severer than those for 25mm-thick lumber. 9. The degree of warpage showed severe in case of oak and sycamore lumber, but no warping was found in case of Douglas-fir, lauan and taun. 10. The volumetric shrinkages of taun and oak were large and medium in case of Douglas-fir, lauan and sycamore. 11. Heat efficiencies of solar dryer with heat storage were 6.9% during spring, 7.7% during summer, 12.1% during autumn and 4.1% during winter season. Heat efficiency of solar dryer with heat storage was slightly greater than that of without heat storage. As moisture content of lumber decreased, heat efficiency decreased.

  • PDF

Use of Mammary Lymphoscintigraphy and Intraoperative Radioguided Gamma Probe in Sentinel Lymph Node Biopsy of Breast Cancer (유방암 환자의 전초림프절 생검에서 유방림프신티그라피와 수술 중 감마프로우브의 유용성)

  • Kim, Soon;Zeon, Seok-Kil;Kim, Yu-Sa
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.478-486
    • /
    • 2000
  • Purpose: The sentinel lymph node is defined as the first draining node from a primary tumor and reflects the histologic feature of the remainder of the lymphatic basin status. The aim of this study was to evaluate the usefulness of lymphoscintigraphy and intraoperative radioguided gamma probe for identification and removal of sentinel lymph node in breast cancer. Materials and Methods: Lymphoscintigraphy was performed preoperatively in 15 patients with biopsy proven primary breast cancer. Tc-99m antimony sulfide colloid was injected intradermally at four points around the tumor. Imaging acquisition included dynamic imaging, followed by early and late static images at 2 hours. The sentinel lymph node criteria on lymphoscintigraphy is the first node of the highest uptake in early and late static images. We tagged the node emitting the highest activity both in vivo and ex vivo. Histologic study for sentinel and axillary lymph node investigation was done by Hematoxylin-Eosin staining. Results: On lymphoscintigraphy, three of 15 patients had clear lymphatic vessels in dynamic images, and 11 of 15 patients showed sentinel lymph node in early static image and three in late static 2 hours image. Mean detection time of sentinel lymph node on lymphoscintigraphy was $33.5{\pm}48.4$ minutes. The sentinel lymph node localization and removal by lymphoscintigraphy and intraoperative gamma probe were successful in 14 of 15 patients (detection rate: 93.3%). On lymphoscintigraphy, 14 of 15 patients showed $2.47{\pm}2.00$ sentinel lymph nodes. On intraoperative gamma probe, $2.36{\pm}1.96$ sentinel lymph nodes were detected. In 7 patients with positive results of sentinel lymph node metastasis, 5 patients showed positive results of axillary lymph node (sensitivity: 72%) but two did not. In 7 patients with negative results of sentinel lymph node metastasis, all axillary nodes were free of disease (specificity: 100%). Conclusion: Sentinel lymph node biopsy with lymphoscintigraphy and intraoperative gamma probe is a reliable method to predict axillary lymph node metastasis in breast cancer, and unnecessary axillary lymph node dissection can be avoided.

  • PDF

Measurement and Monte Carlo Simulation of 6 MV X-rays for Small Radiation Fields (선형가속기의 6 MV X-선에 대한 소형 조사면 측정과 몬테 카를로 시뮬레이션)

  • Jeong Dong Hyeok;Lee Jeong Ok;Kang Jeong Ku;Kim Soo Kon;Kim Seung Kon;Moon Sun Rock
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.195-202
    • /
    • 1998
  • Purpose : In order to obtain basic data for treatment plan in radiosurgery, we measured small fields of 6 MV X-rays and compared the measured data with our Monte Carlo simulations for the small fields. Materials and Methods : The small fields of 1.0, 2.0 and 3.0 cm in diameter were used in this study. Percentage depth dose (PDD) and beam Profiles of those fields were measured and calculated. A small semiconductor detector, water phantoms, and a remote control system were used for the measurement Monte Carlo simulations were Performed using the EGS4 code with the input data prepared for the energy distribution of 6 MV X-rays, beam divergence, circular fields and the geometry of the water phantoms. Results : In the case of PDD values, the calculated values were lower than the measured values for all fields and depths, with the differences being 0.3 to 5.7% at the depths of 20 to 20.0 cm and 0.0 to 8.9% at the surface regions. As a result of the analysis of beam profiles for all field sizes at a depth of loom in water phantom, the measured 90% dose widths were in good agreement with the calculated values, however, the calculated Penumbra radii were 0.1 cm shorter than measured values. Conclusion : The measured PDDs and beam profiles agreement with the Monte Carlo calculations approximately. However, it is different when it comes to calculations in the area of phantom surface and penumbra because the Monte Carlo calculations were performed under the simplified geometries. Therefore, we have to study how to include the actual geometries and more precise data for the field area in Monte Carlo calculations. The Monte Carlo calculations will be used as a useful tool for the very complicated conditions in measurement and verification.

  • PDF

Effects of $H_2O$-fraction of Dioscorea japonica Thunb and selenium on lipid peroxidation in streptozotocin-induced diabetic rats (참마 $H_2O$ 분획물과 Selenium 보충이 당뇨 흰쥐의 지질과산화에 미치는 영향)

  • 김명화
    • Korean journal of food and cookery science
    • /
    • v.17 no.4
    • /
    • pp.344-352
    • /
    • 2001
  • The purpose or this study was to investigate the effect or H $_2$O fraction or Dioscorea japonica Thunb(DJT) and selenium(Se) on the lipid peroxidation in streptozotocin (STZ)-induced diabetic rats. Male Sprague-Dawley rats weighing 180∼220g were divided into 5 groups: One normal rat group and 4 diabetic rat groups(the STZ-Control group, the DJT group, the DJT-Se group and the Se group). Diabetes was induced in the male rats by injection of STZ into tail vein at a dose of 45 mg/kg. The H$_2$O-fraction of DJT(500 mg/kg) was administered orally for 14 days. The supplementation was achieved with the AIN-76 recommendation diet by adding 2 mg/kg diet of selenium as Na$_2$SeO$_3$ which was prepared freshly everyday. The levels of glycogen in liver and muscle and protein in kidney, liver and muscle were measured. The liver concentrations of cholesterol and triglyceride were analyzed. Also, the malondialdehyde(MDA) levels in kidney, liver and lung were determined. The glycogen levels of liver and muscle in diabetic groups were not significantly different from the normal group. The protein concentrations of kidney, liver and muscle were not significantly different either, but the level of muscle protein was higher than STZ-Control group. The levels of liver cholesterol were significantly different between normal and STZ-Control groups and decreased in all diabetic experimental groups fed on H$_2$O-fraction of DJT and Se supplementation compared with the STZ-Control group. The levels of liver triglyceride were higher in the DJT-Se group than the STZ-Control group. The concentrations of MDA in lung decreased greatly by the administration of Se among all and the concentration of liver MDA was significantly reduced and that of DJT-Se group was the lowest. In conclusion, the results indicated that the administration of H$_2$O-fraction of DJT with selenium supplementation has a synergistic antioxidative effect by influencing on lipid metabolites and peroxidation especially in liver.

  • PDF

Recontextualizing geography curriculum:society;student and discipline of geography (地理 敎育課程의 再脈絡化)

  • Seo, Tae Yeol
    • Journal of the Korean Geographical Society
    • /
    • v.29 no.4
    • /
    • pp.438-449
    • /
    • 1994
  • This paper focuses on recontextualizing geography curriculum, i.e. examining recent changing aspects in three geography curriculum locators-society, student and discipline of geography-and searching future directions of geography curriculum in light of such changes. For conciliation and reflection of changing aspects of each locators, this paper dealt with social issues and societal changes in terms of locator of society, increased concern to student and development of cognitive science in terms of students, and challenging views on science and the meaning of epistemological changes in geography in terms of discipline. As a result, three future directions in geography curriculum are searched : issue-based geography curriculum, thinking geography curriculum, geography curriculum toward equity and accessbility.

  • PDF

Automatic Detection of Stage 1 Sleep (자동 분석을 이용한 1단계 수면탐지)

  • 신홍범;한종희;정도언;박광석
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.11-19
    • /
    • 2004
  • Stage 1 sleep provides important information regarding interpretation of nocturnal polysomnography, particularly sleep onset. It is a short transition period from wakeful consciousness to sleep. Lack of prominent sleep events characterizing stage 1 sleep is a major obstacle in automatic sleep stage scoring. In this study, we attempted to utilize simultaneous EEC and EOG processing and analyses to detect stage 1 sleep automatically. Relative powers of the alpha waves and the theta waves were calculated from spectral estimation. Either the relative power of alpha waves less than 50% or the relative power of theta waves more than 23% was regarded as stage 1 sleep. SEM (slow eye movement) was defined as the duration of both eye movement ranging from 1.5 to 4 seconds and regarded also as stage 1 sleep. If one of these three criteria was met, the epoch was regarded as stage 1 sleep. Results f ere compared to the manual rating results done by two polysomnography experts. Total of 169 epochs was analyzed. Agreement rate for stage 1 sleep between automatic detection and manual scoring was 79.3% and Cohen's Kappa was 0.586 (p<0.01). A significant portion (32%) of automatically detected stage 1 sleep included SEM. Generally, digitally-scored sleep s1aging shows the accuracy up to 70%. Considering potential difficulties in stage 1 sleep scoring, the accuracy of 79.3% in this study seems to be robust enough. Simultaneous analysis of EOG provides differential value to the present study from previous oneswhich mainly depended on EEG analysis. The issue of close relationship between SEM and stage 1 sleep raised by Kinnariet at. remains to be a valid one in this study.

Evaluating Impact Resistance of Externally Strengthened Steel Fiber Reinforced Concrete Slab with Fiber Reinforced Polymers (섬유 보강재로 외부 보강된 강섬유 보강 콘크리트 슬래브의 충격저항성능 평가)

  • Yoo, Doo-Yeol;Min, Kyung-Hwan;Lee, Jin-Young;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.293-303
    • /
    • 2012
  • Recently, as construction technology improved, concrete structures not only became larger, taller and longer but were able to perform various functions. However, if extreme loads such as impact, blast, and fire are applied to those structures, it would cause severe property damages and human casualties. Especially, the structural responses from extreme loading are totally different than that from quasi-static loading, because large pressure is applied to structures from mass acceleration effect of impact and blast loads. Therefore, the strain rate effect and damage levels should be considered when concrete structure is designed. In this study, the low velocity impact loading test of steel fiber reinforced concrete (SFRC) slabs including 0%~1.5% (by volume) of steel fibers, and strengthened with two types of FRP sheets was performed to develop an impact resistant structural member. From the test results, the maximum impact load, dissipated energy and the number of drop to failure increased, whereas the maximum displacement and support rotation were reduced by strengthening SFRC slab with FRP sheets in tensile zone. The test results showed that the impact resistance of concrete slab can be substantially improved by externally strengthening using FRP sheets. This result can be used in designing of primary facilities exposed to such extreme loads. The dynamic responses of SFRC slab strengthened with FRP sheets under low velocity impact load were also analyzed using LS-DYNA, a finite element analysis program with an explicit time integration scheme. The comparison of test and analytical results showed that they were within 5% of error with respect to maximum displacements.