• Title/Summary/Keyword: 유방의 크기

Search Result 129, Processing Time 0.022 seconds

Analysis of the cause by Pre Exposure Tube Voltage and Actual Exposure Tube Voltage deviation in Mammography Examination (유방 촬영검사에서 사전조사 관전압과 실제조사 관전압 편차에 따른 원인 분석)

  • Cho, Ji-Hwan;Lee, Hyo-Yeong;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.79-85
    • /
    • 2017
  • The purpose of this study is to investigate the cause analysis according to the difference between the pre exposure tube voltage and actual exposure tube voltage in mammography in connection with breast pressure thickness, breast size and body mass index and to find the improvement. The study tracked 377 women age 40 and older among the mammography examiners conducted by the National Health Insurance Corporation. It was analyzed that breast pressure thickness, breast size and body mass index according to the difference between the pre exposure tube voltage and actual exposure tube voltage among the parameters of dose report been sent to the picture archiving communication system with reference to the image with cranio-caudal projection in mammography. As are result, it shows that the thicker the breast thickness, smaller the breast size and lower body mass index, the higher the difference of tube voltage. In conclusion, the minimum tube voltage of mammography machine should be reset in order to set the tube voltage according to breast pressure thickness and breast size that are suitable for our country in mammography, in addition, it was considered that radiologist should make an effort to reduce radiation exposure and make a good quality image with reducing the difference of mammography condition by making a correct exposure condition in case of examining the patients with thin breast pressure and small breast size.

A Comparison of Field-in-Field Intensity Modulated Radiation Therapy Planning and Conventional Radiation Therapy Planning with Tangential Beam for Breast Cancer (유방암의 접선조사 시 Field-in-Field Intensity Modulated Radiation Therapy와 Conventional Radiation Therapy의 전산화 치료계획에 관한 고찰)

  • Yoo, Soon-Mi;Yeom, Mi-Suk;Kim, Dae-Sup;Back, Geum-Mun;Kwon, Kyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • Purpose: To analyze differences in the dose uniformity for the computed breast radiation therapy planning with tangential beam between conventional RT using wedge filter and FiF-IMRT using multileaf collimator based onsizes and volumes of breasts. Materials and Methods: Thirty breast cancer patients were classified according to the sizes and volumes of the breasts using Eclipse treatment planning system ($Varian^{TM}$, USA, V8.0). Conformity Index and Homogeneity Index were computed along with Dose Volume Histogram. Results: No differencein CI (${\pm}1.2%$) was observed. However, lower mean HI (1.67%) in FiF-IMRT was observed compared to that of the conventional RT. Statically significant (P<0.01) correlation was identified between the values of ${\Delta}HI$ (%) and physical parameters such as breast volumes and separations. Conclusion: Increase in breast volume and separation improves the dose uniformities in computed radiation therapy planning for FiF-IMRT. Physical dimension of the breast should be considered to optimize the compured radiation therapy planning.

  • PDF

The evaluation of contralateral breast's dose and shielding efficiency by breast size about breast implant patient for radiation therapy (인공 유방 확대술을 받은 환자의 유방암 치료 시 크기에 따른 반대 측 유방의 피폭 선량 및 차폐 효율 평가)

  • Kim, Jong Wook;Woo, Heon;Jeong, Hyeon Hak;Kim, Kyeong Ah;Kim, Chan Yong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.329-336
    • /
    • 2014
  • Purpose : To evaluate the dose on a contralateral breast and the usefulness of shielding according to the distance between the contralateral breast and the side of the beam by breast size when patients who got breast implant receive radiation therapy. Materials and Methods : We equipped 200 cc, 300 cc, 400 cc, and 500 cc breast model on the human phantom (Rando-phantom), acquired CT images (philips 16channel, Netherlands) and established the radiation treatment plan, 180 cGy per day on the left breast (EclipseTM ver10.0.42, Varian Medical Systems, USA) by size. We set up each points, A, B, C, and D on the right(contralateral) breast model for measurement by size and by the distance from the beam and attached MOSFET at each points. The 6 MV, 10 MV and 15 MV X-ray were irradiated to the left(target) breast model and we measured exposure dose of contralateral breast model using MOSFET. Also, at the same condition, we acquired the dose value after shielding using only Pb 2 mm and bolus 3 mm under the Pb 2 mm together. Results : As the breast model is bigger from 200 cc to 500 cc, The surface of the contralateral breast is closer to the beam. As a result, from 200 cc to 500 cc, on 180 cGy basis, the measurement value of the scattered ray inclined by 3.22 ~ 4.17% at A point, 4.06 ~ 6.22% at B point, 0.4~0.5% at C point, and was under 0.4% at D point. As the X-ray energy is higher, from 6 MV to 15 MV, on 180 cGy basis, the measurement value of the scattered ray inclined by 4.06~5% at A point, 2.85~4.94% at B point, 0.74~1.65% at C point, and was under 0.4% at D point. As using Pb 2 mm for shield, scattered ray declined by average 9.74% at A and B point, 2.8% at C point, and is under 1% at D point. As using Pb 2 mm and bolus together for shield, scattered ray declined by average 9.76% at A and B point, 2.2% at C point, and is under 1% at D point. Conclusion : Commonly, in case of patients who got breast implant, there is a distance difference by breast size between the contralateral breast and the side of beam. As the distance is closer to the beam, the scattered ray inclined. At the same size of the breast, as the X-ray energy is higher, the exposure dose by scattered ray tends to incline. As a result, as low as possible energy wihtin the plan dose is good for reducing the exposure dose.

The Variation of Scan Time According to Patient's Breast Size and Body Mass Index in Breast Sentinel lymphangiography (유방암의 감시림프절 검사에서 유방크기와 체질량지수에 따른 검사시간 변화)

  • Lee, Da-Young;Nam-Koong, Hyuk;Cho, Seok-Won;Oh, Shin-Hyun;Im, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.62-67
    • /
    • 2012
  • Purpose : At this time, the sentinel lymph node mapping using radioisotope and blue dye is preceded for breast cancer patient's sentinel lymph node biopsy. But all patients were applied the same protocol without consideration of physical specific character like the breast sizes and body mass indexes. The purpose of this study is search the optimized scan time in breast sentinel lymphangiography by observing how much the body mass index and breast size influence speed of lymphatic flow. Materials and Methods : The Object of this study was 100 breast cancer patients(Female, 100 persons, average age $50.34{\pm}10.26$ years old)at Severance hospital from October 2011 to December 2011. They were scanned breast sentinel lymphangiography before operation. This study was performed on Forte dual heads gamma camera (Philips Medical Systems, Nederland B.V.). All patients were intra-dermal injected $^{99m}Tc$-Phytate 18.5 MBq, 0.5 ml. For 80 patients, we have scanned without limitation of scan time until the lymphatic flow from the lymph node since injection. We measured how long the lymphatic flow time between departures from injects site and arrival to lymph node using stopwatch. After we calculated patient's Body mass Index and classified as 4 groups. And we measured patient's breast size and classified 3 groups. The modified breast lymphangiography that changing scan time according to comparison study's result was performed on 20 patients and was estimated. Results : The mean scan time as breast size was A group 2.48 minutes, B group 7.69 minutes, C group 10.43 minutes. The mean scan time as body mass index was under weight 1.35 minutes, normal weight 2.56 minutes, slightly over 5.62 minutes, over weighted 5.62 minutes. The success rate of modified breast lymphangiography was 85%. Conclusion : As the Body mass index became higher and breast size became bigger, the total scan time is increased. Based on the obtained information, we designed modified breast lymphangiography protocol. At the cases applying that protocol, most of sentinel lymph nodes were visualized as lymphatic pool. In conclusion, we found that the more success rate in modified protocol considering physical individuality than study carrying out in the same protocol.

  • PDF

Effects of periodic breast massage on the cyclical mastalgia of fertile women before their menstrual period (유방 마사지가 가임기 여성의 월경 전 주기적 유방통 완화에 미치는 효과)

  • Kang, Kyoung Ae;Lee, Ji A;Hur, Myung-Haeng
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.3
    • /
    • pp.353-362
    • /
    • 2022
  • This study was a randomized controlled trial to examine the effects of breast massage applied to women of childbearing age with cyclic mastagia on breast pain, breast hardness, nipple extensibility, breast size, and breast blood circulation. The study participants were 54 women with cyclic mastalgia who were recruited from Medical Center C, Women's Hospital M, department stores located in City D, and Internet cafes. The experimental treatment was to apply breast massage for a total of 30 minutes, 15 minutes each to the left and right breasts during the period of cyclic mastalgia. After experimental treatment, breast pain (F=49.16, p<.001), breast hardness (Rt t=8.93, p<.001; Lt t=-10.34, p<.001), nipple extensibility (Rt t=3.58, p<.001 ; Lt t=4.66, p<.001), breast size (Rt F=60.59, p<.001; Lt F=51.05, p<.001) and breast blood circulation (Rt t=-1.30, p=.201; Lt t=-2.82, p=.007) were significantly different between the two groups. In conclusion, breast massage performed in this study was effective in relieving breast pain, relieving breast hardness, and improving breast blood circulation in participants with cyclic mastalgia.

Assessment of Detection Rate Applying the Digital Convergence Mammographic Imaging Methods(FFDM, DBT, BMRI): Based on Breast Density (디지털 융복합 유방 영상 검사기법(FFDM, DBT, BMRI)을 사용한 검출률 평가 : 유방밀도에 근거하여)

  • Jang, Eun-Hee;Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.15 no.5
    • /
    • pp.281-291
    • /
    • 2017
  • This study aimed to assess detection rate applying the mammographic imaging methods. The evaluation of the shape and margin of tumor was conducted by score oriented to 180 patients who had undergone FFDM, DBT and BMRI scans among breast cancer patients, and the number of calcification was classified by size. There was no significant difference between DBT and BMRI for tumors larger than 1 cm in low-density breasts and for tumors larger than 2 cm in high-density breasts. Moreover, as for the detection rate of number of fine calcification, the highest rate was observed in FFDM followed by DBT and BMRI in the order named regardless of size. In conclusion, DBT was able to be detected even without BMRI if the mass was larger than 1 cm in the low-density breast and larger than 2 cm in the high-density breast. The detection rate of calcification turned out to be the highest in FFDM followed by DBT regardless of size, and calcification was not observed by BMRI. The appropriate use of FFDM, DBT and BMRI with respect to mass tumor will contribute to serving as a guide to examination methods of reducing burden of patients.

Morphological Feature Analysis of Breast Nuclei for Diagnosis of Breast Cancer (유방질환 진단을 위한 유방 종양 세포핵의 형태학적 특성 비교.분석)

  • 황해길;최현주;최흥국;윤혜경
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2001.06a
    • /
    • pp.91-94
    • /
    • 2001
  • 유방 질만 분석을 위한 병리진단에서는 암종세포의 세관형성 정도와 핵의 다형성과 유사분말정도를 기준으로 하여 나누는 방법이 용이하고 재현성이 높다. 그 중에서도 세포핵의 크기와 다형성, 핵과 세포질의 비율은 양성종양과 악성종양을 분류하는데 있어서 중요한 요소중의 하나이다. 그러므로 본 논문에서는 유방 질단 영상에서 세포핵을 추출하여, 핵의 형태학적 특징값인 핵의 연적 둘레, 가로·세로(장·단축)의 길이를 구하고 핵과 세포질의 비율을 계산한 후, 추출한 형태학적 특성 칸들이 양성종양과 악성종양으로 분류하는데 있어서 유의한 특성 값인지 비교·분석하였다.

  • PDF

Anthropometric Measurements and Volumetric Measurement of the Human Female Breast (유방용적 측정과 인체계측에 관한 연구 -중년여성을 대상으로-)

  • Lee, Kyung-Mi;Park, Hei-Sun
    • Journal of the Korean Home Economics Association
    • /
    • v.38 no.12
    • /
    • pp.249-256
    • /
    • 2000
  • 본 연구는 유방절제수술을 받은 여성들이 착용하는 브래지어와 보정물의 중량을 결정하는데 필요한 예비자료를 수집하기 위하여 중년여성 12명을 대상으로 31항목에 대한 인체계측 및 석고법에 의한 유방용적측정을 실시하고 얻어진 유방관련 항목자료와 각 치수별 무게자료를 비교.분석하였다. 그 결과는 다음과 같다. 1.유방용적 측정결과 모든 피험자에 있어 오른쪽과 왼쪽 유방용적에 차이가 있는 것으로 나타났다. 2. 브래지어 컵 치수는 가슴둘레와 밑가슴둘레간의 차이로 결정되는 것이므로 유방용적과 브래지어 치수의 크기가 일치하지 않는 것으로 나타났다. 3.절반 이상의 피험자가 자신의 브래지어 치수를 잘못 선택하고 있는 것으로 나타났다.

  • PDF

Evaluation of Post-Neoadjuvant Chemotherapy Pathologic Complete Response and Residual Tumor Size of Breast Cancer: Analysis on Accuracy of MRI and Affecting Factors (신보강화학요법 후 유방암의 병리학적 완전 관해 예측 및 잔류 암 평가: 유방자기공명영상의 정확도 및 영향인자 분석)

  • Hyun Soo Ahn;Yeong Yi An;Ye Won Jeon;Young Jin Suh;Hyun-Joo Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.654-669
    • /
    • 2021
  • Purpose To evaluate the accuracy of MRI in predicting the pathological complete response (pCR) and the residual tumor size of breast cancer after neoadjucant chemotherapy (NAC), and to determine the factors affecting the accuarcy. Materials and Methods Eighty-eight breast cancer patients who underwent surgery after NAC at our center between 2010 and 2017 were included in this study. pCR was defined as the absence of invasive cancer on pathological evaluation. The maximum diameter of the residual tumor on post-NAC MRI was compared with the tumor size of the surgical specimen measured pathologically. Statistical analysis was performed to elucidate the factors affecting pCR and the residual tumor size-discrepancy between the MRI and the pathological measurements. Results The pCR rate was 10%. The diagnostic accuracy of MRI and the area under the curve for predicting pCR were 90.91% and 0.8017, respectively. The residual tumor sizes obtained using MRI and pathological measurements showed a strong correlation (r = 0.9, p < 0.001), especially in patients with a single mass lesion (p = 0.047). The size discrepancy between MRI and the pathological measurements was significantly greater in patients with the luminal type (p = 0.023) and multifocal tumors/non-mass enhancement on pre-NAC MRI (p = 0.047). Conclusion MRI is an accurate tool for evaluating pCR and residual tumor size in breast cancer patients who receive NAC. Tumor subtype and initial MRI features affect the accuracy of MRI.

Design of the Detector Head for Single Photon Detection in Breast Cancer Diagnosis and Its Performance Evaluation (유방암진단에서의 단일광자검출을 위한 검출기 전단부의 설계와 성능평가)

  • Kim, Kwang-Hyun;Cho, Gyu-Seong;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.4
    • /
    • pp.263-270
    • /
    • 2003
  • Monte Carlo simulation has been peformed to induce optimized parameters of the detector head of gamma camera for the diagnosis of breast cancer and to evaluate it under the diagnosis condition of the breast cancer. For the simulation, we used Tungsten collimator, having a lattice structured array with holes of $3mm{\times}3mm$ and septal thickness of 0.25 mm, which are corresponding to the pixellated photosensor. For driving optimum parameters we used Trade-Offs procedure between the geometric efficiency and the spatial resolution, varying the detector head components. In order to pre-evaluate the performance of the optimized detector head, we assumed diagnosis condition that the breast tumor is located in the middle of phantom with various sizes and its location is 25 mm from the collimator surface, considering background count caused by radiation sources from other organs. It was shown that the performance of the optimized detector head can be degraded according to the breast cancer size and the background count under real diagnosis conditions of breast cancer. Therefore, it is concluded that the spatial resolution, which is used as an indicator to distinguish the various sizes of breast cancer and is dependent on the characteristic of the detector head, appears to be meaningless in early diagnosis of the breast cancer.