• Title/Summary/Keyword: 유리화기술

Search Result 386, Processing Time 0.034 seconds

Implementing Secure Container Transportation Systems Based on ISO 18185 Specification (ISO 18185 기반의 컨테이너 안전수송 시스템 구현)

  • Choo, Young-Yeol;Choi, Su-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.4
    • /
    • pp.1032-1040
    • /
    • 2010
  • This paper describes implementation of electonic seal (E-Seal) of a container based on ISO 18185 standard and development of monitoring systems checking E-Seal device and cargo states in the container for secure transportation from departure to destination. For lack of definition on confidentiality support in ISO 18185-4 standard, it is vulnerable to security attack such as sniffing. To cope with this, we developed encryption/decryption functions implementing RC5 and AES-128 standards and compared their performance. Experimental results showed that RC5 outperformed AES-128 in terms of time delay. In addition, RC5 had an advantage under the condition of large sized messages as well as CPUs with low performance. However, the portion of encryption/decryption processing time was less than 1 percent of response time including communication delay between E-Seal tags and readers. Hence, the performance difference between RC5 and AES-128 standards was trivial, which revealed that both specifications were allowable in developed systems.

A Study on the Output Performance of Solid-solid Triboelectric Energy Harvesting Depending on the Surface Morphology and Thickness of AAO (AAO 두께 및 표면 형상에 따른 고체-고체 마찰 대전 기반 에너지 하베스팅 발전 성능에 관한 연구)

  • Kwangseok Lee;Woonbong Hwang
    • Composites Research
    • /
    • v.36 no.3
    • /
    • pp.224-229
    • /
    • 2023
  • Due to the increasing demand for wearable devices and miniaturization of various electronic devices, the trend of nanofabrication in IT devices is underway. In order to overcome the limitations of battery size and capacity, there has been a lot of research interest in energy harvesting technology, also known as triboelectric nanogenerator. AAO(Anodic Aluminum oxide) coated with fluoride is a structure that includes an anode layer with high properties in the triboelectric series, an dielectric layer that helps transfer the triboelectrically generated charges to the electrode without loss, and the electrode. For these reasons, AAO has been a lot of research on its application to frictional energy harvesting nanogenerators. In this work, we analyzed the correlation of AAO between the surface morphology and thickness of the insulating layer by utilizing aluminum oxide, which is advantageous for the application of triboelectric nanogenerators, and adjusting the thickness of the insulating layer.

CO2 Methanation Characteristics over Ni Catalyst in a Pressurized Bubbling Fluidized Bed Reactor (가압 기포 유동층 반응기에서의 Ni계 촉매 CO2 메탄화 특성 연구)

  • Son, Seong Hye;Seo, Myung Won;Hwang, Byung Wook;Park, Sung Jin;Kim, Jung Hwan;Lee, Do Yeon;Go, Kang Seok;Jeon, Sang Goo;Yoon, Sung Min;Kim, Yong Ku;Kim, Jae Ho;Ryu, Ho Jeong;Rhee, Young Woo
    • Korean Chemical Engineering Research
    • /
    • v.56 no.6
    • /
    • pp.871-877
    • /
    • 2018
  • Storing the surplus energy from renewable energy resource is one of the challenges related to intermittent and fluctuating nature of renewable energy electricity production. $CO_2$ methanation is well known reaction that as a renewable energy storage system. $CO_2$ methanation requires a catalyst to be active at relatively low temperatures ($250-500^{\circ}C$) and selectivity towards methane. In this study, the catalytic performance test was conducted using a pressurized bubbling fluidized bed reactor (Diameter: 0.025 m and Height: 0.35 m) with $Ni/{\gamma}-Al_2O_3$ (Ni70%, and ${\gamma}-Al_2O_3$30%) catalyst. The range of the reaction conditions were $H_2/CO_2$ mole ratio range of 4.0-6.0, temperature of $300-420^{\circ}C$, pressure of 1-9 bar, and gas velocity ($U_0/U_{mf}$) of 1-5. As the $H_2/CO_2$ mole ratio, temperature and pressure increased, $CO_2$ conversion increases at the experimental temperature range. However, $CO_2$ conversion decreases with increasing gas velocity due to poor mixing characteristics in the fluidized bed. The maximum $CO_2$ conversion of 99.6% was obtained with the operating condition as follows; $H_2/CO_2$ ratio of 5, temperature of $400^{\circ}C$, pressure of 9 bar, and $U_0/U_{mf}$ of 1.4-3.

Evaluation on Organ Dose and Image Quality of Lumbar Spine Radiography Using Glass Dosimeter (유리선량계를 이용한 요추검사의 장기선량 및 영상의 평가)

  • Kim, Jae-Kyeom;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • The purpose of this study was to provide resources for medical exposure reduction through evaluation of organ dose and image resolution for lumbar spine around according to the size of the collimator in DR system. The size of the collimator were varied from $8^{\prime\prime}{\times}17^{\prime\prime}$ to $14^{\prime\prime}{\times}17^{\prime\prime}$ by 1" in AP and lateral projection for the lumbar spine radiography with RANDO phantom. The organ dose measured for liver, stomach, pancreas, kidney and gonad by the glass dosimeter. The image resolution was analyzed using the Image J program. The organ dose of around lumbar spine were reduced as the size of the collimator is decreased in AP projection. There were no significant changes decreasing rate whenever the size of the collimator were reduced 1" in the gonad. The organ dose showed higher on liver and kidney near the surface in lateral projection. There were decreasing rate of less than 5% in liver and kidney, but decreasing rate was 24.34% in the gonad whenever the size of the collimator were reduced 1". Organ dose difference for internal and external of collimator measured $549.8{\mu}Gy$ in the liver and $264.6{\mu}Gy$ in the stomach. There were no significant changes organ dose difference that measured $1,135.1{\mu}Gy$ in the gonad. Image Quality made no difference because SNR and PSNR were over than 30 dB when the collimator size is less than $9^{\prime\prime}{\times}17^{\prime\prime}$ on AP projection and $10^{\prime\prime}{\times}17^{\prime\prime}$ on lateral projection. Therefore, we are considered that the recommendations criterion for control of collimator were suggested in order to reduce unnecessary X-ray exposure and to obtain good image quality because lumbar spine radiography contains a lot of peripheral organs rather than other area radiography.

The Evaluation of Various Conditions in the Cryopreservation of Primordial Germ Cells on Korean Native Chicken (Ogye) (한국재래닭(오계)의 원시 생식 세포의 냉동 보존에 있어서 여러 조건의 평가)

  • Kim, Hyun;Cho, Young Moo;Han, Jae Yong;Choi, Sung Bok;Byun, Mi Jeong;Kim, Young Sin;Ko, Yeoung-Gyu;Seong, Hwan-Hoo;Kim, Sung Woo
    • Korean Journal of Poultry Science
    • /
    • v.41 no.4
    • /
    • pp.249-259
    • /
    • 2014
  • Cryopreserving cells which are maintaining their viability are the very complex process. This study has been carried out in order to find the effects of cryopreservation steps and freezing media on the rates of viability of cryopreserved chicken primordial germ cells (PGCs). PGCs obtained from the germinal gonade of 5.5~6 day (stage 28) chick embryos of Korean Ogye (KO) and Commercial breeds (C), using the MACS method were suspended in a freezing medium containing a freezing and protecting agents (e.g. dimethyl sulfoxide (DMSO), ethylene glycol (EG) and propylene glycol (PG)). Gonads were harvested from stage 28 chick embryos and pooled in groups of 5, 10, 15, 20E embryos, contributing gonads to the cell suspension. The gonadal cells, including PGCs, were then frozen in 1 of the following cryoprotectant treatments : 2.5%, 5%, 10%, 15% and 0% cryoprotectant (DMSO, EG, PG) as a control. Effects of exposure to slow freezing and vitrification, with different concentrations of the cryoprotectant solution, were examined. After vitrification and slow freezing, survival rates of the frozen-thawed PGCs from the 10% EG plus FBS treatment were 85.63%, and 66.14% (p<0.05), respectively. The viability of PGCs after freeze-thawing was significantly higher for 10% EG plus FBS treatment than for 10% PG + FBS treatment (p<0.05) (85.63% vs 66.81%) by vitrification. This study established a method for preserving chicken PGCs that enables systematic storage and labeling of cryopreserved PGCs in liquid ($LN_2$) at a germplasm repository and ease of entry into a data base. In the future, the importance for this new technology is that poultry lines can be conserved while work is being conducted on improving the production of germline chimeras.

Effect of Ethylene Glycol(EG) and Propylene Glycol(PG) on the Viability of Frozen-thawed Primordial Germ Cells(PGCs) on Korean Native Chicken(Ogye) by Vitrification (한국재래닭(오계)의 유리화 동결 시 생존율에 미치는 Ethylene Glycol(EG)과 Propylene Glycol(PG)의 영향)

  • Kim, Hyun;Kim, Dong Hun;Han, Jae Yong;Choi, Sung Bok;Ko, Yeoung Gyu;Do, Yoon Jung;Seong, Hwan-Hoo;Kim, Sung Woo
    • Korean Journal of Poultry Science
    • /
    • v.40 no.3
    • /
    • pp.197-205
    • /
    • 2013
  • This study established a method for preserving chicken primordial germ cells (PGCs) that enables long-term storage in liquid nitrogen ($LN_2$) for preservation of the species. The purpose of this study was to compare the effects of Ethylene Glycol (EG) and Propylene Glycol (PG) on viability of cryopreserved PGCs with vitrification in Korean Native Chicken (Ogye), and to fine should be find or to the optimal protocol for PGCs freezing. One of the important components of cryopreservation process is cryopreservation medium that plays a vital role in preventing cellular injury during freeze-thawing. Cryoprotective agents have been known to improve cell viability after freeze-thawing. PGCs obtained from the germinal gonade of 5.5~6 day (stage 28) chick embryos, using the MACS method were suspended in a freezing medium containing a freezing and protecting agents. Gonads were harvested from stage 28 chick embryos and pooled in groups of 10E embryos, contributing gonads to the cell suspension. The gonadal cells, including PGCs, were then frozen in 1 of the following cryoprotectant treatments: 2.5% EG, 5% EG, 10% EG, 2.5% PG, 5% PG, 10% PG, and 0% cryoprotectant as a control. Effects of exposure to vitrification solution and vitrification, with different concentrations of the cryoprotectant solution, were examined. After freezing and thawing, survival rates of the frozen-thawed PGCs from the 0, 2.5, 5, 10 and 15% EG plus FBS treatment were 44.24%, 64.51%, 85.63%, 80.51% and 73.52% (p<0.05), respectively. The viability of PGCs after freeze-thawing was significantly higher for 10% EG plus FBS treatment than for 10% PG + FBS treatment (p<0.05)(85.63% vs 66.81%). Therefore, these systems may contribute in the improvement of cryopreservation for a scarce species in birds preservation. This study established a method for preserving chicken PGC that enables systematic storage and labeling of cryopreserved PGCs in liquid N at a germplasm repository and ease of entry into a database. In the future, the importance for this new technology is that poultry lines can be conserved while work is being conducted on improving the production of germline chimeras.

Optimization of highly scalable gate dielectrics by stacking Ta2O5 and SiO2 thin films for advanced MOSFET technology

  • Kim, Tae-Wan;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.259-259
    • /
    • 2016
  • 반도체 산업 전반에 걸쳐 이루어지고 있는 연구는 소자를 더 작게 만들면서도 구동능력은 우수한 소자를 만들어내는 것이라고 할 수 있다. 따라서 소자의 미세화와 함께 트랜지스터의 구동능력의 향상을 위한 기술개발에 대한 필요성이 점차 커지고 있으며, 고유전(high-k)재료를 트랜지스터의 게이트 절연막으로 이용하는 방법이 개발되고 있다. High-k 재료를 트랜지스터의 게이트 절연막에 적용하면 낮은 전압으로 소자를 구동할 수 있어서 소비전력이 감소하고 소자의 미세화 측면에서도 매우 유리하다. 그러나, 초미세화된 소자를 제작하기 위하여 high-k 절연막의 두께를 줄이게 되면, 전기적 용량(capacitance)은 커지지만 에너지 밴드 오프셋(band-offset)이 기존의 실리콘 산화막(SiO2)보다 작고 또한 열공정에 의해 쉽게 결정화가 이루어지기 때문에 누설전류가 발생하여 소자의 열화를 초래할 수 있다. 따라서, 최근에는 이러한 문제를 해결하기 위하여 게이트 절연막 엔지니어링을 통해서 누설전류를 줄이면서 전기적 용량을 확보할 수 있는 연구가 주목받고 있다. 본 실험에서는 high-k 물질인 Ta2O5와 SiO2를 적층시켜서 누설전류를 줄이면서 동시에 높은 캐패시턴스를 달성할 수 있는 게이트 절연막 엔지니어링에 대한 연구를 진행하였다. 먼저 n-type Si 기판을 표준 RCA 세정한 다음, RF sputter를 사용하여 두께가 Ta2O5/SiO2 = 50/0, 50/5, 50/10, 25/10, 25/5 nm인 적층구조의 게이트 절연막을 형성하였다. 다음으로 Al 게이트 전극을 150 nm의 두께로 증착한 다음, 전기적 특성 개선을 위하여 furnace N2 분위기에서 $400^{\circ}C$로 30분간 후속 열처리를 진행하여 MOS capacitor 소자를 제작하였고, I-V 및 C-V 측정을 통하여 형성된 게이트 절연막의 전기적 특성을 평가하였다. 그 결과, Ta2O5/SiO2 = 50/0, 50/5, 50/10 nm인 게이트 절연막들은 누설전류는 낮지만, 큰 용량을 얻을 수 없었다. 한편, Ta2O5/SiO2 = 25/10, 25/5 nm의 조합에서는 충분한 용량을 확보할 수 있었다. 적층된 게이트 절연막의 유전상수는 25/5 nm, 25/10 nm 각각 8.3, 7.6으로 비슷하였지만, 문턱치 전압(VTH)은 각각 -0.64 V, -0.18 V로 25/10 nm가 0 V에 보다 근접한 값을 나타내었다. 한편, 누설전류는 25/10 nm가 25/5 nm보다 약 20 nA (@5 V) 낮은 것을 확인할 수 있었으며 절연파괴전압(breakdown voltage)도 증가한 것을 확인하였다. 결론적으로 Ta2O5/SiO2 적층 절연막의 두께가 25nm/10nm에서 최적의 특성을 얻을 수 있었으며, 본 실험과 같이 게이트 절연막 엔지니어링을 통하여 효과적으로 누설전류를 줄이고 게이트 용량을 증가시킴으로써 고집적화된 소자의 제작에 유용한 기술로 기대된다.

  • PDF

The study of Dissimilar Urban Space Characteristics between the Structure-advanced Industrial park area within the city and the Adjacent Spaces (도시 내 구조고도화 산업단지와 연접지역의 이질적 도시 공간 특성 연구)

  • Choi, Hyung-Ku;Kim, Won-Pil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7617-7628
    • /
    • 2015
  • Recent changes in the industrial parks have become a major issue in the nation's economic aspect. However, the industrial park's structure-advance projects under regional changes have excluded the surrounding spaces. The purpose of study is to analyze physical characteristics of Industrial park and adjacent area and to propose practical urban linkage alternatives as place-making It was found that in an urban aspect, the industrial parks belong within the city, but look like an isolated island that doesn't belong to a city. Therefore, as a way that could improve the problems above, and prevent the formation of heterogeneous spaces, the deliberate management of Industrial park's structure-advancement projects is needed. As one of these measures, It is concluded that the review of designating industrial facility zones which is a district unit plan and managing the detailed elements of construction to the various elements of the district level are needed.

A study on standardization and R&D strategies of agrifood-ICT convergence technology (농식품-ICT 융·복합 기술 개발 및 표준화 추진방향)

  • Min, J.H.;Huh, M.Y.;Park, J.Y.
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.777-780
    • /
    • 2015
  • Currently, our country has promoted sustainable growth in agriculture field by expanding the growth engine which is going to creat new value through agrifood industry & ICT convergence, the deployment of computerization in rural areas and the efficiency increase of agricultural administration system. Since the level of domestic agriculture-ICT convergence technology focusing on production areas is at early stage, it is necessary to deploy the successful models through the systematic development of technology and standardization including production, distribution and consumption phase. In addition, because the management and control systems of large glass greenhouse are mostly foreign products with no standardization and related small domestic companies, there is a limit to agri-food & ICT convergence activation led by the agri-food private sector. Also, it is vital to increase productivity & efficiency and improve quality throughout the entire agricultural process including production, distribution and consumption by the fusion of information technology, automatic control technology and unique ICT on existing agricultural technology, Therefore, in this paper we propose the agricultural-ICT convergence technology fields in which our country can lead technology and the standardization plans through analyzing the development, policy and standardization trends on agricultural-ICT convergence technology.

  • PDF

Structural Performance and Usability of Void Slab Established in T-deck Plate (T형 데크 플레이트 중공형 슬래브의 구조성능 및 사용성능)

  • Hong, Eun-Ae;Chung, Lan;Paik, In-Kwan;Yun, Sung-Ho;Cho, Seung-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.677-684
    • /
    • 2012
  • In recent years, extension of life span of buildings is becoming an important issue in our society. To improve the life span of buildings, rhamen structure construction and long-spanned structures are advantageous. And in order to achieve this goal, structural elements of buildings must be light and slender. As an alternative method, general porous slabs are used frequently domestically and internationally. But the study on the porous slabs using T-deck plate and assembly of light weight precast construction is insufficient at present. In this study, flexural and fatigue tests were performed on six specimens to verify structural performance and serviceability. The main parameters of the specimens were light weight and T-deck plate construction possibility as well as slab thickness. The test results indicated that the strength of porous slabs using T-deck plate and assembly of light weight were much better than general RC slabs and porous slabs without T-deck plate. And stiffness was much better than that of other tested slabs.