• Title/Summary/Keyword: 유량 오차율

Search Result 62, Processing Time 0.027 seconds

Uncertainty of Discharge-SS Relationship Used for Turbid Flow Modeling (탁수모델링에 사용하는 유량-SS 관계의 불확실성)

  • Chung, Se-Woong;Lee, Jung-Hyun;Lee, Heung-Soo;Maeng, Seung-Jin
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.12
    • /
    • pp.991-1000
    • /
    • 2011
  • The relationship between discharge (Q) and suspended sediment (SS) concentration often is used for the estimation of inflow SS concentration in reservoir turbidity modeling in the absence of actual measurements. The power function, SS=aQb, is the most commonly used empirical relation to determine the SS load assuming the SS flux is controlled by variations of discharge. However, Q-SS relation typically is site specific and can vary depending on the season of the year. In addition, the relation sometimes shows hysteresis during rising limb and falling limb for an event hydrograph. The objective of this study was to examine the hysteresis of Q-SS relationships through continuous field measurements during flood events at inflow rivers of Yongdam Reservoir and Soyang Reservoir, and to analyze its effect on the bias of SS load estimation. The results confirmed that Q-SS relations display a high degree of scatter and clock-wise hysteresis during flood events, and higher SS concentrations were observed during rising limb than falling limb at the same discharge. The hysteresis caused significant bias and underestimation of SS loading to the reservoirs when the power function is used, which is important consideration in turbidity modeling for the reservoirs. As an alternative of Q-SS relation, turbidity-SS relation is suggested. The turbidity-SS relations showed less variations and dramatically reduced the bias with observed SS loading. Therefore, a real-time monitoring of inflow turbidity is necessary to better estimate of SS influx to the reservoirs and enhance the reliability of reservoir turbidity modeling.

The Propose of Optimal Flow Data Acquisition by Error Rate Analysis of Flow Data (유량 데이터 오차율 분석을 통한 최적의 유량데이터 취득방안 제안)

  • Kim, Yunha;Choi, Hyunju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.3
    • /
    • pp.249-256
    • /
    • 2017
  • Recently, application areas based on M2M (Machine-to-Machine communications) and IoT (Internet of Things) technologies are expanding rapidly. Accordingly, water flow and water quality management improvements are being pursued by applying this technology to water and sewage facilities. Especially, water management will collect and store accurate data based on various ICT technologies, and then will expand its service range to remote meter-reading service using smart metering system. For this, the error in flow rate data transmitting should be minimized to obtain credibility on related additional service system such as real time water flow rate analysis and billing. In this study, we have identified the structural problems in transmitting process and protocol to minimize errors in flow rate data transmission and its handling process which is essential to water supply pipeline management. The result confirmed that data acquisition via communication system is better than via analogue current values and pulse, and for communication method case, applying the industrial standard protocol is better for minimizing errors during data acquisition versus applying user assigned method.

Hydrological survey and analysis considering field conditions (현장여건을 고려한 수문조사 및 분석)

  • HwangBo, Jong-Gu;Yu, Young-moo;Jeong, Chan-Woong;Lee, Sang-Ho;Seo, Jeong-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.265-265
    • /
    • 2022
  • 유량조사는 측선수, 측정시간, 측정위치, 측정방법 등 많은 기준이 있으며 이를 잘 준수하는 것이 높은 품질의 유량측정 성과를 확보하는 방법이다. 그러나 이러한 기본적인 기준을 잘 준수하더라도 현장 상황에 따라 유량측정 성과에 오차가 포함 될 수 있다. 본 연구에서는 상류 소수력발전소의 방류량에 따라 유량이 변화하고 수위관측소 부근에 큰 저류공간이 있는 현장 여건이 유량측정성과에 어떠한 영향을 끼치는지 검토하였다. 홍천군(주음치교) 관측소는 홍천강 상류에 위치하며 소수력발전소의 운영에 따라 관측소를 흘러가며 그 유량이 소수력발전소의 영향으로 점변한다. 일반적으로 이러한 경우 측정시간을 최대한 짧게 가져가 유량자료의 정확도를 확보한다. 하지만 홍천군(주음치교)의 경우 수위관측소 주변에 큰 저류공간이 있어 이를 동시에 고려해야 하며 단순하게 측정시간을 짧게 하는 것만으로는 측정성과의 품질을 확보 할 수 없다. 왜냐하면 이 저류 공간으로 물이 유입되는 시간동안은 수위관측소의 수위 상승은 미미하지만 하천 유량은 증가하는 부등류가 발생한다. 유량측정은 등류가정에 의한 것으로 수위관측소 주변이 부등류가 발생하면 유량측정 성과에 큰 오류가 나타나기도 한다. 홍천군(주음치교)에서 현장 상황이 등류일 때와 부등류일 때 모두 측정을 실시하였으며 그 차이를 확인하였다. 저류공간의 물 유입이나 유출이 없는, 즉 등류 상태의 유량측정 성과는 수위-유량관계식과 2.86%차이를 보였으며 부등류 상태의 유량측정 성과는 19.85%차이를 보여 큰 차이를 보였다(기준수위 0.49m). 또한 소수력발전소 운영에 따라 유량 상승 시에는 수위-유량관계곡선식 대비하야 양(+)의 편차율이 발생하고, 유량이 하강 시에는 수위-유량관곡선식 대비 음(-)의 편차율 발생하는 것으로 나타났다. 소수력 발전소는 동절기를 제외한 상시 운영으로 홍천군(주음치교) 관측소의 정확한 수위-유량관계식을 확인하기 위하여 소수력 발전소 운영을 중단하고 측정을 실시하였으며 유량변동을 멈추고, 즉 등류 흐름에서 측정한 성과는 수위-유량관계식과 차이가 1.06% 불과한 것으로 나타났다. 수문조사는 측선수, 측정시간, 측점수 등 많은 기준이 있다. 그러나 이러한 측정기준과는 별개로 현장은 다양한 조건이 발생하며 측정성과의 정확도에 영향을 끼치는 경우가 발생하기도 한다. 따라서 유량측정 기준을 잘 준수하는 것도 중요하지만 현장상황을 파악하고 이에 적절한 유량측정을 실시해야 그 오차를 최소화 할 수 있다.

  • PDF

Low flow projection considering actual evapotranspiration by climate change (기후변화에 따른 실제증발산을 고려한 갈수량 전망)

  • Kim, Eunji;Kang, Boosik;Sun, Hoyoung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.384-384
    • /
    • 2020
  • 갈수량은 연간 355번째에 해당하는 일유량으로 연중 10일은 유지할 수 있는 유량을 의미한다. 갈수량은 하천유지유량을 결정하고 다목적댐의 이수안전도를 평가하는 기준으로 활용되는 지표로 활용되고 있으나 현재 기준으로는 과거사상에 초점을 맞추어 산정되고 있다. 본 연구에서는 기후변화에 따른 수문사상의 변화로 인한 미래 극한사상에 대비한 평가기준 마련을 위하여 CMIP5의 GCM 자료를 활용한 한강수계의 소양강댐의 실제증발산량을 추정하고, 이를 고려한 갈수량을 전망하고자 한다. 실제증발산의 경우 관측자료가 부재하므로 증발산 보완관계 가설 기반의 간접계산을 통해 추정하였으며, 잠재증발산량은 FAO Penman-Monteith 공식, 습윤증발산량은 Priestley-Taylor공식을 활용하여 산정하였다. 기준기간(1974-2000년) GCM 자료의 보정은 강우 및 증발산에 대하여 정상성 분위사상법을 적용하였으며, 우리나라의 홍수기 특성을 반영하기 위하여 홍수기(6~9월) 및 비홍수기(10~5월)로 구분하였다. 소양강댐 유역에 대한 연단위 원시 GCM의 경우, 연단위 강우와 실제증발산 각각 -20.0%, +17.3%의 오차율을 보였으나, 지역오차보정 후 각각 -1.2%, -0.2%로 개선되었다. 전망기간(2011-2100년)에 대해서는 비정상성 분위사상법을 적용하였으며, 지역오차보정 과정을 거친 강우 및 실제증발산 자료는 장기유출모형의 입력자료로 활용되었다. 실제증발산을 고려한 유출량을 산정하기 위해 IHACRES 모형을 활용하였으며, 갈수량은 모형으로부터 산정된 유출 시계열에 대한 lognormal 분포의 누적확률밀도함수의 3%에 해당하는 값으로 결정하였다. 전망결과는 근미래(Near future, 2011~2040년), 중미래(Midcentury future, 2041~2070년), 먼미래(Distance future, 2071~2100년)로 나누어 제시하였으며, 미래구간별 추세를 반영한 증감율을 제시하였다.

  • PDF

Development of Looped Rating Curve at Hwawon Station (화원 수위관측소 지점의 고리모양 수위-유량 관계곡선 작성)

  • Kang Shin-Uk;Lee Sang-Ho;Hwang Man-Ha
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.6 s.167
    • /
    • pp.487-494
    • /
    • 2006
  • The flood discharge on the rising limb of a hydrograph at Hwawon station greatly differs from the flood discharge on the falling limb for the same stage. When there is such a big hysteresis, there can be a significant amount of errors in the rated discharge obtained from a simple rating curve. To reduce errors in rated discharges, a looped rating curve was established for Hwawon station in the Nakdong River. In order to compute the deviation between real discharges and simply rated discharges, a simple rating curve was established using the stage and discharge data from the results of a hydraulic channel routing. The relationship between the discharge deviation ${\Delta}Q$ and a product of B and ${\Delta}h/{\Delta}t$ was analysed, where B is the channel topwidth; ${\Delta}h$ is the stage increment; At is the time increment. Strong relation between ${\Delta}Q$ and $B{\Delta}h/{\Delta}t$ was found. The discharges calculated from the relationship show differences by 10 % or less for the 7 observations out of 11 observations in 1997 whose stages exceeds 7 m. The observed discharges for the stages over 9 m in 1998 also show small difference with the discharges estimated from the loop rating curve. Looped rating curve is recommended, instead of the simple rating curve to reduce the errors of rated discharges for gauging stations like Hwawon, which has relatively large loop width.

Estimating the Influence of the Riffle and Pool on the Habitat of Fish (여울과 소의 형성 조건에 따른 어류 서식처 환경 영향)

  • Sung, Young-Du;Park, Bong-Jin;Lee, Sam-Hee;Cjung, Kwan-Sue
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1007-1011
    • /
    • 2006
  • 본 연구에서는 어류 생태계 유지를 위해 필요한 생태학적 추천유량을 산정하고, 어류의 서식처 환경인 여울과 웅덩이의 형성조건을 검토함으로써 '작용'인 '흐름'과 '응답'인 '하상구조'와의 상관 관계를 규명하고자 하였다. 본 연구의 대상하천인 금호강에서는 하상변동이 활발한 자연 상태를 벗어나 하상의 이동성 상당히 둔화된 상태이며, 저수로내 여울과 웅덩이도 대표어종이 서식할 수 있는 자갈하상 구조에 변화가 일어나고 있는 것으로 분석되었다. 이것은 금호강 상류에 영천댐 건설의 영향이 어느 정도 미치고 있음을 유황분석 결과를 통해 간접적으로 파악할 수 있었다. 댐과 같은 수공구조물의 건설로 인하여 하도가 고정화된 상태에서 장기간에 걸치게 되면 여울과 웅덩이와 같은 하상구조가 축소되거나 소멸되어 금호강에서의 대표어종 서식처 환경에 영향을 미칠 것으로 추정된다. 금번 연구결과, 금호강에서 어류의 생식에 필요한 생태학적 추천유량 $8.2m^3/sec$가 필요하였으며, 어류의 서식처 환경인 여울과 웅덩이를 지속적으로 유지되기 위해서는 $250m^3/sec$ 이상의 유량이 연간 한번 이상 흘러야 하고, 2.5년 내지 3년 마다 약 $500m^3/sec$ 정도의 유량이 흐를 필요가 있다고 분석되었다. 본 연구 대상지점에서 흐름과 하상구조를 하천생태계와 연계해서 볼 때, 생태추천유량은 어디까지나 대표어종이 서식할 수 있는 최소조건에 불과하다. 대표어종이 장기간에 걸쳐 서식할 수 있는 하상구조가 존재하기 위해서는 대표어종이 선호하는 여울과 웅덩이가 필요하다. 결국 대표어종이 서식하기 위한 필요충분조건은 생태추천유량 확보와 아울러 대표어종이 선호하는 하상구조를 유지하기 위해서는 하도의 이동성을 유발할 유황변화가 필요하다는 것이 입증되었다.대상으로 연중 발생하는 큰 호우사상에 대해 임의의 강우관측소를 결측지점으로 가정하고 주변의 강우관측소로부터 각각의 방법을 이용해 가중치들을 산정하여 결측지점의 강우량 값을 보정하고자 하였다. 또한 각각의 방법을 이용하여 얻어진 결과에 대해 실측값과 보정값의 오차정도를 평균절대오차법(Mean Absolute Error)과 제곱평균제곱근오차법(Root Mean Squared Error)에 의해 산정하여 보정 방법간의 효율성을 검토하고자 하였다.9년, 그리고 2010년${\sim}$2019년까지 총 4구간으로 나누어 결과를 도출하였으며 예상한 바와 같이 후반기 20년 동안에 세 가지 지표가 취약해 지는 것을 확인할 수 있었고, 특히 2000년부터 2009년까지 10년 동안에는 더욱 취약해짐을 확인할 수 있었다.를 보임에 따라 그 정책적 효과는 때로 역기능적인 결과로 초래하였다. 그럼에도 불구하고 이 연구결과를 통하여 최소한 주식시장(株式市場)에서 위탁증거금제도는 그 제도적 의의가 여전히 있다는 사실이 확인되었다. 또한 우리나라 주식시장에서 통상 과열투기 행위가 빈번히 일어나 주식시장을 교란시킴으로써 건전한 투자풍토조성에 저해된다는 저간의 우려가 매우 커왔으나 표본 기간동안에 대하여 실증분석을 한 결과 주식시장 전체적으로 볼 때 주가변동율(株價變動率), 특히 초과주가변동율(超過株價變動率)에 미치는 영향이 그다지 심각한 정도는 아니었으며 오히려 우리나라의 주식시장은 미국시장에 비해 주가가 비교적 안정적인 수준을 유지해 왔다고 볼 수 있다.36.4%)와 외식을 선호(29.1%)${\lrcorner}$ 하기 때문에 패스트푸드를 이용하게 된 것으로 응답 하였으며, 남 여 대학생간에는 유의한 차이(p<0.05)가 인정되었다. 응답자의 체형은 ${\ulco

  • PDF

Numerical analysis according to evaporator type (증발기 형태에 따른 수치적 해석)

  • Kim, Dae Yeong;Kim, Moon Ki;Yun, Hong Sun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.103-103
    • /
    • 2017
  • 증발기의 형태에 따라 수치적 해석을 진행하면서 최적의 효율을 나타낼 수 있는 증발기를 설계하는 것이 중요하다. 증발기의 수치적 해석은 EES 프로그램을 이용하여 진행되었으며, 계산의 검증은 자사의 제품의 성능과 비교하면서 검증하였다. 증발기의 수치적 해석의 구성은 지배방정식과 연속방정식을 이용하여, 냉매의 총괄열전달계수, 관내외벽의 열전도율, 공기의 총괄열전달계수를 이용하여 총괄열전달계수를 계산하였으며, 총괄열전달계수를 이용하여 증발기의 열량을 계산하였다. 증발기의 수치적 해석과 자사 제품 5개의 제품과 비교하였고, 평균적으로 약 10%의 오차율을 보였다. 신뢰성이 확보된 계산식을 이용하여 Fin의 간격, 단위 질량유량, 열 교환 코일 길이, 풍량의 조건을 각각 변동시켜 증발기 열량 비교를 하며 경향성을 고찰하였다. Fin의 간격을 1mm에서 20mm으로 0.5mm 간격으로 변화 시켰을 경우, 핀 간격이 좁으면 공기 유속이 빨라져 열 교환 효율이 낮아지며, 반대로 넓어지면 냉매 유량에 비해 공기 유량이 많기 때문에 열 교환 효율이 낮아진다. 열 교환 코일 길이를 500mm에서 2400mm으로 50mm 간격으로 변화 시켰을 경우, 열 교환 코일 길이가 길어질수록 배관의 마찰력과 냉매의 온도 상승으로 인하여 공기 온도와의 온도 차이가 줄어들어 열 교환 효율은 낮아진다. 풍량을 20cmm에서 400cmm으로 10cmm 간격으로 변화 시켰을 경우, 일정 풍량 이상 올라가면 공기 유속이 빨라져서 열량이 낮아지는 경향을 보인다. 질량유량을 3g/sec에서 174g/sec으로 4.5g/sec 간격으로 변화 시켰을 경우, 질량 유량에 따라 비례적으로 열량이 높아지는 경향을 보이다가 일정 질량 유량 이상에서는 공기 풍량에 비해 냉매 유량이 많기 때문에 반비례적으로 열량이 낮아진다. 이처럼 증발기의 설계는 Fin 간격, 열 교환 코일 길이, 풍량, 질량유량 등을 복합적으로 고려하여 증발기 설계를 해야 하며, 저장고의 크기, 부하, 사용목적에 따라 최적화된 증발기를 설계하여야 한다.

  • PDF

Large Scale Mass Flow Measurement Using Bellmouth and Rake (벨마우스와 레이크를 이용한 대용량 유량 계측)

  • Kim, Jeong-Woo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.4
    • /
    • pp.70-79
    • /
    • 2012
  • For an aerodynamic test facility, it is very important to get the precise measurement data of pressure, temperature and mass flow rate at the upstream to the test article. Hence, a new measurement method using a bellmouth and rakes was studied for the large scale system of which the corrected mass flow is between 5 kg/s and 8 kg/s. The bellmouth was designed by ISO standard for 0.5% accuracy, and the rakes were designed by using the equal area method. From the results of 9 test trials, it is found that the Reynolds number of rakes and the mass flow rate ratio can be simply formulated by an one-dimensional equation. The mass flow rate of rakes was calibrated by this equation. By the result of calibration, The maximum error rate was -0.507%, and the average error rate was -0.000274%.

A Study on the Approximate model of the Flow rate Characteristics in External Gear pump for EHPS (전기 유압식 동력 조향시스템용 외접형 기어펌프의 유량특성 근사식에 관한 연구)

  • Kim, Ji-Hye;Kim, Sung-Gaun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.548-553
    • /
    • 2013
  • EHPS(Electro-Hydraulic Power Steering) is a system to generate the steering operation force from the electric motor connected directly to the oil pump. To optimize the manufacturing cost and efficiency of the performance of the steering system is very important. Until now, the development of the hydraulic system is implemented by the field test which needs a significant time and cost. In this paper, flow measurement of an external gear pump is performed. Then using the experimental results, an approximate model expressed by flow rate characteristics is proposed to calculate the discharge flow rate. Proposed approximate model is verified by comparing with the experimental data and AMESim results. As the experimental data and AMESim results agree well, the approximate model data can be used as an alternative to highly cost experimental procedure.

A Study on Performance Characteristics of Wetted-type Multi Path Ultrasonic Flowmeter (습식 다회선 초음파유량계의 특성평가 연구)

  • Lee, Dong-Keun;Cho, Yong;Ko, Jae-Myoung;Park, Tae-Jin;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.4
    • /
    • pp.5-9
    • /
    • 2013
  • An experimental investigation has been carried out in order to evaluate characteristics of wetted-type multi-path ultrasonic flowmeters. The multi-path ultrasonic flowmeters were installed at various entrance and exit locations for several cases of pipe fitting(straight, $90^{\circ}$ double elbow) and valve(gate valve, butterfly valve). We measured the flow-rate at each location. The measurement data of test flowmeter were compared with the measured data of reference flowmeter. The uncertainties of reference flowmeter and test flowmeter are 0.3 %, 0.4 %, respectively. The results demonstrate the effects of flowmeter location as well as the measurement errors in flow rate. The distance between the flow disturbance factor and a flowmeter was an important element of the test.