• Title/Summary/Keyword: 유량실증

Search Result 86, Processing Time 0.026 seconds

An Experimental Study on Variable-Speed Control of an Ground-Water Circulation Pump for a Ground Source Multi-Heat Pump System (주거용 건물 지열원 멀티 히트펌프시스템의 지열순환펌프 가변유량제어에 관한 실증연구)

  • Song, Suwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.443-449
    • /
    • 2013
  • The purpose of this study is to propose an enhanced variable-speed control method of ground-water circulation pumps using inlet and outlet ground-water temperature difference and analyze its effect for the ground source multi-heat pump system installed in a single-family house. As a result, it has shown to significantly reduce the electricity use of ground-water circulation pump and improve overall system Coefficient of Performance (COP) due to the proposed variable-speed control under partial load conditions after oversized and inefficient single-speed pump retrofit.

Demonstration of DC Electric Propulsion System for 10-ton Class Fishing Boat (10톤급 어선에의 DC 배전 전기 추진 선박 실증)

  • Son, Young-Kwang;Lee, Seong-Yong;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.110-111
    • /
    • 2019
  • 본 논문은 DC 배전 전기 추진 시스템으로 건조된 10톤급 소형 어선을 운항하며 계측한 실험 결과를 제시한다. DC 배전 선박과 모의된 AC 배전 선박을 일반적인 10톤급 소형 어선의 운용 패턴에 따라 운항하였고, 각 경우의 연료소모량을 유량계로 측정하였다. DC 배전 시스템은 가변속으로 인한 엔진의 효율적인 운전과 전기설비 무게 감소로 인한 추진 부하 감소의 효과로 AC 배전 시스템에 비하여 연료사용량이 약 20% 가량 절감된다. 실험 결과, DC 배전 전기 추진 선박을 적용할 시 연간 약 18,500L (22.0%)의 연료가 절감되어 연료비가 매년 약 1400만원 가량 절약될 것으로 예상된다.

  • PDF

Experimental Feasibility Study on Low-Temperature Differential Stirling Engines with Water Spray Heat Transfer (스프레이 열전달을 이용한 저온도차 스털링 엔진의 실험적 개념 연구)

  • Jang, Seon-Jun;Lee, Yoon-Pyo;Sim, Kyuho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.475-482
    • /
    • 2014
  • This paper presents the results of an experimental feasibility study on low-temperature differential Stirling engines with water spray heat transfer. The water spray enhances the efficiency of the heat transfer from heat sources to the engine and reduces the performance degeneration due to the dead volumes of conventional heat exchangers. A test Stirling engine was developed and an experiment was conducted to determine the characteristics for the initial start-up, steady-state operation, and power output for various flow rates and temperatures of hot supply water. The test results showed that larger flow rates led to reductions in the minimum working temperature of the hot water at start-up. During a series of steady-state operations, higher flow rates and temperatures increased the working speed. Furthermore, the work per cycle and power output were also increased. Eventually, the test Stirling engine had a power level of 0.05 W. Based on this, further research will be conducted to obtain a higher power output and investigate various applications.

Development for the Water Mist Package Having a Low Pressure Nozzles on Wooden Cultural Properties and Temples (중저압 노즐을 이용한 사찰 및 목조 문화재용 미분무 패키지 소화설비 개발)

  • Kim, Tae-Hwan;Myeong, Sang-Yeong
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.62-68
    • /
    • 2010
  • The present study purposed to develop the water mist package system for the cultural properties fire prevention and fire suppression system through analyzing fire protection system and cultural property's characteristic, and to suggest directions for the development of cultural property fire prevention system in the future. Maximum safety with minimum damage has issued a main objective in fire protection of the cultural property in Korea. Two types of the water mist nozzles having a low pressure had been developed by KEI. The one is for inside using in wooden cultural properties, the flow rate is 30~35 l/min and the discharging pressure is 13~14 bar. The other one is for out-side of wooden properties, the flow rate is 25~30 l/min and the discharging pressure is 14~15 bar. To evaluate the nozzles performance test, we made the fire scenario and full-scale model of wooden cultural properties for fire test. The size of full-scale model was 4.9 m length, 4 m wide, 6.6 m height, all was made by wooden. This real fire test results showed that the low pressure water mist nozzles having a $200{\mu}m$ dour size were very effectively fire extinguishing and suppression on wooden cultural properties fire. Even though the oil fuel fire was not extinguished, the fire suppression effects for the during mobilization of fire brigade was enough.

Development and Lab-scale Plant Study of Coagulation Sedimentation Module using Cyclone (선회류를 이용한 응집침전모듈의 개발 및 실증 연구)

  • Moon, Jinyoung;Cho, Young-Gun;Song, Seung-Jun;Kim, Jin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3336-3344
    • /
    • 2014
  • The purpose of this study is small scale coagulation module is developed and demonstrated through a lab-scale test. Recent as a sewage treatment rate increases, have heightened the interest in the necessity on the nonpoint source and developing a small processing unit has been increased. Coagulation sedimentation module in this study is additional growth of floc through swirling in the outside zone, reduction of microstructure floc number and the internal settling zone through vertical/level flow complex sedimentation method after the coagulation process precipitation method as an effective high separation efficiency can be divided was also assessed. Coagulation sedimentation module can increase the load factor was 4.4 times compared to conventional clarifier base on the same volume and surface area through vertical/level flow. In this study, this process was selected formation and maintenance of swirling and uniform flow distribution in the internal settling zone as an important design factor, to derive its FLUENT was used to characteristics of the flow model. Through the simulation of swirling, influent velocity, dimensions of external basin, hopper depth of bottom cone was determined and through analysis of velocity distribution, flow distribution detailed specifications are derived like as diameter and number of effluent hole. Lab-scale($120{\ell}/hr$) test results, influent of 300~800 NTU to less than 10 NTU without polymer feeding was able to operate in the 20minutes retention time(surface loading rate $37.3m^3/m^2$-day), and through analysis FLUENT the possibility of using design parameters were derived.

Study on Efficiency for Underground Heat Transfer of Metal Heat Exchanger (금속재질 열교환기의 지중 열교환 효율에 관한 연구)

  • Song, Jae-Yong;Kim, Ki-Joon;An, Sang-Gon;Kim, Jin-Sung;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.25 no.1
    • /
    • pp.131-148
    • /
    • 2015
  • The purpose of this study is to analyze and compare the heat transfer efficiency of using copper pipe, stainless pipe and traditional PE pipe commonly used for geothermal heat exchanger, with aims at seeking improved methods. In addition, the varying efficiency of heat transfer from ground heat and groundwater heat was assessed and its applicability was discussed. Design parameters for empirical field study were derived by controlling flow rate, velocity and caliber of pipes of the heat exchanger after the thermal efficiency of the heat exchanger material was evaluated. The heat exchange efficiency and effective thermal conductivity were measured with changing pattern through field thermal efficiency and thermal response test. Experimental results show that the metal material showed higher heat transfer efficiency than the PE pipe. Although the heat transfer efficiency was not high with the increase of the pipe diameter in the flow rate, it was high with the increase of the pipe diameter in the velocity.

Development of MBR System Commercialization Technology Using a Membrane with a Good Fouling Resistance (막 오염 저항성이 우수한 분리막을 이용한 MBR 시스템의 실증화 기술개발)

  • Choi, J.H.;Lee, J.B.;Kim, I.C.
    • Membrane Journal
    • /
    • v.18 no.1
    • /
    • pp.35-43
    • /
    • 2008
  • In this study, we tried to solve membrane fouling with membranes made by fine nano-particle in MBR process. And we confirmed good fouling resistance in pilot test. In this test, we confirmed our membrane with titania out-standing quality by testing in the pilot long-term test by comparing to other company product. Our membrane keep up steadily $20{\sim}25 L/m^2{\cdot}hr$ high flux in $7,000{\sim}13,000mg/L$ MLSS high sludge concentration. In addition to this quality, we studied membrane flux character related membrane arrangement, membrane-air line arrangement, air-line hole size, cleaning solution concentration, treatment method, etc. Using the optimization of this additional parameter, we tried to search method of maximizing membrane quality.

Flow Characteristics in a Real Scale Vegetation Patch using LSPIV Method (LSPIV 기법을 이용한 실규모 식생패치에서의 흐름특성)

  • Kim, Sung Jung;Kim, Hyung Suk;Ko, Dong Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.279-279
    • /
    • 2019
  • 본 연구는 안동 하천실증연구센터에서 수행된 RIED 실험의 일환으로 실험수로내 식재된 버드나무 식생패치의 밀도에 따른 표면흐름의 특성을 검토하는 실험이다. 실험의 목적은 식생의 침수수위에 따른 식생주변 및 하도의 흐름특성을 검토하는 것으로 침수 수위조건은 유량공급조건의 변화를 통해 재현하였다. 본 연구에 사용된 LSPIV 기법은 하도내 입자투여를 통해 영상을 이용하여 입자간 이동속도를 분석하여 흐름장을 분석하는 것으로 본 연구에서 사용된 입자는 강랭이를 사용하였으며, 영상촬영은 크레인을 이용하여 캠코더를 이용하여 수로 상부에서 흐름영상을 취득하였다. 실험수로는 저면폭 3m, 만제폭 11m 사면경사 1:2의 구조로 이루어진 사다리꼴 형태의 직선수로로 이루어져 있다. 식생패치는 동일수로내 상부기준 32m 간격으로 설치되어 있으며 패치의 크기는 $4{\times}1.5m$의 크기로 이루어져 있다. 그림 1은 상공에서 촬영된 영상을 나타낸 그림으로 실험수로 및 LSPIV 분석을 위해 투하된 입자를 나타내는 그림이다. PIV 분석프로그램을 이용하여 분석된 식생대 및 하도영역에서의 유속장은 그림 2와 같다. 영상분석은 30초영상(900 frame)을 이용하여 분석하였다. 실험결과 식생패치 설치지점에서는 주흐름이 발생하는 우안측에서 높은 유속이 발생하고 약간의 편향된 흐름이 나타나는 것으로 확인되었다. 식생후면에서는 식생으로 인한 흐름의 차단 및 스크린효과로 인해 유속의 저감되는 것을 확인할 수 있다. 밀도에 따른 패치 후면부에서는 높은 밀도를 갖는 첫 번째 패치에서 유속의 저감효과가 높게 나타났으나 유량조건에 차이가 발생하는 것으로 나타났는데 이는 수위상승으로 인한 식생의 침수면적과 관계가 있는 것으로 판단된다.

  • PDF

Analysis of water quality monitoring results during the rainfall period of Yeongju dam (영주댐 강우기 수질 모니터링 결과 분석)

  • Lee, Seungyoon;Shin, Cholong;Yi, Hye-suk;Chong, Sun-A
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.463-463
    • /
    • 2018
  • 우리나라의 공공용수역에서는 오염배출규제 및 하수도 정비에 의한 점오염원 부하량의 삭감에 의해 수질개선이 진행되어 왔다. 그러나, 비점오염원부하는 상대적으로 증가하는 경향에 있음에도 불구하고 그것을 실증하기 위한 강우시의 오염부하유출의 관측은 충분히 실시되지 않고 있다. 본 연구에서는 영주댐 유입하천을 대상으로 강우시 유입 오염부하량 파악 및 수질변동모의 예측을 위한 기초자료 획득을 위한 강우시 유입부하량 특성 및 수질영향이 분석되었다. 영주댐의 조사지점은 석표교, 멀내교의 총 2개 지점으로 본류인 내성천, 지류인 토일천에 각각 1곳씩 선정하였다. 유입수 샘플링은 자동모니터링 장치를 설치하여 채수하였고, 유랑조사는 교각에 설치된 자동수위측정기를 이용하여 측정하였다. 조사기간은 누적 강우량 133mm가 내린 2017년 7월 2일부터 5일간 실시하였다. 수질 시료 분석결과, 비강우시대비 COD 및 영양염류 부하량이 큰 폭으로 증가하는 것으로 나타났다. 토일천에서 채수된 시료의 경우 T-P는 비강우시 유입농도보다 최대 60배 높고, T-N은 비강우시에 비해 약 2.3배 높은 것으로 분석되었다. 강우유출 발생 시의 수질은 비강우시의 수질보다 COD 및 영양염류 부하량이 큰 폭으로 증가하였다. 비 강우시 유입되는 영양염류농도에 비해 강우시에는 강우강도에 비례하여 높은 농도의 인과 질소성분이 유입되고 있었고, 댐 저수량의 많은 부분이 강우시의 유입수량으로 채워지는 점을 고려할 때, 강우시 유입 수질이 댐 저수지 수질변화에 큰 영향을 주고 있을 것으로 판단된다. 영주댐 유역의 강우유출 특성은 강우유출이 시작 된 후, 수 시간 이내에 오염물질 농도가 급격히 증가하였고 유량의 증감속도와 유출량은 비례하였다. COD, 질소 계열 및 인 계열 물질의 유량과 비례한 증감을 확인하였다. 이를 통해 강우시 질소와 인의 유출이 강우량과 영향이 있음을 알 수 있었으나, 계절적인 유출 특성의 유무를 무시 할 수 없기 때문에 이에 대한 보다 상세한 조사 및 검토가 필요할 것으로 사료된다.

  • PDF

Prediction of Internal Tube Bundle Failure in High Pressure Feedwater Heater for a Power Generation Boiler by the Operating Record Monitoring (운전기록 모니터링에 의한 발전보일러용 고압 급수가열기 내부 튜브의 파손예측)

  • Kim, Kyeong-seob;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.2
    • /
    • pp.56-61
    • /
    • 2019
  • In this study, the failure analysis of the internal tube occurred in the high pressure feedwater heater for power generation boiler of 500 MW supercritical pressure coal fired power plant was investigated. I suggested a prediction model that can diagnose internal tube failure by changing the position of level control valve on the shell side and the suction flow rate of the boiler feedwater pump. The suggested prediction model is demonstrated through additional cases of feedwater system unbalance. The simultaneous comparison of the shell side level control valve position and the suction flow rate of the boiler feedwater pump compared to the normal operating state value, even in the case of the high pressure feedwater heater for the power boiler, It can be a powerful prediction diagnosis.