• Title/Summary/Keyword: 유량계측

Search Result 472, Processing Time 0.029 seconds

Accuracy Analysis of ADCP Stationary Discharge Measurement for Unmeasured Regions (ADCP 정지법 측정 시 미계측 영역의 유량 산정 정확도 분석)

  • Kim, Jongmin;Kim, Seojun;Son, Geunsoo;Kim, Dongsu
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.7
    • /
    • pp.553-566
    • /
    • 2015
  • Acoustic Doppler Current Profilers(ADCPs) have capability to concurrently capitalize three-dimensional velocity vector and bathymetry with highly efficient and rapid manner, and thereby enabling ADCPs to document the hydrodynamic and morphologic data in very high spatial and temporal resolution better than other contemporary instruments. However, ADCPs are also limited in terms of the inevitable unmeasured regions near bottom, surface, and edges of a given cross-section. The velocity in those unmeasured regions are usually extrapolated or assumed for calculating flow discharge, which definitely affects the accuracy in the discharge assessment. This study aimed at scrutinizing a conventional extrapolation method(i.e., the 1/6 power law) for estimating the unmeasured regions to figure out the accuracy in ADCP discharge measurements. For the comparative analysis, we collected spatially dense velocity data using ADV as well as stationary ADCP in a real-scale straight river channel, and applied the 1/6 power law for testing its applicability in conjunction with the logarithmic law which is another representative velocity law. As results, the logarithmic law fitted better with actual velocity measurement than the 1/6 power law. In particular, the 1/6 power law showed a tendency to underestimate the velocity in the near surface region and overestimate in the near bottom region. This finding indicated that the 1/6 power law could be unsatisfactory to follow actual flow regime, thus that resulted discharge estimates in both unmeasured top and bottom region can give rise to discharge bias. Therefore, the logarithmic law should be considered as an alternative especially for the stationary ADCP discharge measurement. In addition, it was found that ADCP should be operated in at least more than 0.6 m of water depth in the left and right edges for better estimate edge discharges. In the future, similar comparative analysis might be required for the moving boat ADCP discharge measurement method, which has been more widely used in the field.

A Study on Estimation of Hydraulic Coefficient in Ungaged Basin (미계측 유역의 수리계수 산정을 위한 연구)

  • Lee, Jong-So;Kim, Soo-Jun;Kim, Duck-Gil;Lee, Lim-Yeol;Kim, Hung-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.161-165
    • /
    • 2011
  • 수리계수는 하천의 수리학적 특성을 대표하는 인자라고 할 수 있다. 따라서 우리는 하천정비기본계획에 의하여 하천을 측량하고 그 측량성과를 바탕으로 수리계수를 산정하여 왔다. 이러한 수리계수는 하천의 홍수위, 유사량, 수질 산정을 위하여 중요한 매개변수로 활용할 수 있다. 하지만, 하천 측량성과가 없는 미계측 유역의 경우 수리계수를 산정할 수 없는 한계가 있는 것이 사실이다. 이러한 문제점을 극복하고자 SWAT 모형의 방법론을 검토하고 미계측 유역에서 수리계수를 산정하는 방안을 제시하고자 하였다. SWAT에서는 하도 단면을 사다리꼴로 가정하여 대상 유량에 대한 유속 및 수위를 산정하게 되는데, 이의 관계를 활용하면 유량-유속, 유량-수심에 대한 회귀방정식을 지수식으로 산정 할 수 있다. 본 연구에서 검토하고자 하는 방법론을 적용하고자 계측유역인 경안천 유역을 미계측 유역으로 가정하여 SWAT 모형을 적용하였다. 따라서 계측유역에 일반적으로 적용하는 방법인 HEC-RAS 모형을 이용한 수리계수 산정 결과와 본 연구에서 미계측 유역을 대상으로 적용하고자 하는 SWAT을 이용한 결과를 비교하였다. 비교결과 SWAT 모형을 이용한 방법론이 일반적인 방법론과 차이가 있음을 확인할 수 있었으며 이는 경안천이 자연하천이 아닌 정비된 제방하천이기 때문인 것으로 판단되었다. 따라서 자연하천에 대한 적용을 통한 검증 또는 제방하천에 대한 적용 방법의 개선이 필요할 것으로 판단되었다.

  • PDF

Applying regional regression analysis of the hydrologic model parameters for assessing climate change impacts in the ungaged watershed (미계측 유역의 기후변화 영향평가를 위한 수문모형 매개변수의 지역회귀분석 적용)

  • Kim, Youngil;Seo, Seung Beom;Kim, Sung Jin;Kim, Young-Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.219-219
    • /
    • 2017
  • 상대적으로 유역의 관측 자료가 충분하지 못하거나 검증되지 않았을 경우 미계측 유역으로 정의되며 수문모형의 매개변수 검정을 할 수 없으므로 다른 방법을 고안해야 한다. 이를 위해 기존 연구에서는 지역적 특성을 고려한 지역회기분석을 통해 미계측 유역의 유량을 산정하였는데, 대부분 유역의 특성과 연 평균 유출량 자료의 관계를 이용한 회귀식으로 실시간 유량의 변화를 고려하기 어려웠다. 본 연구에서는 개념적 강우-유출모형으로 많이 사용되고 있는 개념적 수문모형인 GR4J의 매개변수에 대해 미계측 유역의 특성을 고려한 변수들을 이용하여 회귀식을 구하고 그 적용성을 평가하였다. 이를 통해 미계측 유역의 유량 시계열 자료를 생성할 수 있었다. 또한 IPCC에서 발간한 AR5의 RCP 4.5 시나리오를 적용하여 미래 유출량을 산정하였다. 우선 지역회귀분석을 적용하기 위해 수문모형을 이용한 계측 유역의 유출량을 구하였으며 22개의 전국 댐 상류 지점을 기준으로 SCE 알고리즘을 이용하여 GR4J의 최적 매개변수를 구하고 각 유역별로 물리적, 지형적, 기상학적 특성을 고려하여 11개의 변수를 선택하였다. 각 변수간 다중공선성(Multicollinearity)를 고려하기 위해 VIF(Variation Inflation Factor) test를 적용하여 최종 7개의 변수를 선정하고 단계별 회귀방법(Stepwise regression)을 이용하여 GR4J의 매개변수별 회귀식을 생성하였다.

  • PDF

A Comparative Study on Direct Instrument Methods in Open Channel for Measuring River Water Usage (하천수 사용량 계측을 위한 개수로에서의 직접 계측방법 비교 연구)

  • Baek, Jongseok;Kim, Chiyoung;Lee, Kisung;Kang, Hyunwoong;Song, Jaehyun
    • Journal of Korean Society of Disaster and Security
    • /
    • v.13 no.4
    • /
    • pp.65-74
    • /
    • 2020
  • Continuous and accurate instrument of river water usage is needed for sustainable river water management. Although the instrument methods applicable to each point of use of river water are different, more precise direct instrument methods are required at the point of major open channel. Users of river water should select appropriate direct instrument methods to measure usage, but there is a lack of standards and verification research. In this study, the H-Q rating curve method, ultrasonic method, and microwave method were applied directly to the test basin in the upper basin of Mangyeong river, and the accuracy of measurement data was evaluated by comparing absolute error between discharge data calculated by instrument method. When comparing the calculated discharge of point units, the ultrasonic method showed the best results of the actual measurement. Through continuous instrument, the sum of the daily and monthly units was compared, and the ultrasonic and microwave methods were shown to be highly accurate. Based on the results of this study, it is hoped that the appropriate direct measurement method can be selected according to the importance of the river water use facility, considering that the ultrasonic method and the microwave method are relatively costly compared to the water level-flow relationship method.

Calculation of low flow for estimating TMDL (허용 부하량 산정을 위한 저수유량 산정 방안)

  • Jung, Yoon-Min;Kwon, Jae-Hyuk;Kang, Sang-Hyuk
    • Spatial Information Research
    • /
    • v.17 no.2
    • /
    • pp.223-239
    • /
    • 2009
  • The low fow analysis for small-mid sized river basins is very difficult because of insufficient flow data or ungauged basins. The objective of this study is to suggest effective method of low flow using area function method for calculating Total Maximum Daily Loads (TMDL) by considering environmental carrying capacity. Two watersheds which are Juchon watershed having $606km^2$ areas and ungauged watershed having $4,551km^2$ areas were selected for this study. As a result of application, the low flow in the downstream of Juchon River and the Han River after confluence of Okdong River were $1.9m^3/s$ and $20.7m^3/s$, respectively. Then we consider the target BOD of 1.0-1.2mg/l in Youngwol prefecture, the TDML was estimated 164-197kg/day and 1,788-2,146kg/day, respectively. This approach will useful for estimating TDML to insufficient watershed of flow data and ungauged watershed of flow data.

  • PDF

Runoff Forecasting at Ungaged Location (미계측 지점에서의 유출 예측)

  • Ahn, Sang Jin;Yeon, In Sung;Park, Jae Hyun;Lee, Mu Kyeong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.651-655
    • /
    • 2004
  • 하천의 수질은 시${\cdot}$공간적으로 지속적인 변화를 보이기 때문에 효과적인 수질관리를 위해서는 연속적인 하천수질 측정과 분석이 요구된다. 또한 유량과 수질측정이 동일시각에 이루어져야 하려 수질측정 지점에서의 보다 정확한 유량산정이 요구된다. 그러나 T/M 수위관측소와 수질자동측정망 지점이 원거리에 위치하여 수질자동측정망 지점에서 정확한 실시간 유량자료를 획득하기에 어려운 지점이 많다. 따라서 연구에서는 신경망 모형을 적용하여 미계측 지점에서의 유출량을 예측하고 강우-유출 모형인 WMS 모형에 의한 계산값과 비교하였으며 미계측 지점에서의 유출예측 가능성을 검토하였다.

  • PDF

Runoff Characteristics Analysis using GCUH on Ungauged Small Basin (지형기후학적순간단위유량도를 이용한 미계측 소유역의 유출특성 분석)

  • Lee, Sang-Jin;Choi, Hyun;Lee, Bae-Sung;Jeong, Dong-Kug
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.14 no.2 s.36
    • /
    • pp.15-22
    • /
    • 2006
  • Runoff Characteristics has been Analysis Using geomorphologic Instantaneous Unit Hydrograph(GIUH) and geomorphoclimatic unit hydrograph(GCUH) on an ungaged vary small basin about $5km^2$ scale in Kyungbuk gampo area. First, we estimated hydrology Factor using Geographic Information System(GIS) tool and then, calculated the characteristic velocity using the real rainfall-runoff data. It is compared with several velocities derived from GCUH theory and several other concentration time formulae. Kerby and Braby-Williams seems to be more applicable as characteristic velocity formula. Second, We compared the GCUH peak discharge with the probable flood, also compared the unit hydrograph as like the Clark, the Nakayasu and the S.C.S and GCUH with the observed discharge using the real rainfall events. The comparison results showed that GCUH could be applicable on an ungaged vary small basin. We expected that the result can be used as for estimation of a flash flood standard rainfall as well as emergency management plan.

  • PDF

Study on River Water Usage Calculation Method using Surface Velocity Sensor(RQ-30) (전자파표면유속계를 활용한 하천수 사용량 산정방법에 관한 연구)

  • Oh, Se Hwan;Song, Jae Hyun;Yoon, Young Sun;Roh, Young Sin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.255-255
    • /
    • 2022
  • 안정적이고 효율적인 물 배분과 관리를 위해 하천유량 외에도 하천수 사용량 파악에 대한 관심이 높아짐에 따라 다양한 하천수 사용량 계측방법의 검증 및 표준화로 하천수 사용량 자료의 신뢰도 및 활용성을 개선할 필요가 있다. 다양한 계측방법 중에서도 전자파표면유속계는 비접촉식 유속계이므로 안전적인 측면으로 유리하고 실시간 자료처리 및 계측이 용이하여 활용도가 높다. 본 연구에서는 만경강의 하천수 사용량 파악을 위해 어우보 취수로에 설치된 전자파 표면유속계(RQ-30)를 활용하여 보정계수(K-factor)가 적용된 표면유속을 활용한 유량산정방법, 표면유속과 평균유속의 일정비율로 유량을 산정하는 방법(ISO 748), Chiu의 유속분포법을 활용한 유량산정방법, 지표유속과 인력(人力)에 의한 측정유속과의 관계인 지표유속-평균유속관계곡선식으로 환산된 유량산정 방법등을 비교·검토하고 최적의 유량산정방법을 제시하였다. 향후 전자파표면유속계를 활용한 하천수 사용량의 비교결과를 통하여 더욱 효율적이며 신뢰도 높은 하천수 관리와 실시간 물배분 효과를 기대할 수 있다.

  • PDF

A Study on the Measurement of Gas Discharge from the Gas Vent of Sanitary Landfill(1)- analysis for minimizing the measurement error of flow meter - (쓰레기 매립지 가스포집관에서 유출가스 계측에 관한 연구(1) -유량계 계측오차의 최소화를 위한 해석 -)

  • 이해승;이찬기
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.1
    • /
    • pp.83-92
    • /
    • 1998
  • This study presents a relationship between gas quantity and measurement resistance using the bubble meter, the water head indicator and the rotor meter from the gas vent sanitary landfill. From the one-dimensional analyses and experiments, the below results have been obtained. The gas volume sourcing from the gas vent depends on the permeability of final cover soil, its cover depth and distance between the gas vents. The total gas volume producing in the interested domain may be accurately measured by the bubble meter, the water head indicator and the rotor meter if the clay is used for the final cover soil. The required times approaching to the steady-state are different with respect to the flow meters, one day is for the bubble meter and the water head indicator and one hour for the rotor meter.

  • PDF

Development of Hybrid Movable Weir for River Safety Management (안전한 하천관리를 위한 첨단 하이브리드 가동보 개발)

  • Kim, Phil Shik;Kwon, Hyung Joong;Park, Hyun Jun;Park, Chan Gi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.501-501
    • /
    • 2016
  • 하천은 크게 이수와 치수 및 환경 등의 주요 기능을 가지고 있다. 이수는 하천과 물이 주는 가치를 말하며, 치수는 기능이라기보다는 엄밀한 의미에서 하천관리를 통한 자연재해 방지를 의미한다. 이러한 이 치수 기능의 확보와 수변환경 조성을 위해 친환경적 수리구조물인 가동보의 설치가 증가 하고 있다. 가동보는 하천에 주로 설치되는 수리구조물 중의 하나로 국내에서는 2000년대부터 고정보를 대신하여 설치가 시작 되었으며, 최근 친환경적 하천정비 및 다양한 목적 등으로 국내 하천에 약 1,200여개의 가동보가 설치 및 운영되고 있다. 국내에 적용되고 있는 가동보 중 개량형 가동보의 제작 및 시공기술은 해외의 원천기술을 도입한 것으로 자재 수급 및 유지보수가 용이하지 못할 뿐만 아니라, 국내 여건에 맞지 않아 많은 문제점을 가지고 있다. 이에, 본 연구에서는 수자원 확보 및 수변 공간 조성 등을 위해 1) 기존 스틸소재의 개량형 가동보를 하이브리드(GFRP+스틸)소재로 개발하고, 2) 상류에 유하되는 이물질을 수위 저하 없이 하류로 배출하기 위해 각 경간의 개별 작동시스템을 개발하며, 3) 효율적인 하천 관리를 위하여 가동보 상단으로 월류 되는 하천 유량을 계측하기 위한 실시간 유량측정 시스템 개발 등으로 첨단 하이브리드 가동보를 개발하였다. 개발결과 기존 개량형 가동보의 단점인 부식해결로 인해 내구성을 확보하였으며, 경간별 개별 작동시스템 적용으로 하천 수위 조절이 가능하였다. 또한 실시간 유량 계측 시스템 적용으로 실시간 하천유량 계측이 가능해 개발된 기술을 국내 가동보에 적용한다면 원활한 하천 수위 관리 및 실시간 유량 측정이 가능하여 안전한 하천관리가 가능할 것으로 판단된다.

  • PDF