• Title/Summary/Keyword: 유량감소계수

Search Result 217, Processing Time 0.022 seconds

Application of Very Short-Term Rainfall Forecasting to Urban Water Simulation using TREC Method (TREC기법을 이용한 초단기 레이더 강우예측의 도시유출 모의 적용)

  • Kim, Jong Pil;Yoon, Sun Kwon;Kim, Gwangseob;Moon, Young Il
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.5
    • /
    • pp.409-423
    • /
    • 2015
  • In this study the very short-term rainfall forecasting and storm water forecasting using the weather radar data were implemented in an urban stream basin. As forecasting time increasing, the very short-term rainfall forecasting results show that the correlation coefficient was decreased and the root mean square error was increased and then the forecasting model accuracy was decreased. However, as a result of the correlation coefficient up to 60-minute forecasting time is maintained 0.5 or higher was obtained. As a result of storm water forecasting in an urban area, the reduction in peak flow and outflow volume with increasing forecasting time occurs, the peak time was analyzed that relatively matched. In the application of storm water forecasting by radar rainfall forecast, the errors has occurred that we determined some of the external factors. In the future, we believed to be necessary to perform that the continuous algorithm improvement such as simulation of rapid generation and disappearance phenomenon by precipitation echo, the improvement of extreme rainfall forecasting in urban areas, and the rainfall-runoff model parameter optimizations. The results of this study, not only urban stream basin, but also we obtained the observed data, and expand the real-time flood alarm system over the ungaged basins. In addition, it is possible to take advantage of development of as multi-sensor based very short-term rainfall forecasting technology.

The Effects of Fines on the Permeability in Sand Column (세립분의 함유량이 Sand Column의 투수성에 미치는 영향)

  • Lee Jean-Soo;Chang Yang-Chai
    • Journal of Navigation and Port Research
    • /
    • v.29 no.3 s.99
    • /
    • pp.263-268
    • /
    • 2005
  • Laboratory evaluation of the effect of fines, confine stress and dry density on the permeability characteristics in sand columns is presented. The triaxial permeability tests were conducted on different contents of fines(5, 15, 25, $35{\%}$), confine stress ($\sigma_3^'=0.5,\;1.0,\;2.0,\;3.0{\cal}kg/{\cal}cm^2$), and dry density($\gamma_d=1.50,\;1.55,\;1.60,\;1.65{\cal}g{\cal}cm^3$). The results of triaxial permeability tests showed that as the contents of fines, confine stress and dry density became increase permeability became decrease. For the contents of fines, when the fines that smaller than $0.01{\cal}mm$ increases the permeability decreases significantly. For the confine stress and the dry density, the permeability is decreased significantly at changes of the confine stress($\sigma_3^'=0.5{\~}1.0{\cal}kg/{\cal}cm^2$) and the dry density($\gamma_d=1.50{\~}1.55{\cal}g/{\cal}cm^3$) at lower levels.

The Mixed-Bed Ion Exchange Performance and Temperature Effects at Ultra-Low Concentrations - 2.Temperature Effects - (초저이온 농도범위에서 혼합층 이온교환능과 온도의 영향 - 2. 온도의 영향 -)

  • Yoon, Tae Kyung;Noh, Byeong Il;Lee, Chang Won;Moon, Byung Hyun;Lee, Gang Choon;Jo, Myung Chan
    • Applied Chemistry for Engineering
    • /
    • v.10 no.2
    • /
    • pp.206-211
    • /
    • 1999
  • Mixed-bed ion exchange performance was studied experimentally with variations of cation to anion resin ratio, resin weight and temperature at ultralow sodium chloride solution concentrations of less than $1.0{\times}10^{-4}M$. Analyzing the effluent concentration histories the performance test was examined as a function of tested solution volume for a laboratory-scale continuous flow column until both the cation and anion-exchange resins were exhausted. Initial leakage was observed for both cation and anion breakthrough curves, but serious at cation breakthrough curve because of low selectivity coefficient. The slope of breakthrough curve was affected by selectivity coefficient and temperature. The slope of anion breakthrough curve was steep because of the large selectivity coefficient, and ion exchange rates increased as temperature increased. The temperature effect decreased as the total volume was increased or as the resins were exhausted.

  • PDF

An Analysis of Characteristic for Hydrometeorologic Parameters Considering Climate Changes in Geum River Basin (기후변화를 고려한 금강유역 수문기상인자의 특성 분석)

  • Ahn, So-Ra;Park, Jin-Hyeog;Chae, Hyo-Seok;Hwang, Eui-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1555-1559
    • /
    • 2010
  • 본 연구는 미래 물 관리를 위한 기후변화 대응방안 도출 연구의 사전연구로서 금강유역의 과거 기상 수문요소의 특성변화 분석을 수행하였다. 기상자료로 금강유역 기상관측소 8개소의 37개년(1973~2009)의 기온, 강수량, 상대습도 자료를 수집하였다. 하천수위자료는 수위자료와 수위-유량관계곡선의 신뢰성 문제, 이후 수행될 장기유출분석을 고려하여 최종적으로 공주, 규암 수위관측소의 36개년(1973~2008)의 자료를 이용하였고, 지하수위자료는 강우관측소와 근접하게 위치해 있으면서 과거 자료를 최대한 많이 보유하고 있는 6개 관측소의 10개년(1999~2008)의 자료를 이용하였다. 수집된 자료의 평균, 표준편차, 왜곡도, 변동계수를 산출하여 연 계절별로 수문기상인자의 경년변화를 파악한 결과 기상인자 중 강수량의 변동성이 가장 크게 나타나 경년별 변화가 큰 것으로 분석되었고 하천수위보다는 지하수위가 경년별 변동이 적은 것으로 분석되었다. 수문학적 지속성 분석을 위해 Run 검정, Turning Point 검정, Anderson Exact검정을 이용하여 시계열자료에 주기성이 있는지 분석한 결과 기온과 강수는 무작위성, 상대습도, 하천수위는 지속성을 가지는 인자로 분석되었고 지하수위는 관측소별, 기간별로 무작위성과 지속성이 혼재되어 있는 것으로 나타났다. 마지막으로 경향성 분석을 위해 단순 선형 회귀분석과 Mann-Kendall 검정을 이용하였다. 그 결과 기온은 연 계절 모두 증가경향이 나타났고, 강수량은 여름에만 증가경향이 나타났으며, 상대습도는 뚜렷한 감소경향을 보였다. 또한 하천수위는 감소경향이 나타났으며 지하수위는 유의수준 범위에서 경향성은 보이지 않았다. 본 연구의 결과는 기후변화로 인해 발생될 수 있는 수자원의 영향을 평가하고 미래 물 관리 적응기술 개발 및 계획 수립을 위한 자료로 활용될 수 있을 것으로 사료된다.

  • PDF

An Experimental Study for Reduction of Energy losses at Surcharged Four-way Combining Square Manhole (과부하 4방향 사각형 합류맨홀에서의 에너지 손실 저감을 위한 실험 연구)

  • Kim, Jung Soo;Kim, Chae Rin;Yoon, Sei Eui
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.311-324
    • /
    • 2017
  • Energy loss at manholes under surcharged flow is considered as one of the major causes of inundation in urban area. Therefore, it is necessary to analyze the flow characteristics to reduce the energy loss in the surcharged four-way combining manhole. In this study, hydraulic experimental apparatus was constructed considering the results of the present survey. Square manholes and pipe diameters were reduced to 1/5 by applying sewer facility standards. Numerical simulations were carried out with the Fluent 6.3 model to derive the invert condition which can reduce the energy loss in the surcharged four-way combining square manhole. The hydraulic experiments were carried out according to the various conditions of the lateral flow rate($Q_{lat}/Q_{out}$), discharge of outflow pipe (2.0, 3.0, 4.0, 4.8 l/sec), and invert shape (rectangle and square open conduit type). The crossed invert was not found to improve the drainage capacity of the surcharged four-way rectangular combining manhole. However, the improved rectangle open conduit type invert and square open conduit type invert were analyzed to improve the drainage capacity by reducing the head loss coefficients by about 8% and 28%, respectively. Therefore, in order to increase the drainage capacity of urban facilities, it is possible to install and use the improved invert proposed in this study.

A Feasibility Study on Sewage Discharge Water Treatment for Water Reuse by Direct Contact Membrane Distillation (하수처리수 재이용을 위한 직접접촉식 막증발법 적용 가능성 연구)

  • Choi, Yongjun;Choi, Jihyuck;Shin, Yonghyun;Cho, Hyeongrak;Sohn, Jinsik;Lee, Sangho
    • Membrane Journal
    • /
    • v.26 no.1
    • /
    • pp.70-75
    • /
    • 2016
  • The reuse of wastewater is being diffused to manage and develop the water resources. Generally, the treated wastewater is discharged to the river after being treated to meet the effluent quality standard or reused for diverse uses through the reprocessing. And recently, as the reuse of the treated wastewater is activated, the technologies to utilize for the high quality water resources such as industrial water by reusing the wastewater with Membrane Distillation (MD) are under development. In this study, the direct contact membrane distillation (DCMD) process has been applied to treat sewage discharge water for water reuse. The laboratory scale experiment was performed by using a hydrophobic PVDF membrane with the pore size of $0.22{\mu}m$. The influence of operating parameters, such as feed temperature, feed flow rate, feed concentration, on the permeate flux and rejection has been investigated. All filtration tests were conducted till the feed volume reached a concentration factor of 3.0. Thus, the operating period ranged between 19 hr and 49 hr depending on filtration performance. The results showed that above 92% of TN, TP, COD and TOC in the feed could be rejected regardless of an operating condition. The water flux was ranged from 13.8 to 20.3 LMH. The lowest flux was obtained at the operating condition with the feed temperature of $50^{\circ}C$ and feed flow velocity of 500 mL/min while the highest one was measured with $60^{\circ}C$ and 900 mL/min. When the concentration factor reached 3.0, water flux declined by approximately ranged from 14.5% to 33.3%. But the fouling in MD is almost fully reversible, with more than 90% recovery of permeate water flux following a DI water rinse without the addition of chemical cleaning reagents.

Numerical Study on the Cooling Characteristics of a Passive-Type PEMFC Stack (수동공기공급형 고분자 전해질 연료전지 스택에서의 냉각특성에 대한 전산해석 연구)

  • Lee, Jae-Hyuk;Kim, Bo-Sung;Lee, Yong-Taek;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.8
    • /
    • pp.767-774
    • /
    • 2010
  • In a passive-type PEMFC stack, axial fans operate to supply both oxidant and coolant to cathode side of the stack. It is possible to make a simple system because the passive-type PEMFC stack does not require additional cooling equipment. However, the performance of a cooling system in which water is used as a coolant is better than that of the air-cooling system. To ensure system reliability, it is essential to make cooling system effective by adopting an optimal stack design. In this study, a numerical investigation has been carried out to identify an optimum cooling strategy. Various channel configurations were applied to the test section. The passive-type PEMFC was tested by varying airflow rate distribution at the cathode side and external heat transfer coefficient of the stack. The best cooling performance was achieved when a channel with thick ribs was used, and the overheating at the center of the stack was reduced when a case in which airflow was concentrated at the middle of the stack was used.

A study on the Derivation of GIUH-Clark Model (GIUH-Clark 모형의 유도에 관한 연구)

  • Lee, Byung Woon;Jang, Dae Won;Kim, Hung Soo;Seoh, Byung Ha
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.731-736
    • /
    • 2004
  • 강우-유출과정의 수문학적 현상을 보다 정확히 분석하고 예측하는 기법으로 강우에 의한 유출의 반응을 나타내는 지체시간, 도달시간 등 수문학적 반응시간을 유역의 지형형태학적 인자들과 연계하는 방법이 많이 이용되고 있다. 이에 본 연구에서는 Clark방법과 지형형태학적 순간단위도(GIUH)를 이용하여 계측유역의 강우-유출반응을 모의하였고, 이를 관측된 값과 비교하여 미계측유역의 적용성 여부를 검토해보았다. 대상 유역의 하상지형인자 및 지형형태학적 특성은 Arc-View를 이용하여 구하였으며, 이를 기존의 문헌자료와 비교해보았다. Clark방법의 매개변수의 결정에 있어서 시간-면적곡선은 HEC-1의 무차원 식을 이용하였고, 도달시간은 Kirpich 공식을 이용하여 구하였으며, 저류상수는 Clark방법에 의해 추정된 순간단위도의 첨두유량이 Horton의 차수비의 함수로 구한 철두유량과 같아지는 값으로 결정하였다. 본 연구는 전적비교를 출구점으로하는 유역면적 $8.5km^2$인 설마천을 대상유역으로 하였으며, 모의된 강우-유출반응과 비교하기 위해 사용된 강우사상은 2002년의 8월 4일과 2002년 10월 6일의 10분 단위 우량이다. Clark방법과 GIUH를 이용하여 모의한 유출곡선과 관측된 유출곡선을 비교해본 결과 첨두유량은 8월의 강우사상 때는 $21\%$크게, 10월의 강우사상 때는 $35\%$작게 나타났다. 첨두시간은 모의된 경우가 각각 10분, 20분 빨리 도달하였다. 또한 이러한 결과는 유역의 도달시긴에 가장 민감하게 반응함을 알 수 있었다. 따라서, 유역의 도달시간 산정에 주의를 요한다면 프랙탈 차원이 유사한 미계측유역의 수문곡선 산정에 있어서 Clark방법과 GIUH를 이용하는 방법도 유용하다고 사료된다. 주는 각 수문인자 중 강우시간분포와 유효우량 산정방법 그리고 유출모형에 대해 자자 검토하였으며, 최종적으로 면적에 따른 임계지속기간과 유출량의 변화를 검토해 보았다.이를 각각의 경우의 해석해 결과와 비교${\cdot}$분석하였다. 후방추적 퍼프모형은 전방추적 퍼프모형에 비하여 사용된 퍼프수와 관계없이 작은 오차를 발생하였으며, 전체적으로 퍼프 모형이 입자모형보다는 훨씬 적은 수의 계산을 통해서도 작은 오차를 나타낼 수 있다는 것을 알 수 있었다. 그러나 Gaussian 분포를 갖는 퍼프모형은 전단흐름에서의 긴 유선형 농도분포를 모의할 수 없었고, 이에 관한 오차는 전단계수가 증가함에 따라 비선형적으로 증가하였다. 향후, 보다 다양한 흐름영역에서 장${\cdot}$단점 분석 및 오차해석을 수행한 후에 각각의 Lagrangian 모형의 장점만을 갖는 모형결합 방법을 제시할 수 있을 것으로 판단된다.mm/$m^{2}$로 감소한 소견을 보였다. 승모판 성형술은 전 승모판엽 탈출증이 있는 두 환아에서 동시에 시행하였다. 수술 후 1년 내 시행한 심초음파에서 모든 환아에서 단지 경등도 이하의 승모판 폐쇄 부전 소견을 보였다. 수술 후 조기 사망은 없었으며, 합병증으로는 유미흉이 한 명에서 있었다. 술 후 10개월째 허혈성 확장성 심근증이 호전되지 않아 Dor 술식을 시행한 후 사망한 예를 제외한 나머지 6명은 특이 증상 없이 정상 생활 중이다 결론: 좌관상동맥 페동맥이상 기시증은 드물기는 하나, 영유아기에 심근경색 및 허혈성 심근증 또는 선천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히 교사들이 중요하

  • PDF

Analysis of Intercepted Discharge Considering the Change of Street Inlet Size (빗물받이 유입구 크기 변화에 따른 차집유량 분석)

  • Kim, Jung Soo;Ryu, Teak Hee;Rim, Chang Soo;Yoon, Sei Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.375-375
    • /
    • 2015
  • 최근 도시화에 따른 도로구역의 증가는 도심지의 불투수면적의 확대 및 도로의 수로화를 야기하여 집중호우 발생 시 노면 및 저지대의 침수를 가중시키고 있으며, 이로 인한 인명피해 및 재산 피해는 점차 증가하는 추세이다. 이에 기후변화에 따른 강우량의 변화 및 국지성 집중호우 등을 고려하고 도심지 침수 방지 및 방재성능 강화를 위하여 과거에 간선 10년, 지선 5년에서 간선 30년, 지선 10년으로 관거의 설계빈도가 상향조정 되었다. 도심지의 도로 및 유역 유출량의 배수에 상당한 영향을 미치는 빗물받이 및 빗물받이 유입구는 도심지의 방재성능강화 목적에 맞는 설계가 이루어져야 하나 현재 국내의 빗물받이 설치기준은 하수도시설기준(2009, 환경부)에서 '빗물받이 크기별, 도로 차선별 적정 빗물받이 설치간격' 으로 설계빈도 5년을 반영하여 제시된 설치기준이므로 이에 대한 수정 및 개정이 필요한 실정이다. 이에 본 연구에서는 관거시설의 설계빈도 상향을 고려한 도로 빗물받이의 유입량 산정을 위해 빗물받이 유입구 크기별 유입량을 도로의 차선, 종경사, 측구 횡경사 및 설계빈도의 변화를 고려하여 도로에서의 유출량을 산정하였으며, Froude 상사법칙을 이용하여 수리실험모형을 제작하여 실험을 실시하였다. 빗물받이 제원은 현재 대부분의 국도에 설치되는 크기인 $40{\times}50cm$, $40{\times}100cm$$40{\times}150cm$를 축소 제작하였다. 측구의 유량은 도로의 차선(2~4차선), 경사(도로 종경사 2~10%, 측구 횡경사 2~10%) 및 설계빈도(최대 30년)을 고려하였다. 실험 결과 측구의 횡경사가 커질수록 빗물받이로 유입되는 유량은 증가하였으며, 빗물받이 유입부의 길이가 증가함에 따라 유입부 측면부를 통한 횡유입량을 증가시켜 빗물받이 유입부의 차집율을 증가시켰다. 또한, 도로의 조건 변화 및 유입량의 변화에 따라서 흐름폭이 감소할수록 차집율이 증가하였다. 수리실험결과를 토대로 도로의 조건변화(차선, 도로 종경사, 측구 횡경사) 및 설계빈도 변화를 고려한 빗물받이의 차집율을 제시하였고 이를 회귀분석 하여 빗물받이 유입구 크기별 유입량 산정식을 도출하였다. 이는 설계빈도 상향에 따른 국내 빗물받이 유입부의 설계 기준 제시에 기초자료로 활용이 가능할 것으로 판단된다.

  • PDF

Assessment of Water Quality and Pollutant Loads on Agricultural Watershed in Jeonbuk Province (전북지역 농업용 하천유역의 수질과 부하량 특성)

  • Uhm, Mi-Jeong;Moon, Young-Hun;Ahn, Byung-Koo;Shin, Yong-Kyu
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.2
    • /
    • pp.111-119
    • /
    • 2008
  • This study was conducted to evaluate water quality and pollutant loads on small agricultural watershed in Jeonbuk province. The EC level of investigated watershed ranged from 0.07 to 0.52 dS/m, BOD level ranged from 0.1 to 5.0 mg/L, and $COD_{Cr}$ level ranged from 0.6 to 17.7 mg/L. As above, contents of water quality indicators covered wide range, but each indicator was alike in mean content every other year. The contents of EC, $Ca^{2+},\;Mg^{2+},\;K^+\;and\;Na^+$ were decreased in rainy season, but the contents of BOD, $COD_{Cr},\;COD_{Mn}$, T-N and T-P were not greatly different as compared to dry season. And high content of SS showed substantial sediments near the surface flow out and influence on water system in rainy season. The pollutant loads measured in terminal of watershed were $9.6{\sim}757.9$ kg/day for BOD, $51.2{\sim}1418.5$ kg/day for T-N and $0.3{\sim}44.7$ kg/day for T-P. The pollutant loads of BOD, T-N and T-P in rainy season increased several times as compared to dry season. In rainy season, watershed with more than 30% in the proportion of paddy field to land showed relatively low discharge and pollutant loads in comparison to watershed with less than 30%. The discharge of watershed in rainy season increased 5.7times compared with the dry season in watershed with less than 30% in the proportion of paddy field to land, whereas was only 2.3times in watershed with more than 30%. The correlation coefficient($R^2$) of regression between discharge and pollutant loads of T-N were higher than those of BOD and T-P.