In general, an impeller of centrifugal turbomachinery is designed at isolated condition without considering the presence of a volute, but when the impeller is operating with its volute, the performance of impeller can be different. This is largely caused by the interaction between the impeller and volute flow fields. The magnitude of distortion is increased as the operating point is away from the design point and, as a result, the interaction between the impeller and volute is stronger. In the present calculation, the flow through the impeller is simulated using coarse grids. The flow within the impeller and the volute is naturally unsteady, but the flow is assumed to be steady across the interface between the volute and impeller flow fields. Under the assumption of steady three-dimensional incompressible turbulent flow, the time averaged N-S equations involving standard k-$\epsilon$ turbulent model was solved by the F.V.M. The calculation results are compared with the experimental results obtained for an industrial fan by Sakai etc. and the Hood agreement is demonstrated. And the effects of the impeller-volute interaction are studied.
As air pollution becomes more serious due to the increased number of diesel vessel operations, ship regulations on harmful emissions strengthen. Therefore, the development of a diesel exhaust after-treatment system for ships is required, and the higher the flow uniformity of the exhaust treatment system, the higher the treatment efficiency. With the computer software ANSYS Fluent, pressure drop and flow uniformity were used in this study to simulate flow rate with and without a baffle in both a Diesel Oxidation Catalyst (DOC) and Diesel Particulate Filter (DPF) system. The system pressure drop was found to be 38 to 40 mbar in the existing system condition, and the flow uniformity was approximately 84 to 92% at the inlet and outlet of the DOC. When the baffle was installed inside the system, the pressure increased and the flow uniformity was lowered due to an increase in flow rate. When the exhaust gas flow was reduced by 50% from $7,548kg\;h^{-1}$ to $3,772kg\;h^{-1}$, the flow uniformity at the inlet and outlet of the DOC increased by approximately 1 to 3% due to the low flow rate. In the case of DPF, the flow uniformity of exhaust gas was 98 to 99% because the uneven flow proceeded after uniformly flowing from the DOC.
Korean Journal of Air-Conditioning and Refrigeration Engineering
/
v.12
no.9
/
pp.802-809
/
2000
This study numerically analyzes the thermal and flow characteristics inside the header in PFHE(parallel-flow heat exchanger) by employing a three-dimensional turbulence modeling. The following quantities are examined by varying the injection angle of the working fluid, the location of entrance and the shape of entrance: flow nonuniformity, heat transfer rate, and flow distribution in each passage. The result shows that the degree of significance among the parameters affecting the header part is in the order of the injection angle, the shape of entrance, and the location of entrance. The result also indicates that heat transfer rates compared to the reference model are increased by about 152% for the angle of injection of -$20^{\circ}C$, by about 127% for the shape of entrance with right and left long rectangular form, and by about 108% for the location of entrance located at the lowest Position.
Journal of the korean Society of Automotive Engineers
/
v.10
no.2
/
pp.15-22
/
1988
실제의 흡기관에서는 단면이 일정한 직관이 아니며, 피스톤기관의 흡기관은 단면변화가 불가피하여 액적은 소성으로 인한 관벽과의 충돌로 부착하게 되고 액적부유율은 더욱 작게 된다는 D.A. Trayser, W.E. Ranz등의 보고가 있다. 또 보제행남들은 액막류의 발생이 유해배기 가스를 증가시키고 액막류의 감소는 기통사이의 연료분배의 불균일도를 저하시키므로 NOx, HC, CO가 크게 감소된다고 보고하였다. 이와같이 액막유의 존재는 각 실린더에 유입하는 연료의 질적차이를 가져오기 때문에 액막유를 분리제거하는 방법의 연구도 많이 이루어지고 있으나 아직 실용상에 문제가 많은 것으로 남아있다. 따라서 본 고에서는 이와같이 문제되고 있는 흡기관내 액막유동의 거동을 고찰하기 위하여 액막두께 변동을 측정하는 방법에 대하여 저자들이 사용하였던 방법과 그외 초음파를 이용한 액막두께 측정법을 소개하고자 한다.
본 연구는 '초고층 아파트 최적 설비시스템 개발'의 제2차년도 연구로서 아직까지 국내에서 확립되어 있지 않은 초고층 아파트 급수설비 시스템 및 수격방지 시스템의 모델정립과 연돌효과에 의한 열손실 추정 및 적정 설계 지침 설정에 관한 연구를 수행하였다. 이를 위하여 이론 해석 및 현장실험을 수행하였고, 결과분석을 통하여 최적화 설계방안도 아울러 도출하였다. 급수설비 분야에서는 각종 급수 시스템의 해석 및 비교를 통한 효율적인 시스템의 설계 및 선정방법을 제시 하였고, 실제 초고층 아파트에 대한 수격현상 해석 및 실험을 통하여 수격작용의 영향을 감소시킬 수 있는 설계방안을 검토하였다. 또 입주중인 초고층 아파트 현장에서의 실측을 통하여 건물의 높이에 따라 불균일한 틈새가 있는 일반적인 경우에 대한 모델을 정립하였고, 수치해석을 통한 수직통로 내의 실제 열유동 현상을 정량화하고 설계지침을 제시하였다. 결과로서 각종 급수시스템의 해석을 위한 프로그램을 개발하였고, 수격의 발생을 억제하기 위한 최적 밸브 폐쇄형태를 제시하였으며, 초고층 건물의 내외부에 형성되는 압력차와 유인풍량 및 열손실량 사이의 관계식을 얻었다.
Transactions of the Korean Society of Mechanical Engineers B
/
v.25
no.12
/
pp.1784-1792
/
2001
Numerical analysis on a parallel flow heat exchanger(PFHE) is performed using 2 dimensional turbulent porous modeling. This modeling can consider three-dimensional configuration of passage (flat tube with micro-channels), and the stability and accuracy of numerical results are improved. The geometrical parameters(e.g., the position of separators, inlet/outlet, and porosity of passages of a PFHE) are varied in order to examine the flow and thermal characteristics and flow distribution of the single phase multiple passages system. The flow non-uniformities along the paths of the PFHE are observed to evaluate the thermal performance of the heat exchanger. The location of inlet affects the heat transfer, and the location of outlet affects the pressure drop. The porosity with the optimum thermal performance is around 0.53.
플라스틱은 가공이 용이하기 때문에 우리 생활에 널리 이용되고 있다. 과거에는 단순히 제품의 외장제로 이용되었지만 산업이 발달함에 따라 금속을 대체 할 정도로 사용 범위가 증가하고 있다. 또한 사용량이 증가함에 따라 제품의 생산량을 증가시키기 위해선 다수 캐비티의 금형 사용이 필수적으로 되었다. 다수 캐비티 사출성형에서 각 캐비티 간 제품의 품질 및 물성을 향상시키기 위해선 각 캐비티로 충전되는 수지가 균형을 이루어야 한다. 하지만 기하학적으로 균형을 갖추고 있는 러너를 설계하여도 실제 사출성형에서는 불균형 충전이 일어나게 된다. 이러한 불균형 충전은 미국의 Beaumont에 의해서 처음 규명된 뒤 충전불균형 현상을 해결하기 위해 많은 연구가 진행되었다. 본 논문에서는 다수 캐비티 사출성형에서 균형충전을 위한 러너시스템을 제안하였다. 이 러너시스템은 온도가 불균일한 수지의 흐름을 혼합함으로써 수지의 흐름을 균일하게 하여 균형충전을 이루도록 하였다. 또한 사출성형해석프로그램인 Moldflow를 이용한 유동해석을 통해 그 효과를 나타내 보았다.
태양열 시스템에 사용되는 간접접촉을 열교환기는 열전달률감소, 부식, 스케일링 등의 문제에 기인하는 단점을 갖고 있다. 이러한 문제들을 해결하기 위하여 직접접촉 열교환기의 사용이 제안된다. 본 연구에서는 직접접촉 열교환기로서 분사칼럼이 도입되었다. 열전달률을 증가기키기위하여 작동유체는 연속유체와의 접촉면적을 증가시키기위하여 칼럼내에서 작고 균일한 방울들로 분산된다. 또한 작고 균일한 방울들로 만들기 위하여 열교환기 칼럼내에서 메쉬가 설치되었다. 디에틸 프탈레이트(Diethyl Pthalate , 밀도 : 1,052g/㎤)가 작동유체로 사용되었고, 메쉬가 있는 경우와 없는 경우로 비교 실험되었다. 실험중 칼럼의 길이방향으로 온도측정을 하였고, 두 유체간의 직접접촉 열교환 메카니즘을 알기 위하여 방울의 사진을 통하여 분석하였다. 방울이 제트형태로 형성될 때 방울은 작고 균일하였다. 한편 방울형태로 형성될 때는 크고 불균일하게 관찰되었으나 , 메쉬를 통해 칼럼내에서 효과적으로 작고 균일한 방울들로 되었다.
Transactions of the Korean Society of Mechanical Engineers B
/
v.22
no.2
/
pp.229-239
/
1998
The present paper examines the thermal and flow characteristics of a parallel flow heat exchanger and investigates the effects of the parameters on thermal performance by defining the flow nonuniformity. Thermal performance of a parallel flow heat exchanger is maximized by the optimization using Newton's searching method. The flow nonuniformity is chosen as an object function. The parameters such as the locations of separator, inlet, and outlet are expected to have a large influence on thermal performance of a parallel flow heat exchanger. The effect of these parameters are quantified by flow nonuniformity. The results show that the optimal locations of inlet and outlet are 19.73 mm and 10.9 mm, respectively. It is also shown that the heat transfer increases by 7.6% and the pressure drop decreases by 4.7%, compared to the reference model.
Transactions of the Korean Society of Mechanical Engineers B
/
v.24
no.5
/
pp.640-651
/
2000
For the heat and fluid flow analyses of a parallel flow heat exchanger, an improved model considering the effect of flat tube with micro-channels is proposed. The effect of flow distribution on the thermal performance of a heat exchanger is numerically investigated. The flow distribution is examined by varying geometrical parameters, i.e., the position of the separators and the inlet/outlet, and the aspect ratio of micro-channels of the heat exchanger. The flow nonuniformities along the paths of the heat exchanger are proposed and observed to evaluate the thermal performance of the heat exchanger. The optimization using ALM method has been accomplished by minimizing the flow nonuniformity. It is found that the heat transfer rate of the optimized model is increased by 6.0% of that of the reference heat exchanger model, and the pressure drop by 0.4%
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.