• Title/Summary/Keyword: 유동 계수

Search Result 1,311, Processing Time 0.035 seconds

Efficient Analysis of the Aerodynamic Characteristics of Rotor Blade Using a Reduced Order Model Based on Proper Orthogonal Decomposition Method (적합직교분해를 이용한 로터 블레이드의 차수축소모델 구축 및 공력특성 분석)

  • Jung, Sung-Ki;Duc, NgoCong;Yang, Young-Rok;Cho, Tae-Hwan;Myong, Rho-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.11
    • /
    • pp.1073-1079
    • /
    • 2009
  • The proper orthogonal decomposition (POD) method can identify principal modes that optimally capture the energy content from large multi-dimensional data set. In this study unsteady pressure fields on the rotor blade surface of a helicopter in forward flight are expressed by a reduced order model based on the POD method. Special modes containing high energy are analyzed to investigate the aerodynamic characteristics in more efficient way. The CFD simulation of flowfields around helicopter rotor blade in hovering motion is also conducted to validate its prediction with experimental result. In the process 7 modes containing energy ratio 99% from 240 snapshots information are identified and utilized to construct a reduced order model.

A Study on Entrance Section of Hybrid Wave Power Generation System (하이브리드형 파력발전시스템의 유입구 형상 연구)

  • Oh, Jin-Seok;Jang, Jae-Hee
    • Journal of Navigation and Port Research
    • /
    • v.37 no.6
    • /
    • pp.597-601
    • /
    • 2013
  • Recently, many studies about the wave power generation system for the marine structure as the hybrid form in linked with the original features have been made of. Of these, the wave power generation system using oscillating water column(OWC) has function to convert wave energy to electrical energy with original function of the break water structure. In this type of generation system, it is important to make the flow of sea water as much as possible without loss. Output characteristics of wave power generation system depending on entrance section were described in the paper. Also, flow quantity changing with entrance section, velocity of sea water and output of wells turbine were measured by simulating OWC wells turbine model in break water, one of the general marine structure. Finally, entrance section was suggested to enhance the energy conversion efficiency based on the results of simulation.

Performance analysis of a cold-air forced circulation type showcase (냉기 강제순환형 공랭식 쇼케이스 성능 해석)

  • Kim, Jeong-Sik;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1003-1010
    • /
    • 2013
  • In this study, a simulation program was developed, which predicts the performance of cold-air forced circulation type air cooled showcase. The showcase has an excellent display effect in addition to preserving the grocery. In the program, the compressor was analyzed using performance data supplied by the manufacturer and the capillary tube pressure drop was analyzed using a homogeneous model. The evaporator and condenser were analyzed by dividing the heat exchangers into small elements, where energy balance and appropriate heat transfer correlations were used. A showcase model with two 3/4 HP compressors, capillary tubes of 1.6 mm inner diameter, a fin-and-tube evaporator and condenser was tested, and the results are compared with the predicted values. It is shown that both evaporation and condensation temperatures are adequately predicted by the program.

Characterization of Acryl Polymer Concretes for Ultra Thin Overlays (초박층 덧씌우기용 아크릴 폴리머 콘크리트의 특성 연구)

  • Kim, Dae-Young;Kim, Tae-Woo;Lee, Hyun-Jong;Kim, Hyung-Bae
    • International Journal of Highway Engineering
    • /
    • v.12 no.3
    • /
    • pp.1-8
    • /
    • 2010
  • This study is performed to evaluate the physical and mechanical characteristics of an acryl polymer concrete that is developed as an overlay material for cement concrete slabs and pavements. Various laboratory tests including viscosity, flow, compressive strength, flexural strength, tensile strength, linear shrinkage, thermal expansion and thermal compatibility tests are performed. It is observed from the laboratory tests that the acryl polymer concrete developed in this study satisfies all the requirements suggested by ACI guideline. In addition to the laboratory tests, an accelerated performance testing (APT) is conducted to validate the performance of the acryl polymer concrete. During the APT, no significant distresses are observed until 15,903,939 cycles of equivalent single axle loading is applied. Finally, a 10mm thick overlay with the acryl polymer concrete is applied on top of an old deteriorated concrete pavement to evaluate field performance. Right after the field construction, skid resistance, noise and roughness are measured. The skid resistance and noise level have been significantly improved while the roughness is increased. Periodic investigation for the field study section will be conducted to evaluate the long-term performance.

A study on bias effect of LASSO regression for model selection criteria (모형 선택 기준들에 대한 LASSO 회귀 모형 편의의 영향 연구)

  • Yu, Donghyeon
    • The Korean Journal of Applied Statistics
    • /
    • v.29 no.4
    • /
    • pp.643-656
    • /
    • 2016
  • High dimensional data are frequently encountered in various fields where the number of variables is greater than the number of samples. It is usually necessary to select variables to estimate regression coefficients and avoid overfitting in high dimensional data. A penalized regression model simultaneously obtains variable selection and estimation of coefficients which makes them frequently used for high dimensional data. However, the penalized regression model also needs to select the optimal model by choosing a tuning parameter based on the model selection criterion. This study deals with the bias effect of LASSO regression for model selection criteria. We numerically describes the bias effect to the model selection criteria and apply the proposed correction to the identification of biomarkers for lung cancer based on gene expression data.

A Study on the Prediction of Groundwater Contamination using the GIS in Hwanam 2 Sector, Gyeonggi Province, Korea (GIS를 이용한 경기도 화남2지구의 지하수오염 예측에 관한 연구)

  • Son, Ho-Ung
    • The Journal of Engineering Research
    • /
    • v.5 no.1
    • /
    • pp.89-107
    • /
    • 2004
  • This study has tried to develop the modified DRASTIC Model by supplying the parameters, such as structural lineament density and landuse, into conventional DRASTIC model, and to predict the potential of groundwater contamination using GIS in Whanam 2 Area, Gyeonggi Province, Korea. Since the aquifers in Korea is generally through the joints of rock-mass in hydrogeological environment, lineament density affects to the behavior of groundwater and contaminated plumes directly, and land-use reflect the effect of point or non-point source of contamination indirectly. For the statistical analysis, lattice layers of each parameter were generated, and then level of confidence was assessed by analyzing each correlation coefficient. Composite contamination map was achieved as a final result by comparing modified DRASTIC potential and the amount of generation load of several contaminant sources logically. The result could suggest the predictability of the area of contamination potential on the respects of hydrogeological aspect and water quality.

  • PDF

Heat transfer characteristics with materials of the filler and flow path in vehicle washer heater system (차량워셔액 가열시스템에서 충전재 및 유로의 재질에 따른 열전달 특성 연구)

  • Cha, Woo Sub;Kim, Tae Kwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2628-2634
    • /
    • 2014
  • Vehicle washer heater system is more widely adopted to defrost a window or to clear the windshield glass in winter season. The washer heater system should be designed to heat up washer fluid rapidly to the target temperature for only a short time. A numerical analysis has been carried out to analyze the heat transfer characteristics with materials of inside parts in vehicle washer heater system with filler and flow path. ANSYS - FLUENT software is employed for the analysis. The axial symmetry model is three-dimensional and unsteady. It applies to the coupled method which is one of pressure based. Through this result, it was obtained to find the optimal material condition for the filler and flow path in washer system. For material of filler, the air with lower density was heated more rapidly rather than silicon carbide(SiC). For material of flow path, copper with the heat transfer coefficient of approximately four times greater than the nickel gives us higher efficiency. That is the reason why the heating time of methanol was reduced to make uniform temperature in washer heater system.

Applicability Evaluation of Using Logarithmic velocity law for Assessing Local Shear Stress in Straight and Meandering River Channel (직선 및 사행 하천에서의 대수법칙를 이용한 국부 소류력 산정 적용성 검토)

  • Kim, Jong Min;Kim, Dong Su;Son, Geun Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.172-172
    • /
    • 2015
  • 하천에서 발생하는 소류력은 하상 변동을 발생시키기 때문에 주변 구조물이나 하천의 흐름특성 등을 변화시키게 되며, 유사이송, 침식 및 퇴적, 유동해석 등에 매우 중요한 하천 계수이다. 하천에서 소류력의 직접 측정은 매우 어려워 직접 측정 대신 하천경사 및 동수반경을 기반한 단면 평균소류력 산정 공식을 일반적으로 이용한다. 그러나, 이러한 방식은 상세한 유사이송, 세굴 등의 해석에는 한계가 있기 때문에 국부적인 소류력이 필요하다. 실내 실험에서는 프레스톤게이지를 활용한 직접 측정이나, 난류측정을 통한 레이놀즈 분포를 외삽하여 단면에서 국부적인 소류력을 측정하는 방식이 사용되어 왔다. 반면, 실제 하천에서는 국부 소류력 직접측정 및 난류 산정이 거의 불가능하거나 비효율적이므로 대안으로 하천의 연직유속분포에 대수분포를 적용하여 소류력을 추정하는 간접적인 방법이 제시되어 왔다. 일부 실내실험에서 대수법칙을 통한 소류력 산정 방식은 직접 측정을 통해 검증한 바가 있으나 실제 하천은 난류의 공간 시간적 스케일이 실내 규모와 상이하여 국부 소류력에 영향을 미칠 수 있어 이러한 검증결과를 현장 적용하기에는 한계가 있다. 본 연구에서는 실제 규모 하천에서 대수법칙을 활용한 국부 소류력 산정 결과와 레이놀즈 응력의 연직분포 측정을 통해 산정한 값과 비교하여 대수법칙 활용 소류력 산정 방식의 적용성을 검토하였다. 실험은 중소규모의 하천을 재현한 한국건설기술연구원 안동하천실험센터 직선(A1) 및 사행(A2) 하천의 유속측정을 수행하였으며, 유속 측정에는 정밀도가 높으나 실내에서 주로 사용된 초음파지점유속계(Micro ADV)를 현장에 설치하여 사용하였다. ADV의 관측 시간은 90초이며, 직선수로에서는 횡방향으로 25 cm 간격, 수심방향으로는 5 ~ 10 cm 간격으로 측정하였고, 사행수로는 횡방향으로 50 cm 간격, 수심방향 5 ~ 10 cm 간격으로 측정을 수행하였다. 실험결과 대수법칙과 레이놀즈 분포로부터 산정된 국부 소류력은 사행과 직선 모두 상당한 이격을 보였다.

  • PDF

1D Numerical Simulation of Geyser Phenomenon in Storm Drainage using Modified Preissmann Slot Model (Modified Preissmann Slot 모형을 이용한 지하방수로의 Geyser 발생 1차원 수치모의)

  • Choi, Seo Hye;Chegal, Sun Dong;Lee, SeungOh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.174-174
    • /
    • 2015
  • 국내의 국지성 집중호우와 같은 기후변화와 토지피복율 증가 등 복합적인 원인으로 인한 표면 유출수의 증가로 도시에서의 내수침수가 매년 빈번하게 발생하고 있다. 이러한 도심지 돌발홍수로 인한 피해에 대한 구조적인 대책으로 지하방수로가 효과적인 방안으로 대두되고 있으며, 현재 신월빗물저류배수시설이 설계단계에 있다. 그러나 미국, 일본 등의 국외의 기설치된 지하방수로에서 발생되는 Geyser 현상으로 인한 피해에 대한 연구는 국외에 비해 미비한 편이므로, 선행적으로 Geyser에 대한 물리기반의 동수역학적인 이해가 필요한 실정이다. Geyser는 홍수 시 급격한 유량의 유입으로 단파가 발생하여 지하방수로 내 공기의 압축이 발생하고 수직관을 통해 공기가 물과 함께 지상으로 분출되면서 발생된다. 따라서 공기와 물의 혼합 유동을 모의해야 하며 동시에 단파의 불연속성을 모의하기 위해서는 기존의 상용프로그램으로는 다소 어려움이 있다. 이에 본 연구에서는 지하방수로의 Geyser 현상의 발생 예측을 위해 1차원 Saint-Venant 방정식을 지배방정식으로 선정하였으며, 단파 발생을 수치적으로 안정적으로 모의하기 위해 Roe Approximate Riemann 수치기법을 사용하였다. 또한 공기의 압력항을 고려하기 위해서 수정된 형태의 Preissmann slot 모형을 적용하였다. Geyser 현상의 영향인자로서 지하방수로 수평관의 직경, 마찰계수, 바닥경사, 초기수위, 유입유량을 고려하였으며 상류에서 유입되는 유량에 의한 하류에서의 동수역학적 거동을 분석하였다. 5개의 영향인자의 변화에 따른 단파의 유입속도 및 공기부 압력의 변화를 관찰하여 Geyser 현상에 대한 동수역학적 검토를 수행하였다. 추후 본 연구결과를 적절히 활용한다면 지하방수로의 사용 안정성을 확보하고, 홍수발생 시 모니터링 인자도출에 도움이 될 것으로 예상된다.

  • PDF

A Study on the Exclusion Threshold Condition of the Riprap in the Bypass Pipe by 3D Numerical Simulation (3차원 수치모의를 통한 저층수 배사관 내 유입된 사석의 배제 한계조건에 대한 연구)

  • Park, Sun Bin;Jeong, Seok il;Lee, Seung Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.132-132
    • /
    • 2017
  • 큰 하상계수를 가지는 국내 중소하천의 특성상 농업용수 등의 수자원 이용을 위해 국내에는 약 10,000개 정도의 하천 횡단구조물이 설치되어 있다. 그러나 느려진 유속으로 인하여 횡단구조물 상류에 유사가 퇴적될 확률이 높아지며, 이러한 유사는 부착된 오염물에 의한 수질 및 하상오염, 좁아진 유수단면적에 의한 통수능 저하로 발생하는 홍수위 증가 등 많은 위험성을 내포하고 있다. 이에 대한 해결책 중의 하나로 저층수 배사관(bypass pipe)을 활용하여 쌓여진 유사를 하류로 흘려보내는 방법이 있다. 저층수 배사관은 횡단구조물 상류와 하류의 하상을 연결하는 관으로써 상류와 하류의 수두차에 의해 흐름 특성이 결정된다. 하지만 배사관 내 사석이 유입되어 배제되지 않는 경우 배사관의 효율이 현저하게 저하될 가능성이 있다. 본 연구에서는 FLOW-3D를 이용하여 배사관내 사석이 유입되었을 때, 어떠한 조건에서 배제되고 배제되지 않는지를 명확히 하고자 한다. 하상이 평탄한 수로$(13.0(L){\times}5.0(B){\times}1.0(H)m)$를 재현하였으며, 배출관의 직경은 10cm로 결정하였다. 사석의 종류는 4가지(3cm, 5cm, 7cm, 9cm)로써 이를 고려하여 격자크기를 0.5cm로 결정하였다. 이는 사석의 구형형상이 충분히 잘 재현될 수 있는 격자크기이다. 모의 수행은 하류의 수위를 변화시켜가며 수행하였다. 저층수 배사관 내 유동 특성이 상류와 하류의 수두차에 의해 결정되기 때문에, 모의의 효율성을 위해 상류의 수위는 일정한 값으로 진행하였다. 모의 결과 수위차가 클수록 배제가 잘되는 경향을 보였다. 입자의 크기와 상하류 수위차를 무차원화 한 변수를 결정하였다. 분석결과 이 변수가 일정 값을 넘어서는 경우 배제가 되며, 반대로 이 값을 넘어서지 못한 경우 배제가 되지 않음을 확인하였다. 향후 다양한 관의 형상에 대해서도 배사관 내 한계조건을 도출하여, 저층수 배사관의 설계 및 시공에 도움이 되고자 한다.

  • PDF