• Title/Summary/Keyword: 유동유속

Search Result 936, Processing Time 0.029 seconds

Effect of Pressure on Minimum Fluidization Velocity and Transition Velocity to Fast Fluidization of Oxygen Carrier for Chemical Looping Combustor (케미컬루핑 연소를 위한 산소전달입자의 최소유동화속도 및 고속유동층 전이유속에 미치는 압력의 영향)

  • KIM, JUNGHWAN;BAE, DAL-HEE;BAEK, JEOM-IN;PARK, YEONG-SEONG;RYU, HO-JUNG
    • Journal of Hydrogen and New Energy
    • /
    • v.28 no.1
    • /
    • pp.85-91
    • /
    • 2017
  • To develop a pressurized chemical looping combustor, effect of pressure on minimum fluidization velocity and transition velocity to fast fluidization was investigated in a two-interconnected pressurized fluidized bed system using oxygen carrier particle. The minimum fluidization velocity was measured by bed pressure drop measurement with variation of gas velocity. The measured minimum fluidization velocity decreased as the pressure increased. The transition velocity to fast fluidization was measured by emptying time method and decreased as the pressure increased. Gas velocity in the fuel reactor should be greater than the minimum fluidization velocity and gas velocity in the air reactor should be greater than the transition velocity to fast fluidization to ensure proper operation of two interconnected fluidized bed system.

Experimental Study on the Aerodynamic Characteristics of the Ducted Fan for a Small UAV (소형 무인기 추진용 덕티드 팬의 공력특성에 관한 실험적 연구)

  • Kim, Jae-Kyeong;Choi, Hyun-Min;Cha, Bong-Jun;Lee, Sang-Hyo;Cho, Jin-Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.251-256
    • /
    • 2008
  • The experimental analysis on a ducted fan for the propulsion system of a small UAV were performed. To investigate the aerodynamic characteristics of the ducted fan, flow fields at inlet and outlet were measured using a hot-wire anemometry. Thrusts were measured with the six-component balance with due regard to the cross wind. To reproduce the cross wind effect, the ducted fan was aligned to $90^{\circ}$ rotated direction against flow direction in the wind tunnel. In this paper, the variation of the flow fields and thrust according to the cross wind were analyzed.

  • PDF

Pollutant Dispersion Mechanism near Mokpo Harbor Due to the Discharges from Youngsan River Seadike (영산강 하구언 방류에 의한 목포항 주변해역의 오염확산양상)

  • An, Soon-Sub;Kang, Ju-Whan;Park, Seon-Jung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.2125-2129
    • /
    • 2007
  • 본 연구에서는 영산강 하구언 배수갑문의 개방으로 대량의 담수가 방류될 경우 목포항 인근해역의 해수유동 변화와 이에 수반되는 부유물질/염분 농도의 시공간적인 변화를 파악하기 위해 방류조건과 확산성분별로 12가지의 계산 시나리오를 구성하고 MIKE21의 해수유동(HD)모듈과 오염 확산(AD)모듈을 이용하여 하구언 방류의 영향을 살펴보았다. 해수유동 모의결과, 배수갑문과의 거리에 따라 방류조건별로 수위와 유속이 최대 144.5cm, 175.6cm/sec까지 상승하였다. 특히 청계만 수역에서는 방류시기에 낙조시 유속이 최대 68.8cm/sec까지 감소해 방류에 따른 수위상승으로 낙조시 해수유출이 지체되는 것으로 판단된다. 부유물질 확산모의 결과, 목포 기준검조소를 기준으로 목포항 내부수역은 원활한 해수순환이 이루어지지 않아 각종 오염원 유입시 외해로 쉽게 확산되거나 희석되지 못하고 계속 정체되는 것으로 나타나 항내 오염이 심각하게 우려되며, 특히 연속적인 담수 방류와 방류량의 크기가 내부수역의 부유물질 농도 감소에 큰 영향을 미치는 것으로 판단됨에 따라 방류량이 작고 연속 방류가 행해지지 않는 비우기시의 오염은 더욱 심해질 것으로 판단된다. 방류조건별 염분농도 역시 방류량이 크고, 연속적인 담수 방류가 행해질 경우 농도가도 크게 감소하며 확산면적도 증가하였다.

  • PDF

Heat Transfer on Secondary Injection Surface in Supersonic Flow-field with Various Injection Angle (초음속 유동장내 2차분사 분사각도 변화에 따른 열전달 특성 변화)

  • Song, Ji-Woon;Yi, Jong-Ju;Cho, Hyung-Hee;Bae, Ju-Chan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.321-325
    • /
    • 2008
  • In this paper, heat transfer changes due to the shock/boundary layer interaction were investigated on surfaces where secondary jet are injected. With an infra-red thermography, surface temperature was measured and the measured data was used to obtain the convective heat transfer. Heat transfer is enhanced with increment of momentum ratio. And normal injection case has a higher heat transfer value than that of 15 degrees inclined injection case. Secondary injection momentum ratio and injection angle affect the surface heat transfer distribution.

  • PDF

Pool Boiling Characteristics on the Microstructured surfaces with Both Rectangular Cavities and Channels (사각 공동 및 채널이 형성된 마이크로 구조 표면에서의 수조비등 특성연구)

  • Kim, Dong Eok;Park, Su Cheong;Yu, Dong In;Kim, Moo Hwan;Ahn, Ho Seon;Myung, Byung-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.6
    • /
    • pp.383-389
    • /
    • 2016
  • Based on a surface design with rectangular cavities and channels, we investigated the effects of gravity and capillary pressure on pool-boiling Critical Heat Flux (CHF). The microcavity structures could prevent liquid flow by the capillary pressure effect. In addition, the microchannel structures contributed to induce one-dimensional liquid flow on the boiling surface. The relationship between the CHF and capillary flow was clearly established. The driving potentials for the liquid supply into a boiling surface can be generated by the gravitational head and capillary pressure. Through an analysis of pool boiling and visualization data, we reveal that the liquid supplement to maintain the nucleate boiling condition on a boiling surface is closely related to the gravitational pressure head and capillary pressure effect.

Evaluation of Groundwater Flow by Gravel-Filling and Temporary Drainage in Groundwater-saturated Limestone Mine Cavities (지하수 포화 석회석 채굴공동에서의 골재 충전 및 임시배수시 발생하는 지하수 유동 평가)

  • Choi, Woo-Seok;Kang, Byung-Chun;Kim, Eun-Sup;Shin, Dong-Choon
    • Tunnel and Underground Space
    • /
    • v.27 no.4
    • /
    • pp.205-216
    • /
    • 2017
  • Fluctuations in groundwater level are the major cause of ground subsidence in the abandoned limestone mine. In this study, evaluation of groundwater flow under three different cases of natural condition, aggregate-filling, temporary drainage in groundwater-saturated limestone mine cavities was executed by 3-dimensional analysis. In the case of aggregate-filling, although the water level both in the upper ground of mine cavities and an agricultural watershed was elevated, it was lower than the water level fluctuation of an agricultural water use and rainfall and the flow rate was similar to the flow rate of natural condition. In the case of temporary drainage, as the water level in the upper ground of mine cavities and an agricultural watershed decrease rapidly and the flow rate has increased by 25times, so the risk of ground subsidence increased.

Analysis of Flow Field Characteristics Inside a Shroud for Rotor Positions (로터 위치에 따른 쉬라우드 내부 유동장 특성 분석)

  • Bak, Da In;Han, Seok Jong;Lee, Uk Jae;Lee, Sang Ho;Choi, Hyuk Jin;Im, Jong Seok
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.1
    • /
    • pp.48-54
    • /
    • 2020
  • Numerical analysis was carried out to analyze the flow fields and mechanical output of a rotor for various positions and inlet flow rates in a shroud, and it was compared with experimental data. Rotor and seawater current largely affects the flow field characteristics in the shroud system. Especially the mechanical output of the rotor increased with axial position near the center of the cylinder, and it gradually decreased close to the entrance and exit. Also, the rotor output increased with the inlet velocity. Axial and angular momentum of flow along the cylinder region rapidly increased and reached a peak, and then decreased as it passed through the rotor, while there was no significant change in the cylinder region. It is expected that these results can be used as applicable design data for the development of the tidal power generation system.

A Study on the Drying and Carbonization of Sewage Sludge in Fluidized Bed Reactor (유동층 반응기에서 하수슬러지의 건조 및 탄화 특성에 관한 연구)

  • Choung, Young-Hean;Cho, Ki-Chul;Kang, Dong-Hyo;Kim, Yi-Kwang;Park, Chang-Woong;Oh, Kwang-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.7
    • /
    • pp.746-751
    • /
    • 2006
  • In this study, drying and carbonization experiment was conducted in a fluidized bed reactor according to the variations in gas velocity, particle size, and reactor temperature. As a result, the weight loss rates of sludge by drying in the fixed bed and fluidized bed type dryer showed that drying in the fluidized bed was about 6 times faster than drying in the fixed bed, and the weight loss rates of sludge by carbonization in the fixed bed and fluidized bed type reactor showed that carbonization in the fluidized bed was about 4 times faster than drying in the fixed bed. This implies that carbonization in the fluidized bed was completed within 10 minutes. Although the amount of char decreased with the increase of carboniration temperature, the amount of char became similar at upper 873K. Also, the amount of char decreased with increasing gas velocity. Consequently, it could be efficient that slow fluidization should be maintained within the range of fluidization in case of fluidized carbonization of sewage sludge at 873K.

범용 전산유체 코드를 이용한 봉 다발에서의 난류 유동 수치해석

  • 인왕기;오동석;전태현;정연호
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.567-572
    • /
    • 1997
  • 범용 전산유체해석(Computational Fluid Dynamics) 코드인 CFX-F3D를 이용하여 봉 다발에서의 난류 유동 수치해석을 수행하였다 3$\times$3 봉으로 구성된 부수로 사이의 난류 횡류(Crossflow) 혼합유동과 평행한 4개의 봉으로 이루어진 벽 수로에서의 난류 유동구조를 수치적으로 분석하여 각각의 실험결과와 비교하였다. 부수로 횡류 혼합유동의 경우 예측된 주 유동방향 평균 속도분포는 실험결과와 잘 일치하였으나 벽면과 인접한 부수로에서의 난류강도 분포는 다소 큰 차이가 나타났다. 백수로의 경우 수로 중심선 근처의 주 유동방향의 속도변화는 크게 예측되었고 벽 전단응력은 유로가 협소해지는 영역에서 낮게 예측되었으나 전반적으로 실험결과와 유사한 유동특성을 나타냈다. 이 연구는 봉 다발에서의 난류 유동구조에 대한 이해를 증진시킴과 더불어 CFX-F3D 코드를 평가함으로써 향후 지지격자와 임계열유속 증진장치가 부착된 복잡한 형상의 핵연료 다발에서의 유동장 수치해석의 기반을 마련하였다.

  • PDF

Discharge Computation in Natural Rivers Using Chiu's Velocity Distribution and Estimation of Maximum Velocity (자연하천에서 Chiu의 유속분포와 최대유속 추정을 이용한 유량산정)

  • Kim, Chang-Wan;Lee, Min-Ho;Yoo, Dong-Hoon;Jung, Sung-Won
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.6
    • /
    • pp.575-585
    • /
    • 2008
  • It is essential to obtain accurate and highly reliable streamflow data for water resources planning, evaluation and management as well as design of hydraulic structures. A new discharge computation method proposed in this research uses Chiu's velocity distribution and estimation of maximum velocity. This method shows acceptable channel discharges comparing these by the exiting velocity-area method. When velocity-area method is used, it is required to observe velocities at every specified point and vertical line using a velocity meter like Price-AA. If the method proposed in this research, is used, however it is not necessary to observe all point velocities needed in the velocity-area method. But this method can not be applied for the cases of very complex and strongly asymmetric channel cross-sections because Chiu's velocity distribution using entropy concept may be quite biased from that of natural rivers.