• Title/Summary/Keyword: 유동상 반응기

Search Result 60, Processing Time 0.023 seconds

Nitrogen Removal in Fluidized Bed and Hybrid Reactor using Porous Media (다공성 담체를 이용한 유동상 및 하이브리드 반응기에서의 질소제거)

  • Jun, Byong-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.5
    • /
    • pp.542-548
    • /
    • 2005
  • A fluidized bed reactor containing porous media has been known to be effective for nitrogen and organic matters removal in wastewater. The porous media which attached microbes plays important roles in simultaneous nitrification/denitrification (SND) due to coexistence of oxic, anaerobic and anoxic zone. For SND reaction, oxygen and organic substrates should be effectively diffused from wastewater into the intra-carrier zone. However, the overgrowth heterotrophic microbes at the surface of porous media may restrict from substrates diffusion. From these viewpoints, the existence and effect of heterotrophic bacteria at surface of porous media might be the key point for nitrogen removal. A porous media-membrane hybrid process was found to have improved nitrogen removal efficiency, due to stimulated denitrification as well as nitrification. Microelectrode studies revealed that although intra-media denitrification rate in a conventional fluidized bed was limited by organic carbon, this limitation was reduced in the hybrid process, resulting in the increased denitrification rate from 0.5 to $4.2\; mgNO_3-N/L/hr$.

The Removal of Toluene by a Granular Activated Carbon Bioreactor using Yeast (Yeast와 입상활성탄을 이용한 미생물반응기의 휘발성유기화합물 분해 특성)

  • NamGung, Hyeong-Kyu;Shin, Seung-Kyu;Ahmed, Zubair;Song, Ji-Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.12
    • /
    • pp.1218-1224
    • /
    • 2008
  • A liquid culture of yeast "Candida tropicalis" was used in a fluidized bioreactor to achieve high removal efficiencies of volatile organic compounds (VOCs). In this study, granular activated carbon (GAC) was used as a fluidized material to improve adsorptive capacity as well as mass transfer of gaseous toluene, the model VOC. The GAC fluidized bioreactor demonstrated toluene removal efficiencies ranging from 50 to 80%, when inlet toluene loading varied in a range between 13.1 and 37.4 g/m$^3$-hr. The maximum elimination capacity determined in the GAC fluidized bioreactor was 172 g/m$^3$-hr at a toluene loading of 291 g/m$^3$-hr. Transient loading experiments revealed that the removal efficiency was remained unchanged during an increased loading period, and toluene introduced to the bioreactor was first absorbed to GAC and then slowly desorbed and became available to the yeast culture. Hence the fluidized GAC helped to achieve an improved mass transfer between the gas and liquid phases, resulting in high toluene removal capacity. Consequently, the GAC fluidized bioreactor using C. tropicalis can be successfully applied for the removal of VOCs, and is a feasible alternative over conventional processes such as packed-bed biofilters.

Heat Transfer Characteristics of Concurrent Downflow Circulating Fluidized Reactor (Downflow 순환유동층에서의 열전달 특성)

  • 김용전;방진환;김상돈
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1998.05a
    • /
    • pp.27-30
    • /
    • 1998
  • 지난 수십 년간 순환유동층과 riser 반응기에 관한 연구는 상당한 진전을 이뤄왔다. 비록, 순환유동층(riser)반응기가 전형적인 유동층에 비해 여러 가지 장점 -높은 기-고의 접촉효율, 높은 기체와 고체의 처리량, 기상과 고상의 낮은 축방향 분산, 높은 turndown ratio, 점결성 입자의 처리-을 가지고 있으나, 불균일한 기-고의 흐름에 의한 고체의 역혼합(back-mixing)으로, 기체와 고체의 반경방향의 분리를 일으켜 두상간의 접촉을 감소시켜 생성물의 균일성과 선택도를 감소시킨다. 이러한 riser 반응기의 단점을 보완하기 위해 최근에는 기-고의 하향흐름을 갖는 downer(downflow) 반응기에 대한 관심이 증가하고 있다. (중략)

  • PDF

Study on Feasibility of Fluidized Bed Membrane Reactor with Granular Activated Carbon Particles as Fluidized Media to Treat Metal-plating Wastewater (도금폐수처리를 위한 입상활성탄 유동 메디아 적용 유동상 멤브레인 여과기술의 적용가능성 평가에 관한 연구)

  • Chang, Soomin;Kwon, Deaeun;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.28 no.4
    • /
    • pp.252-259
    • /
    • 2018
  • An acidic, real metal-plating wastewater was treated by a fluidized bed membrane reactor introduced with granular activated carbon (GAC) as fluidized media. With GAC fluidization, there was no increase in suction pressure with time at each flux set-point applied. At neutral solution pH, much less fouling rate was observed than acidic pH under GAC fluidization. Higher solution pH resulted in the increase in particle size in metal-finishing wastewater, thus producing a less dense cake structure on membrane. More than 95% of chemical oxygen demand was observed from the fluidized bed membrane reactor under GAC fluidization. Total suspended solid concentration in membrane permeate was near zero. At the raw wastewater pH, no removal of copper and chromium by the fluidized bed membrane reactor was observed. As the pH was increased to 7.0, removal efficiency of copper and chromium was increased considerably to 99 and 94%, respectively. Regardless of solution pH tested, more than 95% of cyanide was removed possibly due to the strong adsorption of organic-cyanide complex on GAC in fluidized bed membrane reactor.

Numerical Sudy on Bubbling Fluidized Bed Reactor for Fast Pyrolysis of Waste Lignocelluosic Biomass (폐목질계 바이오매스의 급속열분해 기포유동층 반응기에 대한 수치해석적 연구)

  • Lee, Ji Eun;Choi, Hang Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.10
    • /
    • pp.710-716
    • /
    • 2013
  • New and renewable energy sources have drawn attention because of climate change. Many studies have been carried out in waste-to-energy field. Fast pyrolysis of waste lignocelluosic biomass is one of the waste-to-energy technologies. Bubbling fluidized bed (BFB) reactor is widely used for fast pyrolysis of the biomass. In BFB pyrolyzer, bubble behavior influences on the chemical reaction. Accordingly, in the present study, hydrodynamic characteristics and fast pyrolysis reaction of waste lignocellulosic biomass occurring in a BFB pyrolyzer are scrutinized. The computational fluid dynamics (CFD) simulation of the fast pyrolysis reactor is carried out by using Eulerian-Granular approach. And two-stage semi-global kinetics is applied for modeling the fast pyrolysis reaction of waste lignocellulosic biomass. To summarize, generation and ascendant motion of bubbles in the bed affect particle behavior. Thus biomass particles are well mixed with hot sand and consequent rapid heat transfer occurs from sand to biomass particles. As a result, primary reaction is observed throughout the bed. And reaction rate of tar formation is the highest. Consequently, tar accounts for 66wt.% of the product gas. However, secondary reaction occurs mostly in the freeboard. Therefore, it is considered that bubble behavior and particle motions hardly influences on the secondary reaction.

A Study on Gas Mixing in a Circulating Fluidized Bed (순환유동층에서 기체의 혼합특성에 관한 연구)

  • 남궁원;김상돈
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.11a
    • /
    • pp.23-26
    • /
    • 1995
  • 내경 0.1 m, 높이 5.3 m 의 순환유동층 반응기를 사용하여 기체의 역혼합특성을 조사하였다. 기체의 역혼합은 동일한 기상유속일때 고체순환속도가 증가할수록 증가하였다. 희박상영역에서 일정한 고체체류량에서는 기상유속이 증가할수록 벽면에서의 하강흐름도 증가되어 기체의 역혼합은 증가되었다. Tracer 주입위치가 반응기 벽면에서 중심으로 이동할수록 빠른 기체와 고체의 흐름으로 인하여 기체의 역혼합은 상당히 감소하였다. 그리고, 희박상영역에서 core-annulus 구조를 기초로 하여 기체역혼합과 core 와 annulus 간의 물질전달계수를 예측할 수 있는 모델식을 제안하였다.

  • PDF

ACPF 전해환원 실험 및 결과

  • Park, Byeong-Heung;Hong, Sun-Seok;Heo, Jin-Mok;Lee, Han-Su
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2009.06a
    • /
    • pp.291-291
    • /
    • 2009
  • 한국원자력연구원의 파이로 실험 시설인 ACPF (ACP Facility)에는 공학규모 전해환원 반응기가 설치되어 공정 대용량화를 위한 연구가 수행되고 있다 본 연구에서는 전해환원 공정의 Scale-up을 위해 기존 반응기를 개선하여 전해환원 실험을 수행한 결과를 담고 있다. 장치의 대형화 빛 원격운전성 향상을 위해 기존의 전해환원 반응기의 상부 플랜지는 보다 간단하게 정리되었으며 염 이송에 의한 고온 조건 노출 시간을 줄임과 동시에 염 재사용을 목적으로 상부 플랜지는 이중으로 설계되었다. 따라서, 반응 종료후 전극이 설치된 상부 플랜지를 들어 올림으로서 반응기를 불활성 분위기로 유지하는 동시에 전해환원 금속전환체를 회수 할 수 있도록 반응기가 제작되었다. 또한, 새로운 반응기는 용융염 내의 강제 유동을 위해 아르곤 버블링이 가능하도록 설계 제작되었다. 새로 제작 설치된 전해환원 반응기를 사용하여 산화물 분말을 혼합하여 준비한 모의 사용후핵연료를 사용하여 전해환원 실험을 수행하였다. 그 결과, 산화물이 충진된 음극의 전영역에서 고루 96% 이상의 높은 금속전환율을 얻었으며 시간에 따라 선택된 FP들의 용융염 내 거동을 측정하였다. 실리더 형태의 음극에서 Cs, Sr 등의 원소들이 용융염으로 시간에 따라 용출되는 것을 확인하였으며 동시에 반응기 재질인 Fe 등도 일부 용융염에서 검출되었다. 아르곤 버블링에 의한 강제 유동은 전압 및 전류 거동에는 큰 영향을 미치지 못하였으나 염의 휘발량을 증가시켜 영조성올 변화시키는 것으로 측정되었다. ACPF의 전해환원 실험결과를 바탕으로 반응기를 상부 기체상과 하부 액체상으로 나누어 전산모사를 수행하였다 상부 기체상은 유입되는 아르곤 기체와 발생되는 산소기체의 흐름을 모사하는 결과를 얻었으며 온도 및 산소의 분압을 계산하였다. 하부 액체상에서는 전기장을 모사하여 전류 밀도 등을 3차원으로 모사하였다.

  • PDF

The Removal of Organics, Nitrogen and Phosphorus in Loop Reactor Using Fluidized Media (유동상 담체를 이용한 Loop Reactor에서 유기물 및 질소, 인 제거)

  • Seon, Yong-Ho
    • KSBB Journal
    • /
    • v.24 no.4
    • /
    • pp.353-360
    • /
    • 2009
  • This study was accomplished using Anaerobic/Anoxic/Oxic upflow packed-bed column reactors with fixed media and Loop Reactor with fluidized media instead of Oxic reactor. The objectives of this study was to investigate the characteristics of organics, nitrogen and phosphorus removal from sewage with the HRT. The average removal efficiencies of $BOD_5$ and SS increase as increasing the hydraulic retention time (HRT) until 16 h of the HRT, and they were constant over 16 h of the HRT. The removal efficiency of $BOD_5$ in case of packed-bed reactor and Loop Reactor was about 86.6% and 90.9% respectively at 16 h of the HRT. The removal efficiency of SS in packed-bed reactor and Loop Reactor was about 78.0% and 88.2% respectively at 16 h of the HRT. The average removal efficiencies of $COD_{Cr}$ and $COD_{Mn}$ showed similar trends as those of $BOD_5$ and SS. At the HRT of 16 h, the removal efficiency of $COD_{Cr}$ in case of packed-bed reactor and Loop Reactor was 63.5%, 75.2% and that of $COD_{Mn}$ was 60.7%, 73.6% respectively. The average removal efficiencies of T-N and T-P increase as increasing the HRT. The removal efficiencies of T-N and T-P in Loop Reactor were 33.6% and 54.5% respectively at 16 h of the HRT and T-N and T-P were better removed in Loop Reactor. From this result, it was found that the performance of Loop Reactor was much higher than the performance of packed-bed reactor and the optimum HRT was 16 h.

Design of SCR Reactor for NOx Reduction (질소산화물 제거를 위한 SCR 반응기 설계)

  • 이인영;김동화;이정빈;김우영
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.425-426
    • /
    • 2001
  • 선택적촉매환원(Selective Catalytic Reduciton: SCR)공정은 배기가스 중 질소산화물을 암모니아와 촉매상에서 반응시켜 무해한 질소와 물로 전환하는 기술이다(Bosch, 1988). SCR 공정에서 우수한 촉매가 확보되었을 경우, 설비의 성능은 촉매층로 유입되는 유동의 조건에 따라 좌우되므로 최적의 유동조건을 갖도록 반응기의 구조와 가이드 베인등 유로변경장치를 설계하는 것은 매우 중요하다(Cho, 1994). (중략)

  • PDF

Gas and Liquid Flow Characteristics in an Internal Circulation Airlift Reactor using a Single Nozzle -Effects of Flow Zone Sizes- (단일노즐을 사용한 내부순환 공기리프트 반응기에서 기체 및 액체의 유동특성 - 유동지역의 크기영향 -)

  • Jang, Sea-Il;Kim, Jong-Chul;Jang, Young-Joon;Son, Min-Il;Kim, Tae-Ok
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.901-906
    • /
    • 1998
  • Gas and liquid flow characteristics were investigated in an internal circulation airlift reactor using a single nozzle for a gas distributor. In three reactors with different diameters of the downcomer and heights of the riser, the gas holdup in the individual flow zone and the impulseresponse curve of tracer for an air-water system were measured for various gas velocities and reactor heights. Experimental results showed that the flow behavior of bubbles in the riser was the slug flow due to strong coalescences of bubbles and that the bubble flow pattern in the downcomer was the transition bubble flow for the smaller diameter of the downcomer, however, it was the homogeneous bubble flow for the larger one. And mean gas holdups in the individual flow zone and the reactor were greatly increased with decreasing the diameter of the downcomer for the equal ratio of height of the top section to that of the riser. Also, the mixing time was much effected by the height of the top section of reactor and for the equal ratio of height of top section to that of the riser, it was increased with increasing the diameter of the downcomer and the height of the riser. Flow characteristics of liquid were mainly varied with the bubble flow pattern in the downcomer and the size of the top section of reactor. And circulation velocities of liquid in the riser were increased with increasing gas velocities and the size of the top section of reactor, and for the equal ratio of height of top section to that of the riser, they were increased with increasing the diameter of the downcomer and the height of the riser.

  • PDF