• Title/Summary/Keyword: 유도전동기

Search Result 2,069, Processing Time 0.03 seconds

Analysis of the Dynamic charactristics of Linear Induction Motor considering the variation of loads (부하변동을 고려한 선형유도전동기의 동특성 분석)

  • Chun, Sam-Suk;Park, Chan-Won;Lim, Byung-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1162-1164
    • /
    • 2005
  • A Linear Induction Motor that generates the direct thrust directly, is widely used for the operation system of electrified railroad, elevation system, conveyer system, and so on. There are two analysis methode of linear induction motor characteristics. One is the electrical magnetic analyzing, the other is analyzing equivalent circuit. The electrical magnetic analyzing methode has available advantages to consider the physical condition. The equivalent circuit analyzing methode has the elementary methode in the system of vector control and over shoot situation. In this paper, It is used the dynamic characteristic analyzing methode that can calculate efficiently the end effect by using equivalent circuit methode in the operating linear induction motor system modeling and doing simulation of output characteristics of vector controller.

  • PDF

A Study on Inductance calculation of Line start Synchronous Reluctance Motor using Equivalent Magnetic Circuit Method (등가 자기 회로를 이용한 단상 유도형 동기 릴럭턴스 전동기의 인덕턴스 산정에 관한 연구)

  • Ha, Seung-Hyoung;Lee, Ji-Young;Hong, Jung-Pyo;Nam, Hyuk;Kang, Gyu-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1117-1119
    • /
    • 2005
  • The inductance is an important parameter in order to analyze steady state of LSRM(Line-start Synchronous Reluctance Motor). If FEM(Finite Element Method) is used to compute the parameter according to the change of flux barriers and conductor bars, less analysis time is required. Therefore, this paper adopts equivalent magnetic circuit method to simply calculates inductance, and the result is verified by comparing with the results by FEM.

  • PDF

The Selection of the Condenser Positions for the Improvement Power Factor of the High Voltage Induction Motors (고압유도전동기의 역률개선을 위한 콘덴서 위치 선정 방안)

  • Lee, Eun-Chun;Jeon, Il-Bang;Kim, Chang-Bum;Choe, Yeong-Gyu;Shin, Kang-Uk;Hong, Sung-Taek;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1068-1070
    • /
    • 2005
  • This study sorted high voltage motors by the voltage and the capacity and analyzed the property of motor-start. So we found out some problems of the starting circuit from several sites, and made the answers of the problems. If these results of our study are utilized in new WTPs, the safety of the starting circuit will be improved and the life of electric power system will be longer. We recommend this study as a reference when our company founds the standard of electric facility design.

  • PDF

A study on characteristic analysis using overhang structure in Line Start Permanent Magnet Motor (오버행 구조를 갖는 단상 유도동기 전동기의 특성해석)

  • Shin, Kwang-Chul;Kwon, Byung-Il;Rhyu, Se-Hyun;Kim, Byung-Teak
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1306-1308
    • /
    • 2005
  • The characteristic of line start permanent magnet(LSPM) motor with overhang structure is analyzed using 3dimensional finite element method(3D FEM). We propose the appropriate overhang length by considering the magnetic flux distribution according to changing overhang length and manufacturing process. 3D FEM analysis is inevitable because the increase of the total flux cannot be appropriately considered in 2D FEM. In equal model specification total flux is recalculated at 3D FEM, because of considering lamination length. This paper compares the characteristic of Back-emf with and without overhang by permanent magnet that has identical volume.

  • PDF

The Starting Characteristics of Single Phase Induction Motor by Control of Phase and Voltage (위상각과 전압제어에 의한 단상유도전동기의 기동특성)

  • Sung, K.M.;Park, S.K.;Choi, Y.O.;Cho, G.B.;Oh, K.G.;Baek, H.L.;Park, H.A.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.350-352
    • /
    • 1995
  • The starting characteristics of single phase induction motor(SPIM) is described by control of phase and voltage. Auxiliary winding voltage is controlled by DC amplifier and phase is integrator. These processes enable comparison of torque with slip in each voltage and phase angle variations. Simulation and experimentation results of the motor's torque-slip characteristics using the controlled auxiliary winding voltage and phase angle arc shown and discussed. As a results, starting time is fast and main winding current is small when auxiliary winding voltage is low than rating voltage and starting characteristics is good in phase angle $90^{\circ}$.

  • PDF

Vector Control of Induction Motors with Identification of Rotor Time Constant (회전자 시정수 변동을 보상한 유도 전동기 벡터제어)

  • Kim, Nam-Joon;Lee, Dong-Myung;Moon, Hee-Sung;Hyun, Dong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.353-356
    • /
    • 1995
  • This paper proposes a simple identification method of the rotor time constant to solve the degradation of motor performance due to the difference between the rotor time constant of a controller and actual one in slip frequency type vector control scheme. The proposed method is based on rotor induced voltage equations and it is confirmed that immunity of the stator resistance thermal variation. The simulation results show that the proposed method suitably identifies the rotor time constant in steady state as well as in transient state.

  • PDF

An Analysis on the Equivalent Circuit and the Accelerating Characteristics of Single Sided Linear Induction Motor (편측식(片側式) 선형유도전동기(線型誘導電動機)의 등가회로 구성과 가속특성(加速特性) 해석)

  • Jang, S.M.;Park, C.I.;Kim, G.T.;Kim, Y.R.;Kim, B.S.;Jung, Y.U.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.180-182
    • /
    • 1995
  • The equivalent circuit of SLIM is composed of the circuit parameters. They can be obtained from the electromagnetic theory. The accelerating characteristics of SLIM are the best efficiency when synchronous speed changed continuously. The paper outlines a method of acceleration for an accelerated field system in which it is desired to reduce the overall length to a minimum, assuming a limit on the amount of heat which can be generated in the secondary member. The paper then shows that a primary unit designed to give several discrete field speeds only, as opposed to one with continuous speed variation, is not significantly inferior in performance to the latter but is much easier to manufacture.

  • PDF

Calculation of Resistance of Cage Rotor End Ring using 3-D Finite Element Method (3차원 유한요소법을 이용한 농형유도전동기 단락환의 저항계산)

  • Bak, Min-Woo;Lee, Bok-Yong;Jung, Hae-Duk;Lee, Ki-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.92-94
    • /
    • 1995
  • This paper is to describe a method for calculating resistance of cage rotor end-ring, based on 3-D finite element method using magnetic vector potential $\vec{A}$ and electric scalar potential ${\phi}$. The induced current of a cage rotor flows through the bars of a cage rotor. The current completes their closed paths by passing around the end-ring. The end-ring may contribute a significant influence to the performance of machine. The resistance under consideration of skin effect is calculate by using Joule's loss equation.

  • PDF

The Analysis on Vector Control Characteristics of LIM Using Finite Element Method (FEM을 이용한 선형유도 전동기의 벡터제어 특성 해석)

  • Im, D.H.;Kwon, B.I.;Lee, J.H.;Woo, K.I.;Kim, C.E.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.3-5
    • /
    • 1995
  • For a linear induction motor(LIM), the constants of each phase are different due to the structure. In this paper, a vector control analysis method of a LIM taking into consideration its asymmetrical constants are proposed. And, in order to prove the propriety of proposed vector control method and to analyze the dynamic characteristics of LIM's vector control, FEM taking into account of movement and using stator tapped winding is used in the analysis region. So, It is confirmed that the proposed asymetrical constants vector control theory and simulation method of mixing with FEM is appropriate to dynamic characteristics analysis of LIM.

  • PDF

High-Reliable Classification of Multiple Induction Motor Faults Using Vibration Signatures based on an EM Algorithm (EM 알고리즘 기반 강인한 진동 특징을 이용한 고 신뢰성 유도 전동기 다중 결함 분류)

  • Jang, Won-Chul;Kang, Myeongsu;Choi, Byeong-Keun;Kim, Jong-Myon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.346-353
    • /
    • 2013
  • Industrial processes need to be monitored in real-time based on the input-output data observed during their operation. Abnormalities in an induction motor should be detected early in order to avoid costly breakdowns. To early identify induction motor faults, this paper effectively estimates spectral envelopes of each induction motor fault by utilizing a linear prediction coding (LPC) analysis technique and an expectation maximization (EM) algorithm. Moreover, this paper classifies induction motor faults into their corresponding categories by calculating Mahalanobis distance using the estimated spectral envelopes and finding the minimum distance. Experimental results shows that the proposed approach yields higher classification accuracies than the state-of-the-art approach for both noiseless and noisy environments for identifying the induction motor faults.

  • PDF