• Title/Summary/Keyword: 유도공기

Search Result 350, Processing Time 0.032 seconds

Comparison of Doses According to Change of Bladder Volume in Treatment of Prostate Cancer (전립선암 치료 시 방광의 용적 변화에 따른 선량의 비교 평가)

  • Kwon, Kyung-Tae;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.415-421
    • /
    • 2017
  • In the case of radiation therapy for prostate cancer, a balloon infused with a certain amount of air through the anus is used to reduce rectal dose. Because of the reason, radiation therapy for prostate cancer has acquired CBCT for daily image induction. In order to maintain the anatomical structure most similar to the first CT taken before treatment, it is pretreated, but it can not be said to be perfectly consistent. In two actual treatment regimens, the volume of the bladder was measured as 45.82 cc and 63.43 cc, and the equivalent diameter was 4.4 cm and 4.9 cm. As a result of this study, the mean volume of the bladder was estimated to be 56.2 cc, 105.6 cc by 20 CBCT. The mean dose of CBCT was 1.74% and the mean Bladder mean dose was 96.67%. In case B, PTV mean dose was 4.31%, Bladder mean Dose was estimated to be 97.35%. The changes in the volume of the bladder resulted in changes in the dose of PTV and bladder. The correlation coefficient of bladder dose according to the change of bladder volume showed linearity of mean dose $R^2=-0.94$. The correlation coefficient of the PTV dose according to the volume change of the bladder showed linearity of mean dose $R^2=0.04$. It was found that the dose change of PTV was larger than that of bladder according to the change of bladder volume.

Transmittance Characteristics of Fishing Lamp in the Anchovy Scoop Fishery (멸치초망어업용 집어등 광력의 수중 투과특성)

  • 박성욱;배봉성;안희춘;서두옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.117-123
    • /
    • 2001
  • Anchovy scoop nets, a kind of lift net have been used in the coastal area of Cheju and South sea of Korea. An incandescent lamp(AC 100V, 1kW) is being used as a fishing lamp for gathering anchovy. Fishing lamp was installed at 1m ahead of the prow and 1.5m higher than the water surface. The fishing lamp let fish school rise to the water surface and attract to bag net. Accordingly, a successful anchovy catching depends on controling of fishing lamp. On the study, the distribution of spectral irradiance illumination of incandescent lamp(1kw) and the irradiance efficiency of reflection plate were analyzed and discussed to investigate the ability of fishing lamp which can attract anchovy school effectively. The results obtained are summarized as follows : 1. Around 180% of irradiance efficiency of incandescent lamp was increased by using the reflection plate. The light of lamp was radiated into water with circular shape. 2. The irradiance illumination of incandescent lamp in air was a maximum in wave length of 994nm but it was 690nm at 0.5m and 1.0m of water depth. 3. The relationship between water depth(x) and water illumination(y) of vertical light is represented as follows : y=146.03e supper(-0.37x) 4. The light of incandescent lamp(1kW) pass through much better into vertical direction than horizontal but it was estimated that the light was not able to reach depth of 20m.

  • PDF

A Study on the Development of High Permeability and Low Coercivity Ni-Zn Ferrite (고투자율, 저보자력을 갖는 Ni-Zn Ferrite의 개발에 관한 연구)

  • 고재귀
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.1
    • /
    • pp.13-18
    • /
    • 1997
  • The effects of the various raw material composition and sintered temperature on the physical properties of Ni-Zn ferrite have been investigated. They turned out to be spinel structure by X-ray diffraction and the size of grain from microscope was from 6 ${\mu}{\textrm}{m}$ to 16 ${\mu}{\textrm}{m}$. As the sintering temperature was increased from 1030 $^{\circ}C$ to 1070 $^{\circ}C$, the initial permeability and magnetic induction has increased and the both of Q factor and coercive force has decreased. The coercive force and curie temperature were almost the same at each specimen. Their values were about 0.20 Oe and 220 $^{\circ}C$. The frequency of specimen will used in the range from 400 kHz to 20 MHz. The basic composition of $Ni_{0.14}Zn_{0.64}Cu_{0.22}Fe_2O_4$ (specimen B) sintered at 1050 $^{\circ}C$ shows the best results at magnetic induction($B_r & B_m$).

  • PDF

Characterization of Antioxident Enzymes in the Lung of Rat Exposed to Cigarette Smoke (흡연한 흰쥐 폐조직 항산화효소들의 특성)

  • 이영구;손형옥;임흥빈;이동욱;박준영
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.15 no.1
    • /
    • pp.3-14
    • /
    • 1993
  • Oxidants in environment or cigarette smoke are known to be implicated in the oxidative damages of pulmonary system. Such cellular damages are prevented by the presence of adequate levels of antioxidants in the tissue. In the present study, we investigated the influences of smoking duration and concentration of smoke on lung antioxidant defense in rats. Subchronic exposure of rats to smoke generated from 6 cigarettes per day for 90 days caused the activities of catalase and superoxide dismutase (SOD) to increase. However, glutathione peroxidase (GP-Xase) was not significantly changed. Total sulfhydryl compounds (Total-SH) in the lung homogenates from the rats inhaled with cigarette smoke for 15 days was decreased by 44% , thereafter it was returned to the level of normal rats. On the contrary, when rats were daily exposed to a different concentration of smoke generated from 1 to 20 cigarettes per day for 15 days, the activity of catalase was increased gradually with dose, but total SOD activity was increased only in the rats of low dose groups less than 5 cigarettes. Three types of SOD (one Cu, Zn-SOD with pI 4.9, and two Zn-SOD with pI 4.7 and 7.9)were detected in the lung homogenates and Zn-SOD with pI 4.7 was the major and cigarette-smoke inducible form. These results indicate that the protection of lung against oxidants from cigarette smoke seems to be accomplished by the induction of catalase and SOD, especially a cyanide resistant Zn-SOD with pI 4.f, following the consumption of antioxidants such as GSH in the beginning of inhalation period.

  • PDF

The Effects of Panax Ginseng Extract on Antioxidative Enzyme Activity in Ovariectomized Rats (인삼 추출물이 난소를 절제한 백서의 항산화효소 활성에 미치는 영향)

  • 하배진;황일영
    • Journal of Life Science
    • /
    • v.12 no.3
    • /
    • pp.349-356
    • /
    • 2002
  • In order to observe the bioactivity of ovariectomized rats, nonovariertoized (sham) group, ovariectomized (Ovx) group, ovariectomized ginseng total saponin (GTS)-treated (Ovx+ GTS) group and ovariectomized ginseng water extract (GW)-treated (Ovx+CW) group were made. We measured AST (L-aspartate aminotransferase) and ALT (L-alanin aminotransferase) in sera, and MDA (malondialdehyde:lipid peroxidation), SOD (superoxide dismutase), catalase, total-glutathione (GSH + GSSG) and GPx (glutathione peroxidase) in liver tissue total homogenates of rat. AST activity of serum in Ovx group was 2.11 times increased, but ALT activity was not changed compared to Sham group. In AST activity, they tend to decrease significantly in each substance such as GTS and GW administered group. Lipidperoxides of each fraction in Ovx group were highly increased compared to Sham group. Extracts of ginseng-treated group markedly inhibited lipid peroxidation by 62% ∼72%. And as the result of the measurements of SOD, catalase, total-glutathione and GPx which are antioxidant enzyme, antioxidant enzymes in Ovx group much lower than in Sham group. But they were significantly increased in each substance such as GTS and GW, administered group. Based on the results, it is supposed that more produced free radicals decreased antioxidant enzyme. And it is also thought that extracts of ginseng can inhibit aging by reducing antioxidant enzyme.

Analysis of Heat Emission from Hot Water Pipe for Greenhouse Heating System Design (온실 난방시스템 설계를 위한 온수난방배관의 방열량 분석)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.204-211
    • /
    • 2019
  • The purpose of this study is to provide basic data for setting environmental design standards for domestic greenhouses. We conducted experiments on thermal environment measurement at two commercial greenhouses where hot water heating system is adopted. We analyzed heat transfer characteristics of hot water heating pipes and heat emission per unit length of heating pipes was presented. The average air temperature in two greenhouses was controlled to $16.3^{\circ}C$ and $14.6^{\circ}C$ during the experiment, respectively. The average water temperature in heating pipes was $52.3^{\circ}C$ and $45.0^{\circ}C$, respectively. Experimental results showed that natural convection heat transfer coefficient of heating pipe surface was in the range of $5.71{\sim}7.49W/m^2^{\circ}C$. When the flow rate in heating pipe was 0.5m/s or more, temperature difference between hot water and pipe surface was not large. Based on this, overall heat transfer coefficient of heating pipe was derived as form of laminar natural convection heat transfer coefficient in the horizontal cylinder. By modifying the equation of overall heat transfer coefficient, a formula for calculating the heat emission per unit length of hot water heating pipe was developed, which uses pipe size and temperature difference between hot water and indoor air as input variables. The results of this study were compared with domestic and foreign data, and it was found to be closest to JGHA data. The data of NAAS, BALLS and ASHRAE were judged to be too large. Therefore, in order to set up environmental design standards for domestic greenhouses, it is necessary to fully examine those data through further experiments.

A experimental Feasibility of Magnetic Resonance Based Monitoring Method for Underground Environment (지하 환경 감시를 위한 자기공명 기반 모니터링 방법의 타당성 연구)

  • Ryu, Dong-Woo;Lee, Ki-Song;Kim, Eun-Hee;Yum, Byung-Woo
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.596-608
    • /
    • 2018
  • As urban infrastructure is aging, the possibility of accidents due to the failures or breakdowns of infrastructure increases. Especially, aging underground infrastructures like sewer pipes, waterworks, and subway have a potential to cause an urban ground sink. Urban ground sink is defined just as a local and erratic collapse occurred by underground cavity due to soil erosion or soil loss, which is separated from a sinkhole in soluble bedrock such as limestone. The conventional measurements such as differential settlement gauge, inclinometer or earth pressure gauge have a shortcoming just to provide point measurements with short coverage. Therefore, these methods are not adequate for monitoring of an erratic subsidence caused by underground cavity due to soil erosion or soil loss which occurring at unspecified time and location. Therefore, an alternative technology is required to detect a change of underground physical condition in real time. In this study, the feasibility of a novel magnetic resonance based monitoring method is investigated through laboratory tests, where the changes of path loss (S21) were measured under various testing conditions: media including air, water, and soil, resonant frequency, impedance, and distances between transmitter (TX) and receiver (RX). Theoretically, the transfer characteristic of magnetic field is known to be independent of the density of the medium. However, the results of the test showed the meaningful differences in the path loss (S21) under the different conditions of medium. And it is found that the reflection coefficient showed the more distinct differences over the testing conditions than the path loss. In particular, input reflection coefficient (S11) is more distinguishable than output reflection coefficient (S22).

A Study on the Characteristics of Mortar Using Foaming Agents (기포제(起泡劑)를 사용(使用)한 모르터의 제특성(諸特性)에 관(關)한 연구(硏究))

  • Sung, Chan Yong
    • Korean Journal of Agricultural Science
    • /
    • v.15 no.1
    • /
    • pp.82-94
    • /
    • 1988
  • This study was performed to obtain the basic data which can be applied to use of foaming mortars. The results obtained were summarized as follows ; 1. The lowest water-cement ratios were shown at the mixing ratio of 1 : 1. But, it was gradually increased in poorer mixing ratio and decreased in more addition of foaming agent. The water-cement ratios were decreased up to 1.6-53.1% by mix-foaming type and 4.4-24.1% by pre-foamed type than cement mortar. 2. The highest bulk densities were shown at the mixing ratio of 1 : 1. But, it was gradually decreased in poorer mixing ratio and more addition of foaming agent. The decreasing rates of bulk densities were increased in richer mixing ratio and more addition of foaming agent. 3. The bulk densities were decreased up to 38.8-55.9% by mix-foaming type and 9.7-23.6% by pre-foamed type than cement mortar. 4. The lowest absorption rates were shown at the mixing ratio of 1 : 1. But, it was gradually increased in poorer mixing ratio and more addition of foaming agent. The increasing rates of absorption rates were increased in richer mixing ratio and more addition of foaming agent. 5. Absorption rates when immersed in 72hours were shown up to 3.41-5.85 times greater by mix-foaming type and 1.05-1.55 times greater by pre-foamed type than those of cement mortar. it was significantly higher at the early stage of immersed time than cement mortar. 6. The highest strengths were shown at the mixing ratio of 1 : 1. But, it was gradually decreased in poorer mixing ratio and more addition of foaming agent. The decreasing rates of strengths were increased in poorer mixing ratio and more addition of foaming agent. 7. The strengths were decreased up to 77.0-92.8% by mix-foaming type and 36.7-74.4% by pre-foamed type than cement mortar. 8. The lowest air contents were shown at the mixing ratio of 1 : 1. But, it was gradually increased in poorer mixing ratio and more addition of foaming agent. The increasing rates of air contents were increased in richer mixing ratio and more addition of foaming agent. 9. Air contents were shown up to 26.0-63.8 times greater by mix-foaming type and 5.8-17.7 times greater by pre-foamed type than those of cement mortar. 10. The correlations between bulk density, absorption rate, compressive strength and air content were highly significant. The multiple regression equations of bulk density, absorption rate, compressive strength, tensile strength, bending strength and air content were computed depending on a function of mixing ratio and addition of foaming agent. They were generally highly significant.

  • PDF

Conditions for Formation of Synnemata from Beauveria bassiana (백강균의 분생자병속 형성 조건)

  • Lee, Ki-Man;Nam, Sung-Hee;Yoon, Cheol-Sik;Jeon, Ji-Young;Yeo, Joo-Hong;Lee, Kwang-Gill
    • Korean journal of applied entomology
    • /
    • v.49 no.1
    • /
    • pp.43-47
    • /
    • 2010
  • This study was conducted to investigate optimal conditions for formation of synnemata from Beauveria bassiana. The strain of B. bassiana was isolated from a host of Oncotympana fuscata in Halla mountain of Jeju island. The yield of synnemata was the highest at application of brown rice (90%) and silkworm pupae (10%) media. On the other hand, the other media did not result in formation of synnemata. The highest formation of synnemata was achieved at conditions of moderate air inflow and $20^{\circ}C$. The optimal moisture and light intensity for formation of synnemata were 60% and 300 lux, respectively. In addition, inoculation of the liquid spawn resulted in higher yield than that of asexual spore.

Determination of a Grain Size for Reducing Cache Miss Rate of Direct-Mapped Caches (직접 사상 캐쉬의 캐쉬 실패율을 감소시키기 위한 성김도 정책)

  • Jung, In-Bum;Kong, Ki-Sok;Lee, Joon-Won
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.27 no.7
    • /
    • pp.665-674
    • /
    • 2000
  • In data parallel programs incurring high cache locality, the choice of grain sizes affects cache performance. Though the grain sizes chosen provide fair load balance among processors, the grain sizes that ignore underlying caching effect result in address interferences between grains allocated to a processor. These address interferences appear to have a negative impact on the cache locality, since they result in cache conflict misses. To address this problem, we propose a best grain size driven from a cache size and the number of processors based on direct mapped cache's characteristic. Since the proposed method does not map the grains to the same location in the cache, cache conflict misses are reduced. Simulation results show that the proposed best grain size substantially improves the performance of tested data parallel programs through the reduction of cache misses on direct-mapped caches.

  • PDF