• Title/Summary/Keyword: 위 배출

Search Result 360, Processing Time 0.03 seconds

Determination of management water level for the storage and flood controls in the underflow type of multi-stage movable weir using artificial neural network (인공신경망을 이용한 다단 배치된 하단배출형 가동보의 저류 및 홍수 조절을 위한 관리수위 결정)

  • Lee, Ji Haeng;Han, Il Yeong;Choi, Heung Sik
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.2
    • /
    • pp.111-119
    • /
    • 2017
  • The underflow type movable weirs were arranged in a multi-stage way along a reach at the Chiseong River, where flooding has been observed frequently. With management water level of the movable weirs the control effects of storage and flood were suggested and the control effects were compared with those of existed weir system. The water level for the targeted storage and flood elevation was suggested by building the artificial neural network model. When the underflow type of movable weirs were arranged in a multi-stage way, the peak flood elevation decreased by 68.28% in the downstream compared with the existed weir system, and the total storage of the target section of multi-stage movable weirs increased by 216%. As a result of numerical simulation to build the artificial neural network model, 60%, 20%, and 20% among 216 data were used for the training, validation, and test, respectively. The training result of mean square error was $0.1681m^2$ and the high coefficients of determination were 0.9961, 0.9967, and 0.9943 in the training, validation, and test, respectively. As a result the water level management of each movable weir for the controls of flood elevation in the targeted downstream and targeted storage was suggested by using the artificial neural network.

A study on the Energy Consumption and the Greenhouse gas Emission intensity of Detached Houses in Daegu (대구광역시 단독주택의 에너지 및 온실가스 배출원단위 작성에 관한 연구)

  • Kim, Ju-Young;Kim, Yu-Lan;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.89-94
    • /
    • 2009
  • The purpose of this study is to provide a fundamental data for reducing energy consumption and greenhouse gas emission of detached houses by investigating the energy consumption characteristic of detached houses in Daegu. Although the ratio of the detached houses decreases, the detached houses are common dwelling form next to apartments. Nevertheless the study about the energy consumption of detached houses has been insufficient compared apartments. There is a necessity which will investigate the energy consumption characteristic of detached houses. Because that with the building quality which is various form is different from apartments. This study investigate construction and equipment conditions and analyzing effective factors on energy consumption of detached houses. And this study draw up the energy consumption unit and emission factors unit for greenhouse gas of detached houses. This study represent a basic report for energy consumption reduction and helps effective use of energy.

  • PDF

Cephalexin 함유 생체점착성 마이크로캅셀의 제조 및 생물약제학적 평가

  • Kim, Jung-Hwan;Jung, Yeon-Bok;Han, Gun;Ji, Woong-Gil
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1994.04a
    • /
    • pp.346-346
    • /
    • 1994
  • 1. 위장관통과 실험결과 polycarbphil 흑은 carbomer로 코팅한 생체막점착성 마이크로캅셀 모두가 Eudragit RS/RL 마이크로캅셀보다 위 및 소장상부에 다량 존재하는 것으로 보아 Polymer의 생체막점착성에 의해 제제의 위내용배출이 억제되었음을 알 수 있었다. 2. Polycarbophil 흑은 carbomer로 코팅한 생체점착성 마이크로캅셀의 AUC는 Eudragit RS/RL 마이크로캅셀의 결과에 비해 현저히 증가되었다. Polycarbophil로 코팅한 생체막점착성 마이크로캅셀은 carbomer로 코팅한 제제에 비해 Cm의 증가뿐아니라 전체적인 약물흡수의 증가와 높은 혈중농도의 지속을 보여주어 생체막점착성 제제의 이상적인 약물흡수패턴을 보여주었다. 3. 흡수속도효율 (ARE)면에서 생체막점착성 마이크로캅셀이 코팅전의 마이크로캅셀에 비해 약간 떨어졌으나, polycarbophil 코팅제제의 경우 전체적인 흡수양상이 마이크로캅셀에 비해 우수하고 또한 제어방출효율 (CRE)이 현저하게 증가되어 생체막점착성 제제로서의 유용성을 확인할 수 있었다. 4. 위내용배출의 지연효과, AUC, CRE 등을 종합해 볼때, Polycarbophil 로 코팅한 생체막점착성 마이크로캅셀은 투여횟수의 감소 및 생체이용율을 향상시키는 유용한 제제로 평가되었다.

  • PDF

A Study on the Energy Consumption and Greenhouse Gas Emission of the Detached Houses in Daegu (대구광역시 단독주택의 에너지 및 온실가스 배출원단위 작성에 관한 연구)

  • Kim, Yu-Lan;Yoon, Hae-Kyung;Kim, Ju-Young;Jeon, Gyu-Yeob;Hong, Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.22 no.2
    • /
    • pp.35-42
    • /
    • 2011
  • In the energy consumption of buildings in Korea, the housing sector accounts for 53% of a total energy consumption. Although the researches of energy consumption on the new detached houses and apartment houses have been conducted numerous times, the researches of energy consumption characteristics on the existing detached houses are lack of studies. Thus in this study, the actual condition of energy consumption characteristics on the existing detached houses in Daegu city was examined, and then energy consumption unit and green house gas emission unit was compiled to present a fundamental data for an effective way of reducing energy consumption and greenhouse gas emission in the buildings. The results showed that the energy consumption for heating in the existing detached house was greater than other energy consumption and the heating energy sources were city gas and fuel oil. As the fuel oil consumption got larger, the energy consumption unit and greenhouse gas emission unit became bigger. Based on these results, it will be able to develop a plan for reducing energy and greenhouse gas emission in the existing detached houses in the future.

Efficient of Hepatobiliary Scintigraphy both Decubitus Position in Biliary Leakage Patients (간담도 스캔 시 담즙 누출(Biliary Leakage)환자에서의 양측와위 자세(Both Decubitus Position)의 유용성)

  • Bahn, Young-Kag;Roh, Dong-Ook;Kang, Chun-Koo;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.229-234
    • /
    • 2008
  • Hepatobiliary scintigraphy is very sensitivity of hepatic cell and gallbladder, biliary track atresia and biliary leakage. however, Hepatobiliary scan of biliary leakage diagnosis was separated determine biliary leakage and bowl drainage bile-juice. The object of this study will determine biliary leakage and bowl drainage bile-juice to hepatobiliary scintigraphy both decubitus position in bile leakage patients. Material & Methode: 31 patients (meal 14, Femeal 17), $51.1{\pm}14.4$ years. dynamic scan acquisition 60 farme for 60 minute on supine position. and delay scan was 2 hrs, 4 hrs, 24 hrs for 5 minute on supine, both decubitus position. Both decubitus position scan was kept for 5 minutes. Efficient of Hepatobiliary Scintigraphy both decubitus position in bile leakage patients was compared leakage size, density, image of supine position and both decubitus position. Results: 23 patients for 31 bile leakage patients was checked up function image or delay image, and 8 patients was checked up bile leakage on both decubitus. anatomical leakage location was supine position very well, but both decubitus position was separated bile leakage and moving bile-juice in bowl. also, uptake (counts/pixel) average of roi and bkg was supine 5.02, left decubitus 2.08, right decubitus 2.68. No. pixels of supine ROI counted 1.91 times than left decubitus, 1.05 times than right decubitus. Conclusion: 31 patient both decubitus position, but decubitus position was separated bile juice movement in bowl leakage location. also, It was compared ROI/BKG ratio and ROI No. pixels of supine, both decubitus in 38.5% patients. And No. pixels of supine position was large 19%, 5% than left decubitus, right decubitus, And density was in low 60%, 50% than left decubitus, right decubitus. It was mean bile leakage of ROI. so, If Hepatobiliary Scintigraphy was additional both decubitus position scan in bile leakage patients, this study will be more valuable in diagnosis of bile leakage.

  • PDF

Generation of Food Waste from Different Sources and Its Composting Measures at the Apartment Complex (배출원별 음식물 쓰레기 발생 특성 및 아파트 단지에서의 퇴비화 방안 (대전 및 충청남도 지역을 중심으로))

  • Kang, H.;Lee, O.L.;Kim, J.W.;Hur, H.W.;Han, S.H.
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.6 no.1
    • /
    • pp.53-66
    • /
    • 1998
  • This study was carried out to investigate the typical composition of food waste from municipal solid wastes (MSW) and unit food waste generation rates from different sources in the model cities and to study the food waste management system from unit household to composting facilities. The annual average food waste composition of MSW was determined as 49% in Taejon and 52% in Chungnam Province, respectively. No big difference in food waste composition was found among the different sources. Since the paper waste generally occupied the half of food waste, over 75% of MSW was found to be compostable or biodegradable. Per capita food waste generation rate, 200~250g/capita day was determined by the direct measurement from 32 households, while 380g/capita day for Chungnam Province and 400 g/capita day for Taejon were estimated by the load count analysis In the sanitary landfills. This difference means people contribute generating food waste at outside house approximately twice as much as that at inside house. Per capita food waste generation rates from several sources were determined as follows; 166~215g/capita day at municipalities, 400g/visitor day at a first class hotel, 170g/student day at a university restaurant. Food waste generation from restaurant was strongly dependant upon it's level or quality; 670g/capita day at the high level restaurant, 190g/capita day at the middle class and 60 g/capita day at the lower class restaurant. The food waste reduction rate in a In situ fermentor showed 30~40g/kg day.

  • PDF

International Environmental Efficiency with CO2 Using Meta Stochastic Frontier Analysis (메타확률 프런티어를 사용한 CO2의 국제환경효율)

  • Li, Ziyao;Kang, Sangmok
    • Environmental and Resource Economics Review
    • /
    • v.30 no.3
    • /
    • pp.471-501
    • /
    • 2021
  • We measure Environmental Efficiency (EE) based on CO2 in four income groups from 1998 to 2018, using the Meta Stochastic Frontier Analysis method by Input Distance Function. Our results showed that economic growth and energy consumption would increase carbon dioxide emissions, and increasing labor and capital input will reduce it. Moreover, we compared Group Environmental Efficiency (GEE), Meta Environmental Efficiency (MEE), and Environmental Gap Ratio (EGR). The results showed that GEEs were be overestimated. Furthermore, the MEE showed a downward trend during this period. The lower-middle-income group had the highest EGR performance. High-income and upper-middle-income groups showed less efficiency in MEE and EGR. To improve environmental efficiency, we must reduce fossil fuels and find more scientific and technological ways to solve existing environmental problems as soon as possible.

Studies on the overinflation of the Cardiac Stomach in Sterlet Sturgeon Acipenser ruthenus, fingerlings (양식 스털렛 철갑상어, Acipenser ruthenus 치어의 위 팽창 증후군에 관한 연구)

  • Park, Sung-Woo;Yu, Jin-Ha;Han, Jung-Jo
    • Journal of fish pathology
    • /
    • v.25 no.1
    • /
    • pp.59-65
    • /
    • 2012
  • Overinflation of cardiac stomach occurred in farmed sterlet sturgeon (Acipenser ruthenus) fingerlings. Affected fish congregated and swam upside-down near the edges of the tanks with abdominal distension. When pressed the dilated abdomen, the fish often exhibited a normal swimming pattern for some time, then resumed their characteristic upside-down swimming patterns. Internally, the fish showed abdominal dropsy and dilated stomach filled with yellowish granular contents. When the contents in the stomach, fish feed, water and excrement in the farm inoculated on Sabouraud destrose agar (SDA) at $25^{\circ}C$ for 48 hr. Candida sp. were isolated except from the feed. Candida sp. in excrement or water in the farm may enter into the stomach with feed and then produce gases in the metabolic process, which in turn may cause the stomach overinflation.

Literature survey, Modeling by Measured unit load Qulaty Assurance (문헌조사, 단일지목 모델링을 통한 실측 원단위 신뢰성검토)

  • Park, Jae-Beom;Kang, Du-Kee;Kal, Byung-Seok;Yoon, Young-Sam;Lee, Je-Guan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.284-288
    • /
    • 2011
  • 비점오염원 원단위는 적용이 간편하기 때문에 많은 국가에서 비점오염원 유출량을 산정하기 위하여 사용하고 있다. 그러나 비점오염원의 유출은 지역, 지형, 기후, 토지이용 등과 같은 여러 가지 조건들에 따라 배출양상이 다양하게 나타나므로 신뢰성 있는 원단위를 산정하기 위해서는 장기간에 걸친 실측자료가 뒷받침되어야 한다. 우리나라에서는 지난 1980년대 초부터 비점오염 원단위에 대한 연구가 시작되었으며 수많은 문헌과 연구에서 비점오염원 유출특성을 제시하고 있다. 따라서 본 연구에서는 지난 3년간 낙동강 수계에서 모니터링된 비점오염원 자료를 통하여 유출모형인 SWMM(Storm Water Management Model) 구축하고 또한 구축된 모형을 이용하여 실측한 자료를 통한 EMC값과 기존 문헌에서 제시하고 있는 EMC값을 서로 비교함으로서 본 연구에서 제시하고 있는 EMC값의 적정성 및 선행 자료에서 제시하고 있는 값들의 범위를 분석하고자 하였다. 따라서, 본 연구는 모델링을 통하여 비점오염원 유출특성을 파악함과 동시에 실측값 및 기존 문헌에서 제시 하고 있는 EMC를 비교 분석함으로서 적정한 비점오염원의 EMC 값 범위를 파악하여 지목별 비점오염원 원단위 산정에 큰 도움이 되리라 판단된다.

  • PDF

Research on Changes and Characteristics of GHG Emissions by Major Energy-consuming Universities in Korea - Focused on the variation since the implementation of GHG emission regulation by Government - (에너지 다소비 대학의 온실가스 배출 변화와 특성 - 온실가스 배출 규제 시행 이후의 변화를 중심으로 -)

  • Jung, Hyejin;Kim, In Chol
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.1
    • /
    • pp.74-82
    • /
    • 2017
  • It is known that energy usage from Korean Universities was growing rapidly in the early 2000s. But since 2011, the change was caused by GHG emissions regulation enforced by the government. The purpose of this research was to find the characteristics and trends of greenhouse gas emissions from major universities in Korea according to the each university's data and information. The result shows that GHG emissions from University have increased steadily prior to enforcement by 4-5% annually, but the rate of increase marked 0.5~1% in 2011~2013 is the season of emission regulation and the total amount of emissions decreased 3%~5% in 2014~2015 while preparing an emissions trading scheme. Therefore we can say that the enforcement of GHG reduction such as energy target management system makes a visible effect at least in the University sector that level of GHG emissions is from $75kg/m^2$ to $58Kg/m^2$ for seven years. Another result says that the size of research fund is the main factor that affects the amount of GHG emissions before 2011, but the size of building area has been a new factor influencing the GHG emission since 2013. Thus we suggest that the criteria for evaluating the level of GHG emission from University is suitable if it is based on the building area intensity.