• Title/Summary/Keyword: 위험 거리

Search Result 587, Processing Time 0.029 seconds

Operation Measures of Sea Fog Observation Network for Inshore Route Marine Traffic Safety (연안항로 해상교통안전을 위한 해무관측망 운영방안에 관한 연구)

  • Joo-Young Lee;Kuk-Jin Kim;Yeong-Tae Son
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.2
    • /
    • pp.188-196
    • /
    • 2023
  • Among marine accidents caused by bad weather, visibility restrictions caused by sea fog occurrence cause accidents such as ship strand and ship bottom damage, and at the same time involve casualties caused by accidents, which continue to occur every year. In addition, low visibility at sea is emerging as a social problem such as causing considerable inconvenience to islanders in using transportation as passenger ships are collectively delayed and controlled even if there are local differences between regions. Moreover, such measures are becoming more problematic as they cannot objectively quantify them due to regional deviations or different criteria for judging observations from person to person. Currently, the VTS of each port controls the operation of the ship if the visibility distance is less than 1km, and in this case, there is a limit to the evaluation of objective data collection to the extent that the visibility of sea fog depends on the visibility meter or visual observation. The government is building a marine weather signal sign and sea fog observation networks for sea fog detection and prediction as part of solving these obstacles to marine traffic safety, but the system for observing locally occurring sea fog is in a very insufficient practical situation. Accordingly, this paper examines domestic and foreign policy trends to solve social problems caused by low visibility at sea and provides basic data on the need for government support to ensure maritime traffic safety due to sea fog by factually investigating and analyzing social problems. Also, this aims to establish a more stable maritime traffic operation system by blocking marine safety risks that may ultimately arise from sea fog in advance.

Radiation Absorbed Dose Calculation Using Planar Images after Ho-166-CHICO Therapy (Ho-166-CHICO 치료 후 평면 영상을 이용한 방사선 흡수선량의 계산)

  • 조철우;박찬희;원재환;왕희정;김영미;박경배;이병기
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.155-162
    • /
    • 1998
  • Ho-l66 was produced by neutron reaction in a reactor at the Korea Atomic Energy Institute (Taejon, Korea). Ho-l66 emits a high energy beta particles with a maximum energy of 1.85 MeV and small proportion of gamma rays (80 keV). Therefore, the radiation absorbed dose estimation could be based on the in-vivo quantification of the activity in tumors from the gamma camera images. Approximately 1 mCi of Ho-l66 in solution was mixed into the flood phantom and planar scintigraphic images were acquired with and without patient interposed between the phantom and scintillation camera. Transmission factor over an area of interest was calculated from the ratio of counts in selected regions of the two images described above. A dual-head gamma camera(Multispect2, Siemens, Hoffman Estates, IL, USA) equipped with medium energy collimators was utilized for imaging(80 keV${\pm}$10%). Fifty-nine year old female patient with hepatoma was enrolled into the therapeutic protocol after the informed consent obtained. Thirty millicuries(110MBq) of Ho-166-CHICO was injected into the right hepatic arterial branch supplying hepatoma. When the injection was completed, anterior and posterior scintigraphic views of the chest and pelvic regions were obtained for 3 successive days. Regions of interest (ROIs) were drawn over the organs in both the anterior and posterior views. The activity in those ROIs was estimated from geometric mean, calibration factor and transmission factors. Absorbed dose was calculated using the Marinelli formula and Medical Internal Radiation Dose (MIRD) schema. Tumor dose of the patient treated with 1110 MBq(30 mCi) Ho-l66 was calculated to be 179.7 Gy. Dose distribution to normal liver, spleen, lung and bone was 9.1, 10.3, 3.9, 5.0 % of the tumor dose respectively. In conclusion, tumor dose and absorbed dose to surrounding structures were calculated by daily external imaging after the Ho-l66 therapy for hepatoma. In order to limit the thresholding dose to each surrounding organ, absorbed dose calculation provides useful information.

  • PDF

A Study on Radiation Exposure Dose of Patients and Operator during Percutaneous Vertebroplasty (경피적 추체 성형술 시행 시 환자와 시술자의 방사선 피폭선량에 관한 연구)

  • Lee, Jae-Heon;Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.139-144
    • /
    • 2017
  • Percutaneous vertebroplasty (PVP) is increasingly used to treat osteoporotic vertebral fractures, myeloma and osteolytic vertebral metastases. The purpose of this study was to measure the absorbed radiation exposure dose and time during PVP and to assess the possibility of deterministic radiation effects to the operator and patient. The radiation dose and time measure by three pain physicians performed consecutive procedures using the twenty case PVP. Patient's dosimeter placed at the anteroposterior(AP) side was treatment of the vertebra body located in the upper level 2-3 and lateral(LAT) side was flank proximal to C-arm tube of back. Operator's dosimeter placed at the apron outside of upper sternum (thyroid), left chest, lower extremity and apron inside of left chest. Results: Radiation exposure times were $3.6{\pm}0.71min$. Measurements on the Patient radiation dose were AP $121.4{\pm}48.1{\mu}Sv$, LAT side $614.7{\pm}177.1{\mu}Sv$. Operator radiation dose were outside of the lead apron upper sternum $33.7{\pm}7.3{\mu}Sv$, outside of the lead apron chest $49.2{\pm}15.0{\mu}Sv$, outside of the lead apron lower extremity $12.8{\pm}3.8{\mu}Sv$ and inside of the lead apron chest $4.2{\pm}1.4{\mu}Sv$. To escape from the danger of radiation first long distance from the c-arm tube second exposure time reduced second lead apron used fluoroscopy during PVP is more safety patient and operation from the radiation exposure.

Minimizing Estimation Errors of a Wind Velocity Forecasting Technique That Functions as an Early Warning System in the Agricultural Sector (농업기상재해 조기경보시스템의 풍속 예측 기법 개선 연구)

  • Kim, Soo-ock;Park, Joo-Hyeon;Hwang, Kyu-Hong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.24 no.2
    • /
    • pp.63-77
    • /
    • 2022
  • Our aim was to reduce estimation errors of a wind velocity model used as an early warning system for weather risk management in the agricultural sector. The Rural Development Administration (RDA) agricultural weather observation network's wind velocity data and its corresponding estimated data from January to December 2020 were used to calculate linear regression equations (Y = aX + b). In each linear regression, the wind estimation error at 87 points and eight time slots per day (00:00, 03:00, 06:00, 09.00, 12.00, 15.00, 18.00, and 21:00) is the dependent variable (Y), while the estimated wind velocity is the independent variable (X). When the correlation coefficient exceeded 0.5, the regression equation was used as the wind velocity correction equation. In contrast, when the correlation coefficient was less than 0.5, the mean error (ME) at the corresponding points and time slots was substituted as the correction value instead of the regression equation. To enable the use of wind velocity model at a national scale, a distribution map with a grid resolution of 250 m was created. This objective was achieved b y performing a spatial interpolation with an inverse distance weighted (IDW) technique using the regression coefficients (a and b), the correlation coefficient (R), and the ME values for the 87 points and eight time slots. Interpolated grid values for 13 weather observation points in rural areas were then extracted. The wind velocity estimation errors for 13 points from January to December 2019 were corrected and compared with the system's values. After correction, the mean ME of the wind velocities reduced from 0.68 m/s to 0.45 m/s, while the mean RMSE reduced from 1.30 m/s to 1.05 m/s. In conclusion, the system's wind velocities were overestimated across all time slots; however, after the correction model was applied, the overestimation reduced in all time slots, except for 15:00. The ME and RMSE improved b y 33% and 19.2%, respectively. In our system, the warning for wind damage risk to crops is driven by the daily maximum wind speed derived from the daily mean wind speed obtained eight times per day. This approach is expected to reduce false alarms within the context of strong wind risk, by reducing the overestimation of wind velocities.

The efficacy of continuous positive airway pressure (CPAP) for patient with left breast cancer (좌측 유방암 방사선치료에서 CPAP(Continuous Positive Airway Pressure)의 유용성 평가)

  • Jung, Il Hun;Ha, Jin Sook;Chang, Won Suk;Jeon, Mi Jin;Kim, Sei Joon;Jung, Jin Wook;Park, Byul Nim;Shin, Dong Bong;Lee, Ik Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose: This study examined changes in the position of the heat and lungs depending on the patient's breathing method during left breast cancer radiotherapy and used treatment plans to compare the resulting radiation dose. Materials and methods: The participants consisted of 10 patients with left breast cancer. A CT simulator(SIMENS SOMATOM AS, Germany) was used to obtain images when using three different breathing methods: free breathing(FB), deep inspiration breath hold(DIBH with Abches, DIBH), inspiration breath hold(IBH with CPAP, CPAP). A Ray Station(5.0.2.35, Sweden) was used for treatment planning, the treatment method was volumetric modulated arc therapy (VMAT) with one partial arc of the same angle, and the prescribed dose to the planning target volume (PTV) was a total dose of 50Gy(2Gy/day). In treatment plan analysis, the 95% dose (D95) to the PTV, the conformity index(CI), and the homogeneity index (HI) were compared. The lungs, heart, and left anterior descending artery (LAD) were selected as the organs at risk(OARs). Results: The mean volume of the ipsilateral lung for FB, DIBH, and CPAP was 1245.58±301.31㎤, 1790.09±362.43 ㎤, 1775.44±476.71 ㎤. The mean D95 for the PTV was 46.67±1.89Gy, 46.85±1.72Gy, 46.97±23.4Gy, and the mean CI and HI were 0.95±0.02, 0.96±0.02, 0.95±0.02 and 0.91±0.01, 0.90±0.01, 0.92±0.02. The V20 of Whole Lung was 10.74±4.50%, 8.29±3.14%, 9.12±3.29% and The V20 of the ipsilateral lung was 20.45±8.65%, 17.18±7.04%, 18.85±7.85%, the Dmean of the heart was 7.82±1.27Gy, 6.10±1.27Gy, 5.67±1.56Gy, and the Dmax of the LAD was 20.41±7.56Gy, 14.88±3.57Gy, 14.96±2.81Gy. The distance from the thoracic wall to the LAD was measured to be 11.33±4.70mm, 22.40±6.01mm, 20.14±6.23mm. Conclusion: During left breast cancer radiotherapy, the lung volume was 46.24% larger for DIBH than for FB, and 43.11% larger for CPAP than FB. The larger lung volume increases the distance between the thoracic wall and the heart. In this way, the LAD, which is one of the nearby OARs, can be more effectively protected while still satisfying the treatment plan. The lung volume was largest for DIBH, and the distance between the LAD and thoracic wall was also the greatest. However, when performing treatment with DIBH, the intra-fraction error cannot be ignored. Moreover, communication between the patient and the radiotherapist is also an important factor in DIBH treatment. When communication is problematic, or if the patient has difficulty holding their breath, we believe that CPAP could be used as an alternative to DIBH. In order to verify the clinical efficacy of CPAP, it will be necessary to perform long-term follow-up of a greater number of patients.

Prehospital Status of the Patients with Ischemic Chest Pain before Admitting in the Emergency Department (허혈성 흉통 환자의 응급의료센터 방문 전 상황)

  • Jin, Hye-Hwa;Lee, Sam-Beom;Do, Byung-Soo;Chun, Byung-Yeol
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.1
    • /
    • pp.41-54
    • /
    • 2007
  • Background : The causes of chest pain vary but the leading cause of chest pain is ischemic heart disease. Mortality from ischemic chest pain has increased more than two fold over the last ten years. The purpose of this study was to determine the data necessary for rapid treatment of patients with signs and symptoms of ischemic chest pain in the emergency department (ED). Materials and Methods : We interviewed 170 patients who had ischemic chest pain in the emergency department of Yeungnam University Hospital over 6 months with a protocol developed for the evaluation. The protocol used included gender, age, arriving time, prior hospital visits, methods of transportation to the hospital, past medical history, final diagnosis, and outcome information from follow up. Results : Among 170 patients, there were 118 men (69.4%) and the mean age was 63 years. The patients diagnosed with acute myocardial infarction (AMI) were 106 (62.4%) and with angina pectoris (AP) were 64 (37.6%). The patients who had visited another hospital were 68.8%, twice the number that came directly to this hospital (p<0.05). The ratio of patients who visited another hospital were higher for the AMI (75.5%) than the AP (59.4%) patients (p<0.05). The median time spent deciding whether to go to hospital was 521 minutes and for transportation was 40 minutes. With regard to patients that visited another hospital first, the median time spent at the other hospital was 40 minutes. The total median time spent before arriving at our hospital was 600 minutes (p>0.05). The patients who had a total time delay of over 6 hours was similar 54.8% in the AMI group and 57.9% in the AP group (p>0.05). As a result, only 12.2% of the patients with an AMI received thrombolytics, and 48.8% of them had a simultaneous percutaneous coronary intervention (PCI). In the emergency department 8.5% of the patients with an AMI died. Conclusion : Timing is an extremely important factor for the treatment of ischemic heart disease. Most patients arrive at the hospital after a long time lapse from the onset of chest pain. In addition, most patients present to a different hospital before they arrive at the final hospital for treatment. Therefore, important time is lost and opportunities for treatment with thrombolytics and/or PCI are diminished leading to poor outcomes for many patients in the ED. The emergency room treatment must improve for the identification and treatment of ischemic heart disease so that patients can present earlier and treatment can be started as soon as they present to an emergency room.

  • PDF

Research for Space Activities of Korea Air Force - Political and Legal Perspective (우리나라 공군의 우주력 건설을 위한 정책적.법적고찰)

  • Shin, Sung-Hwan
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.18
    • /
    • pp.135-183
    • /
    • 2003
  • Aerospace force is a determining factor in a modem war. The combat field is expanding to space. Thus, the legitimacy of establishing aerospace force is no longer an debating issue, but "how should we establish aerospace force" has become an issue to the military. The standard limiting on the military use of space should be non-aggressive use as asserted by the U.S., rather than non-military use as asserted by the former Soviet Union. The former Soviet Union's argument is not even strongly supported by the current Russia government, and realistically is hard to be applied. Thus, the multi-purpose satellite used for military surveillance or a commercial satellite employed for military communication are allowed under the U.S. principle of peaceful use of space. In this regard, Air Force may be free to develop a military surveillance satellite and a communication satellite with civilian research institute. Although MTCR, entered into with the U.S., restricts the development of space-launching vehicle for the export purpose, the development of space-launching vehicle by the Korea Air Force or Korea Aerospace Research Institute is beyond the scope of application of MTCR, and Air Force may just operate a satellite in the orbit for the military purpose. The primary task for multi-purpose satellite is a remote sensing; SAR sensor with high resolution is mainly employed for military use. Therefore, a system that enables Air Force, the Korea Aerospace Research Institute, and Agency for Defense Development to conduct joint-research and development should be instituted. U.S. Air Force has dismantled its own space-launching vehicle step by step, and, instead, has increased using private space launching vehicle. In addition, Military communication has been operated separately from civil communication services or broadcasting services due to the special circumstances unique to the military setting. However, joint-operation of communication facility by the military and civil users is preferred because this reduces financial burden resulting from separate operation of military satellite. During the Gulf War, U.S. armed forces employed commercial satellites for its military communication. Korea's participation in space technology research is a little bit behind in time, considering its economic scale. In terms of budget, Korea is to spend 5 trillion won for 15 years for the space activities. However, Japan has 2 trillion won annul budget for the same activities. Because the development of space industry during initial fostering period does not apply to profit-making business, government supports are inevitable. All space development programs of other foreign countries are entirely supported by each government, and, only recently, private industry started participating in limited area such as a communication satellite and broadcasting satellite, Particularly, Korea's space industry is in an infant stage, which largely demands government supports. Government support should be in the form of investment or financial contribution, rather than in the form of loan or borrowing. Compared to other advanced countries in space industry, Korea needs more budget and professional research staff. Naturally, for the efficient and systemic space development and for the prevention of overlapping and distraction of power, it is necessary to enact space-related statutes, which would provide dear vision for the Korea space development. Furthermore, the fact that a variety of departments are running their own space development program requires a centralized and single space-industry development system. Prior to discussing how to coordinate or integrate space programs between Agency for Defense Development and the Korea Aerospace Research Institute, it is a prerequisite to establish, namely, "Space Operations Center"in the Air Force, which would determine policy and strategy in operating space forces. For the establishment of "Space Operations Center," policy determinations by the Ministry of National Defense and the Joint Chief of Staff are required. Especially, space surveillance system through using a military surveillance satellite and communication satellite, which would lay foundation for independent defense, shall be established with reference to Japan's space force plan. In order to resolve issues related to MTCR, Air Force would use space-launching vehicle of the Korea Aerospace Research Institute. Moreover, defense budge should be appropriated for using multi-purpose satellite and communication satellite. The Ministry of National Defense needs to appropriate 2.5 trillion won budget for space operations, which amounts to Japan's surveillance satellite operating budges.

  • PDF

Outer Space Activities and an Observation of Related Laws of Korea (국내 우주활동과 관련법 소고)

  • Park, Won-Hwa
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.24 no.2
    • /
    • pp.163-186
    • /
    • 2009
  • The missile technology and its development in south Korea have been restrained to the limit of 180 km by America which instead provided to Korea with security protection. In the same vein, America pressured South Korea to abort its nuclear weapons program so as to prevent another possible military encounter that can easily develop into a war between South and North Korea. This restraint was a bit relaxed when South Korea joined the Missile Technology Control Regime (MTCR) in 2001 whereby the limit was 300 km. The situation of South Korea is in much contrast with its neighbor, North Korea, which has fired Taepo Dong 1 and Taepo Dong 2 to put its alleged satellite respectively into the Earth orbit. The range of this rocket believed to be reaching more than 5,500 km, a range of the intercontinental ballistic missile, without any rein. South Korea that has just geared its full powers for its outer space industry, with the current space projects of putting its satellites into the low Earth orbit, will in future put its satellite into the geostationary orbit, 36,000 km above the Earth. To do so, such restraint had better be resolved. Korean space industry, as it is alike in other countries, started with putting and manufacturing sounding rockets, producing satellites but relying on foreign launching facilities, and learning launching capacities. Experiencing three time launchings of KITSAT, the current satellite projects of Korea are undertaken as follows: - Koreasat - STSAT - Komsat - MBSAT - COMS (Communication, Ocean, and Meteorological Satellite) Koreans waked up to the things of outer space in 2008 with the first Korean astronaut Li So-yeon, a lady bio systems engineer. Although the first Korean made rocket in cooperation with a Russian company to fire last August 2009 was a failure, it should be considered as an inevitable process for future endeavors. There are currently three outer space related laws of Korea: Aerospace Industry Development Promotion Act 1987, Outer Space Development Promotions Act 2005, and Space Damage Compensation Act 2008. The first two stemming from the two different ministries are, however, overlapping in many aspects and have some shortcomings to be improved.

  • PDF

Efficacy of a Protective Grass Shield in Reduction of Radiation Exposure Dose During Interventional Radiology (방사선학적 중재적 시술시 납유리의 방사선 방어효과에 관한 연구)

  • Jang, Young-Ill;Song, Jong-Nam;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.303-308
    • /
    • 2011
  • Background/Aims : The increasing use of diagnostic and therapeutic interventional radiology calls for greater consideration of radiation exposure risk to radiologist and radiological technician, and emphasizes the proper system of radiation protection. This study was designed to assess the effect of a protective grass shield. Methods : A protective grass was following data depth, 0.8 cm; width, 100 cm; length, 100 cm, lead equivalent, 1.6 mmPb. The protective shield was located between the patient and the radiologist. Thirty patients (13 male and 17 female) undergoing interventional radiology between September 2010 and December 2010 were selected for this study. The dose of radiation exposure was recorded with or without the protective grass shield at the level of the head, chest, and pelvis. The measurement was made at 50 cm and 150 cm from the radiation source. Results : The mean patient age was 69 years. The mean patient height and weight was $159.7{\pm}6.7$ cm and $60.3{\pm}5.9$ kg, respectively. The mean body mass index (BMI) was $20.5{\pm}3.0$ kg/m2. radiologists received $1530.2{\pm}550.0$ mR/hr without the protective lead shield. At the same distance, radiation exposure was significantly reduced to $50.3{\pm}85.2$ mR/hr with the protective lead shield (p-value<0.0001). The radiation exposure to radiologist and radiological technician was significantly reduced by the use of a protective lead shield (p value <0.0001). The amount of radiation exposure during interventional radiology was related to the patient' BMI (r=0.749, p=0.001). Conclusions : This protective shield grass is effective in protecting radiologist and radiological technician from radiation exposure.

Comparison treatment planning with the measured change the dose of each Junction section according to the error of setup CSI Treatment with Conventional, IMRT, VMAT (Conventional, IMRT, VMAT을 이용한 CSI 치료시, Setup 오차에 따른 각 Junction부의 선량변화측정을 통한 치료계획 비교)

  • Lee, Ho Jin;Jeon, Chang Woo;Ahn, Bum Suk;Yu, Sook Hyeon;Park, So Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.217-224
    • /
    • 2014
  • Purpose : Conventional, IMRT, at CSI treatment with VMAT, this study compare the treatment plan with dose changes measured at Junction field according to the error of Setup. Materials and Methods : This study established Conventional, the IMRT, VMAT treatment planning for CSI therapy using the Eclipse 10.0 (Eclipse10.0, Varian, USA) and chose person in Seoul National University Hospital. Verification plan was also created to apply IMRT QA phantom for each treatment plan to the film measurements. At this time, the error of Setup was applied to the 2, 4, 6mm respectively with the head and foot direction. ("+" direction of the head, "-" means that the foot direction.) Using IMRT QA Phantom and EBT2 film, was investigated by placing the error of Setup for each Junction. We check the consistency of the measured Film and plan dose distribution by gamma index (Gamma index, ${\gamma}$). In addition, we compared the error of Setup by the dose distribution, and analyzing the uniformity of the dose distribution within the target by calculating the Homogeneity Index (HI). Results : It was figured out that 90.49%-gamma index we obtained with film is agreement with film scan score and dose distribution of treatment plan. Also, depend on the dose distribution on distance, if we make the error of Setup 2, 4, 6mm in the head direction, it showed that 3.1, 4.5, 8.1 at $^*Diff$(%) of Conventional, 1.1, 3.5, 6.3 at IMRT, and 1.6, 2.5, 5.7 at VMAT. In the same way, if we make the error of Setup 2, 4, 6mm in the foot direction, it showed that -1.6, -2.8, -4.4 at $^*Diff$(%) of Conventional, -0.9, -1.6, -2.9 at IMRT, and -0.5, -2.2, -2.5 at VMAT. Homogeneity Index(HI)s are 1.216 at Conventional, 1.095 at IMRT and 1.069 at VMAT. Discussion and Conclusion : The dose-change depend on the error of Setup at the CSI RT(radiation therapy) using IMRT and VMAT which have advantages, Dose homogeneity and the gradual dose gradients on the Junction part is lower than that of Conventional CSI RT. This a little change of dose means that there is less danger on patients despite of the error of Setup generated at the CSI RT.