• Title/Summary/Keyword: 위치 색인

Search Result 627, Processing Time 0.034 seconds

Late Quaternary Stratigraphy of the Tidal Deposits In the Hampyung Bay, southwest coast of Korea (한국 서남해 함평만 조간대 퇴적층의 제4기 후기 층서 연구)

  • Park, Yong-Ahn;Lim, Dhong-Il;Choi, Jin-Yong;Lee, Young-Gil
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.2 no.2
    • /
    • pp.138-150
    • /
    • 1997
  • The late Quaternary stratigraphy of the tidal deposits in the Hampyung Bay, southwestern coast of Korea comprises 1) Unit III (nonmarine fluvial coarse-grained sediments), 2) Unit II (late Pleistocene tidal deposits), and 3) Unit I (late Holocene fine-grained tidal deposits) in ascending order. The basements of the Hampyung Bay is composed of granitic rocks and basic dyke rocks. These three units are of unconformally bounded sedimentary sequences. The sequence boundary between Unit I and Unit II, in particular, seems to be significant suggesting erosional surface and exposed to the air under the cold climate during the LGM. The uppermost stratigraphic sequence (Unit I) is a common tidal deposit formed under the transgression to highstand sea-level during the middle to late Holocene.

  • PDF

유리화 비정형 탄소(vitreous carbon)를 이용하여 제작한 전계방출 소자의 균일성 증진방법

  • 안상혁;이광렬
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.53-53
    • /
    • 1999
  • 전계방출을 이용한 평판 표시장치는 CRT가 가진 장점을 모두 갖는 동시에 얇고 가벼우며 낮은 전력소모로 완벽한 색을 구현할 수 있는 차세대 표시장치로서 이에 대한 여국가 활발히 이루어지고 있다. 여기에 사용되는 음극물질로서 실리콘이나 몰리 등을 팁모양으로 제작하여 사용해 왔다. 하지만 잔류가스에 의한 역스퍼터링이나 화학적 반응에 의해서 전계방출 성능이 점차 저하되는 등의 해결해야할 많은 문제가 있다. 이러한 문제들을 해결하기 위하여 탄소계 재료로서 다이아몬드, 다이아몬드상 카본 등을 이용하려는 노력이 진행되어 왔다. 이중 유리화 비정형 탄소는 다량의 결함을 가지고 있는 유리질의 고상 탄소 재로로서, 전기전도도가 우수하면서 outgassing이 적고 기계적 강도가 뛰어나며 고온에서도 화학적으로 안정하여 전계방출 소자의 음극재료로서 알맞은 것으로 생각된다. 유리화 비정형 탄소가루를 전기영동법으로 기판에 코팅하여 전계방출 소자를 제작하였다. 전기영동 용액으로 이소프로필알코올에 질산마그네슘과 소량의 증류수, 유리화 비정형 탄소분말을 섞어주었고 기판으로는 몰리(Mo)가 증착된 유리를 사용하였다. 균일한 증착을 위해서 증착후 역전압을 걸어 주는 방법과 증착 후 플라즈마 처리를 하는 등의 여러 가지 방법을 사용했다. 전계방출 전류는 1$\times$10-7Torr이사에서 측정하였다. 1회 제작된 용액으로 반복해서 증착한 횟수에 따라 표면의 거치기, 입자의 분포, 전계방출 측정 결과 등의 차이가 관찰되었다. 발광이미지는 전압에 따라 변화하였고, 균일한 발광을 관찰하기 위해서 오랜 시간동안 aging 과정을 거쳐야 했다. 그리고 구 모양의 양극을 사용해서 위치를 변화시키며 시동 전기장을 관찰하여 위치에 따른 전계방출의 차이를 조사하여 발광의 균일성을 알 수 있었다.on microscopy로 분석하였으며 구조 분석은 X-선 회절분석, X-ray photoelectron spectroscopy 그리고Auger electron spectroscope로 하였다. 증착된 산화바나듐 박막의 전기화학적 특성을 분석하기 위하여 리튬 메탈을 anode로 하고 EC:DMC=1:1, 1M LiPF6 액체 전해질을 사용한 Half-Cell를 구성하여 200회 이상의 정전류 충 방전 시험을 행하였다. Half-Cell test 결과 박막의 결정성과 표면상태에 따라 매우 다른 전지 특성을 나타내었다.도상승율을 갖는 경우가 다른 베이킹 시나리오 모델에 비해 효과적이라 생각되며 초대 필요 공급열량은 200kW 정도로 산출되었다. 실질적인 수치를 얻기 위해 보다 고차원 모델로의 해석이 필요하리라 생각된다. 끝으로 장기적인 관점에서 KSTAR 장치의 베이킹 계획도 살펴본다.습파라미터와 더불어, 본 연구에서 새롭게 제시된 주기분할층의 파라미터들이 모형의 학습성과를 높이기 위해 함께 고려된다. 한편, 이러한 학습과정에서 추가적으로 고려해야 할 파라미터 갯수가 증가함에 따라서, 본 모델의 학습성과가 local minimum에 빠지는 문제점이 발생될 수 있다. 즉, 웨이블릿분석과 인공신경망모형을 모두 전역적으로 최적화시켜야 하는 문제가 발생한다. 본 연구에서는 이 문제를 해결하기 위해서, 최근 local minimum의 가능성을 최소화하여 전역적인 학습성과를 높여 주는 인공지능기법으로서 유전자알고리즘기법을 본 연구이 통합모델에 반영하였다. 이에 대한 실증사례 분석결과는 일일 환율예측문제를 적용하였을 경우, 기존의 방법론보다 더 나운 예측성과를 타나내었다.pective" to workflow architectural discussions. The vocabulary suggested

  • PDF

A Characteristics Classification by Beads Analysis of the Tombs of Deokcheon-ri in Uljin, Korea. (울진 덕천리 신라묘군 출토 구슬류의 특성 고찰)

  • Lee, Minhee;Kim, Gyu-Ho
    • Conservation Science in Museum
    • /
    • v.22
    • /
    • pp.69-84
    • /
    • 2019
  • This study investigated the formal characteristics and chemical compositions of eighty beads excavated from a Silla tomb complex at Deokcheon-ri, Uljin in order to reveal the methods of production and the characteristics of the raw materials involved, thereby illuminating characteristics of the relics from each tomb. The beads excavated from these Silla tombs include one curved bead, one tubular bead, and 78 globular beads. Among them, the curved and tubular beads and three globular beads were identified to be made of minerals, and the remaining 75 beads are made of glass. Most of the glass beads are thought to have been produced using the drawing technique. The characteristics of the beads were classified according to their site of excavation. The globular beads from Tomb No. 34 belong to the lead-barium glass and potash glass groups, indicating that these beads were produced at a relatively earlier period in time. The glass beads excavated from the tombs in the northern portion of the complex differ in color and chemical composition from those in the southern portion, which indicates the character that each group of beads had different aspect according to site location. Considering that the excavated beads were mainly from fifth- and sixth-century tombs, it is likely that certain groups of people living around Uljin used and buried beads in their tombs. As the governance of Silla became more centralized in the sixth century, the use of beads for burial purpose appears to have come to an end in this region.

Analysis for Practical use as KOMPSAT-2 Imagery for Product of Geo-Spatial Information (지형공간정보 생성을 위한 KOPMSAT-2 영상의 활용성 분석)

  • Lee, Hyun-Jik;You, Ji-Ho;Koh, Young-Chang
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.1
    • /
    • pp.21-35
    • /
    • 2009
  • KOMPSAT-2 is the seventh high-resolution image satellite in the world that provides both 1m-grade panchromatic images of the GSD and 4m-grade multispectral images of the GSD. It's anticipated to be used across many different areas including mapping, territory monitoring and environmental watch. However, due to the complexity and security concern involved with the use of the MSC, the use of KOMPSAT-2 images are limited in terms of geometric images, such as satellite orbits and detailed mapping information. Therefore, this study aims to produce DEM and orthoimage by using the stereo images of KOMPSAT-2, and to explore the applicability of geo-spatial information with KOMPSAT -2. Orientation interpretations were essential for the production of DEM and orthoimage using KOMPSAT-2 images. In the study, they are performed by utilizing both RPC and GCP. In this study, the orientation interpretations are followed by the generation of DEM and orthoimage, and the analysis of their accuracy based on a 1:5,000 digital map. The accuracy analysis of DEM is performed and the results indicate that their altitudes are, in general, higher than those obtained from the digital map. The altitude discrepancies on plains, hills and mountains are calculated as 1.8m, 7.2m, and 11.9m, respectively. In this study, the mean differences between horizontal position between the orthoimage data and the digital map data are found to be ${\pm}3.081m$, which is in the range of ${\pm}3.5m$, within the permitted limit of a 1:5,000 digital map. KOMPSAT-2 images are used to produce DEM and orthoimage in this research. The results suggest that DEM can be adequately used to produce digital maps under 1:5,000 scale.

  • PDF

Diagnosis and Post-Therapeutic Evaluation of Arteriovenous Malformations in Extremities Using Transarterial Lung Perfusion Scintigraphy (경동맥 폐관류 신티그라피를 이용한 상하지 동정맥 혈관기형의 진단과 치료 평가)

  • Chung, Hyun-Woo;Choi, Joon-Young;Kim, Young-Wook;Kim, Dong-Ik;Do, Young-Soo;Lee, Eun-Jeong;Lee, Su-Jin;Cho, Young-Seok;Hyun, Seung-Hyup;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.316-321
    • /
    • 2006
  • Purpose: Differential diagnosis between arteriovenous (AVMs) aud non-arteriovenous malformations (nAVMs) is important in patients with congenital vascular malformations, because AVMs can cause hemodynamic alteration and require immediate treatment. We investigated whether transarterial lung perfusion scintigraphy (TLPS) was useful for the diagnosis and post-therapeutic evaluation of AVMs in extremities. Materials and Methods: Fifty-seven patients (M:F=26:31, $21{\pm}13$ yr, 9 upper and 48 lower extremities) suspected of congenital vascular malformations in extremities underwent TLPS using $^{99m}Tc-MAA$ before embolization/sclerotherapy. Dose-corrected shunt fraction (SF) was calculated from time-activity curve of the lung. Final diagnosis of AVMs was determined by angiography. in patients with AVMs, follow-up TLPS was done for post-therapeutic evaluation. Results: Sixteen patients (8 upper and 8 lower extremities) had AVMs, while the remaining 41 had nAVMs (1 upper and 40 lower extremities). The mean SF of AVMs on TLPS was significantly higher than that of nAVMs ($66.4{\pm}25.8%\;vs.\;2.8{\pm}4.3%$), p=0.003). The sensitivity, specificity, and accuracy of TLPS (cut-off of SF = 20.0%) in diagnosis of AVMs before treatment were 93.8% (15/16), 100% (41/41) and 98.2% (56/57), respectively. The follow-up TLPS and angiography for post-therapeutic evaluation showed concordant results in 13 of 16 patients (81.3%) with AVMs. The mean SF of TLPS was significantly decreased after embolization/sclerotherapy ($69.5{\pm}24.0%\;vs.\;41.0{\pm}34.7%$, p=0.01). Conclusion: TLPS provides hemodynamic information of AVMs in extremities semiquantitatively. Furthermore, the results of TLPS showed a high concordance rate with angiographic findings. Therefore, TLPS is useful for the diagnosis and post-therapeutic evaluation of AVMs in extremities.

INFLUENCE OF THE COLOR OF COMPOSITE RESINS APPLIED TO LINGUAL SURFACE ON THE LABIAL TOOTH COLOR (설측 복합레진 색상이 치아 순측 색상에 미치는 영향)

  • Mun, Seung-Hui;Park, Su-Jung;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.309-323
    • /
    • 2009
  • In this study we evaluated the influence of both the thickness of residual enamel and the color of the composite resins applied to lingual surface on the labial surface color. Background plates were made by randomly (A1, A2, A6D, B1, B2, B3, C1, C2, C6D) selected colors of Filtek Supreme (3M ESPE, St. Paul, U.S.A.) composite resin. Crown portion of 9 maxillary central incisors were cut off and embedded with acrylic resin except labial surface. Samples of average thickness of 2.2 mm were obtained after cutting it in a thickness of 2.5 mm from the labial surface and sandpaper polish. The shade of composite resin background was measured using Spectrophotometer ($Spectrolino^{(R)}$, GretagMacbeth, Regensdorf, Switzerland). And CIE $L^{\ast}a^{\ast}b^{\ast}$value of 2.2 mm thickness tooth samples were measured on the 9 composite resin backgrounds. And then, the cutting side of tooth samples was ground to the extent of 1.9 mm, 1.6 mm, 1.3 mm, 1.0 mm and placed on composite resin backgrounds and measured $L^{\ast}a^{\ast}b^{\ast}$values with the same method. In all samples, $L^{\ast}$value and $b^{\ast}$value seemed to have a tendency of decreasing as thickness of tooth sample becomes thinner regardless of background colors (p < 0.05). But, $a^{\ast}$value didn't show the significant differences depending on the thickness.

Agronomic Characteristics and Seed Quality of Cowpea (Vigna unguiculata L.) Germplasm (동부 유전자원의 작물학적 특성과 종실품질)

  • Kim, Dong-Kwan;Son, Dong-Mo;Choi, Jin-Gyung;Shin, Hae-Ryong;Choi, Kyeong-Ju;Lee, Jeongran;Lee, Kyung-Dong;Rim, Yo-Sup
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.58 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • The purpose of this study was to provide basic information for breeding cowpeas (Vigna unguiculata L.) by investigating the crop characteristics of 245 accessions of cowpea collected in Korea and abroad. All specimens flowered within 41 to 50 days (51.5%) or 51 to 60 days (43.7%) of sowing and matured 21 to 30 days (53.9%) or 31 to 40 days (23.7%) from flowering. Thus, the total time from sowing to maturity was either 71 to 80 days (26.9%) or 81 to 90 days (23.4%) for all specimens. The accessions were classified into indeterminate type (72.7%), intermediate type (25.7%) and determinate type (1.6%) based on growth; prostrate type (78.8%) and erect type (21.2%) based on plant type; heart shape (98.4%) and lanceolate (1.6%) based on leaflet shape; and purple (85.2%), white (13.6%) and light green (1.2%) based on corolla color. The accessions were classified into brown (54.7%) and yellowish brown (37.6%) based on color at pod maturity; and downward (90.6%), middle (5.7%) and standing upright (3.7%) based on pod setting position. Seed coat color varied as 25.3% were brown, 23.3% were black, and 20.8% were white. Seed shape also varied as 66.9% were egg-shaped, 24.9% were rectangular and 8.2% were kidney-shaped. Pod lengths ranged from 10.1-20.0 cm and from 20.1-30.0 cm in 89.0% and 8.6% of specimens, respectively. There were 12.1-15.0, 9.1-12.0, and 15.1-18.0 seeds per pod in 62.0%, 25.7% and 9.1% of specimens, respectively. The weight of one hundred seeds ranged from 15.1-20.0 g (37.6%) and 10.1-15.0 g (28.6%). Seed yields per plant were 100.1-200.0 g (52.7%), less than 100 g (22.9%), and 200.1-300.0 g (15.9%). The starch content in the seeds of the seven selected resources ranged from 44.1 to 57.0% while the protein content ranged from 23.3 to 27.5% with significant differences. The sucrose content ranged from 1.46 to 2.03%, also with significant differences.

A New Soy-paste Soybean Cultivar, 'Nampung' with Disease Resistance, Good Combining Adaptability and High Yielding (장류용 내병 내재해 기계수확 적응 콩 신품종 '남풍')

  • Kim, Hyun-Tae;Baek, In-Youl;Ko, Jong-Min;Han, Won-Young;Park, Keum-Yong;Oh, Ki-Won;Yun, Hong-Tae;Moon, Jung-Kyung;Shin, Sang-Ouk;Kim, Sun-Lim;Oh, Young-Jin;Lee, Jong-Hyeong;Choi, Jae-Keun;Kim, Chang-Heung;Lee, Seung-Su;Jang, Young Jik;Kim, Dong-Kwan;Son, Chang-Ki;Kang, Dal-Soon;Kim, Yong-Deuk
    • Korean Journal of Breeding Science
    • /
    • v.42 no.6
    • /
    • pp.721-726
    • /
    • 2010
  • 'Nampung', a new soybean cultivar for soy-paste, was developed from the cross between Suwon190 and 'Pokwangkong' by soybean breeding team at the National Institute of Crop Science (NICS) in 2007. A promising line, SS97215-S-S-20, was selected and designated as the name of Milyang162. It was prominent and had good result from regional adaptation yield trials(RYT) for three years from 2005 to 2007 and was released as the name of 'Nampung'. It has a determinate growth habit, white flower, brown pubescence, yellow seed coat, light brown hilum, medium spherical seed (19.9 grams per 100 seeds). 'Nampung' is resistant to soybean mosaic virus and bacterial pustule, the major soybean disease in Korea. It is possible to harvest of 'Nampung' using combine because of it's lodging tolerance, few branches, and high position of pod attachment. The average yield of 'Nampung' is 2.97 ton per hectare in the regional yield trials (RYT) carried out for three years from 2005 to 2007 which is 21 percent higher than the check variety, 'Taekwang'.

CT Findings of Bronchogenic Cyst (기관지 낭종의 전산화단층촬영 소견)

  • Cho, Hyun-Cheol;Lee, Yong-Woo;Hwang, Mi-Soo;Cho, Kil-Ho;Byun, Woo-Mok;Cho, Jae-Ho;Chang, Jae-Chun;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.2
    • /
    • pp.226-236
    • /
    • 1995
  • We studied to evaluate CT characteristics of bronchogenic cysts. We retrospectively evaluated CT of 11 patients with pathologically proved bronchogenic cyst. Precontrast and postcontrast CT scan was performed in all. We analyzed CT with viewpoints of location, size, attenuation on pre- and postcontrast scan, and calcification. Three of 11 bronchogenic cysts were intrapulmonary in location and eight were located in the mediastinum. Two of 3 intrapulmonary bronchogenic cysts were located in the right lower lobe, and the remaining one was left lower lobe. Intrapulmonary bronchogenic cysts ranged from 6cm to 12cm in diameter (average, 9.7 cm). On CT, intrapulmonary bronchogenic cysts appeared as thin-wall air cyst, homogenous water attenuation and soft tissue attenuation with air bubble respectively. Mediastinal bronchogenic cysts were located in posterior mediastinum(n=5), superior mediastinum(n=2), middle mediastinum(n=1) respectively. These cysts ranged in size from 3cm to 8cm in diameter (average, 5.0 cm). On CT, five showed homogenous water attenuation, two soft tissue attenuation similar to that of muscle, one air-fluid level. Calcification or contrast enhancement was not detected in any cases. On operative findings, all of intrapulmonary bronchogenic cysts contained dirty pus-like material and all of mediastinal bronchogenic cysts contained whitish or yellowish mucus material. Bronchogenic cysts showed homogenous water density in many cases, homogenous soft tissue density, air-fluid level and air-filled cyst. The constellation of CT findings may be helpful in the diagnosis and differentiation of bronchogenic cyst.

  • PDF

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.