• Title/Summary/Keyword: 위치정도

Search Result 3,354, Processing Time 0.027 seconds

Quality Assurance of Leaf Speed for Dynamic Multileaf Collimator (MLC) Using Dynalog Files (Dynalog file을 이용한 동적다엽조준기의 Leaf 속도 정도관리 평가)

  • Kim, Joo Seob;Ahn, Woo Sang;Lee, Woo Suk;Park, Sung Ho;Choi, Wonsik;Shin, Seong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.305-312
    • /
    • 2014
  • Purpose : The purpose of this study is to analyze the mechanical and leaf speed accuracy of the dynamic multileaf collimator (DMLC) and determine the appropriate period of quality assurance (QA). Materials and Methods : The quality assurance of the DMLC equipped with Millennium 120 leaves has been performed total 92 times from January 2012 to June 2014. The the accuracy of leaf position and isocenter coincidence for MLC were checked using the graph paper and Gafchromic EBT film, respectively. The stability of leaf speed was verified using a test file requiring the leaves to reach maximum leaf speed during the gantry rotation. At the end of every leaf speed QA, dynamic dynalog files created by MLC controller were analyzed using dynalog file viewer software. This file concludes the information about the planned versus actual position for all leaves and provides error RMS (root-mean square) for individual leaf deviations and error histogram for all leaf deviations. In this study, the data obtained from the leaf speed QA were used to screen the performance degradation of leaf speed and determine the need for motor replacement. Results : The leaf position accuracy and isocenteric coincidence of MLC was observed within a tolerance range recommanded from TG-142 reports. Total number of motor replacement were 56 motors over whole QA period. For all motors replaced from QA, gradually increased patterns of error RMS values were much more than suddenly increased patterns of error RMS values. Average error RMS values of gradually and suddenly increased patterns were 0.298 cm and 0.273 cm, respectively. However, The average error RMS values were within 0.35 cm recommended by the vendor, motors were replaced according to the criteria of no counts with misplacement > 1 cm. On average, motor replacement for gradually increased patterns of error RMS values 22 days. 28 motors were replaced regardless of the leaf speed QA. Conclusion : This study performed the periodic MLC QA for analyzing the mechanical and leaf speed accuracy of the dynamic multileaf collimator (DMLC). The leaf position accuracy and isocenteric coincidence showed whthin of MLC evaluation is observed within the tolerance value recommanded by TG-142 report. Based on the result obtained from leaf speed QA, we have concluded that QA protocol of leaf speed for DMLC was performed at least bimonthly in order to screen the performance of leaf speed. The periodic QA protocol can help to ensure for delivering accurate IMRT treatment to patients maintaining the performance of leaf speed.

A Relationship between Corneal Type, Corneal Astigmatism and Lens Fitting States and the Stable Centration of Spherical RGP Lens (각막형상, 각막난시 및 렌즈 피팅상태와 구면 RGP렌즈의 중심안정위치와의 상관 관계)

  • Lim, Shin Gyu;Lee, Min Ha;Choi, Sun Mi;Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.143-151
    • /
    • 2012
  • Purpose: The present study was conducted to investigate whether there is any difference in the centration of spherical RGP lens on cornea according to corneal types, corneal astigmatism and lens fitting states. Methods: Spherical RGP lens was fitted on 29 eyes of round-typed cornea and 45 eyes of symmetric bowtie-typed cornea with 0.00~2.75 D of corneal astigmatism in alignment, steep or flat. Their lens centrations on cornea were analyzed by taking photographs. Results: The centration of spherical RGP lens in the vertical direction was decentrated to downward direction in all cases, and the degree of decentration was not consistent. The lens centration in horizontal direction was significantly more-decentrated to the temporal meridian as base curve of lens was increased, and the degree of decentration was different according to the corneal type, corneal astigmatism and fitting states. With the same degree of astigmatism, the lens decentration to the temporal meridian was bigger in round-typed cornea than that in symmetirc bowtie-typed cornea. Conclusions: The centration of spherical RGP lens varies depending on lens fitting states, corneal astigmatism, and corneal types. Thus, the consideration of these factors may improve the success rate in RGP lens prescription.

Changes in Compression Strength of Corrugated Paperboard Box in Several Conditions (몇가지 조건하에서 골판지 상자의 압축강도 변화)

  • Park, Hyung-Woo;Ha, Young-Sun;Lee, Song-Dong;Kong, Jae-Hong;Kim, Su-Il
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.258-261
    • /
    • 1989
  • Corrugated paperboard box is used to package of agricultural, fishery and industrial products in Korea. Test of compression strength results as follows. Compressing strength according to the insertion of inner pad was improved in 9.0% to 48.5%, Slitting length and width in 3.0% to 16.0% Compression strength according to the position of transportation hole was different 1.6% to 10.1%, the jointing method 7% to 10.3%, the printing width was decreased in 18.4% to 19.1%.

  • PDF

A Study on Measurement of Linear Cycle Plane Positioning Accuracy of NC Lathe (NC선반의 직선 사이클 평면 위치결정 정도 측정에 관한 연구)

  • 김영석;송인석;정정표;한지희;윤원주
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.2
    • /
    • pp.53-58
    • /
    • 2003
  • It is very important to measure linear cycle plane positioning accuracy of NC lathe as it effects all other parts of machines machined by them in industries. If the plane positioning accuracy of NC lathe is bad, the dimension accuracy and the change-ability of works will be bad in the assembly of machine parts. In this paper, computer software systems are organized to measure linear cycle plane positioning displacement of ATC(Automatic tool changer) on zx plane of NC lathe using two linear scales. And each sets of error data obtained from the test is descriptions to plots and the results of linear cycle plane positioning errors are expressed as nutriments by computer treatment.

Gartner´s Duct Cyst in a Maltese Bitch (말티즈 암캐에 있어 Gartner´s Duct 낭종례)

  • 정원일;이차수;박상준;정규식
    • Journal of Veterinary Clinics
    • /
    • v.18 no.2
    • /
    • pp.182-184
    • /
    • 2001
  • 2001년 4월 19일에 11살 된 말티즈 암캐의 비정상적 자궁에 대한 검사의뢰가 들어왔다. 육안적 검사에서 얇은 막으로 된 다양한 자궁 낭종이 관찰되었다. 그 수는 5개이며 그중 2개는 자궁체의 장막면에 위치하고 있었으며 7∼8 mm 정도의 직경을 가지고 있었다. 나머지 3개는 직경 1∼2 mm 정도의 크기이며 자궁각의 장막면에 위치하고 있었고, 절개시 모든 낭종들은 장액성 액체들로 가득 차 있었다. 병리조직학적 검사에서는 모든 낭종들이 자궁의 장막하에 존재하고 있었다. 낭종의 상피세포들과 이들의 위치는 모두 Gartner's duct와 동일한 것들이었고, 따라서 Gartner's duct cyst로 진단하게 되었다.

  • PDF

A Study on the Design of Variable Reference Tap Position Equalizer for Synchronous Microwave Tansmission Systems (동기식 마이크로파 전송시스템을 위한 기준탭 위치 가변방식 등화기 설계에 관한 연구)

  • 이대영;장태화;방효창;김원후
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.4
    • /
    • pp.373-381
    • /
    • 1997
  • Digital microwave transmission systems are equipped with equalizer against fading during multipath fading. In this paper, we proposed variable reference tap position equalizer that varies the reference tap according to fading type to archive better performance. We got the performance improvement about 4~5 dB in MP condition and 2~3 dB in NMP condition from simulation results.

  • PDF

Glottic and subglottic airway obtruction

  • 김영모
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 2003.09a
    • /
    • pp.113-113
    • /
    • 2003
  • 성문과 성문하부의 기도 폐쇄는 위치 정도 원인 기간 등은 환자에 따라 다르고 그 치료방법 역시 다양하다. 주 원인으로는 기관내 삽관, 각종 외상 및 화상 등 을 들 수 있다. 이러한 질환의 치료 목적은, 기관내 튜브나 기관 캐뉼러 를 통하지 않고 비강을 통하여 자연스럽게 호흡할 수 있도록 기도를 유지 하면서 발성이 가능하고 기고 흡인 없이 연하가 가능하도록 하며 기침 반사가 원활하게 되도록 하는데 있다. 치료목적의 달성을 위하여 협착의 경우, 단계 즉 초기 단계 또는 성숙단계 여부, 위치, 정도, 범위 환자의 연령 전신상태 등을 술전에 잘 평가하고 수술도중의 소견과 술자의 경험이나 기호에 따라 적절한 치료법을 선택하여 치료해야 한다. 후두 외상에 의한 기도 문제는 다른 외상에 비해 흔하지 않은데 이는 연골의 유연성과 후두의 가동성 그리고 후두가 하악과 흉골사이에 위치하여 외상시 보호받게 되는 해부학적 특성에 기인한다. 여러 요인으로 인하여 진단이 늦어질 수도 있는데 이러한 경우 심각한 증상이 초래 되거나 치료가 의 시기가 지나 후두 또는 기관 협착, 발성장애등의 후유증이 유발 될 수 있다.

  • PDF

Geoelectric surveys in the southern part of the Yangsan Fault

  • Lee, Gi Hwa;Han, Won Seok
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.2
    • /
    • pp.111-122
    • /
    • 1999
  • 한반도 남동부 경상분지에 위치한 양산단층의 지전기학적 구조를 밝히기 위하여 경주시 이조리와 울산시 서하리, 양산시 삼감리와 회산리 사이에서 전기비저항 탐사를 수행하였다. 단층파쇄대는 낮은 전기비저항값을 가지며 단층파쇄대에 분포하는 풍화대는 남쪽으로 향할수록 두꺼워지는 것으로 나타났다. 풍화대의 깊이는 서하리와 회산리에서 약 100 m 이며 다른 지역에서는 약 50-70 m 정도이다. 단층파쇄대에 위치하는 풍화대의 전기비저항값은 회산리에서 얻어진 약 10 Ωm의 매우 낮은 값을 제외하고는 약 40-300 Ωm 정도이다. 연구지역 내에서는 풍화대 하부에 위치하는 기반암의 깊이가 양산단층을 따라 남쪽으로 향할수록 깊어지는 특징적인 변화 양상을 갖는 것으로 보인다. 수평탐사 결과는 양산단층에 가까워질수록 겉보기 비저항값이 감소함을 보여준다

  • PDF

Automatic Shape Control for the stainless cold mill using Fuzzy method (퍼지 기법을 이용한 STS 강판의 형상제어)

  • Hur, Yone-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.2869-2871
    • /
    • 1999
  • 본 연구는 포항제철 STS 냉연공장의 형상 제어에 관한 것이다 당사의 냉간 압연기는 Sendzimir mill로서 상하 롤(Roll)이 10단씩 구성된 20단 압연기이다. 본 압연기에 의한 575 냉연강판의 형상제어는 현재 조업자의 수동운전으로 구동되고 있으며 구동기는 AS_U Roll 8 개와 Intermediate Roll 2 개의 10 개로 구성되어 있다. 구동기의 특성은 solenoid 형태와 유압식으로서 응답성이 빠르지 뭇하다. 본 연구는 위와 같은 특성을 지닌 냉간 압연기를 가지고 퍼지 제어에 의한 자동제어의 구현에 관한 것이다. 본 연구에 사용된 퍼지 제어기는 형상 강판의 두께 Roll 속도, AS_U Roll과 IMR의 현 위치 강종 강판의 폭, 강판의 장력 등의 입력을 고려하여 제어기의 출력인 AS_U Roll 8 개의 위치 값과 IMR 2 개의 위치 값을 결정한다. 현재 실 프로세서에 적용중이며 형상제어 정도가 양호하다. 본 연구의 효과는 형상제어의 자동화 및 형상 정도 향상을 통한 조업 안정화에 있다.

  • PDF

Development of the Indoor Location Tracking Method Using Accelerometer and Gyroscope Sensor (가속도센서와 각속도센서를 이용한 실내 위치추적 기법 개발)

  • Jo, Kyung-min;Jung, Hwan;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.345-348
    • /
    • 2009
  • 본 연구에서는 실내에서의 위치추적을 위해 가속도 센서와 각속도 센서를 이용한 위치추적기법을 제안하였다. 기존의 실내 위치추적기법은 전파의 세기를 이용하여 위치추적을 수행하는 RSSI기법과 초음파를 이용한 방법이 제시되었다. 하지만 기존 실내위치추적 기법에서는 좌표 값을 알고 있는 고정된 노드를 필수적으로 사용해야하는 단점이 있다. 본 연구에서는 이러한 단점을 보완하기위하여 착용형 노드에 가속도센서와 각속도 센서를 부착하고 이동속도와 방향을 계측하여 실내에서의 위치추적을 수행하고자 하였다. 이를 위해 3축 가속도 센서와 2축의 각속도 센서를 사용하였으며, 센서로부터 출력되는 아날로그신호를 계측 및 무선전송하기 위하여 Zigbee기반의 무선 센서노드를 사용하였다. 무선센서노드로부터 측정된 가속도신호와 각속도 신호의 분석을 통해 실내위치추적 가능성을 평가하였으며, 평가 결과 가속도센서와 각속도 센서를 이용한 실내위치추적의 가능성을 확인하였다.

  • PDF