• 제목/요약/키워드: 위치정도

검색결과 3,350건 처리시간 0.033초

Accuracy of the Loran C Fix on the Route Between Pusan and Cheju (부산-제주 항로상에서 Loran C 위치정도)

  • 김민석
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • 제26권2호
    • /
    • pp.167-172
    • /
    • 1990
  • A number of studies for the improvement of the accuracy of the Loran C fix were carried out previously. But most studies were preformed when a ship was at anchorage, or in port. To investigate the accuracy of the Loran C fix when a ship was underway and in port, a series of observation was made on the route between Pusan and Cheju from Oct. 1988 to Oct. 1989. The obtained results are summerized as follows: 1. There is little difference in the accuracy of the Loran C fix by daytime and night, and the higher the mountain nearby ship, the greater the error of ship's position. 2. When a ship is at anchorage and underway, and the accuracy of ship's position is almost not affected by course while underway. 3. In order to promote the accuracy of the fixed position, a navigator must correct the propagation velocity and the geodetic system simultaneously, but in this paper the authors find that a most accurate position can be obtained by converting the geodetic system only.

  • PDF

Accuracy of Hybrid Navigation System Combining Dead Reckoning and Loran C (추측항법과 Loran C항법을 결합한 Hybrid 항법의 정도)

  • Lee, Won-Woo;Sin, Hyeong-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • 제20권2호
    • /
    • pp.105-111
    • /
    • 1984
  • Recently, Hybrid Navigation Systems combining Omega, NNSS, Loran C and Dead reckoning etc. served to give us highly accurate ship's position, and a number of ships are equipped with these navigation systems. In order to evaluate for the accuracy of this navigation system observations of Loran C, 5970 and 9970 chains and Radar at the same time were made on board m.s Jeonbuk 401 and 403 training ships of Gunsan Fisheries Collage at nine stations in the yellow sea from July, 1982 to June, 1983, and then were done by the Hybrid Navigation System combining Dead reckoning and Loran C at the same areas. The authors investigated the accuracy of the Hybrid Navigation System based on measurements of the relative positional error which is defined as the difference between the position fixed by this system or the Loran C system, and the one by the Radar. The obtained results are as follows; 1. The mean standard deviation of the time difference of Loran C were about 0.21$\mu$s in 9970 chain and about 0.06$\mu$s in 5970 chain, and the fluctuation of the time difference of Loran C in 5970 chain was smaller than that in 9970 chain. 2. The positional error between two positions by Radar and the Hybrid Navigation System in 9970 chain was about 0.4 miles, and between two positions by Radar and Loran C was about 0.51 miles. The Hybrid Navigation System was therefore more accurate than Loran C System. 3. The positional error between two positions by Radar and Hybrid Navigation System in 5970 chain was about 0.4 miles, and between two positions by Radar and computer simulation of Loran C was about 0.98 miles. Consequently, Hybrid Navigation System was more accurate than computer simulation of Loran C system.

  • PDF

기하학적 연쇄에 의한 공작물 형상의 장착오차해석에 관한 연구

  • 신동수;정성종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 1992년도 추계학술대회 논문집
    • /
    • pp.223-227
    • /
    • 1992
  • 산업의 발전으로 정밀가공기술 및 측정기술 및 측정기술의 개발에 대한 요구가 급증하고 있으며, 특히 가공전 공작물의 장착정도, 팔레트 교환 위치정도와 가공후 가공정도 및 공작기계 자체의 정도 판별은 생산품의 정밀도와 직접 관계되는 중요한 요인이기 때문에 정확히 규명할 필요가 있다. 본 연구에서는 공작물의 장착오차와 기계오차가 존재하는 경우 Denavit-Hartenberg 접근법에 의하여 레퍼런스에 대한 공간상 linkage의 기하학적 표현을 Matrix Multiplication을 사용하여 Cutting Tool 과 Workpiece에 대한 공간상의 관계를 규명하였으며, 가공에 미치는 체적오차를 규명하고자 한다.

Improvement of the Accuracy of Short Baseline Acoustic Positioning System (단기선 (SBL) 음향위치 시스템의 정도 개선)

  • 박해훈;윤갑동
    • Journal of the Korean Institute of Navigation
    • /
    • 제17권1호
    • /
    • pp.99-105
    • /
    • 1993
  • Underwater acoustic positioning systems have been extensively used not only in surface position fixing but also in underwater position fixing. Recently, these systems have been applied in the field of installation and underwater inspection offshore platforms etc. But in these systems are included the fixing errors as results of a signal with noise and irregular motion of vessel by ocean waves. In this paper to improve the accuracy of the position fixing a Kalman filter is applied to the short baseline(SBL) acoustic positioning system. The optimal position obtained by the Kalman filter is compared with the raw position and it is confirmed that the former is more accurate than the latter.

  • PDF

A Nucleotide Sequence Signature Extraction Method based on Position-Specific Relative Base Frequency Differences (위치기반 상대빈도차 기반의 바이러스 염기서열 시그너쳐 추출 기법)

  • Hwang, Gyeong-Sun;Lee, Hye-Ri;Lee, Geon-Myeong;Lee, Chan-Hui;Yun, Hyeong-U;Kim, Seong-Su
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 한국퍼지및지능시스템학회 2007년도 춘계학술대회 학술발표 논문집 제17권 제1호
    • /
    • pp.167-170
    • /
    • 2007
  • 동일한 집단에 속하는 개체를 다른 집단에 속하는 개체로부터 구별할 수 있는 염기의 특징을 해당 집단의 시그너쳐라고 한다. 학습 데이터는 두 집단에 속하는 염기서열들이고, 염기서열에 대한 시그너쳐는 개체를 다른 집단과 구별할 수 있는 위치의 염기들로 구성된 서열이다. 제안한 방법에서는 각 집단에 대해서 위치별로 염기의 발생빈도를 계산하고, 가장 발생빈도가 높은 염기를 결정한 다음, 다른 집단의 대응 위치에서 해당 염기의 빈도를 계산하여, 빈도차이가 지정한 분류임계값 이상이면, 해당 위치의 염기를 시그너쳐를 구성하는 특징으로 간주한다. 시그너쳐를 대한 임의의 염기서열에 대한 부합정도는 시그너쳐에 속하는 염기의 학습집단에서의 상대빈도값을 가중치로 하여 계산한다. 임의의 염기서열이 특정 집단에 속하는지 판단하기 위해서는 해당 집단의 시그너쳐에 대한 부합정도를 계산하게 되는데, 부합정도가 얼마이상이 되어야 해당 집단에 속하는 것으로 간주할지 기준이 되는 임계값을 엄밀도 임계값이라고 한다. 엄밀도 임계값은 학습 데이터 집합에 대해서 주어진 시그너쳐에 대한 엄밀도 임계값이 민감도와 특이도를 최대로 하는 것을 선택한다. 제안한 방법을 구현한 바이오인포매틱스 도구를 개발하여, 한국형 HIV-1 바이러스 시그너쳐 추출에 적용하여 분류특성이 우수한 시그너쳐를 추출할 수 있음을 확인하였다.

  • PDF

A study on improvement of positioning accuracy using DGPS technique with low cost GPS modules (저가의 GPS 모듈에 DGPS 기술을 이용한 위치측정정확도 개선에 관한 연구)

  • 이창복;안준석;주세철;김기두
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • 제12권2호
    • /
    • pp.155-161
    • /
    • 1994
  • Accurate positioning method using low cost GPS modules is proposed, which use the technique of differential GPS. DGPS experiments have been made using two coarse-acquisition (C/A) code GPS modules. Position accuracy of better than 5 m was obtained for position dilution of precision (PDOP) of 2-3 and that of better than 10 m after filtering was obtained for PDOP of about 9 in a local area. Static DGPS experiments were performed at Kookmin university with the DGPS correction data of KRISS reference station at Taejon. The distance between two stations is about 140 km. The results show that precision of the position is about 10 m (2 drms), which is ten times better than the results with the GPS module alone. Accuracy of about 10 meters can be obtained in near real time by the DGPS service with a reference station in our country.

  • PDF

Real Time On-line Quality Assurance System for HDR Brachytherapy (고선량률 근접 방사선 치료를 위한 실시간 온-라인 정도 관리(QA) 시스템 개발)

  • Lee Su Jin;Lee Re Na;Yi Byang Yang;Lim Sang Waak;Choi Jin Ho
    • Progress in Medical Physics
    • /
    • 제15권3호
    • /
    • pp.156-160
    • /
    • 2004
  • An essential quality assurance (QA) procedure in high dose rate (HDR) remote after-loading brachytherapy is that of the verification of the Ir-192 HDR source positioning accuracy. A number of methods using mechanical rulers or autoradiograph and video cameras have been reported to check the positional error of the Ir-192 source. In this study, the feasibility of a CMOS (Complementary Metal Oxide Semiconductor) PC camera, with a fluorescent screen, was investigated. The agreement between the planned and measured dwell position was better than 1 mm and dwell times better than 0.4 sec. Our results indicate that the CMOS PC camera system could be used as a QA tool for the on-line determination of the source position and dwell time.

  • PDF

A Study on The Shape of a Canal Prepared With 'TWO-FILE' Technique (Two-File' 방식에 의한 근관 형성시 근관의 형태에 관한 연구)

  • Han-Soo Park;Seung-Ho Baek
    • Restorative Dentistry and Endodontics
    • /
    • 제26권6호
    • /
    • pp.507-511
    • /
    • 2001
  • 이 연구의 목적은 'Two File' 방식에 의한 근관형성시 근관의 형태변화 및 전이정도를 분석하고 이를 기존의 근관형성방법과 비교하고자 하는 것이다. 만곡된 근관을 가진 투명한 레진블럭 상에서 step back방식, crown down방식 및 'Two File' 방식으로 근관형성을 시행하고 이를 똑같은 위치가 재현가능한 고정틀에 위치시킨 후 사진의 이중노출 기법을 이용하여 근관형성 전후의 근관의 형태변화 및 전이정도를 분석 한 결과 다음과 같은 결과를 얻었다. 1. step back방식의 경우 형성된 근관이 taper하지 못하고 불규칙한 형태를 보였으며 근관의 전이정도도 다른 두 가지 엔진구동 방식에 의한 경우에 비해 유의하게 컸다(p<0.05) 2. crown down방식의 경우 형성된 근관이 taper한 형태를 보였고, 근관의 전이 정도도 step back방식에 의한 경우보다 유의하게 작았다(p<0.05). 3. 'Two File' 방식의 경우 형성된 근관이 taper한 형태를 보였으며 근관의 전이정도도 step back방식에 의한 경우보다 유의하게 작았으나 crown down방식에 의한 경우와 유의할 만한 차이는 없었다(p<0.05).

  • PDF

Development of Biotelemetry Method by Combining the SSBL Method and the Pinger Synchronizing Method (2) - Evaluation for Precision of System - (SSBL 방식과 핑거동기 방식을 조합한 바이오텔레메터리 방식의 개발 (2) -시스템의 정도 평가 -)

  • 박주삼;고탁창언
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • 제39권4호
    • /
    • pp.318-325
    • /
    • 2003
  • The new biotelemetry method and system that the installation and the treatment of equipment is convenient and the instantaneously detailed position of the fish attached the pinger is able to track comparatively easily had been developed, an availabilities of it were verified in water tank by using hydrophone and pinger. First of all, the receiving system for biotelemetry was calibrated so as to measure tracking of high precision or wide detection range. In the next place, the precision at narrow and wide beam array of receiving system by using hydrophone was investigated and the actual position was compared with measured hydrophone position. The mean standard deviations of the position by narrow beam array of receiving system were 6.4em in phase beam of fore-aft pair and 6.3em in starboard-port pair, and the wide beam array were 24em and 23em respectively. The precision of distance, position, and velocity at narrow beam array of receiving system by using pinger were investigated and the actual values were compared with measured values. The distance from receiving system to pinger was measured by the pinger synchronizing method, angle of direction of pinger was detected by the super short base line (SSBL) method. The three dimensional position of pinger to the receiving system was measured by combining of two kinds of methods (SPB method), the velocity of pinger was obtained with a differential of the three dimensional positions. The mean standard deviations of the distance by pinger synchronizing method in narrow beam array of receiving system was 1. 8 em, that of the position by SPB method was 7.7cm.

Design and Implementation of the Localization System Using Distance Identification Code in Wireless Sensor Network (무선 센서네트워크에서 거리 식별코드를 이용한 위치인식시스템 설계 및 구현)

  • Choi, Chang-Yong;Lee, Dong-Myung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제34권8A호
    • /
    • pp.575-582
    • /
    • 2009
  • The localization algorithm(LAtu) using the IDentification Code($C_{ID}$) is suggested in RSS(Received Signal Strength) based Wireless Sensor Network(WSN), and the localization system using the suggested algorithm is designed and implemented in this paper. In addition to this, the performance of ranging correction quality and localization error of the localization system(System(LAtu)) that is developed using the LAtu is analyzed and compared with that of the localization system(System(LAieee)) using the channel model of IEEE 802.15.4 standard(LAieee) by the actual experimentation. From the experimentation, the ranging correction quality is analyzed that the LAtu is highly better than the channel model of LAieee about 34% under the distance between the moving module and the beacon module($D_{MM-BM}$) is 2m, and is also a few better than that of the LAieee about average 5% under the $D_{MM-BM}$ is above 5m. The localization error quality of the System(LAtu) is lower than that of the System(LAieee)) about 1cm under the lecture room and 4cm in the large lecture room.