• Title/Summary/Keyword: 위치분석

Search Result 15,167, Processing Time 0.05 seconds

Comparison of fatigue fracture strength by fixture diameter of mini implants (미니 임플란트 직경에 따른 피로파절강도의 비교 연구)

  • Heo, Yu-Ri;Son, Mee-Kyoung;Kim, Hee-Jung;Choe, Han-Cheol;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.156-161
    • /
    • 2012
  • Purpose: This study was conducted to obtain difference in fracture strength according to the diameter of one-body O-ring-type of mini implant fixture, to determine the resistance of mini implant to masticatory pressure, and to examine whether overdenture using O-ring type mini implant is clinically usable to maxillary and mandibular edentulous patients. Materials and methods: For this study, 13 mm long one body O-ring-type mini implants of different diameters (2.0 mm, 2.5 mm and 3.0 mm) (Dentis, Daegu, Korea) were prepared, 5 for each diameter. The sample was placed at $30^{\circ}$ from the horizontal surface on the universal testing machine, and off-axis loading was applied until permanent deformation occurred and the load was taken as maximum compressive strength. The mean value of the 5 samples was calculated, and the compressive strength of implant fixture was compared according to diameter. In addition, we prepared 3 samples for each diameter, and applied loading equal to 80%, 60% and 40% of the compressive strength until fracture occurred. Then, we measured the cycle number on fracture and analyzed fatigue fracture for each diameter. Additionally, we measured the cycle number on fracture that occurred when a load of 43 N, which is the average masticatory force of complete denture, was applied. The difference on compressive strength between each group was tested statistically using one-way ANOVA test. Results: Compressive strength according to the diameter of mini implant was $101.5{\pm}14.6N$, $149{\pm}6.1N$ and $276.0{\pm}13.4N$, respectively, for diameters 2.0 mm, 2.5 mm and 3.0 mm. In the results of fatigue fracture test at 43 N, fracture did not occur until $2{\times}10^6$ cycles at diameter 2.0 mm, and until $5{\times}10^6$ cycles at 2.5 mm and 3.0 mm. Conclusion: Compressive strength increased significantly with increasing diameter of mini implant. In the results of fatigue fracture test conducted under the average masticatory force of complete denture, fracture did not occur at any of the three diameters. All of the three diameters are usable for supporting overdenture in maxillary and mandibular edentulous patients, but considering that the highest masticatory force of complete denture is 157 N, caution should be used in case diameter 2.0 mm or 2.5 mm is used.

The Variation of Leaf Form of Natural Populations of Quercus variabilis in Korea (굴참나무 천연집단(天然集團)의 엽형(葉型) 변이(變異))

  • Song, Jeong-Ho;Park, Mun-Han;Moon, Heung-Kyu;Han, Sang-Urk;Yi, Jae-Seon
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.5
    • /
    • pp.666-676
    • /
    • 2000
  • For the study of morphological variation of Q. variabilis natural population in Korea, 19 populations were selected through the country in considering latitude, longitude, and geographical characters. Thirty trees were randomly selected from each population and 60 mature leaves were sampled from each tree. Four characters (leaf blade length, maximum blade width, petiole length, and vein number) were measured, and their ratios (the ratio of blade length to maximum blade width, the ratio of blade length to petiole length, the ratio of petiole length to vein number, upper 1/3 blade width to maximum blade width, and upper 1/3 blade width to lower 1/3 blade width) were calculated. 1. Analysis of variance for all leaf characters were significantly different among populations and among individuals within population. Contributions of variance among individuals within population in all the characters were higher than those among populations. Therefore, selection of plus trees may be preferable to desirable populations for breeding program of Q. variabilis. 2. Among principal component analysis for leaf characters, primary 2 principal components appeared to be major variables for leaf form of Q. variabilis because of the loading contribution of 80.5%. The first contribution component was petiole length/vein number and petiole length ; the second one was upper 1/3 blade width/maximum blade width, upper blade width/lower 1/3 blade width and vein number, respectively. 3. Latitude was positively correlated with blade length/maximum blade width and blade length/petiole length, but negatively correlated with petiole length/vein number, upper 1/3 blade width/maximum blade width, upper 1/3 blade width/lower 1/3 blade width, petiole length, and vein number. But, for longitude and altitude the former two traits and the later five traits exhibited the negative and positive correlation, respectively. 4. Cluster analysis using complete linkage method for leaf characters showed two groups to Euclidean distance 1.6. They were group I of population 1. 4, 5, and 13 and group II of population 2, 3, 6, 7, 8, 9, 10, 11, 12, 14, 15, 16, 17, 18, and 19. However, group II was divided again to Euclidean distance 1.3, that is a group including population 3, 7, 10, 14, 15, and 17(group II-1) and the other group comprising population 2, 6, 8, 9, 11, 12, 16, 18, and 19(group II-2). This cluster could be mainly observed due to difference among population in aspect (group I : NE, group II-1 : SE, and group II-2 : SW).

  • PDF

Analysis of Growth Characteristics and Aboveground Carbon Storage for Zelkova serrata Artificial Forests in Gwangneung Experimental Forest (광릉시험림 내 느티나무(Zelkova serrata) 인공림의 생장특성 및 지상부 탄소저장량 분석)

  • Kim, Hyun-Seop;Bae, Sang-Won;Lee, Sang-Tae;Hwang, Jae-Hong
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.1
    • /
    • pp.144-152
    • /
    • 2010
  • This study was conducted to analyze the growth characteristics and aboveground carbon storage for old growth Zelkova serrata artificial forests (site1: age class IX, site2: age class VIII) in Gwangneung Experimental Forest. The trees were classified by crown classes for analyzing forest stand structure. The growth characteristics were analized through ringwidth increment by crown classes and stem analysis of dominant trees. There were a wide range of DBH (site1: 8~62 cm, site2: 14~40 cm) and height (site1: 8~26 m, site2: 12~26 m) distributions and revealed different growth characteristics by crown classes in both sites. The mean annual increment (MAI) of ringwidth for the last 5 years of dominant trees for site1 (3.3 mm) was higher than MAI of ringwidth of total growth period (2.3 mm) and MAI of ringwidth for the last 5 years of dominant trees for site2 (2.2 mm) was equal to MAI of ringwidth of total growth period (2.2 mm). Also, the growth increment of ringwidth by crown classes had significant differences between dominant tree and the others crown classes (p<0.01) in both sites. As a results of stem analysis of dominant trees in both sites, there were similar to their volume between site1 (1.106 $m^3$) and site2 (1.035 $m^3$). In spite of old age, the annual increment of volume has been increasing steadily until recent year. Meanwhile, total aboveground carbon storage of site1 (65.6 Mg C $ha^{-1}$) was higher than that of site2 (56.1 Mg C $ha^{-1}$). The proportion of dominant and co-dominant trees to total aboveground carbon storage was more than 90% and the greatest individual aboveground carbon storage by crown classes was dominant tree in all both sites. However, individual aboveground carbon storage of dominant tree in site1 had 0.054 Mg C $tree^{-1}$ more than site2 owing to the differences from average DBH of dominant trees by sites. We think that these results will contribute to the forest practice for Zelkova serrata artificial forests as a basic information.

Treatment and Survial Rate of Malignant Peripheral Nerve Sheath Tumors (악성 말초신경막 종양의 치료와 생존율)

  • Lee, Jong-Seok;Jeon, Dae-Geun;Cho, Wan-Hyung;Lee, Soo-Yong;Oh, Jung-Moon;Kim, Jin-Wook
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.2
    • /
    • pp.131-138
    • /
    • 2003
  • Purpose: We analyzed our malignant peripheral nerve sheath tumor (MPNST) cases to find out their oncologic results following by each treatment modalities. Materials and Methods: Thirty four patients with MPNST were registered in Korea Cancer Center Hospital from Feb. 1986 to Nov. 1996. Seventeen cases were male and 17, female. Average age was 41 years (range 18 to 74). Location of the tumor was as follows; 17 in lower extremity, 11 upper extremity, 4 trunk, and 2 retroperitoneum. Following the AJC classification, stage IA were 2 cases, stage IIA 2, stage IIB 6, stage III 16 and stage IV 8. Twenty six patients took operations and adjuvant chemotherapy and/or radiation therapy, 3 operation only and 3 adjuvant chemotherapy or radiation therapy. Average follow up period was 33.5 months (5.6 to 146.1). Kaplan-Meiyer method was done for survival curve, and log rank test for comparison analysis. Results: Fourteen cases were continuous disease free, 2 no evidence of disease, 2 alive with disease and 14 dead of disease states at final follow up. Actual 5-year and 10-year survival rates were 53.5%, 35.7%. Local recurrence rate after operation was 24.1%. 5-year survival rates of stage I/II/III were 100/85.7/55.9% and 2-year survival rate of stage IV was 14.3% (p=0.04). In 21 cases operated with stage II-III, wide margin (15cases) had 76.0% 5-year survival rate, and marginal or intralesional marigin (6cases) had 40.0%. The actual 5-year survival rate of the group which were done 4 or more cycles chemotherapy (8cases) was 71.4% and the actual 3-year survival rate less than 4cycles chemotherapy (6cases) was 83.3% (p=0.96). In 19 cases operated with stage II-III and which had no radiotherapy, marginal or intralesional margin (5cases) had 3 cases of local recurrences (60.0%), though wide margin (14cases) had 4 cases recurrences (28.6%). There was no local recurrence in 8cases which had pre-or post-operative radiotherapy. Conclusions: Surgical margin is an important factor in local recurrence. Resection margin has a tendency to influence the survival despite insufficient statistical significance. Conventional chemotherapy has no defnite statistical sigficance in the effect on local control and survival. Preoperative and postoperative radiotherapy has some positive effect on local control.

  • PDF

The Verification of Computer Simulation of Nitinol Wire Stent Using Finite Element Analysis (유한요소법을 이용한 나이티놀 와이어 스텐트의 전산모사 실험 데이터 검증)

  • Kim, Jin-Young;Jung, Won-Gyun;Jeon, Dong-Min;Shin, Il-Gyun;Kim, Han-Ki;Shin, Dong-Oh;Kim, Sang-Ho;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.139-144
    • /
    • 2009
  • Recently, the mathematical analysis of stent simulation has been improved, with the help of development of various tool which measure mechanical property and location of stent in artery. The most crucial part of the stent modeling is how to design ideal stent and to evaluate the interaction between stent and artery. While there has been great deal of researches on the evaluation of the expansion, stress distribution, deformation of the stent in terms of the various parameters, few verification through computer simulation has been performed about deformation and stress distribution of the stent. In this study, we have produced the corresponding results between experimental test using Universal Testing Machine and computer simulation for the ideal model of stent. Also, we have analyzed and compared stress distribution of stent in the cases of that with membrane and that without membrane. The results of this study would provide minimum change of plan and good quality for ideal stent replacing damaged artery through the analysis using computer simulation in the early stage of stent design.

  • PDF

Evaluation of the Accuracy for Respiratory-gated RapidArc (RapidArc를 이용한 호흡연동 회전세기조절방사선치료 할 때 전달선량의 정확성 평가)

  • Sung, Jiwon;Yoon, Myonggeun;Chung, Weon Kuu;Bae, Sun Hyun;Shin, Dong Oh;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.127-132
    • /
    • 2013
  • The position of the internal organs can change continually and periodically inside the body due to the respiration. To reduce the respiration induced uncertainty of dose localization, one can use a respiratory gated radiotherapy where a radiation beam is exposed during the specific time of period. The main disadvantage of this method is that it usually requests a long treatment time, the massive effort during the treatment and the limitation of the patient selection. In this sense, the combination of the real-time position management (RPM) system and the volumetric intensity modulated radiotherapy (RapidArc) is promising since it provides a short treatment time compared with the conventional respiratory gated treatments. In this study, we evaluated the accuracy of the respiratory gated RapidArc treatment. Total sic patient cases were used for this study and each case was planned by RapidArc technique using varian ECLIPSE v8.6 planning machine. For the Quality Assurance (QA), a MatriXX detector and I'mRT software were used. The results show that more than 97% of area gives the gamma value less than one with 3% dose and 3 mm distance to agreement condition, which indicates the measured dose is well matched with the treatment plan's dose distribution for the gated RapidArc treatment cases.

Comparison of Heating Characteristics of Electric Heating Element Heater and Oil Hot Air Heater in Single Span Greenhouses (전기발열체 난방기 및 유류온풍 난방기의 단동온실 난방 특성 비교)

  • Kwon, Jin Kyung;Kim, Seung Hee;Shin, Young An;Lee, Jae Han;Park, Kyeong Sub;Kang, Youn Koo
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.324-332
    • /
    • 2017
  • The comparative experiments were conducted for single span greenhouses where cucumbers were cultivated to analyze the effect of heating between a carbon fiber electric heating element heater and an oil hot air heater in terms of the inside climate, energy consumption and plant growth. In order to analyze the effect of heating capacity, 6, 9, and 16 kW of electric powers were supplied to the electric heating element for same setting temperature of 15?. As a result, as the heating capacity increased, the number of ON-OFF cycles of the electric heating element and the temperature inside the greenhouse increased proportionally. In the comparison of two heaters, it was shown that the temperature and relative humidity distributions of the electric heating element installed greenhouse was much uniform than those of the oil hot air heater installed greenhouse. The heating energy consumptions during the heating period of 79 days were 867L for the oil hot air heater and 8,959 kWh for the electric heating element heater, and the heating costs were 607 and 403 thousand won respectively. In the electric heating element installed greenhouse, the cucumber growth was slightly better and the yield was 4.3% higher than those of the oil hot air heater installed greenhouse, but there were no statically significant difference in the cucumber growth and yield between greenhouses.

Analysis of Air Temperature and Humidity Distributions and Energy Consumptions according to Use of Air Circulation Fans in a Single-span Greenhouse (단동온실 내 공기순환팬 사용에 따른 온습도 및 에너지소비량 비교 분석)

  • Lee, Tae Seok;Kang, Geum Choon;Kim, Hyung Kweon;Moon, Jong Pil;Oh, Sung Sik;Kwon, Jin Kyung
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.276-282
    • /
    • 2017
  • The aim of this study was to compare and analyze air temperature and humidity distribution and energy consumptions according to using air circulation fans in single-span greenhouses. The greenhouses located in Cheongnam-myeon, Cheongyang-gun, Chungcheongnam-do, Korea. There were cherry tomatoes in the greenhouses and the size of greenhouses was as follows;ridge height : 3.2 m, wide : 6 m, length : 95 m. The heating system was composed of a hot-water boiler and 6 FCUs(Fan Coil Unit)-4 FCUs were on bottom with duct and 2 FCUs were installed at 2.0 m. A total of 18 air circulation fans(impeller's diameter : 230 mm) were bilaterally arranged in 2 rows in the experimental greenhouse. The sensors for measuring air temperature and humidity were located at a quarter and three quarters of a length. The height of sensors were 0.8 m, 1.8 m. To calculate energy consumption in greenhouses, water temperature at inlet and outlet in a water pump, volume of water were measured. Form February 3rd to March 23th, temperature, humidity and energy consumptions were measured during heating time(6pm~7am). In a greenhouse without fans, the average differences of temperature and humidity were $0.75^{\circ}C$, 2.31%, respectively. The operation of fans showed their differences to $0.42^{\circ}C$, 1.8%. The standard deviation of temperature and humidity between measuring points in the greenhouse with fans was lower than the greenhouse without fans. Total energy consumptions in a greenhouse without fans were 4,673 kWh. In the greenhouse with fans, the total energy consumptions were 4,009 kWh. The energy consumptions in a greenhouse with fans 14.2% were less than the greenhouse without fans. Therefore, air circulation makes temperature and humidity uniform and saves energy consumptions for heating.

MR Findings of Hypoxic Brain Damage: Relation to Time Elapse and Prognosis of Patients (저산소성 뇌손상의 자기공명영상 소견: 유병기간 및 예후와의 연관성)

  • Suh, Kyung-Jin;Kang, Chae-Hoon;Yoo, Dong-Soo;Kim, Sang-Joon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.1
    • /
    • pp.8-15
    • /
    • 2006
  • Purpose : To describe MR imaging features of hypoxic brain damage in relation to time elapse and prognosis of patients. Materials and methods : We reviewed 19 MR studies of 18 patients with hypoxic brain damage. MR imaging studies were performed between 1 to 20 days after the hypoxic insults (mean 8.6 days). MR images were analyzed with regard to the locations of abnormal signal intensities, the presence of brain edema. And imaging findings were correlated with the time elapse after the insults and the prognosis of patients. Results : On 19 cases of MR studies, abnormal high intensities on T2-weighted images were found in the basal ganglia (15, 78.9%), cerebral cortex (13, 68.4%), white matter (9, 47.4%), thalamus (6, 31.6%), cerebellum (4, 21.1%) and brainstem (1, 5.3%), respectively. Cerebral cortical involvement was typically bilateral and diffuse, but sometimes limited to the parieto-occipital area. The brainstem and cerebellar involvement was rare and in all cases, cerebral cortical lesions accompanied. Most of the white matter lesions were accompanied with cortical and deep gray matter lesions and found in subacute period(>6 days). The cortical high signal intensity lesions on T1-weighted image were found mostly in subacute stage, but in some cases involvement was also found in acute stage ($\leq$ 6 days). The cortical edema is found on 11 cases in acute and subacute stages. In cases of recovered consciousness, cortical involvement and edema on MR were rare. Conclusion : MR findings of hypoxic brain damage were various, but diffuse bilateral involvement of cortex and/or deep gray matter was found in most of the cases. White matter involvement was rarely found in acute stage and usually found in subacute stage. In cases of good pronosis, cortical involvement and edema were rare.

  • PDF

Usefulness of Low Dose Oral Contrast Media in $^{18}F-FDG$ PET/CT ($^{18}F-FDG$ PET/CT에서 저용량 경구용 조영제의 유용성)

  • An Young-Sil;Yoon Joon-Kee;Hong Seon Pyo;Joh Chul-Woo;Yoon Seok-Nam
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.5
    • /
    • pp.257-262
    • /
    • 2006
  • Purpose: The standard protocol using large volume of oral contrast media may cause gastrointestinal discomfort and contrast-related artifacts in PET/CT. The aim of this study was to evaluate the usefulness of low dose oral contrast in $^{18}F-FDG$ PET/CT. Materials and Methods: We retrospectively reviewed the whole-body PET/CT images in a total of 435 patients. About 200 ml of oval contrast agent (barium sulfate) was administered immediately before injection of $^{18}F-FDG$. The FDG uptake of intestines was analyzed by visual and semi- quantitative method on transaxial, coronal and saggital planes. Results: Seventy (16%, 113 sites) of 435 images showed high FDG uptake (peak SUV > 4); 50 (74%, 84 sites) with diffuse and 20 (15%, 29 sites) with focal uptake. The most commonly delivered site of oral contrast media was small bowel (n=27, 39%). On PET/CT images, FDG uptake coexisted with oral contrast media in 26 patients (54%, 38 sites) with diffuse pattern and 9 (45%, 9 sites) with focal pattern, and by sites, those were 38 (45%) and 9 (31%), respectively. In small bowel regions, the proportion of coexistence reached as high as 61% (29/47 sites). A visual analysis of available non-attenuation corrected PET images of 27 matched regions revealed no contrast-related artifact. Conclusion: We concluded that the application of low dose contrast media could be helpful in the evaluation of abdominal uptake in the FDG PET/CT image.