• Title/Summary/Keyword: 위치변위

Search Result 836, Processing Time 0.022 seconds

Determination of Optimal Locations for Measuring Displacements to Adjust Cable Tension Forces of Cable-Stayed Bridges (사장교 시공 중 케이블 장력 보정을 위한 최적 변위계측 위치 결정)

  • Shin, Soobong;Lee, Jung-Yong;Kim, Jae-Cheon;Jung, Kil-Je
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.129-136
    • /
    • 2009
  • The paper presents an algorithm of selecting optimal locations for measuring displacements(OLD) to adjust cable tension forces during the construction of cable-stayed bridges. The rank for optimal locations can be determined from the effective independence distribution vectors(EIDV) that are computed from the Fisher Information Matrices(FIM) formulated with the displacement sensitivities. To examine the efficiency and reliability of the proposed algorithm for determining OLD, a simulation study on a cable-stayed bridge has been carried out. The results using FIM formulated with displacements are compared with those using FIM with displacement sensitivities through the simulation study. The effects of measurement noise and error in cable length on the adjustment of cable tension forces are evaluated statistically by applying the Monte Carlo scheme.

The Element Stiffness Ratio and Outrigger Locations for Optimum Design Model in Preliminary Design of Outrigger Structures by G.A. (G.A.를 이용한 아웃리거 시스템의 초기설계단계에서 부재 강성비 및 아웃리거 위치 최적화에 관한 연구)

  • Lee, Eun-Seok;Choi, Se-Woon;Park, Hyo-Seon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.721-724
    • /
    • 2010
  • 아웃리거 시스템은 고층건물의 구조설계 시에 횡변위를 제어하기 위해 사용되는 가장 효율적이고 널리 사용되는 구조시스템 중 하나이다. 아웃리거는 설치 위치의 최적성에 따라 횡변위 제어효과에 상당한 차이가 있으며, 1970년대 이후부터 아웃리거의 최적위치에 관한 연구가 활발히 진행되어 왔다. 아웃리거의 최적위치는 구조물의 전단벽, 아웃리거, 외각기둥의 요소간 강성비에 따라 변하는 값이므로, 아웃리거 시스템의 횡변위는 요소간 강성비와 아웃리거 위치 모두에 의해 영향을 받는다. 따라서 초기구조설계 단계에서 아웃리거의 위치에 대한 결정과, 각 요소간 강성비의 선택은, 전체 구조 시스템의 효율성에 상당한 영향을 미치게 된다. 하지만 아웃리거 시스템의 최적 효율을 보장하면서, 구조물의 초기 설계 시에 참고할 수 있는, 아웃리거의 최적위치와 요소간 강성비에 대한 연구는 미흡한 실정이다. 따라서 본 연구에서는 GA(genetic algorithm)을 이용하여 초기 설계 시에 참고할 수 있는 고층건물의 횡변위를 최소로 하는, 아웃리거의 최적 위치 및 요소간 강성비에 대한 연구를 진행하고자 한다. 이를 위해 시공된 예제 건물에 적용을 통해 그 효과를 검증해 본다.

  • PDF

A Development of Displacement Monitoring System by GPS (GPS에 의한 변위 모니터링시스템 개발)

  • 최병길;문일용;이수영;김성표
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2001.10a
    • /
    • pp.71-82
    • /
    • 2001
  • 인공위성을 이용한 범 지구 위치결정시스템인 GPS(Global Positioning System)는 수 밀리의 정밀도로 정적, 동적 위치측정이 가능한 시스템으로 교량, 건축물, 댐 등 각종 구조물의 미세한 변위를 측정하는데 이용되고 있다. 최근 국내에서도 대형구조물의 변위 측정에 GPS를 활용하려는 시도가 부분적으로 이루어지고 있으나 초보적인 단계이며 체계적인 연구가 이루어지지 못하고 있는 실정이다. 본 연구에서는 RTK(Real Time Kinematic) GPS로 구조물의 변위를 실시간 측정하고 모니터링 할 수 있는 시스템을 개발하였다. 먼저 예비실험으로 반송파의 차분에 의해서 증폭되는 수신기의 측정잡음 오차, 다중경로 오차, GDOP(Geometric Dilution of Precision)가 RTK GPS의 위치정확도에 미치는 영향을 분석하였다. 그리고, RTK GPS를 이용하여 마포대교를 관측한 결과, 수 센티미터 정도 발생하는 구조물의 변위를 3차원으로 정밀 관측할 수 있었으며, 본 연구에서 개발한 모니터링프로그램을 이용하여 구조물의 거동을 실시간으로 모니터링 할 수 있었다.

  • PDF

A study on the selection of sensing locations for a high-rise building using displacement participation factor and strain energy density (변위기여도 및 변형에너지밀도를 활용한 고층 건물의 센싱 위치 선정에 관한 연구)

  • Lee, Hong-Min;Park, Sung-Woo;Park, Hyo-Seon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.217-220
    • /
    • 2009
  • 고층 건물에 대한 구조 안전성 모니터링은 건물 특성상 계측 대상 부재가 많고 하중과 구조반응의 관계가 복잡하기 때문에 센싱 위치 선정의 어려움으로 그 적용에 한계가 있다. 본 논문에서는 고층 건물의 구조 건전도 모니터링을 위한 구조반응 계측위치를 선정하기 위해서 에너지 이론에 근거한 부재의 변위기여도 및 변형에너지밀도 개념을 도입하였다. 보, 기둥, 코어 전단벽, 그리고 아웃리거로 구성된 고층 건물을 대상으로 풍하중에 대한 부재 종류별 부재의 변위기여도 및 변형에너지밀도를 확인하고 전체 구조물의 거동과의 관계를 분석하여 고층 건물의 구조 건전도 모니터링을 위한 센싱 위치를 예상해보았다.

  • PDF

Lateral Displacement Analysis of Concrete Electric Pole Foundation Grounds (배전용 콘크리트전주 기초지반의 횡방향변위 분석)

  • Ahn, Tae-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.42-49
    • /
    • 2009
  • The effects of various forces acting on concrete pole are analyzed using finite element method how the forces affect on ground displacement. The soil types, wind load location of anchor block embedded depth of pole, and distance between poles are varied to find out effects on lateral displacement. Anchor block is effective when it is located at 1/4 of embedded depth The displacement is decreases as elastic modulus increases. Concrete reinforcement for loosened ground is necessary for double poles because double poles cause large excavation. When embedded depth ratio decrease, lateral displacement increase as closer to ground surface. Large embedded depth is effective to reduce lateral displacement, and the distance between poles is not much large factor.

Forces and Displacements of Outrigger-Braced Structures with a Pair of Coupled Cores (병렬코아를 갖는 아웃리거구조물의 응력과 변위)

  • 정동조;이태희
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.3
    • /
    • pp.291-299
    • /
    • 2003
  • Based on the continuum approach, an investigation is made to get the forces and displacements of laterally loaded outrigger braced structures with a pair of coupled cores, and to show the effect of stiffening outriggers on the behavior of the structure. From the condition that the rotation of the core at the outrigger level is matched with the rotation of the corresponding outrigger, the outrigger restraining moment is derived analytically. From this, the core moment diagram, the column axial forces, and the horizontal displacements of the structure may be determined. Comparisons with the results by the program MIDAS-GEN for the structural models, have shown that this analysis can give reasonably accurate results for outrigger-braced structures with a pair of coupled cores. And a lateral displacement at the top of the structure is influenced by the outrigger location than the core location. Although the formulae are accurate only for idealized outrigger braced structures, they have a useful practical purpose in providing a guide to the behavior, and for making approximate estimates of the forces and displacements, in practical outrigger braced structures with a pair of coupled cores.

Vision-Based Displacement Measurement System Operable at Arbitrary Positions (임의의 위치에서 사용 가능한 영상 기반 변위 계측 시스템)

  • Lee, Jun-Hwa;Cho, Soo-Jin;Sim, Sung-Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.123-130
    • /
    • 2014
  • In this study, a vision-based displacement measurement system is developed to accurately measure the displacement of a structure with locating the camera at arbitrary position. The previous vision-based system brings error when the optical axis of a camera has an angle with the measured structure, which limits the applicability at large structures. The developed system measures displacement by processing the images of a target plate that is attached on the measured position of a structure. To measure displacement regardless of the angle between the optical axis of the camera and the target plate, planar homography is employed to match two planes in image and world coordinate systems. To validate the performance of the present system, a laboratory test is carried out using a small 2-story shear building model. The result shows that the present system measures accurate displacement of the structure even with a camera significantly angled with the target plate.

Morphologic and positional assessment of temporomandibular joint disk in facial asymmetric patients by magnetic resonance imaging (자기 공명 영상을 이용한 안면비대칭환자의 측두하악관절원반의 형태와 위치에 관한 연구)

  • Zou, Bingshuang;Kim, Tae-Woo;Choi, Soon-Chul
    • The korean journal of orthodontics
    • /
    • v.35 no.5 s.112
    • /
    • pp.398-407
    • /
    • 2005
  • The present study was conducted to examine the morphometrics and function of the disk on both sides among patients with facial asymmetry (FA) and to elucidate plausible correlations between internal derangement (ID) and FA. The sample was composed of 10 males and 27 females with FA. The disk status of all subjects was evaluated by bilateral high resolution magnetic resonance scans in the sagittal (closed and open) and coronal (closed) planes. Five types of disk displacement were identified accordingly. The disk function was diagnosed as normal disk function, disk displacement with reduction, and disk displacement without reduction. The disk shape on sagittal MRI in closed position was classified as bi-concave, biplanar, funnel/hemiconvex, and deformed. The disk position, translation and rotation were also measured. The difference between the shifted side and non-shifted side was analyzed by statistical analysis. Approximately $70\%$ of the patients in the present study showed unilateral or bilateral ID. It was found that anterior disk displacements (ADD), especially rotational ADD, occurred more frequently in the shifted side, while normal disk position was observed mainly in the non-shifted side (p<0.01). The disk of the shifted side showed significantly deformed configuration and inferior-anterior disk position. However, the disk of the non-deviated side showed hyper-mobility during jaw opening movement. These results demonstrate that in FA patients, the disks status of the shifted side is different from that of the non-shifted side, a phenomenon that could be correlated to facial asymmetry.

Prediction of Ground Condition Changes Ahead of Tunnel Face Using Three-Dimensional Absolute Displacement Analysis (터널 3차원 절대변위 해석기법을 이용한 막장전방지반 예측)

  • Bang, Joon-Ho;Han, Il-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.2
    • /
    • pp.101-113
    • /
    • 2006
  • Arching effect occurs around the unsupported excavation surface near to tunnel face when a tunnel is excavated in a stable rock mass. If a weak fracture zone exists in front of tunnel face, a displacement occurs between tunnel face and weak fracture zone due to stress concentration. If three-dimensional absolute coordinates (longitudinal, transverse, vertical direction) is measured at tunnel face by geodetic method, the ground change in front of the tunnel face can be predicted by analysing three-dimensional absolute displacement. The purpose of this study is to verify the analysis method of three-dimensional absolute displacement by comparing the trend of displacement ratio at crown and sidewall of tunnel and the influence line/trend line of crown settlement compared with TSP results in the same section.

  • PDF

Measurement of Tunnel 3-D Displacement using Digital Photogrammetry (디지털 영상을 이용한 터널 3차원 변위 계측)

  • Kim, Kwang-Yeom;Kim, Chang-Yong;Lee, Seung-Do;Seo, Yong-Seok;Lee, Chung-In
    • The Journal of Engineering Geology
    • /
    • v.17 no.4
    • /
    • pp.567-576
    • /
    • 2007
  • In order to assess the on-site applicability of 3D absolute displacement monitoring of tunnel using digital photogrammetry, the displacement of the optical target placed at the measurement section was investigated, as planned in the OO tunnel construction site. The targets on 3 measurement lines only were considered for each point of measurement for the reconstruction of 3D cubic model for the digital vision monitoring. For each 3D model, 3 or more images have to be obtained at each point. On the last 2 measurement lines, 6 targets (crown, left and right walls) were continuously overlapped to construct 3D models so that 6 or more apices can be shared by 2 3D models. In order to compare the measurement methods of 3D absolute displacements in tunnel excavation, i. e, total station and digital image measurement, both the digital image measurement and optical measurement were conducted for 10 times in the same work section. The time and measurement results of both methods were compared.