• Title/Summary/Keyword: 위생설비

Search Result 230, Processing Time 0.035 seconds

The Microbiological Assessment and Identification of Food Utensils and Food Service Facilities in School (학교 급식설비 및 집기류의 미생물학적 위해요소 분석)

  • Hong, Seung-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.3
    • /
    • pp.189-194
    • /
    • 2014
  • This study was conducted to evaluate microorganism contamination of food utensils and service facilities in school and to prevent hazards by food poisoning occurrence. As a result, the highest number of microorganism growth plate ($12.3{\pm}2.6$) was detected in total bacteria test plate, and also observed $10.3{\pm}3.9$ growth plates in Staphylococcus aureus test plate and $9.5{\pm}3.9$ growth plates in E. coli and coliform bacteria test plate. But we could detect to the lowest number of growth plates ($1.5{\pm}1.0$) in Vibrio test plate. We also assessed that floors were appeared to the highest microorganism contamination rate in food utensils and service facilities. Therefore, $4.5{\pm}0.6$ growth plates was detected in pre-operation floor and $4.3{\pm}1.0$ growth plates in floor. And high level of microorganism contamination also observed in tables as $3.3{\pm}1.0$ growth plates in cooking table and $3.0{\pm}0.0$ growth plates in dining table. The level of microorganism contamination of food utensils such as kitchen knife, cutting board, and food tray were lower than that in food service facilities. We analysed microorganism contamination according to purpose of use in kitchen knifes and cutting boards. The microorganism contamination rate in fish kitchen knife ($2.0{\pm}0.8$) and fish cutting board ($1.3{\pm}1.5$) were slightly higher than that of others purpose of use. As a result of microorganism identification, various strains of microorganism were contaminated in food service facilities and some strains could detected more than two times. Especially, Staphylococcus aureus was repeatedly identified in cooking table, trench, and kitchen knife. Bacillus cereus was identified in kitchen knife, and then Pseudomonas fluorescens and Pseudomonas aeruginosa were also detected in food utensils and service facilities as known to food spoilage microorganisms. Klebsiella pneumoniae was detected four times repeat, which widely distribute natural environment as normal bacterial flora but sometimes cause acute pneumonia. These results suggest that food utensils and service facilities are contaminated with not only major food poisoning microorganisms such as Staphylococcus aureus, but also food spoilage microorganisms. Taken together, strict personal hygiene control and efficient food service facilities management will be needed to enhance food safety in school feeding and to improve student health.

Purchasing Status and Supplier Performance Evaluation of School Foodservice in Chanwon, Korea (창원시 학교급식 식재료 구매 실태 및 공급업체 수행도 평가)

  • Jung, Hoi-Jung;Kim, Hyun-Ah
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.6
    • /
    • pp.861-869
    • /
    • 2012
  • This study was conducted to investigate the purchasing status and to compare supplier performance evaluations between competitive bidding and negotiated contracts in school foodservice in Changwon, Korea. A total of 190 questionnaires were distributed and 167 (return rate 87.9%) were collected from June 29 to September 28, 2010, and then a total of 151 (analysis rate 79.5%) were used for the final analysis. First, 91.4% of food product purchases for school meals were contracted through competitive bidding, especially limited competitive bidding. It mainly consisted of agricultural products, processed food, and eco-friendly agricultural products (fruit). Second, 78.8% of schools purchased food products by negotiated contracts, while single negotiation accounted for 59.7%. Food products by negotiated contract consisted of meat, kimchi, and fish. Third, the purchase status of competitive bidding and negotiated contracts showed a significant difference in agricultural products (p<0.001), fish (p<0.001), meats (p<0.001), poultry (p<0.001), antibiotic-free poultry (p<0.001), eco-friendly grain (p<0.001), eco-friendly agricultural products (fruit) (p<0.001), eco-friendly processed food (p<0.001), processed products (p<0.001), milk (p<0.001) and general grain (p<0.001) except for kimchi. Fourth, comparative analysis of supplier performance evaluation (on a 5-point Likert scale) of school foodservice showed that price of product of competitive bidding (3.73) was significantly higher than that of negotiated contract (2.95) (p<0.001), and the overall performance level of the negotiated contract (3.85) was significantly higher than that of competitive bidding (3.61) (p<0.01). The supplier performance evaluation levels of product packaging (p<0.01), product quality at the time of delivery (p<0.001), hygiene of products (p<0.001), consistency to specification (p<0.001), swiftness of return and exchange (p<0.001), emergency delivery (p<0.001), service of delivery staff (p<0.05), and handling of complaints (p<0.001) of negotiated contracts were significantly higher than those of competitive bidding of school foodservice. In conclusion, school foodservice selected food suppliers both by adopting competitive bidding and negotiated contracts. And there was a significant difference of school foodservice supplier performance between competitive bidding and negotiated contracts in Changwon, Korea.

Analysis of Perception of School Foodservice Facilities and Utilities in Gyeongnam Area by School Nutrition Teachers (Dietitians) -Comparison of School Foodservice Facilities and Improvement of Utilities in Schools- (경남지역 영양(교)사의 급식시설 설비에 대한 인지도 분석 -학교급식시설 현대화 사업 완료 학교와 미완료 학교의 비교를 중심으로-)

  • Jeon, Young;Kim, Hyun-Ah
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.9
    • /
    • pp.1447-1456
    • /
    • 2014
  • The purpose of this study was to compare perception of school foodservice facilities and utilities in dietitians and school nutrition teachers in the Gyeongnam area between schools that improved foodservice facilities and utilities versus those who did not. From July 23 to Aug 31, 2012, 391 questionnaires were distributed, and 289 questionnaires were obtained. A total of 275 questionnaires were used for the final analysis, excluding improper ones. The results of this study were as follows. First, among 275 schools, 90 schools (32.7%) improved school foodservice facilities and utilities while 175 schools (67.3%) did not. Second, schools with improved facilities had a more well-equipped receiving room (P<0.01), preparation room (P<0.001), dishwashing room (P<0.001), storage room for supplies (P<0.001), rest-room for school foodservice employees (P<0.05), locker room (P<0.01), shower room (P<0.001), laundry room (P<0.001), boiler room (P<0.05), and room for serving cart (P<0.05) than schools with no improvement. Third, total perception score of school foodservice facilities area from schools with improved facilities (1.71) was significantly higher than that (1.60) of school without improvement (P<0.001). Fourth, total satisfaction (3.32) of school foodservice facilities and utilities in school with improved facilities was significantly higher than that (2.62) of schools without improvement (P<0.01). Fifth, schools with improved facilities had a better equipped of floor (P<0.05), entrance (P<0.001), drain (P<0.001), water supply (P<0.01), lighting (P<0.001), hand washing (P<0.001), foodservice management room (P<0.001), locker room (P<0.001), rest-room and shower room (P<0.001), and preparation room (P<0.001) than schools without improvement. However, there was no significant difference in terms of walls and ceilings, windows, ventilation, and storage. In conclusion, school foodservice facilities and utilities improvement should conducted as soon as possible.

Application, Utilization and Management of Ozone Water in Food Manufacturing (식품 가공 공정에서의 오존수 관리 동향, 사용 실태 및 활용 방안)

  • Kim, Yong-Soo;Park, In-Sook;Kim, Ae-Young;Jeon, Kyoung-Min;Seo, Yu-Mi;Choi, Sung-Hee;Lee, Young-Ja;Choi, Hyoun-Chul;Jeon, Dae-Hoon;Kim, Hyoung-Il;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.2
    • /
    • pp.98-107
    • /
    • 2008
  • The ozone has the oxidizing power which is powerful the fluorine and the antimicrobial spectrum of wide scope. Researches were carried out to use the merits that ozone has in various fields including the food industry, and many studies are also conducted nowadays for more efficient use of ozone. The ozone was permitted legally as a food additive and was practically used in the United States, Australia, Japanese etc. In November 2007, ozone water was permitted as a food additive in Korea and the interest in the use of ozone water has been on the rise in the Korea's food industry. As a olisinfectant method, ozone has many advantages. The maintenance and management expenses of ozone are lower than the installation cost at early stages and no by-products are generated after use it compared to others. Recently the demand of ozone as a olisinfectant method is increasing drastically. Although ozone water is popularly used to sterilize raw foods like fruits, vegetables and meats, the cases are still limited and were verified by the survey results. However, the use of ozone water is gradually being increased and is focused on food services. Ozone water refers to a state where ozone is dissolved into water to more conveniently use ozone. Accordingly, ozone water should be managed in regards with the amount and time of water-dissolved ozone, and the control of discharged ozone concentration is required for safe use of ozone water. The items to control mentioned above are directly related to the performance of the devices, and therefore, it is required to newly establish the performance criteria of ozone water manufacturing devices.

Dieticians' Perceived Performance Level and Obstructive Factors of HACCP System among Elementary School Food Services in Gyeongbuk Province (경북지역 초등학교 영양(교)사의 학교급식 HACCP 시스템 수행 수준 및 장애요인 인식)

  • Yang, Ji Hye;Sung, Bo Mi;Kim, Mi Hwa;Jung, Hyun Sook;Cha, Myeong Hwa;Ryu, Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.11
    • /
    • pp.1774-1784
    • /
    • 2014
  • The purpose of this study was to determine obstructive factors and performance level of the HACCP system among elementary schools in Gyeongbuk province. E-mail survey targeted 320 dieticians, and recovery rate was 74.1%. Consequently, 227 responses were analyzed. The questionnaire was composed of 58 items under four sections (general characteristics, dieticians' perceived HACCP performance level, dieticians' perceived CCP performance level, and obstructive factors of HACCP system implementation). The item with the highest rate of HACCP performance level was 'HACCP training for foodservice employees in schools ($4.02{\pm}0.70$)' while the lowest counterpart was 'implementation of HACCP team meeting, reporting, and maintenance ($2.74{\pm}0.99$)'. The performance level of the item 'HACCP training for foodservice employees in schools' was perceived as highest when the number of students eating school meals was greater than 1,101 (P<0.05). Moreover, CCP 4 ($4.44{\pm}0.53$) and CP 5 ($4.44{\pm}0.51$) showed the best performance, whereas CCP 1 showed the lowest performance level ($3.90{\pm}0.60$). Therefore, reinforcement of hygiene instruction in menu planning is perceived as necessary. CCP 1, CCP 6 (P<0.05), and CCP 3 (P<0.001) showed significant differences in performance based on the number of students eating school meals. Further, according to results regarding obstructive factors of HACCP system execution, 'general factor' was the most severe obstructive factor in the application of HACCP ($3.46{\pm}0.62$). Among the 'factors pertaining to dieticians', the item 'hardship of proper monitoring and micro-management due to overwhelming workload' was most influential ($3.46{\pm}0.96$). Furthermore, the item 'low budget allocation by educational offices ($3.90{\pm}0.88$)' was influential among the 'factors pertaining to school administrations'. In conclusion, the results of this research can help solve obstructive factors of elementary school food services and provide knowledge that is essential for the proper implementation of HACCP.

Comparison of Foodservice Management Practices in the Employee Feeding Operations of Jeonnam and Chungchong Area (전남과 충청지역 사업체 급식소의 급식관리 실태 조사 비교연구)

  • 서희영;정복미
    • Korean Journal of Community Nutrition
    • /
    • v.9 no.2
    • /
    • pp.191-203
    • /
    • 2004
  • This study was performed to compare the foodservice management practices in the employee feeding operations of Jeonnam and Chungchong area. Questionnaires were developed and mailed to 160 dietitians with management in employee foodservice of Jeonnam and Chungchong area. Completed questionnaires were received from 124 dietitians with a response rate of 77.5%. The results of this study can be summarized as follows:. Age, work experience, concurrent position and work time of dietitians were significantly higher in the Chungchong area than those in the Jeonnam area. Times of meals and amount of meals served per day in the Chungchong area were significantly higher than those in the Jeonnam area. The type of menu by foodservice operation was high non-selective menu in both areas, especially non-selective menu was high in self-operated place whereas selective menu was high in contract management. Period of cycle menu was 10-15 days in Jeonnam area, but that was 7 days in Chungchong area and so cycle menu of both areas was significantly different (p < 0.001). Most considerable factor in menu planning was preference in Jeonnam area and was cost in the Chungchong area. Food purchasing method was used mostly by automatic computerized order in the Jeonnam area whereas telephone or mail order was high in the Chungchong area.

Microbiological Hazard Analysis for HACCP System Application to Non Heat-Frozen Carrot Juice (비가열냉동 당근주스의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Lee, Ung-Soo;Kwon, Sang-Chul
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.79-84
    • /
    • 2014
  • This study has been performed for about 270 days at analyzing biologically hazardous factors in order to develop HACCP system for the non heat-frozen carrot juice. A process chart was prepared by manufacturing process of raw agricultural products of non heat-frozen carrot juice, which was contained water and packing material, storage, washing, cutting, extraction of the juice, internal packing, metal detection, external packing, storage and consignment (delivery). As a result of measuring Coliform group, Staphylococcus aureus, Salmonella spp., Bacillus cereus, Listeria Monocytogenes, Enterohemorrhagic E. coli before and after washing raw carrot, Standard plate count was $4.7{\times}10^4CFU/g$ before washing but it was $1.2{\times}10^2CFU/g$ detected after washing. As a result of testing airborne bacteria (Standard plate count, Coliform group, Yeast and Fungal) depending on each workplace, number of microorganism of in packaging room, shower room and juice extraction room was detected to be 10 CFU/Plate, 60 CFU/Plate, 20 CFU/Plate, respectively. As a result of testing palm condition of workers, as number of Standard plate count, Coliform group and Staphylococcus aureus was represented to be high as $6{\times}10^4CFU/cm^2$, $0CFU/cm^2$ and $0CFU/cm^2$, respectively, an education and training for individual sanitation control was considered to be required. As a result of inspecting surface pollution level of manufacturing facility and devices, Coliform group was not detected in all the specimen but Standard plate count was most dominantly detected in scouring kier, scouring kier tray, cooling tank, grinding extractor, storage tank and packaging machine-nozzle as $8.00{\times}10CFU/cm^2$, $3.0{\times}10CFU/cm^2$, $4.3{\times}10^2CFU/cm^2$, $7.5{\times}10^2CFU/cm^2$, $6.0{\times}10CFU/cm^2$, $8.5{\times}10^2CFU/cm^2$ respectively. As a result of analyzing above hazardous factors, processing process of ultraviolet ray sterilizing where pathogenic bacteria may be prevented, reduced or removed is required to be controlled by CCP-B (Biological) and critical level (critical control point) was set at flow speed is 4L/min. Therefore, it is considered that thorough HACCP control plan including control criteria (point) of seasoning fluid processing process, countermeasures in case of its deviation, its verification method, education/training and record control would be required.

Evaluation of Microbial Contamination in the Manufacturing Process of Non-Heated Frozen Rice Cakes (비가열 냉동떡의 제조공정에 대한 미생물 오염도 평가)

  • Yong-Sik, Yoon;Eun-In, Yang;Young-Soo, Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.6
    • /
    • pp.400-410
    • /
    • 2022
  • This study was performed to analyze the microbial contamination levels of three non-heated rice cake manufacturers in terms of seasonal manufacturing process and to investigate the effects of summertime soaking on contamination levels and temperature-controlled soaking in water on reduction in microbial levels. The total aerobic bacteria (TAB) ranged from 2.69 log CFU/g to 5.08 log CFU/g in the produce, but the microbial contamination increased sharply during soaking. The levels of TAB and coliforms during summer soaking were 7.01 and 3.96 log CFU/g, respectively, and this was significantly higher than those in other seasons. The contamination level was high in the subsequent freezing, with the TAB level (6.24 log CFU/g) exceeding the legal standard. The temperature of soaking water in summer increased from 19.1℃ to 26.8℃ after 12 h of soaking. The microbial contamination was significantly high commensurate with increased soaking time, and the TAB level in the frozen process exceeded the legal standard from 9 h of soaking. The use of ice packs to prevent the increase in temperature of the soaking water in summer resulted in maintenance of temperature at 20.1℃ for up to 12 h. The average TAB value in the freezing process was 4.42 log CFU/g after 12 h of soaking, and this is 1.77 log CFU/g lower than that before. Based on these results, it was determined that controlling the soaking time and water temperature are essential for the production of a safe unheated frozen rice cake. The safety of the HACCP system could be established by applying these preventive management standards.

The Feasibility of Natural Ventilation in Radioactive Waste Repository Using Rock Cavern Disposal Method (동굴처분 방식을 사용하는 방사성 폐기물 처분장의 자연 환기 타당성 평가)

  • Kim Jin;Kwon Sang Ki
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.3
    • /
    • pp.183-192
    • /
    • 2005
  • Natural ventilation in radioactive waste repositories is considered to be less efficient than mechanically forced ventilation for the repository working environment and hygiene & safety of the public at large, for example, controlling the exposure of airborne radioactive particulate matter. It is, however, considered to play an important role and may be fairly efficient for maintaining environmental conditions of the repository over the duration of its lifetime, for example, moisture content and radon (Rn) gas elimination in repository. This paper describes the feasibility of using natural ventilation which can be generated in the repository itself, depending on the conditions of the natural environment during the periods of repository construction and operation. Evidences from natural cave analogues, actual measurements of natural ventilation pressures in mountain traffic tunnels with vertical shafts, and calculations of airflow rates with given natural ventilation pressures indicate possible benefits from passive ventilation for the prospective Korean radioactive waste repository. Natural ventilation may provide engineers with a cost-efficient method for heat and moisture transfer, and radon (Rn) gas elimination in a radioactive waste repository. The overall thermal performance of the repository may be improved. The dry-out period may be extended, and the seepage flux likely would be decreased.

  • PDF

Case Study of Barrier Free Design for Transportation Vulnerable: Focusing on Transfer Station Complex in Seoul Station (사회적 약자를 위한 장애물 없는 생활환경 설계 사례 분석: 서울역 복합환승시설을 중심으로)

  • Chung, Sang-Woon;Rho, Jung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.333-344
    • /
    • 2017
  • This research analyzes Seoul station, a typical transfer station complex, focusing on the evaluation of its barrier free design suitable for vulnerable persons such as senior citizens. The analysis was conducted to assess its compliance with the "barrier-free" design standard for those with physical or other disabilities. This paper proposes a list of items to evaluate for transfer station complexes with a barrier-free design. The results showed that the overall connections and internal and sanitation facilities of (Seoul station/the design?)were excellent. However, because of the lack of transfer and guidance facilities, vulnerable persons felt uncomfortable when searching for information about transferring from one means of transport to another. Furthermore, there was an extremely high risk of accidents when they transferred to the bus station. Therefore, it is necessary to arrange the transfer information facilities, in order to improve their readability and visibility. Once this is done, vulnerable people will be able to use this station more safely and conveniently.