• Title/Summary/Keyword: 위상 영상

Search Result 590, Processing Time 0.025 seconds

Interferometric Image Encryption and Decryption using Binary Phase Hologram (이진 위상 홀로그램을 이용한 간섭성 영상 암호화 및 복원)

  • 김종윤;김정우
    • The Journal of the Korea Contents Association
    • /
    • v.2 no.3
    • /
    • pp.80-86
    • /
    • 2002
  • In this paper, we propose the new optical security technique using two phase holograms based on interferometer. The encoded random phase image does not have any information on the original image. Without Hewing the key mask, one cannot decode the encrypted image and regenerate the original image. And the use of two phase only images in the proposed security system leads to maximum optical efficiency (100% in theory). Also they cannot be detected by an intensity detector such as a CCD camera. Computer simulations and optical experiments show performance of the proposed methods.

  • PDF

전류주입자기공명영상기법을 이용한 은도 변화 측정에 관한 연구

  • 강현수;오석훈;이수열;조민형;우응제
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.114-114
    • /
    • 2001
  • 목적: 열적인 방법으로 시술을 할 때 발생한 생체 조직의 온도 변화는 생체조직의 전기임피던스 변화를 야기하는데 이 전기임피던스 변화가 자기공명영상의 위상에 어떠한 영향을 미치는지를 분석하고자 하였다. 대상 및 방법: 생체조직의 전기임피던스는 조직부위에 따라 다르나 온도계수가 평균적으로 -2%/$^{\circ}C$에 이를 만큼 온도에 민감한 특성을 가지고 있다. 이러한 특성을 감안하여 유한요소법을 이용하여 자기공명영상의 위상을 계산하여 보았다. 그 결과를 토대로 0.3Tesla 자기공명영상시스템으로 팬텀을 촬영하여 자기공명영상의 위상을 구하였다.

  • PDF

Optical encryption and decryption technique using virtual image in frequency domain (가상 영상을 이용한 주파수 영역에서의 광학적 암호화 및 복호화 방법)

  • 서동환;조규보;박세준;김수중;김정우;노덕수
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.255-259
    • /
    • 2003
  • In this paper, we propose an improved image encryption and decryption method using a virtual image and a joint transform correlator (JTC). The encrypted image is obtained by the Fourier transform of the product of a virtual-phase image and a random-phase image, and a Fourier transform of the decrypting key generated by the proposed phase assignment rule is used as the Fourier decrypting key. Based on the solution, the original image is reconstructed using JTC in the frequency-domain. The proposed method using a virtual image, which does not contain any information from the original image, prevents the possibility of counterfeiting by unauthorized people. And also the auto-correlation terms, which are the drawback of a JTC system, contribute to reconstructing the original image rather than to disturbing its identification. But because phase-only encryptions are sensitive to noise and scratches, phase errors can be generated in fabricating the encrypted image or the Fourier decrypting key so the errors that are responsible for degradation of the quality of the reconstructed image are analyzed and the solution is demonstrated. Computer simulations show the solution, and the proposed method is very useful for JTC architecture.

Double Encryption of Image Based on Scramble Operation and Phase-Shifting Digital Holography (스크램블 연산 및 위상 천이 디지털 홀로그래피 기반 영상 이중 암호화)

  • Kim, Cheol-Su
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.4
    • /
    • pp.13-22
    • /
    • 2018
  • In this paper, double encryption technology of image based on scramble operation and phase-shifting digital holography is proposed. For the purpose, we perform first encryption digitally using scramble operation for the to be encrypted image, and perform phase modulation to the first encrypted image. Finally, we get the secondary encryption information through the interference between the phase-shifted reference wave and phase modulated image. The decryption process proceeds in the reverse order of the encryption process. The original image is reconstructed by digitally decoding the two encrypted images through a phase shift digital holography technique that appropriately performs arithmetic processing, phase-demodulating and then using the encryption key information used in the scramble operation. The proposed cryptosystem can recover the original image only if both the key information used in the scramble operation, the distance information used in the phase shift digital holography technique, and the wavelength of the light source are known accurately.

Evaluation of difference in respiratory phase between amplitude- and phase-based four-dimensional computed tomography (위상 기반 사차원전산화단층촬영과 진폭 기반 사차원전산화단층촬영 영상에서의 위상차 평가)

  • Lee, So Hyang;Park, Soo Yeon;Kim, Jong Sik;Choi, Byung Ki;Park, Hee Chul;Jung, Sang Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.73-78
    • /
    • 2015
  • Purpose : Under the assumption of change to the amplitude based sorting, the study will use four dimensional computed tomography imaging (4DCT) arrayed using the phase based sorting to analyze the respiratory phase difference. Materials and Methods : The study analyzed the 4DCT (4-dimensional computed tomography) images of 10 liver cancer patients that were treated with respiratory gated radiotherapy from 2015 February to March. Using RPM respiratory gating (RPM 1.7.5, Varian, USA) equipment, imaging according to respiratory cycle of phase based sorting was acquired and using a treatment planning system (Pinnacle 9.2, Philips, USA) the acquired imaging according to respiratory cycle was used to measure the abdominal movement value by respiratory cycle. The measuring point was the point where the center point of the Marker Block and the body surface met in the 50% phase image and here the coordinate values Lateral, Vertical, Longitudinal (X, Y, Z) were set as reference points, and on the X, Z plane identical to the reference point, using the identical method the Y axis coordinate value of each 0%, 30%, 40%, 50%, 60%, 80% phase images were acquired to quantitatively measure the variation of distance to the Y axis. The abdominal movement value according to respiration was applied to the theoretical model that the value decreases linearly from maximum inhalation to maximum exhalation to divide the variation of my value to predict as amplitude value by respiratory cycle and conversely the variation in amplitude was recalculated with the phase variation deviation value to analyze. Results : The deviation value between expected value and actual location was the largest in the 30% phase with 0.24 cm, and standard deviation was also the largest in 30% phase with 0.13 cm. The effective value of the deviation value derived from the average of the deviation squared value of each patient appeared as minimum 0.7 cm, maximum 0.18 cm, average 0.12 cm, and standard deviation 0.4 cm. Also by dividing the actual movement distance value with the peak expiration value then converting it into %Phase, the deviation value with actual phase 16.5% in 30% phase, 10.0% and 40% phase, 10.0% and 60% phase, 15.4% and 80% phase, and overall average about 13%, and arraying based on amplitude, phase shift occurred and further it was from peak expiration the chance of deviation occurrence was increasingly measured. Conclusion : Based on the results of the study there were differences between value acquired based on theoretical model and actual value. Therefore in respiratory gated radiotherapy using external surrogates, there needs to be establishment of respiration gated radiation system that avoids the combination of two Sorting methods considering that there will be occurrence of treatment and corresponding clinical differences due to the phase difference that occur due to the Amplitude based Phase Sorting.

  • PDF

Optical Security System Using Phase Mask and Interferometer (위상 카드와 간섭계를 이용한 광학적 보안 시스템)

  • Kim, Jong-Yun;Kim, Gi-Jeong;Park, Se-Jun;Kim, Cheol-Su;Bae, Jang-Geun;Kim, Jeong-U;Kim, Su-Jung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.1
    • /
    • pp.37-43
    • /
    • 2001
  • In this paper, we propose a new optical security technique using two phase masks based on interferometer. A binary random phase image is used as a reference image and the encrypted image is generated according to the phase difference between the reference image and the original image. If there is no phase difference of a same pixel position in two phase masks, interference intensity of the pixel has minimum value and if phase difference of a same pixel position in two phase masks is $\pi$, its interference intensity has maximum value. We can decrypt the original image by putting two phase masks on each of the two optical paths of the Mach-Zehnder interferometer. Computer simulation and the optical experiments show a good performance of the proposed optical security system.

  • PDF

SAR Interferometry Phase Unwrapping 비교 분석: Branch cut, Minimum discontinuity 및 Minimum $L^p$-norm 방법을 중심으로

  • 김상완;이효재;원중선
    • Proceedings of the KSRS Conference
    • /
    • 2000.04a
    • /
    • pp.96-101
    • /
    • 2000
  • SAR(Synthetic Aperture Radar) interferometry 기술은 co-registration, 정밀궤도 계산, phase unwrapping, 지형보정과 같은 기술로 구성되어있다. 구속화된 위상값을 절대 위상값으로 변환하는 과정인 phase unwrapping 기술은 정밀지형고도를 얻는데 있어서 핵심기술이다. 본 연구에서는 JERS-1 SAR 영상으로부터 interferogram을 구하고, 이로부터 추출된 위상정보를 이용하여 branch cut(Goldstein et. al, 1988), minimum discontinuity(Flynn, 1997) 그리고 minimum $L^p$-norm(Ghiglia and Romero, 1996)방법 적용결과에 대한 비교 분석을 실시하였다. Goldstein 알고리즘은 수행속동가 매우 빠르지만 residue를 연결한 branch cut에 의해 분활된 영역 내에서, 서로 다른 적분 경로로 인해 위상이 단절되었다. 영상내의 모든 화소에서 절대 위상을 구한 minimum discontinuity와 minimum $L^p$-norm 알고리즘 수행 결과는 상관관계가 0.995로 매우 유사하였는데, 가중된 불연속선의 합을 최소화하는 minimum discontinuity 알고리즘이 minimum $L^p$-norm에 비해 영상 일부 지역에서 발생하는 위상 오차를 전파시키지 않는다는 장점이 있다. Minimum $L^p$-norm 방법은 다른 두 방법과 달리 위상정보 내에 많은 잡음이 있더라도 적절한 해를 구할 수 있다는 장점이 있다. 각 방법은 대상 자료의 특성에 따라 효율성이 있으나 Flynn의 알고리즘이 지역적 특성과 무관하게 가장 효과적임을 알 수 있었다.

  • PDF

Single Path Phase-only Security System using Phase-encoded XOR Operations in Fourier Plane (푸리에 영역에서의 위상 변조 Exclusive-OR 연산을 이용한 단일 경로 위상 암호화 시스템)

  • Shin, Chang-Mok;Cho, Kyu-Bo;Kim, Soo-Joong;Noh, Duck-Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.326-333
    • /
    • 2005
  • Phase-only encryption scheme using exclusive-OR rules in Fourier plane and a single path decryption system are presented. A zero-padded original image, multiplied by a random phase image, is Fourier transformed and its real-valued data is encrypted with key data by using XOR rules. A decryption is simply performed based on 2-1 setup with spatial filter by Fourier transform for multiplying phase-only encrypted data by phase-only key data, which are obtained by phase-encoding process, and spatial filtering for zero-order elimination in inverse-Fourier plane. Since the encryption process is peformed in Fourier plane, proposed encryption scheme is more tolerant to loss of key information by scratching or cutting than previous XOR encryption method in space domain. Compare with previous phase-visualization systems, due to the simple architecture without a reference wave, our system is basically robust to mechanical vibrations and fluctuations. Numerical simulations have confirmed the proposed technique as high-level encryption and simple decryption architecture.

A study to 3D dose measurement and evaluation for Respiratory Motion in Lung Cancer Stereotactic Body Radiotherapy Treatment (폐암의 정위적체부방사선치료시 호흡 움직임에 따른 3D 선량 측정평가)

  • Choi, Byeong-Geol;Choi, Chang-Heon;Yun, Il-Gyu;Yang, Jin-Seong;Lee, Dong-Myeong;Park, Ju-Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • Purpose : This study aims to evaluate 3D dosimetric impact for MIP image and each phase image in stereotactic body radiotherapy (SBRT) for lung cancer using volumetric modulated arc therapy (VMAT). Materials and Methods : For each of 5 patients with non-small-cell pulmonary tumors, a respiration-correlated four-dimensional computed tomography (4DCT) study was performed. We obtain ten 3D CT images corresponding to phases of a breathing cycle. Treatment plans were generated using MIP CT image and each phases 3D CT. We performed the dose verification of the TPS with use of the Ion chamber and COMPASS. The dose distribution that were 3D reconstructed using MIP CT image compared with dose distribution on the corresponding phase of the 4D CT data. Results : Gamma evaluation was performed to evaluate the accuracy of dose delivery for MIP CT data and 4D CT data of 5 patients. The average percentage of points passing the gamma criteria of 2 mm/2% about 99%. The average Homogeneity Index difference between MIP and each 3D data of patient dose was 0.03~0.04. The average difference between PTV maximum dose was 3.30 cGy, The average different Spinal Coad dose was 3.30 cGy, The average of difference with $V_{20}$, $V_{10}$, $V_5$ of Lung was -0.04%~2.32%. The average Homogeneity Index difference between MIP and each phase 3d data of all patient was -0.03~0.03. The average PTV maximum dose difference was minimum for 10% phase and maximum for 70% phase. The average Spain cord maximum dose difference was minimum for 0% phase and maximum for 50% phase. The average difference of $V_{20}$, $V_{10}$, $V_5$ of Lung show bo certain trend. Conclusion : There is no tendency of dose difference between MIP with 3D CT data of each phase. But there are appreciable difference for specific phase. It is need to study about patient group which has similar tumor location and breathing motion. Then we compare with dose distribution for each phase 3D image data or MIP image data. we will determine appropriate image data for treatment plan.

The Analysis of Amplitude and Phase Image for Acoustic Microscope Using Quadrature Technique (쿼드러춰 방식에 의한 초음파현미경의 진폭과 위상영상 분석)

  • Kim, Hyun;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.55-61
    • /
    • 1999
  • In this study, we have constructed the acoustic microscope using quadrature technique and analyzed the relative variation of image intensity and the quality of image by reconstructing the amplitude and phase image for surface defects with tiny hight variation. In this experiment, we have constructed the scanning acoustic microscope using the focused transducer with 3㎒ center frequency and the quadrature detector. And we have fabricated aluminum samples with round defects whose depth is different and reconstructed the amplitude and phase images for the samples. One sample has round defects with 2㎜ diameter and 100㎛ depth and the other has round defects with 4㎜ diameter and 5㎜ depth. In the result of line scanning for the sample with 100㎛ round defects, it has been shown that the variation rate of amplitude image intensity is 7% and the variation rate of phase image intensity is 89%. The phase image has better contrast than amplitude image for the sample. In contrast to this, the amplitude image has better contrast than phase image for the sample with 5㎜ depth's defects. Accordingly there is big difference between amplitude image and phase image for depth variation of defects whose boundary is 1 wavelength. Consequently the acoustic microscope using quadrature detector can be evaluated efficiently more than using envelope detector, for detecting defects which have height variation less than 1 wavelength. And also the phase image and the amplitude image can be used for detecting defects of tiny height variation with complimentary relation.

  • PDF