Dose Distribution of Wedge filter by Dose Rate in LINAC (선형가속기의 선량율에 따른 쐐기필터의 선량분포)

  • Gwon, Taehyeong;Kim, Seunguk;Yoon, Yonghak;Won, Doyeon;Jeong, Kyeonghwan;Jung, Jaeeun;Cho, Juneho
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.323-329
    • /
    • 2015
  • This study is aimed at assessing whether dynamic wedge filters are appropriate to be used instead of physical wedge filters. The X-ray energy generated from linear accelerator is commercialize 6 MV and 10 MV. $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$ of physical wedge filter was irradiated by dose rate 100, 200, 300, 400, 500, and 600 MU/min for each angle and for comparison with a dynamic wedge filter, irradiate 96 times under the same conditions. The measurement conditions are as 100 cm source-film distance and $10{\times}10cm$ irradiated surface. A developed film was scanned and analyzed after a calibration through a dose analysis program and the dose rate was compared after calculating the standard deviation. Dynamic wedge filters make dose, scattered rays and treatment time reduced and very useful due to less irradiated doses to patients. The errors at each dose rate under the same conditions were irrelevant. Thus, treatment based on a high dose rate depending on the patient is expected to be feasible.

The Head Scatter Factor For Quasi - small Field Sizes (준소조사면에서의 산란인자)

  • 이상공;김진기;김정홍;김부길;권형철;김정수
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.13-19
    • /
    • 1995
  • The behavior of the correction factor associated with the collimator opening(head-scatter factor) were investigated for the 6MV x-ray beams of medical linear accelerator. The primary photon fluence was measured in air quasi-small fied size. Consideration in this study was given to the effect of head scatter factor with quasi-small fied size, the upper and lower collimator jaw scatter collection factors of quasi-small field (4-10cm) were measured with ion chamber. In general, the wedge factors which are used clinical practics are ignored of dependency on field sizes and depth. In wedge factors for each wedge filter were measured at various depth by using 6MV X-ray. In this present we inverstigated systematically the depth and field sizes dependency to determine the absorbed dose more accurately. Head scatter(upper-lower collimator jaw)appears to be (1) a small effect, less than 5% over the range of clinical field sizes (2) generated primarily at the flattening filter and therefored influenced most by the upper collimator setting.

  • PDF

Characteristics of dose distribution for virtual wedge (가변형 쐐기필터의 선량분포에 관한 특성)

  • 김부길;김진기
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.125-131
    • /
    • 2001
  • We was investigate the dosimetric characteristics of the virtual wedge and it compared to the conventional fixed wedge. Also we was evaluate the quality factor of the experimental multi-channel dosimetry system for virtual wedge. Recently virtual wedge technique and wedge fraction methods are available through the computer controlled asymmetric collimator or the independent jaw in medical linear accelerator for radiation therapy. The dosimetric characteristics are interpreted by radiation field analyzer RFA-7 system and PTW-UNIDOS system. Experimental multi-channel dosimetry system for virtual wedge was consists of the electrometer, the solid detector and array phantom. The solid detectors were constructed using commercially diodes for the assessment of quality assurance in radiotherapy. And it was used for the point dose measuring and field size scanning. The semiconductor detector and ion chamber were positioned at a dmax, 5 cm, 10 cm, 20 cm depth and its specific ratio was determined using a scanning data. Wedge angles in fixed and virtual type are compared with measurements in water phantom and it is shown that the wedge angle 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$were agree within 1$^{\circ}$ degree in 6, 10 MV photon beams. In PDD and beam flatness, experimental multi-channel disimetry system was capable of reproduceing the measured values usually to within $\pm$2.1% the statistical uncertainties of the data. It was used to describe dosimetric characteristics of virtual wedge in clinical photon beams. Also we was evaluate optimal use of the virtual wedge and improve the quality factor of the experimental multi-channel dosimetry system for virtual wedge.

  • PDF

Determination of Optimal Support Position and Stability for Manufacturing Filter Screen for Ships Using Wedge Wires (웨지 와이어를 이용한 선박용 필터 스크린 제작을 위한 최적 지지 위치 및 안정성 판단)

  • Son, In-Soo;Seo, Byung-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.2_2
    • /
    • pp.263-269
    • /
    • 2022
  • In this study, the optimal support position determination and stability determination of the wedge wire screen were performed for the production of the wedge wire filter screen with improved mesh screen. In order to manufacture a filter screen using a wedge wire, the support rod wedge wire is first installed according to the filtering capacity, and then spot welding is performed while rotating the profile wire. In the existing manufacturing method, it was manufactured using a 3m rod wedge wire and then cut according to dimensions, but it required the manufacture of a 6m cylindrical screen. Due to the increase in wedge wire length, it is difficult to manufacture stress concentration at sagging and fixed positions. In order to shorten the time of analysis, a single wedge wire was applied instead of a plurality of wedge wires. The reliability and validity of the interpretation were presented and the results were derived. After selecting the support point at the 2m position, structural analysis was performed on the entire filter screen to confirm stability.The purpose of this study is to identify the maximum deflection of the wire for the production of a 6m wedge wire screen and secure design basic data so that it can work safely through optimal support.