• Title/Summary/Keyword: 원형터널

Search Result 105, Processing Time 0.02 seconds

Numerical study on the charateristics of fracture growth in fracture controlled blasting using notched blasthole (노치성형 발파공을 이용한 균열제어 발파방법의 균열발생 특성에 대한 수치해석적 고찰)

  • 백승규;김재동;임한욱;류창하
    • Tunnel and Underground Space
    • /
    • v.9 no.1
    • /
    • pp.64-71
    • /
    • 1999
  • A numerical analysis was performed to investigate the effects of notched blasthole in controlling the fracture plane. Analyzed were elastic and elasto-plastic response of rock, and fracture propagation under static and dynamic load conditions. Results showed that the region exceeding the tensile strength extended up to three times the radius of a normal blasthole in elastic analysis, while fifteen times in elasto-plastic analysis. It was shown that a crack was driven from the notch tip up to the distance of 23 times the hole radius in the case of a notched blasthole with a notch of 5 mm in depth and 30 mm in length.

  • PDF

Transient heat conduction in rock mass around arch shape cold storage cavern and estimation of in-situ thermal properties (아치형 냉동저장공동 주위암반의 비정상상태 열전도 특성 및 열물성 평가)

  • Synn, Joong-Ho;Park, Yeon-Jun;Kim, Ho-Yeong;Park, Chan
    • Tunnel and Underground Space
    • /
    • v.9 no.1
    • /
    • pp.27-35
    • /
    • 1999
  • The characteristics of heat conduction for the heat source boundary like an arch shape cavern are different from those for the semi-infinite or circular boundary which can be driven theoretically. A new form of transient heat conduction equation in rock mass around the arch shape cavern is evaluated with analyzing the pattern of the rock temperature distribution measured at the cold storage pilot plant. The new equation, which is driven by adopting a shape function, $SF=\sqrt{logx_0/log(x_0+x)}$ to the solution for a semi-infinite boundary, has the semi-radial form of temperature variation with distance. And, thermal properties of rock mass are estimated by comparing the rock temperature distributions by this equation with those by measurement. Thermal conductivity and specific heat of rock mass are estimated as giving the difference of 20~25% compared to those of laboratory scale. This difference seems to be caused by discontinuity like joint and water content in rock mass.

  • PDF

The structural analysis and design methods considering joint bursting in the segment lining (조인트 버스팅을 고려한 세그먼트 라이닝 구조해석 및 설계방법)

  • Kim, Hong-Moon;Kim, Hyun-Su;Jung, Hyuk-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1125-1146
    • /
    • 2018
  • Segment lining applied to the TBM tunnel is mainly made of concrete, and it requires sufficient structural capacity to resist loads received during the construction and also after the completion. When segment lining is design to the Limit State Design, both Ultimate Limit State (ULS) and Service Limit State (SLS) should be met for the possible load cases that covers both permanent and temporary load cases - such as load applied by TBM. When design segment lining, it is important to check structural capacity at the joints as both temporary and permanent loads are always transferred through the segment joints, and sometimes the load applied to the joint is high enough to damage the segment - so called bursting failure. According to the various design guides from UK (PAS 8810, 2016), compression stress at the joint surface can generate bursting failure of the segment. This is normally from the TBM's jacking force applied at the circumferential joint, and the lining's hoop thrust generated from the permanent loads applied at the radial joint. Therefore, precast concrete segment lining's joints shall be designed to have sufficient structural capacity to resist bursting stresses generated by the TBM's jacking force and by the hoop thrust. In this study, bursting stress at the segment joints are calculated, and the joint's structural capacity was assessed using Leonhardt (1964) and FEM analysis for three different design cases. For those three analysis cases, hoop thrust at the radial joint was calculated with the application of the most widely used limit state design codes Eurocode and AASHTO LRFD (2017). For the circumferential joints bursting design, an assumed TBM jack force was used with considering of the construction tolerance of the segments and the eccentricity of the jack's position. The analysis results show reinforcement is needed as joint bursting stresses exceeds the allowable tensile strength of concrete. This highlights that joint bursting check shall be considered as a mandatory design item in the limit state design of the segment lining.

A Study on the Formation and Change in the Mordern Sajik Park (근대 사직공원의 형성과 변천)

  • Kim, Seo-Lin;Kim, Hai-Gyoung;Park, Mi-Hyun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.32 no.4
    • /
    • pp.120-131
    • /
    • 2014
  • Sajikdan(a sort of national shrine in Korea) built at the time of foundation of Joseon was entrenched into Sajik Park going through Japanese colonial era and recently the efforts to restore it is in progress. The details of change in Sajikdan in terms of diachronic analysis are as follows: Firstly, the first period refers to one prior to Japanese colonial era from the first king (also named as "Taejo" in Korean) of the Joseon Dynasty, during which it secured and strengthened the presence as a place for performing important national rites in a nation. It was built on the foot of Inwangsan Mt. at the time of the first king in Joseon Dynasty at first, was destroyed fully by fire during a Japanese Invasion period to Korea(1592-98) and afterward its ancestral ritual facilities were completed under the regime of Youngjo. However, as Japanese intervention coming to the fore, its place was destroyed and then ancestral rites were also abolished in 1908. Secondly, next period falls on 1910 to 1944 when it was transformed and entrenched into a park by the Japanese Empire. While facilities related to a park and an heterogeneous building around the part of boundary were set up, the area of altar, a ritual house and d door of Sajikdan were also designated as historical remains and treasures. Thirdly, this period refers to one from Korea's liberation year from Japanese colony(1945) to the year of 1984 when it had a mixed placeness with the statues, monuments and buildings with heterogeneous nature built. Furthermore, a door of Sajikdan was removed and reconstructed over twice due to opening of Sajik Tunnel. Fourthly, a final period falls on 1985 to the present when efforts are in progress to restore the historicity and symbolism of Sajikdan. A plan for restoration is promoted but now is a difficult time suffering from troubles caused by residents' resistance. Scrutinized historical researches through excavation investigation and residents' understanding are required altogether for restoration of Sajikdan.

Properties of Disconitinuity for the Seoul Granite in the Northeastern Part of Seoul City (서울시 북동부의 서울화강암에 대한 불연속면의 특성)

  • 정상원;정상용
    • The Journal of Engineering Geology
    • /
    • v.12 no.2
    • /
    • pp.167-178
    • /
    • 2002
  • Properties of discontinuity for Seoul Granite in northeastern part of Seoul City were analyzed by dividing structural domains into Surak and Bulam Mtn. areas. Important parameters measured among several engineering properties of a rock during tunnel excavation and road construction are as follows: 1) Orientation of joint, 2) joint spacing, 3) joint density, and 4) uniaxial compressive strength. Orientation, spacing, and density of joints can be directly measured during field investigation using scanline survey, circle-inventory method, and window survey. Uniaxial compressive strength of the rock was calculated by a simple correlation equation although it is originally necessary to prepare core samples in measuring it. Major orientations of joints measured from both areas are 3 sets of joints with different orientations. In other words, they are 2 sets of orthogonal joint and 1 set of sheet joint that is dipping at low angle, and have very similar orientations in both areas. Joint densities in both areas range from 0.039 and 0.066/cm, and average joint length are between 1.30 and 4.52m. Average joint spacing also has values from 10.3cm up to 59.6cm, and shows significant difference along specific orientation of scanlines measured. Values of uniaxial compressive strength calculated on the basis of Schmidt hammer rebound values range from 217 to 335 MPa, which indicates very strong rock type by classification of wall strength.