• Title/Summary/Keyword: 원형덕트

Search Result 22, Processing Time 0.022 seconds

Stall and Counter-measure for Large Size Axial-Flow Fan (대형축류팬의 실속과 대책)

  • Shim, Eui-Bo
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.70-77
    • /
    • 1998
  • The rise in pressure across the impeller blade of an axial flow fan depends on the angle of attack. At a low back pressure, the air volume will be large and the angle of attack is small. The gradual increase of the back pressure approached stall zone which is not stationary but travels blade to blade passage. In consequence, a region occurs around these blades with large vibration in the flow. To avoid these stall operation, the stall detector in the axial flow fans has been designed to detect stalling condition with a manometer or differential pressure switch by electric mechanism.

  • PDF

COMPARISONS BETWEEN MEASURED AND COMPUTED FLUID FLOWS AND HEAT TRANSFER IN RECTANGULAR DUCT SYSTEM (사각 덕트 계통에서 유동과 열전달의 수치계산과 실험의 비교)

  • Yoon Y.H.;Kim K.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.67-74
    • /
    • 2005
  • Fluid flow and heat transfer in rectangular duct system are measured and computed by commercial software of Star-CD for comparison between them. Three rectangular systems are investigated in this study. Those are a rectangular duct with 90 degree bended elbow, a rectangular duct with two branchs, and a circular cylinder in a rectangular duct. But heat transfer is studied only for last system. These investigations show us that the numerical solutions predict satisfactorily design factors (K-factor for the elbowed duct, distributions of flow rates into each branch from a duct, and Nusselt number around circular cylinder) even though there are some disagreements in velocity profiles and turbulent kinetic energy.

  • PDF

Reactive Acoustic Filter based on the Phase Cancellation Effect (위상 반전 현상을 이용한 덕트 소음 제거기)

  • 강종민
    • Journal of KSNVE
    • /
    • v.9 no.3
    • /
    • pp.600-606
    • /
    • 1999
  • A reactive type acoustic filter is developed based on the phase cancellation effect which is occurring in the plane wave propagation through the two paths where the cross sectional areas are reversely changing. The theory is experimentally validated by the use of a cylindrical duct and an inserted hollowed cone of which vertex part is eliminated. Noise attenuation and the filtered frequency are dependent on the area variation and the effective length of the filter. Experimental comparison shows that the filtered frequencies of 1st and 2nd mode are lower than the analytical prediction due to the mass loading effects, and the 3rd mode is in good agreement. The proposed filter can be applied as an in-duct noise filter for improving the sound quality in a narrow space for various industrial applications.

  • PDF

Local Heat Transfer Characteristics in the Wake Region of a Circular Cylinder (원형 실린더 후류 영역의 국소 열전달 특성)

  • Chang Byong Hoon
    • Journal of Energy Engineering
    • /
    • v.14 no.1
    • /
    • pp.30-36
    • /
    • 2005
  • This paper reports the experimental study of the heat transfer characteristics of the wake region behind a cylinder in cross flow. Local heat transfer coefficient was measured from the stagnation point (θ=0°) to 180°, and the variation of Nu in the axial direction along the cylinder was also studied. The results show that the heft transfer rate at the rear (θ=180°) near the duct wall can increase as much as 58% over the 2 dimensional value at the center of the duct. The heat transfer profiles in the wake region also show distinct effects of the aspect ratio and the heat transfer boundary condition.

흡입구를 포함한 액체 램제트 엔진의 3차원 유동 해석

  • 임상규;오대환;손창현;이충원
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.14-14
    • /
    • 1999
  • 액체 램제트 엔진의 특성은 흡입구를 통해 들어오는 유입공기의 상태에 따라 많이 달라진다. 흡입구에 들어오는 공기의 유입각이 일정각도를 넘어서면 유입공기의 왜곡이 심하여 정상적인 연소가 불가능 할 수 있다. 따라서 다양한 비행조건에 따른 램제트 엔진의 특성을 파악하기 위하여 외부 유입영역, 흡입구, 연소기, 노즐 및 출구 대기 영역을 함께 계산하여 유동 특성과 연소 특성을 파악하고자 하였다. 흡입구는 마하 2.0을 기준으로 설계하고, 4각 덕트에서 완만하게 원형 덕트로 변화되는 확대관의 형상으로 비행체에 붙어 있는 것으로 격자를 구성하였다. 흡입구에서의 유동 조건은 비행체을 지난 유속이 마하 2.0과 2.2의 경우에 대하여 수치 실험을 수행하였으며, 비반응 유동 해석과 연소가 있는 반응 유동해석 결과를 흡입구를 포함하지 않았던 선행 연구 결과들과 비교하였다. 유입각이 영 일 때의 흡입구를 포함한 계산 결과는 흡입구에서 생성되는 충격파에 의한 손실로 총압력이 흡입구를 포함하지 않았던 선행 연구 결과와 차이가 있었으나 유동 특성에는 큰 차이가 없었다. 그러나 유입각이 증가함에 따라 흡입구로 유입되는 공기의 량이 감소하고 그에 따른 유동의 왜곡이 심하여 연소특성에 변화를 보여 주었다.

  • PDF

Study on Measurement and Numerical Analysis for Fluid Flow past a Circular Cylinder in Rectangular Duct (사각던트 내에서 원형 실린더를 지나는 유체유동의 측정 및 수치해석에 관한 연구)

  • 김경환;윤영환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1095-1102
    • /
    • 2003
  • Flow characteristics of turbulent steady fluid flow past a cylinder in rectangular duct are measured by 5 W laser doppler velocity meter. The fluid flow is also computed by commercial software of STAR-CD for comparison between the measurement and computation. The turbulent models applied in the computations are standard K-epsilon model, RNG K-epsilon model and Chen K-epsilon model. Acurracy of standard K-epsilon model is a little bit better than acurracies of other models even though those models have almost the same order of error compared to measured data. The computations predict satisfactorily the measured velocity profiles at middle section of the circular cylinder before the fluid flow diverges. However, there are some disagreements between them at down stream from the circular cylinder.

Sound Propagation in Circular Duct Lined with Elastic Porous Noise Control Materials (소음제어용 탄성다공물질이 대어진 원형덕트 내의 음파전달)

  • 정인화;강연준
    • Journal of KSNVE
    • /
    • v.9 no.2
    • /
    • pp.302-309
    • /
    • 1999
  • In this paper, a circular lined-duct is modeled by using an axisymmetric foam finite element, which is based on elastic porous material theory of Biot. For various thicknesses of three kinds of lining materials, finite element predictions are compared with measurement results and Morse's analytical results. While the analytical model has larger error as the lining becomes thicker, results of the present model have a good agreement with experimental results for all the thicknesses considered here. It has also been found that constraining the axial motion on the circumferential surface of the lining enhances sound attenuation at low freqneucies.

  • PDF

Numerical analysis of heat transfer and friction factors in a duct having circular perforated baffles (원형 다공배플이 있는 덕트에서의 열전달과 마찰계수에 관한 수치해석)

  • Oh, S.K.;Ahn, S.W.;Ary, Bachtiar Krishna Putra;Bae, S.T.
    • Journal of Power System Engineering
    • /
    • v.16 no.4
    • /
    • pp.44-50
    • /
    • 2012
  • The present numerical study was performed to determine how the two perforated baffles( Inclined angle=$5^{\circ}$; perforation diameter=2cm) placed at a rectangular duct affect heat transfer and associated friction factors. The parametric effects of perforated baffles(3, 6 and 12 holes) and flow Reynolds number ranging from 28,900 to 61,000 on the heated target surface are explored. As for the investigation of heat transfer behaviours on the local Nusselt number with two baffles placed at $x/D_h=0.8$ and $x/D_h=0.8$ of the edge baffles, it is evident that the average Nusselt number increases with increasing number of holes, but the friction factor decreases with an increase in the hole number placed at baffles. The numerical results by commercial code CFX 10.0 are confirmed with the experimental data.

Design Guideline of Waveguide-Below-Cutoff Array for Electromagnetic Pulse Shielding (EMP 차폐 도파관의 형상 결정 가이드라인 작성)

  • Pang, Seung-Ki;Kim, Jae-Hun;Yook, Jong-Gwan;Kim, Yuna;Kim, Sangin
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.86-91
    • /
    • 2016
  • Convenient design guideline for Waveguide-below-cutoff (WBC) array is proposed to obtain the minimum waveguide length for electromagnetic pulse (EMP) shielding. The analysis includes circular, rectangular, and hexagonal WBC, determine the total length of the waveguide. When the unit side of rectangular WBC and the diagonal line of hexagonal WBC are given as 30 mm, the length of hexagonal WBC is 5 mm shorter than rectangular case with shielding effectiveness (SE) 80 dB. The length difference is deepened with SE of 100 dB, which shows approximately 30 mm shorter length for hexagonal case than others. In addition, hexagonal WBC requires much shorter length than circular WBC. In conclusion, hexagonal case is the most effective with respect to flow velocity and pressure loss for equivalent SE.

Study on the Experiment and Numerical Computation of Forced Convection Heat Transfer around Circular Cylinder in a Rectangular Duct (사각덕트 내에서 원형 실린더 주위의 강제대류 열전달에 대한 실험과 수치계산에 관한 연구)

  • 윤영환;김경환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.490-498
    • /
    • 2004
  • This paper measures the forced convective heat transfer from heated cylinder to air flow in a rectangular duct at Re$_{D}$ =2,337, 4,589, 6,621 and 7,944 through experiments. And the heat transfer is computed by 3-D numerical computation in which various turbulent models are applied. It is shown through the comparison of experimental and computed data that numerical computation with standard k-$\varepsilon$ model predicts the experimental data most accurately. Furthermore, the correlation from the computed heat transfer is almost similar to that from the experiment when Re$_{D}$ is greater than 4,589. In addition, the correlation of McAdams is the closest to that from experimental data among various correlations from literature in the range of Reynolds number.ber.