• Title/Summary/Keyword: 원형단면

Search Result 393, Processing Time 0.024 seconds

Strengthening Effect of Axial Square Concrete Members Wrapped by CFRP sheet (CFRP 쉬트로 보강된 사각형 콘크리트 압축부재의 보강 효과)

  • Moon, Kyoung-Tae;Park, Sang-Yeol;Koh, Kwang-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.2
    • /
    • pp.13-23
    • /
    • 2017
  • This study deals with the strengthening effect and behavioral characteristics of square concrete column wrapped with carbon FRP sheet. The increase in axial compression capacity comes from the confinement effect of wrapped CFRP sheet. Because of the shape of square concrete column, the confinement effect is smaller than that in circular column. For the experimental program, four parameters including the number of sheet, the size of column specimen, the aspect ratio, the corner rounding, and the transformation in shape from square to circular were selected to examine the strengthening effect and behavioral characteristics for each parameter. Experimental program comprised fifty five square concrete column specimens for different eleven types. The compression test results confirmed that the strengthening effect can be increased by the confinement of wrapped and bonded CFRP sheet. However, the confining effect was decreased with the increase of square column size. The other hand, the ductility in square concrete column greatly increased due to caging effect of CFRP sheet. The transformation in shape from square to circular considerably increased both the compressive strength and the ductility of the concrete column wrapped with CFRP sheet. In addition, using test results and existing studies, accuracy and reliability of the existing strength models for CFRP-confined square concrete are verified.

Seismic Performance and Flexural Over-strength of Hollow Circular RC Column with Longitudinal Steel Ratio 2.017% (축방향철근비 2.017%인 중공 원형 RC 기둥의 내진성능과 휨 초과강도)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Three small scale hollow circular reinforced concrete columns with aspect ratio 4.5 were tested under cyclic lateral load with constant axial load. Diameter of section is 400 mm, hollow diameter is 200 mm. The selected test variable is transverse steel ratio. Volumetric ratios of spirals of all the columns are 0.302~0.604% in the plastic hinge region. It corresponds to 45.9~91.8% of the minimum requirement of confining steel by Korean Bridge Design Specifications, which represent existing columns not designed by the current seismic design specifications or designed by seismic concept. The longitudinal steel ratio is 2.017%. The axial load ratio is 7%. This paper describes mainly crack behavior, load-displacement hysteresis loop, seismic performance such as equivalent damping ratio, residual displacement and effective stiffness and flexural over-strength of circular reinforced concrete bridge columns with respect to test variable. The regulation of flexural over-strength is adopted by Korea Bridge Design Specifications (Limited state design, 2012). The test results are compared with nominal strength, result of nonlinear moment-curvature analysis and the design specifications such as AASHTO LRFD and Korea Bridge Design Specifications(Limited state design).

Evaluation of Structural Response of Cylindrical Structures Based on 2D Wave-Tank Test Due to Wave Impact (파랑충격력에 의한 원형실린더구조물의 구조응답평가)

  • Lee, Kangsu;Ha, Yoon-Jin;Nam, Bo Woo;Kim, Kyong-Hwan;Hong, Sa Young
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.5
    • /
    • pp.287-296
    • /
    • 2020
  • The wave-impact load on offshore structures can be divided into green-water and wave-slamming impact loads. These wave impact loads are known to have strong nonlinear characteristics. Although the wave impact loads are dealt with in the current classification rules in the shipping industry, their strong nonlinear characteristics are not considered in detail. Therefore, to investigate these characteristics, wave-impact loads induced by a breaking wave on a circular cylinder were analyzed. A model test was carried out to measure the wave-impact loads due to breaking waves in a two-dimensional (2D) wave tank. To generate a breaking wave, the focusing wave method was applied. A series of 2D tank tests under a horizontal wave impact was carried out to investigate the structural responses of the cylindrical structure, which were obtained from the measured model test data. According to the results, we proposed a structural damage-estimation procedure of an offshore tubular member due to a wave impact load. Furthermore, a recommended wave-impact load is suggested that considers the minimum required thickness of each member. From the experimental results, we found that the required minimum thickness is dependent on the impact pressure located in a three-dimensional space on the surface of a tubular member.

Immersed Boundary Method for numerical Analysis of Bridge Section (가상경계법을 이용한 교량 내풍단면 유동장 수치해석)

  • Kim, Hak Sun;Lee, Sungsu;Nho, Jae Geun
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.69-69
    • /
    • 2011
  • 본 논문에서는 비정상 상태의 비압축성 유동장을 해석하기 위하여 물체맞춤격자방법이 아닌 가상경계법을 사용하였다. 가상경계법은 구조격자를 사용하여 구조물 경계면에서 Momentum Forceing을 사용하여 가상의 경계를 만들어 유동장을 해석하는 방법이다. Navier-Stoke 방정식의 수치 이산화 방법으로 Kim et al(1985)이 사용한 Fractional Step Method(FSM)을 사용하였다. 시간에 대하여 semi-implicit FSM를 사용하였고, 확산항에 대해서는 2차 정확도의 Crank-Nicolson Method를 대류항은 3차 정확도의 Runge-Kutta Method를 사용 하였다. 본 연구에서는 가상경계법을 이용한 유동장 해석이 교량 단면에 대하여 수치해석이 가능한지 검토하였다. 가상경계법은 현재 많은 연구가 유선형의 구조물에 대하여 수행되어 오고 있다. 교량 단면과 같은 각 진 구조물에 대한 검토는 아직 미비한 실정이다. 가상경계법에서 다루고 있는 구조물 경계면에서의 Momentum Forcing 방법이 유선형의 구조물에 맞추어 연구가 진행되었기 때문이다. 먼저 본 연구의 프로그램을 검증하기 위하여 원형 실린더에 대하여 가상경계법을 적용한 결과 Re 수 200에서 Strouhal Number, 양력계수, 항력계수를 이전 연구 결과와 비교하였다. Williamson(1988)과 Zhang(1995)의 연구결과와 유사한 결과를 얻을 수 있다. 그리고 교량의 단면과 같은 각진 구조물(Bluff Body)에 대하여 가상경계법 적용하였다. 본 논문의 연구에서 평가 대상으로 하고 있는 2차원 교량 단면에 대하여 유동장 해석을 하였다. 본 논문에서 정량적인 유체력과 유동장에 대한 비교 및 검토가 이루어지지 못했지만 압력장과 유선의 형태가 이론적인 값을 벗어나지 않고 있는 것으로 확인 되었다. Re 수 2700에서 전산 해석을 수행하였으며, 교량 단면 주위의 압력계수와 박리현상 그리고 후류에서의 Vortex shedding 현상이 모두 적절한 분포가 나타나는 것을 확인할 수 있었다. 따라서 가상경계법을 이용하여 각진 구조물에 대한 주위 유동장해석에 대한 가능성을 확인하였으며, 풍동실험과의 결과비교를 통하여 가상경계법을 이용하여 교량 단면 주위의 유동장 해석 결과를 정량적으로 비교할 것이다.

  • PDF

Explicit Equations of Normal Depth for Drainage Pipes (하수관 등류수심 양해법 산정식)

  • Yoo, Dong-Hoon;Rho, Jung-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.7 s.156
    • /
    • pp.527-535
    • /
    • 2005
  • The computation of normal depth is very important for the design of channel and the analysis of water flow. Drainage pipe generally has the shape of curvature like circular or U-type, which is different from artificial triangular or rectangular channel. In this case, the computation of normal depth or the derivation of equations is very difficult because the change of hydraulic radius and area versus depth is not simple. If the ratio of the area to the diameter, or the hydraulic radius to the diameter of pipe is expressed as the water depth to the diameter of pipe by power law, however, the process of computing normal depth becomes relatively simple, and explicit equations can be obtained. In the present study, developed are the explicit normal depth equations for circular and U-type pipes, and the normal depth equation associated with Hagen (Manning) equation and friction factor equation of smooth turbulent flow by power law is also proposed because of its wide usage in engineering design.

Anti-Seismic Performance Evaluation of Circular Pier By Interval Reinforcement (보강간격에 따른 원형 기둥부재의 내진 성능 평가)

  • Jang, Il-Young;Kim, Seong-Kyum;Park, Jun-Young;Yang, Jae-Yeol
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.165-165
    • /
    • 2011
  • 내진 설계규정이 적용되기 이전에 시공되어 사용 중인 교량의 경우 지진 발생시 교각의 파괴 또는 구조적 피해는 교량 전체 시스템의 붕괴를 초래하므로 지진하중에 대하여 피해를 최소화해야 한다. 이를 위해 내진설계규정이 적용되기 이전의 교량 또는 지진취약지역으로 분류된 곳의 교량, 사회적 중요도가 높은 교량에 대해 교각의 내진성능보강을 실시하고 있다. 2007년 말 국토해양부가 관리하고 있는 11,940개 교량 중 지진 발생시 피해가 우려되는 1,342개(일반국도 682개, 고속국도 600개) 교량에 대해 2006년부터 내진보강이 착수되었고 2009년에는 확대 추진하여 일반국도 80개교, 고속국도 100개교에 대한 보강을 실시하였다. 이와 같이 확대 추진되고 있는 정책에 반해, 내진보강 기술 및 제품이 부족하고 새로운 내진보강재 개발이 불가피해지고 있는 것이 현실이다. 소성영역에서의 횡방향 철근은 지진 시 종방향 철근의 좌굴과 콘크리트의 압축강도저하를 방지하며, 전단보강철근으로도 중요한 역할을 하여 교각의 전단강도를 증가시킨다. 그러나 이러한 횡방향 철근은 초기 설계에 의한 시공이 종료된 후 기존의 성능을 증가시키기 위하여 철근량을 증가하거나 단면의 변화를 주기에는 매우 어려운 일이다. 따라서 내진성능을 위한 단면력 증가를 위하여 다양한 재료의 보강재와 형식이 사용되고 있다. 본 연구에서는 원형교각 모델의 구조해석을 이용해 내진성능평가를 선행한 후 실험체를 제작, Helical Bar를 보강하여 준정적 실험을 통해 내진보강성능을 평가하였다. 압축설계강도 $f_{ck}=240kgf/cm^2$를 기준으로 교량등급 2등교인 일반적인 도로교의 1/4축소모형을 설계, 기초부는 $1,200{\times}600{\times}600$ (mm)으로 철근과 콘크리트로 구성하였으며, 기둥부는 직경 400mm, 높이 1,250mm 크기의 철근콘크리트 원형 교각 실험체를 제작하였다. 제작된 실험체는 총 3개로, 분류는 무보강 일반 실험체, Helical Bar 직경에 따른 분류, 보강간격에 따른 분류로 나누어진다.

  • PDF

Investigation on Design Requirements of Feed Water Drain and Hydrogen Vent Systems for the Prototype Generation IV Sodium Cooled Fast Reactor (소듐냉각고속로 원형로 소듐-물 반응 압력완화계통의 급수배출 및 수소방출 설계 요건 연구)

  • Park, Sun Hee;Ye, Huee-Youl;Lee, Tae-Ho
    • Korean Chemical Engineering Research
    • /
    • v.55 no.2
    • /
    • pp.170-179
    • /
    • 2017
  • We investigated design requirements of feed water drain and hydrogen vent systems for the sodium-water reaction pressure relief system (SWRPRS) of the prototype generation IV sodium cooled fast reactor (PGSFR). We evaluated the areas of the gas vent pipe of the water dump tank and the length of the water drain pipe of the steam generator to rapid drain of the water steam inside the steam generator for the normal and refueling operations, respectively. We also calculated the diameter of the gas vent pipe of the sodium dump tank which met its design pressure.

Comparison of Elderly Male's Bodice Pattern -focused on 70's and 80's

  • Cha, Su-Joung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.6
    • /
    • pp.143-154
    • /
    • 2020
  • In this study, four types of bodice patterns of elderly males in their 70s and 80s were made, and appearance evaluation was conducted through 3D simulation. For objective evaluation, airgap, cross section, color distribution, etc. were analyzed to compare differences between patterns. The pattern shape of bodice for elderly males was a pattern without darts except for the L pattern. As a result of appearance evaluation for 3D simulation, the elderly males' pattern was found to have a significant difference among the patterns on the front, side, and back items, and the H pattern was analyzed as the best pattern in all items except the armhole shape on the side. As a result of evaluating the airgap, color distribution, and cross-section, the most suitable pattern for the elderly male's body type was analyzed as the H pattern. Based on the H pattern, it is thought that the development of a pattern suitable for the upper body shape of elderly male should be made.

Enhancement of the Performance a Centrifugal Compressor in an Automobile Turbocharger by Modifying the Circumferential Inlet Height of Volute (원주방향 볼류트 입구 높이를 수정한 자동차용 터보차저 원심압축기의 성능 향상)

  • Zhou, Tianjun;Lee, Geun Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.2
    • /
    • pp.115-120
    • /
    • 2014
  • To enhance the performance of an automobile turbocharger compressor, the circumferential inlet heights of the volute were modified and the flow field for the combined region of the diffuser and volute was numerically investigated using commercial software. Basically, a well-designed volute should have a high pressure recovery coefficient and a low loss coefficient for the total pressure. In this study, two circular volutes with the same cross sectional shape and tongue angle, but circumferentially different volute inlet heights, were selected. One volute had the middle inlet in the cross-section at the circumferential angle of $90^{\circ}$ but gradually lower inlet heights for the angles between $90^{\circ}$ to $360^{\circ}$ with respect to the cross sectional center of the volute, while maintaining the same height between the tangential line connecting the lowest positions of the cross section and the line connecting the volute inlets in the circumferential direction (case 1 volute). The other volute has an inlet height that is 2 mm lower than in case 1 volute such that the tongue section has a tangential inlet (case 2 volute). The results showed that the case 2 volute had a higher total pressure ratio because of its higher pressure recovery coefficient and higher isentropic efficiency, resulting from the lower loss coefficient along the circumferential position than the case 1 volute.

An Evaluation of Blast Resistance Performance of RC Columns According to the Shape of Cross Section (단면의 형상에 따른 철근콘크리트 기둥의 폭발저항 성능 평가)

  • Kim, Han-Soo;Park, Jae-Pyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.4
    • /
    • pp.387-394
    • /
    • 2010
  • The alternative load path method based on a column removal scenario has been commonly used to protect building structures from being progressively collapsed due to probable blast loading. However, this method yields highly conservative result when the columns still have substantial load resisting capacity after blast. In this study, the behavior of RC columns with rectangular and circular sections under the blast loading was investigated and the remaining capacity of the partially damaged columns was compared. AUTODYN which is a hydrocode for the analysis of the structure on the impact and blast loading was used for this study. The blast loading was verified with the experiment results. The analysis results showed that the circular columns are preferable to the rectangular ones in respect of the blast resistance performance.