• Title/Summary/Keyword: 원주시

Search Result 461, Processing Time 0.03 seconds

Assessment of Visual satisfaction & Visual Function with Prescription Swimming goggles In-air and Underwater (도수 수경 착용시 실내와 수중에서의 시각적 만족도 및 시력 평가)

  • Chu, Byoung-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.357-363
    • /
    • 2013
  • Purpose: To investigate the visual function with prescription swimming goggles. Methods: 15 university students (mean age: $22{\pm}1.54$ years) participated, with a mean distance refractive error of RE: S-1.67 D/C-0.40 D, LE: S-1.70D/C-0.37 D. Inclusion criteria were no ocular pathology, able to wear soft contact lenses to correct their refractive error to emmetropia and able to swim. Participants were fitted with contact lenses to correct all ametropia. Subjective evaluation for satisfaction of visual acuity, asthenopia and balance were also measured using a questionnaire while wearing swimming goggles with cylinder (C+1.50 D, Ax $90^{\circ}$) compared with plano sphere outside the swimming pool area. Visual acuity was assessed using the same ETDRS chart. The prescription swimming goggles powers were assessed in random order and ranged in power from S+3.00 D to S-3.00 D in 0.50 D steps. Results: Subjective evaluation was significantly worse for the swimming goggles with cylinder than for the plano powered goggles for all 3 questions, visual acuity, asthenopia and balance. Visual acuity were significantly affected by the different power of the swimming goggles (p<0.05), but there was no significant difference between the in-air in-clinic and underwater in-swimming pool measures (p=0.173). However, visual acuity measured in the clinic was significantly better than underwater for some swimming goggle powers (+3.00, +1.00, +0.50, 0, -1.00 and -2.00 D). Conclusions: Wearing swimming goggles underwater may degrade the visual acuity compared to within air but as the difference is less than 1 line of Snellen acuity, and it is unlikely to result in significant real-life effects. Having an incorrect cylinder correction was found to be detrimental resulting in lower score of satisfaction. Considering slippery floor of swimming pool area, it can be a potential risk factor. Therefore, it is important to correct any refractive error in addition to astigmatism for swimming goggle.

Tributyltin Chloride (TBTCl) Toxicity on the Growth and Mantle Structure of the Equilateral Venus, Gomphina veneriformis (Bivalvia: Veneridae) (대복, Gomphina veneriformis의 성장과 외투막 구조에 미치는 TBTCl의 독성)

  • Park, Jung-Jun;Lee, Jung-Sick
    • The Korean Journal of Malacology
    • /
    • v.24 no.3
    • /
    • pp.229-241
    • /
    • 2008
  • Changes of growth and histopathological feature in the mantle structure of the equilateral venus, Gomphina veneriformis exposed to tribultyltin chloride (TBTCl) for 36 weeks were observed. Concentrations of TBTCl were 0, 0.4, 0.6, and $0.8{\mu}g/L$. A regression analysis by power function of SPSS was shown that the growth of experimental groups was significantly decreased after 12 weeks of exposure. For histological analysis, mantle tissues were characterized using H-E stain, AB-PAS (pH 2.5) reaction and Masson's trichrome stain, and epidermal layer thickness and mucous cell distribution were analysed using the image analyser. The mantle had 4-folds (inner-inner, inner-outer, middle, and outer) and its epidermal layer consisted of simple epithlia. A periostracum was observed in the periostracal groove between middle and outer fold. Inner epidermal layer consisted of simple ciliated columnar epithelia, but the outer epidermal layer consisted of simple non-ciliated columnar epithelia. Alcian blue positive mucous cells showed blue color (7462c, 653c) in the inner fold, violet color (2583c) in the middle fold, and blue color (647c, 7455c) in inner epidermal layer (numbers in the parenthesis are codes of Pantone process coated color). Hemolymph sinus in the mantle was extended, and mucous cells in inner plica of the middle fold were stained as blue (7455c) and violet (2587c), after 12 weeks of TBTCI exposure. Cilia and striated border were disappeared, and number of mucous cells in the inner epidermal layer was reduced. Serious histopathological changes in middle and outer fold near the periostracum were observed after 36 weeks. Moreover, epidermal layer thickness and mucous cell distribution were showed decreasing tendency as exposure time to TBTCI was increased. Results of this study suggested that TBTCl induced growth disorder with histopathological changes.

  • PDF

Serum Albumin Concentrations and Clinical Disorders by Gestational Ages in Preterm Babies (미숙아에서 재태 연령에 따른 혈청 알부민치와 임상증상과의 관계)

  • Lee, Mia;Yun, Soo;Lim, Baek Keun;Kim, Jong Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.2
    • /
    • pp.148-153
    • /
    • 2005
  • Purpose : The aim of this study was to determine the reference ranges of serum albumin levels depending on the gestational ages of preterm infants. We also intended to compare the mean serum albumin levels between groups of preterm infants that did not develop clinical disorders later, and groups that did develop clinical disorders such as respiratory distress syndrome, intraventricular hemorrhage, retinopathy of prematurity, apnea and bronchopulmonary dysplasia. We also examined the significance of serum albumin as a predictor for the development of clinical disorders. Methods : The records of 208 neonates with gestational ages from 23 weeks to 41 weeks were reviewed retrospectively. The mean albumin concentrations with reference ranges by gestational ages were determined. Statistics for each two of group were compared. Logistic regression analysis was used to model odd ratio, and 95 percent confidence interval as a mean of the association between predictors and outcome. Results : Serum albumin levels were at 23-24 weeks gestation was 2.36 g/dL, rising to 3.43 g/dL in full term babies. There were significant mean differences between the clinical groups and control groups for each clinical disorder such as respiratory distress syndrome, intraventricular hemorrhage, retinopathy of prematurity and apnea in premature babies of 30-36 weeks of gestation. Low serum albumin appeared to be associated with increased risks of clinical disorders. Conclusion : The normal serum albumin levels in preterm infants should be defined according to the gestational ages. Lower albumin levels increase the risks of the later development of clinical disorders, which are common in premature infants.

Troposhperic Ozone Pollutions in Korea during 1998-2002 Using Two Ozone Indices for Vegetation Protection (식생보호를 위한 한계농도 누적 지표로 본 1998-2002년도의 우리나라 대기권 오존 오염)

  • 윤성철;김보선
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.1
    • /
    • pp.38-48
    • /
    • 2004
  • Tropospheric ozone data in Korea for 1998-2002 were analyzed to assess the impact on vegetation. SUM06(sum of hourly concentrations at or above 0.06 ppm) and AOT40(accumulated exposure over a threshold of 40 ppb), widely used as ozone indices in the U.S. and Europe, were calculated based on hourly ozone concentration in 612 areas during 1998-2002 in Korea. SUM06 of the highest 30 areas were 5-12 ppm/hr which were almost the same levels of the U.S. average, and a crop loss of 5% would be expected. Ozone pollution in Seoul during 1998-2002 had decreased compared to that for 1990-97 except in the Northern area; however, ozone pollution in Kyunggi during 1998-2002 had been increased twice compare to the previous 5 years. Korea was divided into four regions: Seoul Metropolitan area, Jungbu, Honam, and Youngnam. Ozone pollution in the Seoul Metropolitan area was much higher during 1998-2000 than the other areas, but ozone pollution during 2001-2002 was almost the same in all four regions. Chunnam-Kwangyang na Kyungbuk-Gumi, famous industrial complexes in southern Korea, were significant ozone pollution areas. However, other industrial complexes, such as Incheon, Ulsan, and Kyunggi-Sihwa, were not polluted compared to their neighbors. Comparing all ozone indices, SUM06(yr), SUM06(3mon), AOT40(yr), AOT40(3mon), number of hours exceeding 100 ppb, 95 percentile, 99 percentile, and maximum concentration, it was determined reasonable to use SUM06(3mon), AOT40(3mon) and number of hours exceeding 100 ppb for evaluation of the chronic impact of ozone on vegetation.

Artifactual Perfusion Defects due to the Parameters of Reconstruction Filter in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT 영상에서 재구성 필터에 의한 인위적 관류결손에 관한 연구)

  • Kwark, Cheol-Eun;Lee, Kyung-Han;Lee, Dong-Soo;Park, Yong-Woo;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.41-47
    • /
    • 1995
  • Tc-99m-MIBI(Sestamibi) myocardial SPECT along with T1-201 tomographic imaging has demonstrated wide application and high image qualify sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow, The qualitative values of myocardial SPECT with Tc-99m-MIBI as well as the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection(FBP) is the common standard for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it Is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected filter parameters such as cutoff frequencies and order(Butterworth case). The cutoff frequencies basically remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable thresh-old of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Nyquist frequency would reveal severe degradation of radio-active distribution near inferior and/or Inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

A Statistical Survey of Foreign Bodies in Air and Food Passage (Report V) (식도 및 기도이물의 통계적 고찰(제5보))

  • 김기령;홍원표;이춘근;이정권;박기현;김상기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1979.05a
    • /
    • pp.6.2-6
    • /
    • 1979
  • Foreing bodies of the esophagus and tracheobronchus are likely to occur whenever a child places an inedible object in the mouth and are common in the older age group particularily in edentulous individuals or preexisting disease. Our department had already reported the statistical survey at first in 1954, successively in 1962, 1963 and 1968, respectively according to the age, sex, variety of foreign bodies, location and duration of the lodgement. Now, we have experienced the new 186 cases during the consecutive 5 year period from January 1973 to December 1977 and reported as a 5th report comparing with previous report. The results were as follows. 1. In the incidence of foreign bodies, coins were the most common and pointed metal, disc, bony fragment were followed in order in the esophagus while the peanut and corn were common in the air passage. 2) 79 cases (56.4%) were males and 61 cases (43.6%) were females in the esophagus, which was not a significant difference to note. But in the air passage, males accounted for 33 cases (71.7%) compared to 13 cases (28.3%) of females. 3) In the aspect of age incidence, child 10 years or under accounted for almost all cases in the esophagus as well as in the air passage. 4) In the location of foreign bodies in the esophagus, the first narrowing was the most common, while in the air passage right bronchus had a high incidence but the difference of incidence between right bronchus and left bronchus was not remarkable. 5) The duration of lodgement was 24 hours or less in more than half of the all cases. 6) In the aspect of kind of coin, 10 won coins accounted for majority of the cases (67.0%) but the incidence of 100 won coins were tend to increase gradually in these years.

  • PDF

Analysis of vitamin B12 in fresh cuts of Korean pork for update of national standard food composition table (국가표준식품성분표 개정을 위한 국내산 돈육의 부위별 비타민 B12 함량 분석)

  • Mun, Geum-Ju;Song, Wonju;Park, Sun-Hye;Jeong, Beom-Gyun;Jung, Gil-Rak;Choi, Kap Seong;Kim, Jin-Hyoung;Choi, Youngmin;Chun, Jiyeon
    • Food Science and Preservation
    • /
    • v.24 no.7
    • /
    • pp.983-991
    • /
    • 2017
  • This study was performed to update the National Standard Food Composition Table (NSFCT) published by Korea Rural Development Administration, especially focusing on vitamin $B_{12}$ for Korean pork. Total 7 primal and 22 retail fresh cuts of Korean pork were analyzed for vitamin $B_{12}$ and the applied immunoaffinity-HPLC was validated. Vitamin $B_{12}$ assay by immunoaffinity-HPLC obtained recoveries over 95% and coefficient variations of precision below about 10%, which met the limits required for validation acceptance. Limits of detection and quantification of immunoaffinity-HPLC were 0.01 and $0.33{\mu}g/100g$, respectively. Quality control chart showed that analysis performance was excellent during the entire of study. Vitamin $B_{12}$ contents of pork cuts significantly varied depending the types of primal and its retail cuts (p<0.05). Belly, Boston butt, rib cuts showed relatively high vitamin $B_{12}$ contents compared to other primal cuts. Vitamin $B_{12}$ content of pork retail cuts were also significantly different within the same primal cuts (p<0.05). Among 22 retail cuts, the highest vitamin $B_{12}$ was observed in Tosisal in belly primal part ($0.98{\mu}g/100g$) while both Aldeungsimsal in loin and Hongdukkaesal in hide leg were the lowest by $0.33{\mu}g/100g$. This study provides reliable vitamin $B_{12}$ data for the Korean pork fresh cuts through standard sampling, method validation and analytical quality control, which would be used for update of Korean NSFCT.

Analysis of Lymphocyte Subsets in Peripheral Blood after Radiotherapy (악성 종양 환자에서 방사선 치료 전, 후의 림프구 아형 분석)

  • Choi, Young-Min;Kim, Jeung-Kee;Lee, Hyun-Sik;Hur, Won-Joo;Kim, Jung-Man
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.229-236
    • /
    • 1996
  • Purpose : To evaluate the changes of differential counts and lymphocyte subsets in cancer patients' leukocyte before and after radiotherapy. Materials and Methods : From Dec. 1994 to Mar 1995, the changes of leukocyte and its subsets in 16 patients who received radiotherapy in the Dept. of Radiation Oncology of Dong-A University Hospital were investigated. Radiation was delivered from 2700 cGy to 6660 cGy with median dose of 5400 cGy. The results of pre- and Post-radiotherapy were analyzed by paired T-test. The results of patients Who received < 50 Gy and $\geq$ 50 Gy were analyzed by Wilcoxon test. Results : Before and after radiotherapy, there was not any significant differences in the counts of leukocyte, granulocyte and monocyte. A remarkable decrease was noted in lymphocyte counts after radiotherapy(p=0.015). T cells, B cells and natural killer cells were also decreased in number after radiotherapy but it was not significant statistically. 1 helper cells and T suppressor cells were also decreased in number(p>0.05). The ratio of T helper/suppressor cell was decreased from 1.52 to 1, 11 and it was significant statistically(p=0.016). The portion of T suppressor cell among all T cells was increased after radiotherapy (p=0.0195). No significant difference was observed in the analysis of leukocyte and its subsets between patients who received < 50 Gy and $\geq$ 50 Gy, Conclusion : Radiotherapy caused remarkable decrease in lymphocyte count and its subsets. Among all lymphocyte subsets, T helper cell might be the most vulnerable to radiation, considering decreased ratio of T helper/suppressor cell count after radiotherapy.

  • PDF

The Measurements of Plasma Cytokines in Radiation-induced Pneumonitis in Lung Cancer Patients (폐암환자에서 방사선 폐렴 예측을 위한 혈장 Cytokine측정)

  • Hur Won Joo;Youn Seon Min;Lee Hyung Sik;Yang Kwang Mo;Sin Geun Ho;Son Choon Hee;Han Jin Yeong;Lee Ki Nam;Jeong Min Ho
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.314-320
    • /
    • 2000
  • Purpose :To investigate whether changes in plasma concentrations of transforming growth factor-$\beta$1(TGF-$\beta$1), tumor necrosis factor-alpha (TNF-$\alpha$) and interleukin-6 (IL-6) could be used to identify the development of radiation-induced pneumonitis in the lung cancer patients. Methods and Materials :Seventeen patients with lung cancer (11 NSCLC, 6 SCLC) were enrolled in a prospective study designed to evaluate clinical and molecular biologic correlation of radiation-induced pneumonitis. The study began in May 1998 and completed in July 1999. All patients were treated with radiotherapy with curative intent : 1.8 Gy per day, 5 fractions per week. Serial measurements of plasma TGF-$\beta$1, TNF-$\alpha$ and IL-6 were obtained in all patients before, weekly during radiotherapy and at each follow-up visits after completion of treatment. These measurements were quantified using enzyme linked immunosorbent assay (ELISA). All patients were evaluated for signs and symptoms of pneumonitis at each follow-up visit after completion of radiotherapy. High resolution CT (HRCT) scans were obtained when signs and symptoms of pneumonitis were developed after completion of radiotherapy. Results : Thirteen patients eventually developed signs and symptoms of clinical pneumonitis 씬file four patients did not. TGF-$\beta$ 1 levels were elevated in all 13 patients with pneumonitis, which showed characteristic pattern of elevation (38.45 ng/ml at pretreatment, 13.66 ng/ml during radiotherapy, then 60.63 ng/ml at 2-4 weeks after completion of radiotherapy). The levels of TNF- $\alpha$ and IL-6 were also elevated In the group of patients who developed pneumonitis but the pattern was not characteristic. Conclusions : Changes in plasma TGF$\beta$-1 levels before, during and after radiotherapy appears to be a useful means by which to identify patients at risk for the development of symptomatic pneumonitis. Other cytokines like TNF- $\alpha$ and IL-6 shows no meaningful changes in association with radiation pneumonitis.

  • PDF

Fatigue fracture of different dental implant system under cyclic loading (반복하중에 따른 수종 임플란트의 피로파절에 관한 연구)

  • Park, Won-Ju;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.424-434
    • /
    • 2009
  • Statement of problem: Problems such as loosening and fractures of retained screws and fracture of implant fixture have been frequently reported in implant prosthesis. Purpose: Implant has weak mechanical properties against lateral loading compared to vertical occlusal loading, and therefore, stress analysis of implant fixture depending on its material and geometric features is needed. Material and methods: Total 28 of external hexed implants were divided into 7 of 4 groups; Group A (3i, FULL $OSSEOTITE^{(R)}$Implant), Group B (Nobelbiocare, $Br{\aa}nemark$ $System^{(R)}$Mk III Groovy RP), Group C (Neobiotec, $SinusQuick^{TM}$ EB), Group D (Osstem, US-II). The type III gold alloy prostheses were fabricated using adequate UCLA gold abutments. Fixture, abutment screw, and abutment were connected and cross-sectioned vertically. Hardness test was conducted using MXT-$\alpha$. For fatigue fracture test, with MTS 810, the specimens were loaded to the extent of 60-600 N until fracture occurred. The fracture pattern of abutment screw and fixture was observed under scanning electron microscope. A comparative study of stress distribution and fracture area of abutment screw and fixture was carried out through finite element analysis Results: 1. In Vicker's hardness test of abutment screw, the highest value was measured in group A and lowest value was measured in group D. 2. In all implant groups, implant fixture fractures occurred mainly at the 3-4th fixture thread valley where tensile stress was concentrated. When the fatigue life was compared, significant difference was found between the group A, B, C and D (P<.05). 3. The fracture patterns of group B and group D showed complex failure type, a fracture behavior including transverse and longitudinal failure patterns in both fixture and abutment screw. In Group A and C, however, the transverse failure of fixture was only observed. 4. The finite element analysis infers that a fatigue crack started at the fixture surface. Conclusion: The maximum tensile stress was found in the implant fixture at the level of cortical bone. The fatigue fracture occurred when the dead space of implant fixture coincides with jig surface where the maximum tensile stress was generated. To increase implant durability, prevention of surrounding bone resorption is important. However, if the bone resorption progresses to the level of dead space, the frequency of implant fracture would increase. Thus, proper management is needed.