• Title/Summary/Keyword: 원전 격납 건물

Search Result 83, Processing Time 0.027 seconds

A Study on the Nonlinear Analysis of Containment Building in Korea Standard Nuclear Power Plant (한국형 원전 격납건물의 비선형해석에 관한 연구)

  • Lee, Hong-Pyo;Choun, Young-Sun;Lee, Sang-Jin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.3
    • /
    • pp.353-364
    • /
    • 2007
  • In this paper, a nonlinear finite element analysis program NUCAS, which has been developed for assessment of ultimate pressure capacity and failure mode for nuclear containment building is described. Degenerated shell element with assumed strain method and low-order solid element with enhanced assumed strain method is adapted to microscopic material and elasto-plastic material model, respectively. Finally, the performance of the developed program is tested and demonstrated with several examples. From the numerical tests, the present results show a good agreement with experimental data or other numerical results.

MELCOR 1.8.3을 이용한 NUPEC 수소분포실험 분석

  • 최종수;이종인
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.616-621
    • /
    • 1996
  • PWR 원전의 중대사고시 격납건물내 수소거동을 모의한 NUPEC의 수소분포실험 결과를 MELCOR 1.8.3 코드를 이용하여 검증 차원의 비교분석을 수행하였다. 이 연구에서는 정확한 실험조건 및 코드의 특성을 반영하여 실험에서의 유동 및 열역학적 조건을 모두 모의하였다. 이를 통해 실험에서 나타난 수소거동 특성을 재확인하고, MELCOR 코드의 분석능력 및 특성을 평가하였다. ISP-35에 대한 비교분석을 통해 다격실 격납건물내 중대 사고시 수소 혼합 및 분포 현상에 대한 MELCOR의 분석능력을 확인하였다.

  • PDF

Inelastic Energy Absorption Factor for the Seismic Probabilistic Risk Assessment of NPP Containment Structure (확률론적 지진위험도 분석을 위한 원전 격납건물의 비탄성에너지 흡수계수 평가)

  • 최인길;서정문
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.5
    • /
    • pp.47-56
    • /
    • 2001
  • In order to assure the safety of NPP structures, margin of safety or conservatism is incorporated in each design step. Seismic risk evaluation of NPP structures is performed based on the realistic capacity and response of structure eliminated the safety margin and conservatism. In this study, the comparative study on the various evaluation methods of the inelastic energy absorption capacity was performed. The inelastic energy absorption capacity due to the nonlinear behavior of structures has significant effect on the results of seismic probabilistic risk assessment. And the comparison study of the HCLPF(high confidence of low probability of failure) values according to the inelastic energy absorption factors was performed. As a conclusion, the inelastic energy absorption factor of NPP containment structure is estimated about 1.5~1.75. It is essential to estimate the nonlinear behavior of structure and its ductility factor correctly for the seismic risk assessment.

  • PDF

Assessment of the Internal Pressure Fragility of the CANDU Type Containment Buildings using Nonlinear Finite Element Analysis (비선형 유한요소해석을 이용한 CANDU형 격납건물의 내압취약도 평가)

  • Hahm, Dae-Gi;Choi, In-Kil;Lee, Hong-Pyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.4
    • /
    • pp.445-452
    • /
    • 2010
  • In this paper an assessment of the internal pressure fragility of the CANDU type containment buildings is performed. The uncertainties of the performance of the containment buildings, material properties and tendon characteristics are referred from the in-service reports of Wolsung Unit 1. The containment buildings are modeled as a three-dimensional finite elements with considering the major opening and penetrations. A new method to evaluate the probabilistic fragility of the massive structural system is developed. The fragility curves of the target containment building are presented with repect to the failure modes and reliability levels. The center of wall is reveled as the most weak structural component of the containment building in the sense of the rupture and catastrophic rupture failure modes.

한국형 표준원전 화재사건에 대한 2단계 PSA 불확실성 분석

  • 김시달;안광일;박수용;김동하;진영호
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.881-886
    • /
    • 1998
  • 한국형 표준 원진(울진 원전 3,4호기)화해 사건에 대한 2 단계 확률론적 안전성평가 (Level 2PSA) 에서 격납건물 파손모드에 큰 영향을 준다고 판단되는 현상들에 대한 불확실성 분석을 수행하였다. 불확실성 분석 대상은 주로 민감도분석 및 기존 2단계 PSA수행결과 중요한 인자로 선정된 8가지 주요 현상들로 국한하였다. 수행 방법은 성층화 추출방식 (Latin Hypercube Sampling)으로부터 발생된 1000개의 표본을 사용하였고, 분석결과는 두가지 불확실성 측도로 제시하였으며, 사용된 코드는 2 단계 PSA 분석용 전산코드인 CONPAS 이다. 불확실성 관리측면에서. 제일 불확실성이 높은 격납건물 파손모드인 원자로 공동바닥관통의 불확실성 인자를 줄이기 위해서는 CR-EJECT 현상에 대한 불확실성 을 줄여야 할 것이다.

  • PDF

저온 용융 합금물을 이용한 울진 1,2호기 원전 캐비티에 대한 노심용융물 고압분출 실험 연구

  • 박래준;김상백;김희동;김찬수;이규정
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.783-788
    • /
    • 1998
  • 국내 프랑스 가압경수형 원전인 울진 1,2호기 캐비티의 격납건물 직접가열에 대한 특성을 분석하기 위하여 노심용융물 고압분출 실험을 수행하였다. 본 연구에서는 환형통로 면적과 파손 직경에 따라 원자로용기 압력을 변화시키면서 용융물을 저온 용융 합금물인 Wood's Metal, 증기를 질소기체로 각각 모의하여 실험을 수행하였으며, 실험 결과는 물을 용융물 상사물로 사용한 전년 실험 결과(1)와 비교.분석하였다. 실험결과, 밀도가 물보다 큰 저온 용융 합금물을 사용한 경우는 물을 사용한 실험결과보다 밀도와 용융물의 벽면 고화고착 때문에 격납건물로 방출되는 용융물 양이 적게 나타났다. 물을 상사물로 사용한 경우와 같이 노심 용융물 고압분출에는 원자로 용기 파손직경이 많은 영향을 미치고 환형통로 면적은 큰 영향을 미치지 않는 것으로 나타났다. 노심용융물 고압분출 실험에 중요한 영향을 미치는 실험 상사물의 밀도와 용융물의 벽면 고화부착에 대해서는 종합적으로 분석하는 추가 연구가 필요하다.

  • PDF

Analysis of EQ pH Condition and Fission Product Removal Capability for Nuclear Power Plant (원전의 내환경기기검증 화학환경 및 핵분열생성물 제거능력 평가)

  • Song, Dong Soo;Ha, Sang Jun;Seong, Je Joong;Jeon, Hwang Yong;Huh, Seong Cheol
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.186-190
    • /
    • 2014
  • Nuclear Power Plants require the control ability of chemical condition (pH) because pH control during transient accident such as LOCA makes an able the fission product removal capability to be maintained, stress corrosion cracking of stainless steel equipment to be prevented and the production of hydrogen by aluminum and zinc to be minimized. An NPP is designed to control the pH of containment spray and sump coolant using the spray additives 30% NaOH in the event of loss of coolant accident. In this paper, the pH of sump coolant of an NPP during LOCA was analyzed and the fission products removal constant and decontamination factor were calculated according to Standard Review Plan 6.5.2 related to spray chemical conditions of pH. The calculated pH value of recirculation mode using the computer code corresponds to 8.09~9.67, which meets the chemical environment regulation requirements. The fission product removal capability caused by containment spray system is performed to provide input to radiation analysis.