• Title/Summary/Keyword: 원자력환경기술원

Search Result 101, Processing Time 0.022 seconds

Evaluation of Bearing Capacity Enhancement Effect of Base Expansion Micropile Based on a Field Load Test (현장재하시험을 통한 선단확장형 마이크로파일의 지지력 증대효과 분석)

  • Kim, Seok-Jung;Lee, Seokhyung;Han, Jin-Tae ;Hwang, Gyu-Cheol;Lee, Jeong-Seob ;Yoo, Mintaek
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.4
    • /
    • pp.31-44
    • /
    • 2023
  • A base expansion micropile was developed to improve the bearing capacity of the micropile, which bears a simple device installed at the pile base. Under an axial load, this base expansion structure radially expands at the pile tip and attaches itself around ground, compressing the boring wall in the construction stage. In this study, conventional and base expansion micropiles were constructed in the weathered rock where micropiles are commonly installed. Further, field load tests were conducted to verify the bearing capacity enhancement effect. From the load test results, it was revealed that the shaft resistance of base expansion micropiles was about 12% higher than that of conventional micropiles. The load transfer analysis results also showed that compared to conventional micropiles, the unit skin friction and unit end bearing of base expansion micropiles were 15.4% and 315.1% higher, respectively, in the bearing zone of the micropile.

Feasibility Assessment on the Application of X-ray Computed Tomography on the Characterization of Bentonite under Hydration (벤토나이트 수화반응 특성화를 위한 X선 단층촬영 기술 적용성 평가)

  • Melvin B., Diaz;Gyung Won, Lee;Seohyeon, Yun;Kwang Yeom, Kim;Chang-soo, Lee;Minseop, Kim;Jin-Seop, Kim
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.491-501
    • /
    • 2022
  • Bentonite has been proposed as a buffer and backfill material for high-level radioactive waste repository. Under such repository environment conditions, bentonite is subjected to combined thermal, hydrological, mechanical, and chemical processes. This study evaluates the feasibility of applying X-ray CT technology on the characterization of bentonite under hydration conditions using a newly developed testing cell. The cylindrical cell is made of platic material, with a removable cap to place the sample, enabling to apply vertical pressure on the sample and to measure swelling pressure. The hydration test was carried out with a sample made of Gyeonju bentonite, with a dry density of 1.4 g/cm3, and a water content of 20%. The sample had a diameter of 27.5 mm and a height of 34 mm. During the test, water was injected at a constant pressure of 0.207 MPa, and lasted for 7 days. After one day of hydration, bentonite swelled and filled out the space inside the cell. Moreover, CT histograms showed how the hydration process induced an initial increase and later progressive decrease on the density of the sample. Detailed profiles of the mean CT value, CT standard deviation, and CT gradient provided more details on the hydration process of the sample and showed how the bottom and top regions exhibited a decrease on density while the middle region showed an increase, especially during the first two days of hydration. Later, the differences in CT values with respect to the initial state decreased, and were small at the end of testing. The formation and later reduction of cracks was also characterized through CT scanning.

Safety evaluation of type B transport container for tritium storage vessel (B형 삼중수소 운반용기 안정성 평가)

  • Lee, Min-Soo;Paek, Seung-Woo;Kim, Kwang-Rag;Ahn, Do-Hee;Yim, Sung-Paal;Chung, Hong-Suk;Choi, Heui-Joo;Choi, Jeong-Won;Son, Soon-Hwan;Song, Kyu-Min
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.2
    • /
    • pp.155-169
    • /
    • 2007
  • A transport container for a 500 kCi tritium storage vessel was developed, which could be used for the transport of metal tritide from Wolsong TRF facility to a disposal site. The structural, thermal, shielding, and confinement analyses were performed for the container in a view of Type B. As a result of structural analysis, the developed container sustained its integrity under normal and accidental conditions. The maximum temperature increase of the inner storage vessel by radiation was evaluated at $134.8^{\circ}C at room temperature. In $800^{\circ}C$ fire test, The thermal barrier of container sustained the inner vessel at $405^{\circ}C after 30 min, which temperature was allowable for the container integrity since maximum design temperature of inner vessel was $550^{\circ}C. In the evaluation of the shielding, the activity of radiation was nearly zero on the outer surface of inner vessel. Consequently the transport container for a 500 kCi tritium was evaluated to pass all the safety tests including accidental condition, so it was concluded that the designed transport container is proper to be used.

  • PDF

Ocean Circulation Model ing of East Sea for Aquatic Dispersion of Liquid Radioactive Effluents from Nuclear Power Plants (원전 액체 방사성 유출물 해양확산 평가를 위한 동해 해수순환 모델링)

  • Chung Yang-Geun;Lee Gab-Bock;Bang Sun-Young;Lee Ung-Gwon;Lee Yong-Sun
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11a
    • /
    • pp.321-331
    • /
    • 2005
  • Recently. three-dimensional models have been used for aquatic dispersion of radioactive effluents in relation to nuclear power plant siting based on the Notice No. 2003-12 'Guideline for investigating and assessing hydrological and aquatic characteristics of nuclear facility site' of the Ministry of Science and Technology (MOST) in Korea. Several nuclear power plants have been under construction or planed. which are Shin-Korl Unit 1 and 2, Shin-Wolsong Unit 1 and 2, and Shln-Ulchin Unit 1 and 2. For assessing the aquatic dispersion of radionuclides released from the above nuclear power plants, it is necessary to know the coastal currents around sites which are affected by circulation of East Sea. In this study, a three dimensional hydrodynamic model for the circulation of the East Sea of Korea has been developed as the first Phase, which Is based on the RIAMOM. The model uses the primitive equation with hydrostatic approximation, and uses Arakawa-B grid system horizontally and Z-coordinate vertically. Model domain is $126.5^{\circ}E\;to\;142.5^{\circ}E$ of east longitude and $33^{\circ}N\;and\;52^{\circ}N$ of the north latitude. The space of the horizontal grid was $1/12^{\circ}$ to longitude and latitude direction and vortical level was divided to 20. This model uses Generalized Arakawa Scheme. Slant Advection, and Mode-Splitting Method. The input data were from JODC, KNFRDI, and ECMWF. The model ing results are in fairly good agreement with schematic patterns of the surface circulation in the East Sea The local current model and aquatic dispersion model of the coastal region will be developed as the second phase. The oceanic dispersion experiments will be also tarried out by using ARGO Drifter around a nuclear pelter plant site.

  • PDF

A Study on the Historical Development of Research Community in Korea: Focused on the Government Supported Institutes (연구자 집단의 성장과 변천: 정부 출연 연구 기관을 중심으로)

  • Park Jin-Hee
    • Journal of Science and Technology Studies
    • /
    • v.6 no.1 s.11
    • /
    • pp.119-152
    • /
    • 2006
  • This paper deals with the historical development of research community in Korea. As the former studies of the korean scientific community show, the government supported institutes played an important role in the formation of research community. Therefore the theme of this study is concerned with the historical development of the government supported institutes and the features of their researcher group. In this paper following questions will be answered: How the social status of these researcher group is changed, what kind of response on social problems or national politics they had, and which characteristic they showed with regards to the identity problem. After the korean liberation the government institutes, such as the Chungang Kongop Yonguso(industrial research center)and the Korean Atomic Energy Research Institute, contributed to the development of the first generation of research group. However this research group could hardly identify themselves as researcher, because they spent much time on testing, evaluation or education. The identity problem is also resulted from the deficiency of authority as research institute. The status of researcher had no difference from that of civil servant. With the establishment of KIST the korean research community came into blossom. The government supported institutes, which were founded after the model of KIST, allowed quantitative and qualitative growth of research community. Thanks to the guarantee of institutional authority and the new reward system, the researcher could get respect and improve its social status. During this period the researcher volunteered to help the government policies. We can find often the nationalistic statements in the research community. During 1990s the research group demonstrated different behaviors and attitude toward the government. The nationalistic ideology disappeared. Instead of that, the research group criticized the government policies and took actions against the government. Those changes are related with the lowered position of government supported institutes.

  • PDF

Development of a Raman Lidar System for Remote Monitoring of Hydrogen Gas (수소 가스 원격 모니터링을 위한 라만 라이다 시스템 개발)

  • Choi, In Young;Baik, Sung Hoon;Park, Nak Gyu;Kang, Hee Young;Kim, Jin Ho;Lee, Na Jong
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.4
    • /
    • pp.166-171
    • /
    • 2017
  • Hydrogen gas is a green energy sources because it features no emission of pollutants during combustion. But hydrogen gas is very dangerous, being flammable and very explosive. Hydrogen gas detection is very important for the safety of a nuclear power plant. Hydrogen gas is generated by oxidation of nuclear fuel cladding during a critical accident, and leads to serious secondary damage in the containment building. This paper discusses the development of a Raman lidar system for remote detection and measurement of hydrogen gas. A small, portable Raman lidar system was designed, and a measurement algorithm was developed to quantitatively measure hydrogen gas concentration. To verify the capability of measuring hydrogen gas with the developed Raman lidar system, experiments were carried out under daytime outdoor conditions by using a gas chamber that can adjust the hydrogen gas density. As results, our Raman lidar system is able to measure a minimum density of 0.67 vol. % hydrogen gas at a distance of 20 m.

Local Government Response Strategies for Discharging Fukushima Radioactive Water: A Case in Busan, Ulsan, Jeju (후쿠시마 원전 오염수 방류에 따른 지자체 대응 전략: 부산, 울산, 제주 사례 위주로)

  • Won-Jo Jung;Ho-seok Nam;Min-seok Jwa;In-Hoe Jung
    • Journal of Navigation and Port Research
    • /
    • v.47 no.3
    • /
    • pp.174-181
    • /
    • 2023
  • Five local governments along the Korea-Japan Sea (Jeju, Jeonnam, Gyeongnam, Busan, Ulsan) operate a joint countermeasure committee regarding the marine discharge of contaminated water from the Fukushima nuclear power plant by Japan's Tokyo Electric Power Plant. This study compared and analyzed citizen surveys, response strategies, and detailed action plans conducted by the Jeju Research Institute, Busan Research Institute, and Ulsan Research Institute as part of a study on countermeasures for the marine discharge of contaminated water from the Fukushima nuclear power plant in Japan. The purpose was to present basic data for the preparation of effective measures. As a result of the perception survey, all citizens of local governments showed a strong negative perception of marine discharge regardless of scientific research results, and it is expected that future fisheries and tourism industries will suffer great damage. In response strategies for each local government, building a control tower was found to be the most urgent task common to all local governments. It is judged that this is because it is necessary to break away from the organization-centered system and to respond to the function-centered system for effective response. In terms of response methods, while Jeju and Busan established response plans for each sector, Ulsan City focused on practical responses with step-by-step response measures according to the release time. In terms of content, the establishment of a marine product radiation inspection system and publicity to relieve public anxiety were important. As the marine discharge of contaminated water from the Fukushima nuclear power plant is scheduled to continue until 2030, strengthening the network for sharing research results and achievements among local government research institutes was deemed necessary.

Case Studies of Site Investigation Factors and Methods for Site Selection for High-Level Radioactive Waste Disposal (고준위방사성폐기물 처분 부지선정을 위한 조사인자 및 조사기법에 대한 국외사례 분석)

  • Hyo Geon Kim;Si Won Yoo;Dae Seok Bae;Soo Hwan Jung;Ki Su Kim;Jun Kyum Kim;Man Ho Han;Junghae Choi
    • The Journal of Engineering Geology
    • /
    • v.33 no.4
    • /
    • pp.611-626
    • /
    • 2023
  • Overseas examples of the characterization stage of site selection proposed by the International Atomic Energy Agency were reviewed to highlight the factors necessary for consideration in the deep disposal of high-level radioactive waste. Studies in Sweden, Finland, the USA, and Canada were considered. Site investigations in Sweden and Finland commonly covered the fields of geology, hydrogeology, and hydrogeochemistry using similar field investigation techniques. The USA considered survey groups and factors under pre- and post-lockdown guidelines, as well as those for desaturated and saturated surveys. involving geophysical, hydrological, hydrogeological, hydrogeochemical, mechanical/physical, and thermal-characterization investigations. Canada provided a list of investigative methods for both preliminary and detailed site assessments including geological, physical, boring, hydrological, laboratory testing, and chemical analysis studies. Results of this study should elucidate site-selection investigation factors and survey methods applicable to Korea.

Analysis of long-term water level change of Dongrae hot spring using time series methods (시계열 방법을 이용한 동래온천 수위의 장기적인 변화 분석)

  • Jeon, Hang-Tak;Hamm, Se-Yeong;Cheong, Jae-Yeol;Lee, Cheol-Woo;Lee, Jong-Tae;Lim, Woo-Ri
    • Journal of the Geological Society of Korea
    • /
    • v.54 no.5
    • /
    • pp.529-544
    • /
    • 2018
  • Dongrae hot spring belongs to the residual magma type and has a long history of bathing since the Silla dynasty in Korea. Due to long development of hot spring water, it is expected that the amount of hot spring water in Dongrae hot spring has been changed. In this study, long-trem water level data of Dongrae hot spring were examined for recognizing the change of the hot spring. By the fluctuation analysis of the hot spring water level from January 1992 to July 2018, the maximum and minimum annual drawdowns of no. 27 well were 137.70 and 71.60 meters, respectively, with an average drawdown of 103.39 m. On the other hand, the maximum and minimum annual drawdowns of no. 29 well were 137.80 and 71.70 meters, with an average drawdown of 103.49 m. Besides, drawdown rate became bigger in recent years. As a result of analyzing autocorrelation of the two wells, the correlation coefficient ranged from 0.919 to 0.991, showing seasonal groundwater level fluctuation. The cross correlation analysis between water level and precipitation as well as water level and hot spring discharge resulted in the correlation coefficients of -0.280 ~ 0.256 and 0.428 ~ 0.553, respectively. Therefore, using Dongnae hot-spring water level data from 1992 to 2018, the Mann-Kendall test and Sen's test showed that the continuous decline of water level was mainly caused by the pumping of the hot spring water among various reasons.

Development of Dust Recycling System and Dust Cleaner in Pipe during Vitrification of Simulated Non-Radioactive Waste (모의 비방사성폐기물의 유리화시 발생 분진의 재순환처리장치 및 배관 내 침적분진에 의한 막힘 방지용 제진장치의 개발)

  • Choi Jong-Seo;You Young-Hwan;Park Seung-Chul;Choi Seok-Mo;Hwang Tae-Won;Shin Sang-Woon
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.110-120
    • /
    • 2005
  • For utilizing vitrification to treat low and intermediate level waste, industrial pilot plant was designed and constructed in October 1999 at Daejon, Korea through the joint research program among NETEC, MOBIS and SGN. More than 70 tests were performed on simulated IER, DAW etc. including key nuclide surrogate(Cs, Co); this plant has been shown to vitrify the target waste effectively and safely, however, some dust are generated from the HTF(High Temperature Filter) as a secondary waste. In case of long term operation, it is also concerned that pipe plugging can be occurred due to deposited dust in cooling pipe namely, connecting pipe between CCM(Cold Crucible Melter) and HTF. In this regard, we have developed the special complementary system of the off-gas treatment system to recycle the dust from HTF to CCM and to remove the interior dust of cooling pipe. Main concept of the dust recycling is to feed the dust to the CCM as a slurry state; this system is regarded as of an important position in the viewpoint of volume reduction, waste disposal cost and glass melt control in CCM. The role of DRS(Dust Recycling System) is to recycle the major glass components and key nuclides; this system is served to lower glass viscosity and increase waste solubility by recycling B, Na, Li components into glass melt and also to re-entrain and incorporate into glass melt like Cs, Co. Therefore dust recycling is helpful to control the molten glass; it is unnecessary to consider a separate dust treatment system like a cementation equipment. The effects of Dust Cleaner are to prevent the pipe plugging due to dust and to treat the deposited dust by raking the dust into CCM. During the pilot vitrification test, overall performance assessment was successfully performed; DRS and Dust Cleaner are found to be useful and effective for recycling the dust from HTF and also removing the dust in cooling pipe. The obtained operational data and operational experiences will be used as a basis of the commercial facility.

  • PDF