• Title/Summary/Keyword: 원자력의학원

Search Result 109, Processing Time 0.035 seconds

Rooting, Growth, and Color Mutation of Poinsettias Affected by Gamma Radiation (감마선 조사가 포인세티아의 발근, 생육 및 색상변이에 미치는 영향)

  • Lee, Eun Kyung;Kim, Won Hee;Kim, Seung Tae;Kang, Si Yong
    • Journal of Radiation Industry
    • /
    • v.4 no.3
    • /
    • pp.253-257
    • /
    • 2010
  • This experiment was carried out to investigate the effects of gamma-radiation on the rooting, growth, and color mutation in poinsettia. Using 10 poinsettia varieties ('Lollipop', 'Little Peace', 'Happy Day', 'Early Bird', 'Pixy Red', 'Happy Time', 'Heidi', 'Red Bell', 'Clara', and 'Scarlet') bred by National Institute of Horticultural and Herbal Science, 100 Gy of gamma ray was irradiated at the stage of callused cuttings. Four weeks after sticking cuttings in the rooting media, 8 cultivars showed 100% of root formation, but 'Early Bird' rooted 24.4% and even died off during the cutting propagation. After planting rooted cuttings, survival rate until flowering time varied among irradiated cultivars. While 'Pixy Red' and 'Heidi' survived about 98%, 'Clara', 'Happy Day', and 'Early Bird' survived lesser than 30%. All irradiated plants showed remarkably shorter plant height, lesser branch numbers than non-irradiated control plants. Thirty color mutants were obtained among 281 plants survived until flowering time. Nine mutants were complete color mutated branches, whereas 21 mutants were partially color mutated bracts and transitional leaves. Color patterns mutated by 100 Gy of gamma ray were divided into pink, hot pink, light red and spotted (pink spots with red main color). Pink mutants were commonly obtained. Complete color mutants were discovered from 4 plants of 'Pixy Red', 2 plants of 'Red Bell' and 3 plants of Lollipop.

Analysis on the Oceanic Circulation and Pollutant Transport near a Wolsung Nuclear Power Plant (월성원전주변의 해수유동 및 오염물 이동해석)

  • Park, Geon-Hyeong;Kim, Ki-Chul;Lee, Jung-Lyul;Suh, Kyung-Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.250-250
    • /
    • 2011
  • 지정학적으로 3면이 바다로 접하고 있는 우리나라 해안가 주변의 원자력발전소는 관류형 냉각 방식(Once-through cooling System)을 채택하고 있기에, 이 계통을 통과한 냉각수는 주변해역으로 흘러들어가 주변 환경에 영향을 줄 수 있다. 또한 동해 주변 인접국들의 활발한 원자력 이용과 방사능 물질의 수송 등으로 인해 방사능 사고 위험이 증대됨에 따라 동해 원전 주변의 해양방사성물질 거동에 대한 필요성이 제기되고 있다. 이에 따라 동해의 해양환경을 조사 분석하여 해역에서의 오염 물질의 거동 파악이 중요하고, 산업시설 주변 연안의 오염물 이동 및 해석을 위해 오염물의 시 공간적으로 농도를 추정하는 것이 중요한 사항이다. 따라서 본 연구에서 수직 수평적으로 2차원 및 3차원화가 용이한 EFDC 모델을 사용하였다. 국립해양조사원에서 발간하는 DC103의 수치해도를 이용하여 모델영역은 동서방향으로 171km, 남북방향으로 235km로 설정하고, 격자간격은 $1km{\times}1km$의 정방향 격자를 사용하여 동해 월성 주변의 조위 시계열 검증 및 조화분석을 통한 검증을 실시한 결과 관측한 결과와 양호한 재현성을 나타내었다. 또한 국립수산과학원에서 제공되고 있는 년별 수온, 염분 자료 등의 해양환경과 지형적 특성을 고려하여 오염 물질의 이동 경로를 파악함으로써 사고시 피해를 줄이고자 한다.

  • PDF

Development of Dual FDG Auto Synthesis Module (듀얼 FDG 자동합성장치 개발)

  • Jeong, Cheol-Ki;Lee, Goung-Jin;Hur, Min-Goo;Jang, Hong-Suk;Min, Young-Don
    • Journal of Radiation Industry
    • /
    • v.5 no.4
    • /
    • pp.313-316
    • /
    • 2011
  • [$^{18}F$]FDG (2-[$^{18}F$] Fluoro-2-deoxy-D-Glucose), which is required Automated Synthetic Module for production, is most often used Radiopharmaceuticals in nuclear medicine. In this study, an Automated Synthesis Module was developed to produce FDG in two consecutive time when F-18 feds continuously by modifying a domestic FDG Automated Synthetic Module on structural geometry and control system. The results were showed that the Average Synthesis Yields on the developed Automated Synthetic Module were $45{\pm}3%$ (n=20), $50{\pm}3%$ (n=20) respectively. The Quality Control results, such as Radio TLC, Radiochemical purity, Gamma-counter, pH, LAL Test, Micro bacteria test, showed in same level with domestic [$^{18}F$]FDG Auto-Synthetic modules. Therefore, if some features were improved by considering the components life time and appearance, commercial sales can be expected because of low price and easy maintenance compared with foreign products.

Experiences of Precocious Puberty in Primary School Girls with Hormone Therapeutics (호르몬 치료를 받은 초등학교 여아의 성조숙증 경험)

  • Cheon, Soon-Mi;Jung, Hye-Young
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.25 no.4
    • /
    • pp.459-470
    • /
    • 2019
  • Purpose: The purpose of this qualitative study was to identify the nature of precocious puberty and to explore what it means in primary schools. Methods: The participants of this phenomenological study were nine primary school girls who were diagnosed with precocious puberty and experienced hormone therapeutics, applying a convenience sampling method. Data were collected from July 2017 to January 2018 through individual in-depth interviews of the participants, including gestures, facial expressions and nonverbal means. The data analysis followed the method of Giorgi. Results: The study identified 37 concepts, 12 clusters, and five themes from experiences of precocious puberty. The essential five themes were as follows: 'ashamed and concealing experience', 'there is no therapeutics option', 'difficulties in the process of therapeutics', 'difficulties in daily life', and 'ambivalence toward therapeutics'. Conclusion: The findings of this study indicate physical, psychological and social difficulties faced by girls with precocious puberty. Based on this results of the study, it is necessary to develop nursing intervention programs focusing on healthy growth and development for children with precocious puberty.

Nurses' Compliance with Safety Guidelines for the Use of Antineoplastic Agents, Observable Symptoms, and Stress from Occupational Exposure (간호사의 항암제 안전관리지침 수행도, 노출로 인한 자각증상 및 스트레스의 관계)

  • Park, Seon-Ja;Kim, Hyun-Ju
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.25 no.4
    • /
    • pp.293-300
    • /
    • 2018
  • Purpose: This study was done to identify the relationship between nurses' compliance with safety guidelines for the use of antineoplastic agents, observable symptoms, and stress from occupational exposure. Methods: The participants were 172 nurses from six general hospitals in a metropolitan area. They had administered antineoplastic agents at least three months prior to the study. Data were collected using self-report questionnaires, and then analyzed using SPSS/WIN 23.0 for descriptive statistics, t-test, one-way ANOVA, $Scheff\acute{e}$ method, and Pearson correlation coefficient. Results: The average score on the guideline for safety compliance was 87.75 points out of a total of 100. The average score for observable symptoms of exposure to antineoplastic agents was 30.12 (28~56) points, and that for mean stress was 33.52 (15~60) points. Observable symptoms and stress from occupational exposure showed a statistically significant positive correlation (r=0.34, p<.001). Conclusion: To increase the degree of compliance with safety guidelines for antineoplastic agents, hospitals should lower the chance of exposure to antineoplastic agents, as well as minimize the observable symptoms and stress from occupational exposure. Periodic education and policy support are needed to improve compliance with safety guidelines for antineoplastic agent use.

Comparison of General Concrete and Low-radiation Concrete as Shielding Materials for Medical Linear Accelerators (의료용 선형가속기 차폐 재질로써 일반 콘크리트와 저 방사화 콘크리트 비교)

  • Lee, Dong Yeon;Kim, Jung Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.45-53
    • /
    • 2019
  • This study is a neutron activation for concrete that shields medical linear accelerator facilities. Comparison of general concrete and low activation concrete. The simulation method was simulated using MCNPX (Ver. 2.5.0) and FISPACT-2010, and the shielding ability for photon and neutron beams was calculated and neutron activation evaluation was carried out. As a result, the shielding capacity was 20 ~ 50 cm efficient in general concrete, and activate evaluation in low activation concrete was calculated to be low in radioactivity concrete, but all were estimated to not exceed their own allowable concentration in self - disposal. As a result of the comprehensive analysis, it is considered effective to use ordinary concrete.

Differences in Patient Characteristics between Spasmodic Dysphonia and Vocal Tremor (연축성 발성장애와 음성 진전 환자의 감별)

  • Son, Hee Young
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.32 no.1
    • /
    • pp.9-14
    • /
    • 2021
  • Spasmodic dysphonia, essential tremor, and vocal tremor related with Parkinson's disease are different disorders showing fairly similar symptoms such as difficulty in the speech onset, and tremble in the voice. However, the cause and the resulting treatment of these diseases are different. Spasmodic dysphonia is a vocal disorder characterized by spasms of the laryngeal muscles during a speech, invoking broken, tense, forced, and strangled voice patterns. Such difficult-to-treat dysphonia disease is classified as central-origin-focal dystonia, of a yet unknown etiology. Its symptoms arise because of intermittent and involuntary muscle contractions during speech. Essential tremor, on the other hand, is characterized by a rhythmic laryngeal movement, resulting in alterations of rhythmic pitch and loudness during speech or even at rest. Severe cases of tremor may cause speech breaks like those of adductor spasmodic dysphonia. In the case of hyper-functional tension of vocal folds and accompanying tremors, it is necessary to distinguish these disorders from muscular dysfunction. A diversified assessment through the performance of specific speech tasks and a thorough understanding for the identification of the disorder is necessary for accurate diagnosis and effective treatment of patients with vocal tremors.

A structural equation model of organizational commitment by hospital nurses: The moderating effect of each generation through multi-group analysis (병원간호사의 조직몰입 구조모형: 다중집단분석을 통한 세대별 조절 효과)

  • Chae, Jeong Hye;Kim, Young Suk
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.28 no.3
    • /
    • pp.305-316
    • /
    • 2022
  • Purpose: The purpose of this study was to construct a structural equation model of organizational commitment in hospital nurses based on a job demands-resources model and to confirm the moderating effect(s) according to the nurses' generation. Methods: The model was constructed of the exogenous variables of social support, emotional intelligence, emotional labor, and job conflict and the endogenous variables of burnout, job engagement, and organizational commitment. The participants were 560 hospital nurses working in 3 general hospitals. Data were collected from August 1 to September 30, 2021, and analyzed using SPSS Window 23.0 and IBM AMOS 23.0. Results: The strongest factor directly influencing hospital nurses' organizational commitment was social support. In a multiple group analysis, nurses' generation had a partial moderating effect. In a generation-specific analysis, the Z generation group was higher than the X and Y generation groups in the variables of emotional labor and burnout related to organizational commitment. Conclusion: Based on the findings of this study, to improve hospital nurses' organizational commitment, social support is needed as an important management strategy. At the organizational level, we need to develop ways to improve organizational commitment by reducing the emotional labor and burnout of Generation Z.

Radiological Impact Assessment for Radioactive Concrete in Dismantling of the Medical Cyclotron (의료용 사이클로트론 해체 시 발생되는 방사화 콘크리트의 방사선학적 영향평가)

  • Jang, Donggun;Shin, Sanghwa
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.73-80
    • /
    • 2019
  • Neutrons are generated by the nuclear reaction, which is absorbed into the concrete wall and causes the activation during cyclotron operation. The purpose of this study is to investigate the effect of neutron activation and radiative concrete on concrete type. This experiment used Monte Carlo simulation and RESRAD model. The results of the experiment showed that the higher the content of Fe in concrete, the greater the shielding rate. The effect of $^{56}Fe(n,\;2np)^{54}Mn$ reaction on workers is also increased. However, radioactive nuclides have low activity and have very low impact on workers. Radioactive concrete should be treated as general wastes with less than its self-disposal tolerance level, and it should be recycled to the surface such as road repair rather than landfill to minimize the effect of $^{14}C$.

The Necessity of Resetting the Filter Criteria for the Minimization of Dose Creep in Digital Imaging Systems (디지털 영상 시스템에서 선량 크리프 최소화를 위한 부가 필터 두께 권고 기준의 재설정에 대한 연구)

  • Kim, Kyo Tae;Kim, Kum Bae;Kang, Sang Sik;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.757-763
    • /
    • 2019
  • Recently, Following the recent development of flat panel detector with wide dynamic ranges, increasing numbers of healthcare providers have begun to use digital radiography. As a result, filter thickness standards should be reestablished, as current clinical practice requires the use of thicknesses recommended by the National Council on Radiation Protection and Measurements, which are based on information, acquired using conventional analog systems. Here we investigated the possibility of minimizing dose creep and optimizing patient dose using Al filters in digital radiography. The use of thicker Al filters resulted in a maximum 19.3% reduction in the entrance skin exposure dose when medical images with similar sharpness values were compared. However, resolution, which is a critical factor in imaging, had a significant change of 1.01 lp/mm. This change in resolution is thought to be due to the increased amount of scattered rays generated from the object due to the X-ray beam hardening effect. The increase in the number of scattered rays was verified using the scattering degradation factor. However, the FPD, which has recently been developed and is widely used in various areas, has greater response to radiation than analog devices and has a wide dynamic range. Therefore, the FPD is expected to maintain an appropriate level of resolution corresponding to the increase in the scattered-ray content ratio, which depends on filter thickness. Use of the FPD is also expected to minimize dose creep by reducing the exposure dose.