• Title/Summary/Keyword: 원격조작기

Search Result 79, Processing Time 0.028 seconds

A Force Reflecting and Compliant Control for Heavy-Duty Power Telemanipulators with Control Input Saturation (제어입력 포화를 고려한 고하중 원격조작기의 힘반영 유연성 제어)

  • An, Seong-Ho;Yun, Ji-Seop;Lee, Sang-Jeong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.5
    • /
    • pp.22-33
    • /
    • 2000
  • Since the heavy-duty power manipulator generally has high ratio gear reducers at its joints, its dynamic characteristics is much slower than that of the master manipulator and it is likely to encounter the saturation in the input magnitude when it is used as the slave manipulator in telemanipulation systems. This paper proposes a force reflecting and compliant control scheme for the heavy-duty power telemanipulator. The main advantage of the proposed scheme is that it provides a precise position and compliant control performance for a telemanipulator with control input saturation. The stability of the proposed scheme is analyzed and a series of experiments shows its performance.

  • PDF

Stiffness Analysis of Spring Mechanism for Semi-Automatic Gripper Motion of Tendon-Driven Remote Manipulator (와이어 구동방식 원격조작기용 그리퍼의 반자동 파지 및 해제 동작을 위한 스프링 강성 분석)

  • Yu, Seung-Nam;Lee, Jong-Kwang
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.11
    • /
    • pp.1405-1411
    • /
    • 2012
  • Remote handling manipulators are widely used for performing hazardous tasks, and it is essential to ensure the reliable performance of such systems. Toward this end, tendon-driven mechanisms are adopted in such systems to reduce the weight of the distal parts of the manipulator while maintaining the handling performance. In this study, several approaches for the design of a gripper system for a tendon-driven remote handling system are introduced. Basically, this gripper has an underactuated spring mechanism that is combined with a slave manipulator triggered by a master operator. Based on the requirements under the specified tendon-driven mechanism, the connecting position of the spring system on the gripper mechanism and kinematic influence coefficient (KIC) analysis are performed. As a result, a suitable combination of components for the proper design of the target system is presented and verified.

Implementation of Real-Time Bilateral Control of Fuzzy Robot Hand using Analytic Hierachy Process (계층적 분석방법을 이용한 실시간 퍼지로봇핸드의 양방향 제어의 구현)

  • Jin, Hyun-Soo;Hong, Yoo-Sik
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.5
    • /
    • pp.525-532
    • /
    • 2004
  • Telemanipulator is distingushed from industrial robot by iterating same specified work. Manipulator operator is included in control loop for controlling the telemanipulator because he decide directly during the work and order controllabily. We implement fuzzy controller for reducing the modelling error of telemanipulator which depend on the PID controller. But position-force control method of bidirectional control impose unsafety of vibiration and Analytic Hierchy method can stabilize for reducing nonlinear modelling error by expert operator because of transformation empirical control rule to linear model.

Development of Automatic Remote Exposure Controller for Gamma Radiography (감마선투과검사 장치의 자동 원격조작기 개발)

  • Joo, Gwang-Tae;Shin, Jin-Seong;Kim, Dong-Eun;Song, Jung-Ho;Choo, Seung-Hwan;Chang, Hong-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.490-499
    • /
    • 2002
  • Recently, gamma radiographic equipments have been used about 1,000 sets manually and operated by about 2,500 persons in Korea. In order for a radiography to work effectively with avoiding any hazard of the high level radiation from the source, many field workers have expected developing a wireless automatic remote exposure controller. The KlTCO research team has developed an automatic remote exposure controller that can regulate the speed of $0.4{\sim}1.2m/s$ by BLDC motor of 24V 200W which has output of $54kgf{\cdot}cm$, suitable torque and safety factor for the work. And the developed automatic remote exposure controller can control rpm of motor, pigtail position by photo-sensor and exposure time by timer to RF sensor. Thus, the developed equipment is expected that the unit can be used in many practical applications with benefits in economical advantage to combine the use of both automatic and manual type because attachment is possible existent manual remote exposure controller, AC and DC combined use.

미국의 인쇄기 원격정비 시스템

  • Jo, Gap-Jun
    • 프린팅코리아
    • /
    • s.38
    • /
    • pp.116-117
    • /
    • 2005
  • 상업 인쇄기들에 대한 원격 진단(remote diagnostics)은 이제 더 이상 새로운 것이 아니다. 인쇄기 조작원이 발견한 문제점을 인쇄기에 장착한 전화로 연결(dial-up)함으로써 인쇄기 제조업체들이 공유할 수 있도록 하는 이 시스템은 이미 십여년 동안 소프트웨어 업데이트와 보완을 거치며 발전해왔다.

  • PDF

A study on robotic telesurgery system and the state of the art (원격 수술 로봇시스템에 관한 연구와 현황)

  • 추길환;김도윤;정명진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1524-1527
    • /
    • 1997
  • 로봇기술의 발달로 인하여 로봇의 활용 분야는 점차 확대되고 있으며 의료 및 재활분야에도 이용되는 추세이다. 의료분야에 이용되는 메디칼 로봇은 최소 절개 수술에 적용하는 경우 많은 이점을 얻을 수 있다는 점과 전문의사가 현장에 있기 힘든 오지나 낙도 또는 전쟁터 같은 곳에서도 원격 수술이 가능하다는 장점으로 많은 관심을 받고 있다. 원격 수술은 수술 계획, 로봇에게 환자 등록, 원격 수술 시행의 세가지 과정을 거치게 된다. 본 논문에서는 원격 수술을 위한 위 과정의 연구 동향을 기술하고 현재 본 실험실에서 수행하고 있는 연구 내용을 다룬다. 원격 수술을 위한 의료시스템을 구축하기 위해 팬-틸터 구동부를 가지 스테레어 시각 시스템을 제작하고 여기서 얻어지는 정보를 HMD에 투시하여 현장감을 느끼게 만드는 것과 수술대에서 환자를 수술하는 듯한 느낌을 제공할 수 있는 기술인 매스터 조작기와 슬레이브 조작기 사이의 힘 피드백 구현에 대해 다룬다.

  • PDF

Design and Implementation of Remote Diagnosis Support System for Surgery Simulation on Clubfoot (소아만곡족 수술 시뮬레이션을 위한 원격 진단보조시스템 설계 및 구현)

  • 홍헬렌
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1998.10a
    • /
    • pp.192-195
    • /
    • 1998
  • 족부(足部)의 구조적 복잡성으로 인하여 부상이나 질병을 진단하거나 수술계획을 수립하는데 있어 많은 어려움이 있다. 본 논문에서는 소아만곡족(小兒巒曲足) 수술 시뮬레이션을 위한 원격 진단보조시스템을 설계하고 구현하였다. 본 시스템은 족부를 구성하는 뼈간의 관계를 정의하고 기형 정도를 파악하기 위하여 일련의 2차원 진단 영상들을 공간적으로 구성하여 입체적 영상을 생성하고, 이동, 회전, 확대/축소, 컬러링과 같은 다양한 조작 기능을 제공한다. 본 개발 시스템은 원격 수술 시뮬레이션을 위하여 클라이언트-서버 구조로 이루어졌으며, 시스템 간 사용되는 메시지 처리를 위한 진단 제어 관리기, 족부별 가시화 및 조작을 위한 수술 시뮬레이션 관리기, 원격 사용을 위한 통신망 제어기, 그리고 각종 환자 정보를 위한 데이터베이스 관리기로 구성된다. 또한 범용의 데스크탑 컴퓨터 상에서 사용자 인터페이스를 통하여 서버에 접속하여 진단보조시스템을 사용함으로써 보다 많은 사용자들이 동시에 사용할 수 있는 이점이 있다.

  • PDF

Development and Performance Tests of the Bridge-Transported Servo Manipulator System for Remote Maintenance Jobs in a Hotcell

  • Jin Jaehyun;Park Byungsuk;Ko Byungseung;Yoon Jisup;Jung Ki-Jung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.3
    • /
    • pp.257-268
    • /
    • 2005
  • In this paper, a prototype of the Bridge-Transported Servo Manipulator (BTSM) system is introduced, which has been developed to do operation and maintenance jobs remotely in a hot cell. The system consists of a telescopic transporter, a slave arm, a master arm, and a control system. Several tests such as a positional tracking, a weight handling, reliability, and operability have been performed and test results are presented. Based on the test results, an upgraded system which will be used during demonstrations of the advanced spent fuel conditioning process (ACP) has been designed.

  • PDF

연구용원자로에서 조사된 캡슐 및 핵연료다발 해체용 갭슐절단기 개발

  • 박대규;주용선;안상복;이기순;강영환
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.503-508
    • /
    • 1998
  • 연구용원자로인 하나로(HANARO)에서 중성자 조사된 캡슐 및 핵연료다발을 절단 및 해체하기 위한 장비인 캡슐절단기를 개발하여 조사재시험시설(IMEF)의 M2 핫셀(hot cell)에 설치하였다. 재료 및 핵연료의 개발을 위해 하나로에서 조사되는 캡슐 및 핵연료다발의 절단 및 해체는 핵연료봉 및 캡슐내부에 내장되어 있는 시편에 손상 및 결함이 발생하지 않도록 하는 것이 매우 중요하며, 이러한 장비는 핫셀의 작업구역에서 원격조작기를 사용하여 원격으로 조작이 용이하도록 설계 및 제작되어야 한다. 이에 조사재시험시설에서 개발한 캡슐절단기는 가공물이 회전 및 좌우이송, 절단용 철이 회전 및 전후이송이 각각 되도록 하였고, 핫셀내에 설치하기 전에 가공에 필요한 최적의 조건을 설정하였다. 그리고 핫셀내 설치후 중성자에 조사되지 않은 하나로용 핵연료다발과 조사된 무계장캡슐을 건식상태로 절단 및 해체하여 장비 성능을 확인하였다.

  • PDF