• Title/Summary/Keyword: 원거리 초음파검사

Search Result 14, Processing Time 0.022 seconds

A Software Approach for the Realtime Received Signal Processing in Magnetostrictive Long-Range Ultrasonic Testing (자왜형 원거리 초음파검사에서 실시간 수신신호 처리를 위한 소프트웨어 접근)

  • Heo, Won Nyoung;Lim, Hyung Taik;Kim, Tae Gyung;Choi, Myoung Seon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.540-544
    • /
    • 2012
  • Like the phase array based ultrasonic system, complicated electronics has been used for real time signal processing in the magnetostrictive long-range ultrasonic testing(LRUT) system. This study shows that the software approach including the phase compensation, noise filtering and waveform transformation takes advantage rather than the previous hardware approach. Furthermore, it is possible for the software approach to be able more flexible and efficient realtime signal processing. These results will contribute to a cost-effective LRUT system and analysis of the inspection data.

Realtime Identification of the Propagation Direction of Received Echoes in Long-Range Ultrasonic Testing (원거리 초음파검사에서 수신에코 진행방향의 실시간 식별)

  • Choi, Myoung Seon;Heo, Won Nyoung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.69-72
    • /
    • 2013
  • In long-range ultrasonic testing, a phased array probe composed of multiple identical transducers with an uniform interval of one quarter wavelength is usually used for the transmission or reception directivity control. This paper shows that the propagation directions of individual echoes can be identified in real time by displaying the inputs of a process for summing the constitution reception signals after compensating the phase difference due to the transducer interval, together with the output of the process. A constructive interference of the constitution echoes indicates a forward direction echo propagating along an intended direction while a destructive interference implies a reverse direction echo propagating along the direction opposite to the intended one.

Spiral Coil Magnetostrictive Strip Transducers for Long Range Ultrasonic Testing of Cylindrical Structures (실린더형 구조물의 원거리 초음파검사용 나선형 코일 자왜 스트립 변환기)

  • Heo, Won-Nyoung;Choi, Myoung-Seon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.5
    • /
    • pp.416-420
    • /
    • 2008
  • In EMAT field, spiral RF coils are much more widely used when compared with solenoid coils. In the field of the magnetostrictive strip transducers for long range ultrasonic testing of cylindrical structures, however, solenoid coils has been used. This seems to be attributed to the difficulty in fabricating low frequency (i.e., large size) spiral coils. In this paper, we describe a method for fabricating spiral coil magnetostrictive strip guided wave transducers from FFC (flexible flat cable). It is demonstrated through a comparison experiment that the spiral coil transducer has much superior performance (sensitivity, SNR, and guided wave direction control capability) than the previous transducer with solenoid coils.

Single Layer Array of Transmitting and Receiving Spiral Coils for Magnetostrictive Type Long-Range Ultrasonic Testing (자왜방식 원거리 초음파검사를 위한 단층 송수신 나선형 코일 배열)

  • Choi, Myoung Seon;Kim, Yoo Jin;Lee, Hyo Moon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.219-225
    • /
    • 2013
  • Separate and layered transmitting and receiving spiral coil arrays had been used for the optimized individual applications of magnetostrictive type long-range ultrasonic testing. In this study, it was demonstrated that when taking advantages of the spiral coils with the leg width reduced to be half of the previous one and of the empty spaces due to the decrease of leg width, the transmitting and receiving coil array can be arranged to form a single layer structure allowing more easy use and fabrication. Because of the number of turns of the receiving coils that is proportional to their leg width, the sensitivity of the single layer coil array was about half that of the corresponding double layer coil array while it allowed the receiving amplifier to get faster recovery from a saturation due to the main bang echo. It was also found that the two types of coil arrays have almost the same performances in the view points of signal-to-noise ratio and directivity control.

Magnetic Property Effects of the Strip on Transducer Sensitivity in a Magnetostrictive Strip Type Guided Wave Transducer (자왜 스트립 도파변환기에서 스트립의 자기적 특성이 변환기 감도에 미치는 영향)

  • Kim, Sung-Joon;Choi, Myoung-Seon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.205-210
    • /
    • 2008
  • Magnetic hysteresis loops of a nickel strip and a Fe-Co alloy strip, which have been used in magnetostrictive strip type guided wave transducers for long range ultrasonic testing of pipelines, were measured and then magnetic property effects of a strip on transducer sensitivity were analyzed. The sensitivity of an optimized Fe-Co strip transducer was superior to that of the nickel strip transducer by a factor of about 30. It was shown that this was mainly attributed to the differences in remanence magnetization and coercivity of the two magnetostrictive materials.

A Study on Techniques for Focusing Circumferential Array Guided Waves for Long Range Inspection of Pipes (배관 원거리 진단을 위한 원주방향 배열 유도초음파 집속기술 개발)

  • Kang, To;Kim, Hak-Joon;Song, Sung-Jin;Cho, Young-Do;Lee, Dong-Hoon;Cho, Hyun-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.114-121
    • /
    • 2009
  • Ultrasonic guided waves have been widely utilized for long range inspection of structures. Especially, development of array guided waves techniques and its application for long range gas pipe lines(length of from hundreds meters to few km) were getting increased. In this study, focusing algorithm for array guided waves was developed in order to improve long range inspectability and accuracy of the array guided waves techniques for long range inspection of gas pipes, and performance of the developed techniques was verified by experiments using the developed array guided wave system. As a result, S/N ratio of array guided wave signals obtained with the focusing algorithm was increased higher than that of signals without focusing algorithm.

The Study on Scattered Far-Field Analysis of Ultrasonic SH-Wave Using Boundary Element Method (경계요소법을 이용한 SH형 초음파 원거리 산란장 해석에 관한 연구)

  • Lee, Joon-Hyun;Lee, Seo-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.5
    • /
    • pp.333-339
    • /
    • 1999
  • It is well recognized that ultrasonic technique is one of the most common and reliable nondestructive evaluation techniques for quantitative estimation of defects in structures. For the quantitative and accurate estimation of internal defects. the characteristics of scattered ultrasonic wavefields must be understood. In this study. the scattered near-field and far-field due to a circular cavity embedded in infinite media subjected to incident SH-waves were calculated by the boundary element method. The frequency response of the scattered ultrasonic far-field was transformed into the time-domain signal by obtaining its inverse Fourier transform. It was found that the amplitude of time-domain signal decreases and its time delay increases as the distance between the detecting point of ultrasonic scattered field and the center of internal cavity increases.

  • PDF

Evaluation of Near/Far Field and Directivity of Ultrasonic Transducer for Turbine Rotor Disc (터빈 로타 디스크의 초음파탐상을 위한 초음파탐촉자의 지향성 및 탐상범위)

  • Won, S.H.;Chang, H.K.;Cho, K.S.;Lee, J.O.;Lee, J.K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.3
    • /
    • pp.163-171
    • /
    • 1998
  • Near/far field length and directivity of transducers were investigated for the improvement and evaluation of the detectability of flaws in a disc. The reference block is fabricated for the disc of stage 6 in Yonggwang unit 1. The near/far field and directivity of an ultrasonic transducer with the center frequency of 5MHz were calculated for the inspection of the disc. These values showed good agreements with the experimental results. In the system composed of a wedge and a disc, those are evaluated theoretically and experimentally for the specimen with the artificial flaws of the size 2mm and 4mm and an ultrasonic transducer with the center frequency 5MHz and diameter 0.5inch. The detectability of keyway-flaw and detectable region for inspection were evaluated by using both tangential $45^{\circ}$ and $90^{\circ}$ transducers located at the distance of 53mm and 75mm from the disc hub, respectively.

  • PDF

Assessment of Pipe Wall Loss Using Guided Wave Testing (유도초음파기술을 이용한 배관 감육 평가)

  • Joo, Kyung-Mun;Jin, Seuk-Hong;Moon, Yong-Sig
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.295-301
    • /
    • 2010
  • Flow accelerated corrosion(FAC) of carbon steel pipes in nuclear power plants has been known as one of the major degradation mechanisms. It could have bad influence on the plant reliability and safety. Also detection of FAC is a significant cost to the nuclear power plant because of the need to remove and replace insulation. Recently, the interest of the guided wave testing(GWT) has grown because it allows long range inspection without removing insulation of the pipe except at the probe position. If GWT can be applied to detection of FAC damages, it will can significantly reduce the cost for the inspection of the pipes. The objective of this study was to determine the capability of GWT to identify location of FAC damages. In this paper, three kinds of techniques were used to measure the amplitude ratio between the first and the second welds at the elbow area of mock-ups that contain real FAC damages. As a result, optimal inspection technique and minimum detectability to detect FAC damages drew a conclusion.

Analysis of Ultrasonic Scattering from Side-drilled Holes (원주형 기공에 대한 초음파 산란 해석)

  • Jeong, Hyun-Jo;Park, Moon-Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.6
    • /
    • pp.559-565
    • /
    • 2004
  • Two different methods were used for the scattering analysis of side-drilled holes(SDH). The scattering models include an explicit model based on the Kirchhoff approximation and the solution of the exact separation of variables. The far-field scattering amplitude was calculated and their time-domain results were compared for the case of shear vertical wave. The exact solution predicts the existence of the creeping wave. The Kirchhoff approximation agreed to the exact solution, except the case of the creeping wave. Two measurement models were introduced to predict the response from the SDHs for the case of immersion, pulse-echo testing. The received voltage was calculated for the case of the shear vertical waves with the incident angle of $45^{\circ}$ to the SDH with the diameter of 1mm, and compared with the experimental results.