• Title/Summary/Keyword: 운전 모드

Search Result 418, Processing Time 0.033 seconds

A Case Study on Improving for Operating ATC/ATO System and Driving Environment Using FMECA (FMECA를 활용한 ATC/ATO 시스템 및 운전환경 개선 사례연구)

  • Kim, Hanyoung;Lee, Jinchoon
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.550-557
    • /
    • 2012
  • In general, FMECA is a technique for identifying failure modes and devices which could result in fatal outcomes. Also it can be used in design or in maintenance through establishing priorities. The purpose of this paper is aimed at improving the driving conditions in advance through analyzing the operation failure phenomena quantitatively with FMECA analysis on the onboard signal system equipped with ATC/ATO, and through deriving the risk factors. This paper suggests an alternative solution for improving the performance of ADU by analyzing a case with FMECA.

신뢰도 기반 정비를 위한 기기 고장 데이터 분석

  • 정현종;최광희;김영호;홍승열
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.252-257
    • /
    • 1998
  • 국내 원전에 신뢰도 기반 정비(RCM : Reliability Centered Maintenance) 기법을 도입하기 위해 수행하고 있는 영광 1,2호기 시법계통 RCM 분석에서 관련 기기의 고장데이터를 RCM 분석 방법론에 따라 분석하였다. 본 논문에서는 작업의뢰서와 작업보고서 기록내용을 토대로 지배적인 고장모드 및 다빈도 고장발생 기기를 파악하여 고장원인을 분석하였으며, 기기 유형으로 분류하여 고장들을 분석하였다. 분석결과 지배적인 고장모드는 EPRI에서 분류한 고장모드에 모두 포함되었으며, 고장빈도가 높은 기기의 고장원인은 운전환경, 사용유체, 운전형태, 기기 형식 등에 따라 고장메커니즘이 다르게 나타나는 것으로 분석되었다. 기기 유형으로 분류하여 고장모드별로 고장율을 분석한 결과 미국의 Generic Data(IEEE Std 500-1984)와 근소한 차이를 보이거나 약간 낮은 것으로 분석되었으며, 고장율이 높은 기기 유형을 단위 기기별로 세분화하여 분석한 결과 공기구동 조절벨브의 외부누설 고장율은 1.10E-06 이지만 충전유량 조절밸브의 고장율은 1.70E-05로서 약 10배 정도로 고장율이 높은 것으로 분석되었다. 기기별로 세분화한 고장을 분석 결과는 시범계통 RCM 분석시 고장모드 영향분석(FMEA. Failure Mode and Effective Analysis) 단계에서 필수기기를 선정하는 하나의 인자로 활용하였으며, 고장율의 역수로 구한 고장간 평균시간(MTBF:Mean Time Between Failure)은 정비주기 선정시 기초데이터로 활용된다.

  • PDF

Introduction and Demonstration of 1 MVA STATCOM (1 MVA STATCOM의 실증운전 사례소개)

  • Lee, Doo-Young;Jung, Hong-Ju;Kim, June-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.524-525
    • /
    • 2013
  • (주)효성에서는 FACTS(Flexible AC Transmission System) 기기 중 하나인 1 MVA STATCOM(Static synchronous Compensator)을 개발하여 제주 행원의 풍력단지에 설치하였으며, 이에 대한 실증운전 및 시험을 완료하였다. STATCOM은 연계된 전력계통의 상황에 맞게 일정전압 제어 및 무효전력 제어모드로 운전되며, 이를 이용하여 계통전압의 안정화에 기여함으로써 전력품질을 향상시키는 역할을 한다. 본 논문에서는 1 MVA STATCOM의 실증운전을 통해 전력품 질향상 사례를 분석하였다.

  • PDF

A Seamless Mode Transfer Scheme for ESSs (에너지저장시스템에서 매끄러운 모드절환을 위한 동작알고리즘 연구)

  • Byen, Byeng Joo;Seo, H.U.;Joe, Y.H.;Kim, D.J.;Choe, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.425-426
    • /
    • 2013
  • 본 논문에서는 에너지저장시스템에서 계통연계모드와 독립운전 모드사이를 절환하는 부분에 있어 매끄러운 모드 절환을 위한 동작알고리즘에 대하여 연구하였다. 이는 Psim 9.0을 사용한 시뮬레이션과 실험을 통하여 검증되었다.

  • PDF

Experimental and Numerical Studies on Heat/Smoke Behavior due to a Fire on Underground Subway Platform (I) - Experimental Approach - (지하철 역사 승강장 화재발생시 열/연기 거동 분석을 위한 실험 및 수치 연구(I) - 실험적 접근 -)

  • Park, Won-Hee;Kim, Dong-Hyeon;Chang, Hee-Chul;Kim, Tae-Kuk
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.9-14
    • /
    • 2006
  • In this study boundary velocity which is one of the important boundary conditions for numerical simulation for subway station on fire are experimentally obtained. The tests were conducted according to its operating mode of the ventilation systems in the platform: smoke extraction ventilation mode in occurrence of fire and normal ventilation mode for air conditioning. Velocities are measured at various points on the platform. To examine smoke extraction and air supply capacity in the platform level, air velocities were checked on opening vents. Numerical analysis under normal ventilation mode without fire is conducted by using measured boundary conditions, and the numerical results are compared with the measured velocities on the platform.

Analysis of Nuclear Power Plant Load Follow Operation by Temperature Reduction Method (냉각재 온도 감소 장식에 의한 원자력발전소 부하 추종 운전 해석)

  • Park, Sang-Yoon;Park, Goon-Cherl;Lee, Un-Cherl;Kang, Chang-Sun;Kim, Chang-Hyo;Chung, Chang-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.209-217
    • /
    • 1986
  • The inlet coolant temperature reduction technique has been used to extend the load follow operation further in the end-of-cycle-life(EOL). In order to simulate the technique and calculate the nuclear characteristics of a PWR core according to the load follow operation, the three dimensional computing system has been established. The analysis was performed in both MINB and SPINR modes of typical 12-3-6-3 locad follow operation for the EOL of KNU-1 plant. Moreover, the capability of return-to-power has been also tested for those two modes with the system analysis by the RETRAN-02 code. The results show that it has no difficulty to extend the load follow operation further in the EOL by applying the inlet coolant temprature reduction, and also the spinning reserve capacity(SRC) increases by 13% in MINB mode and 14% in SPINR mode Bore that used by control rods only, for 14$^{\circ}$ F drop in the inlet temperature.

  • PDF

Comparison of Selective Removal of Nitrate Ion in Constant Voltage and Constant Current Operation in Capacitive Deionization (축전식 탈염에서 정전압과 정전류 운전에 따른 질산 이온의 선택적 제거율 비교)

  • Choi, Jae-Hwan;Kim, Hyun-Ki
    • Korean Chemical Engineering Research
    • /
    • v.53 no.3
    • /
    • pp.269-275
    • /
    • 2015
  • The adsorption characteristics of ions were evaluated for the nitrate-selective carbon electrode (NSCE) in accordance with power supply methods. The NSCE was fabricated by coating the surface of a carbon electrode with anion-exchange resin powders with high selectivity for the nitrate ion. Capacitive deionization (CDI) experiments were performed on a mixed solution of nitrate and chloride ion in constant voltage (CV) and constant current (CC) modes. The number of total adsorbed ions in CV mode was 15% greater than that in CC mode. The mole fraction of adsorbed nitrate ion showed the maximum 58%, though the mole fraction was 26% in the mixed solution. This indicates that the fabricated NSCE is highly effective for the selective adsorption of nitrate ions. The mole fraction of adsorbed nitrate was nearly constant value of 55-58% during the adsorption period in CC mode. In the case of CV mode, however, the values increased from the initial 30% to 58% at the end of adsorption. We confirmed that the current supplied to cell is important factor to determine the selective removal of nitrate.

Improve Operating Performance of the High Speed SRM using Advanced 4-Level Converter (개선된 4-Level 컨버터를 이용한 고속 SRM의 운전성능 개선)

  • Lee, Jong-Heon;Kim, Heon-Kon;Ahn, Jin-Woo;Lee, Dong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1095-1096
    • /
    • 2011
  • 본 논문은 고속 SRM의 운전 개선을 위한 4-Level 컨버터를 제안한다. 제안된 컨버터는 비대칭 컨버터에 비하여 고속에서의 운전 성능을 개선하고, 추가적인 전원장치 없이 환류 구간에서 환류 되는 에너지를 부스트 커패시터에 충전하여 이를 감자 구간에 활용함으로서 감자 구산에서 감자 시간을 줄여 여자 되지 않는 상에서 발생하는 Tail 전류가 여자 되는 상에 미치는 영향을 최소화 하였다. 또한 각 독작 모드에 따른 전류제어 모드를 선택함으로써, 4-Level 컨버터에 적합한 전류제어기를 제안하였다.

  • PDF

A Study on Operation Mode Development for Construction of Flue Gas Desulfurization System in Thermal Power Plants (화력발전소 탈황설비 설치를위한 운전모드 개발에 관한 연구)

  • 문채주;장영학;김의선
    • Journal of Energy Engineering
    • /
    • v.9 no.1
    • /
    • pp.10-18
    • /
    • 2000
  • 기존 화력발전소에 탈황설비가 추가되고, 이로 인하여 새로운 계통의 통풍저항을 상쇄시키기위하여 기존의 유인통풍기와 탈황설비 사이에 승압통풍기가 설치되고 있다 통풍저항의 증가와 새로운 통풍기의 추가는 기존 통풍특성의 변화를 나타낼것이고 , 빈번한 발저소 정지를 가져오는 심한 노내 압력변동을 보이게 될 것이다. 따라서 , 발전소를 안전하게 운전하기 위해서는 설계된 통풍계통을 기반으로 한 교정된 운전모드에 관한 지식이 요구된다. 본 논문에서는 MMS (Modular Modeling System) 소프트웨어를 사용하여 우회 댐퍼의 개방을 수반하는 유인 및 승압통풍기의 비상정지의 사례에 따른 화력발전소 노내 압력, 통풍기의 압력과 유량, 댐퍼의 개도등과 같은 해석결과를 제시하고 논의하고 있다.

  • PDF

Parallel Operation of Grid-connected Inverters with Seamless transfer for Energy Storage System (에너지저장시스템을 위한 무순단 절체 기능을 갖는 계통연계형 인버터의 병렬운전)

  • Jung, Ahjin;Kim, Jooha;Prabowo, Yos;Choi, Sewan
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.343-344
    • /
    • 2014
  • 마이크로그리드에서 ESS용 PCS를 모듈화하면 용량의 확장성, 신뢰성 향상 등의 장점을 갖는다. 모듈화 된 인버터는 병렬구조를 갖고 인버터 모듈간의 접속점(PCC)에 공통으로 중요부하를 공유하고 있어 독립운전 시 정확한 부하분담이 요구된다. 또한 독립운전 및 계통연계 모드전환 시 제어기 변동으로 인한 과도상태로 인해 접속점에 연결된 중요부하에 악영향을 끼칠 수 있다. 따라서 본 논문에서는 ESS용 PCS로서 모듈화 된 병렬 인버터가 모드전환 시 과도상태가 없는 무순단 절체 기능을 갖는 마스터-슬레이브 제어알고리즘을 제안한다.

  • PDF