• Title/Summary/Keyword: 운전 모드

Search Result 418, Processing Time 0.024 seconds

Modeling and Evaluation of Slip-Mode Frequency Shift Method for Anti-islanding Method (슬립모드 방식을 이용한 단독운전 검출기법의 모델링과 평가)

  • Yu, Byung-Gyu;Jung, Young-Seok;So, Jung-Hun;Yu, Gwon-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.520-522
    • /
    • 2005
  • Islanding phenomenon is undesirable because it lead to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized reclosure. In order to prevent this phenomenon, various anti-islanding methods have been studied. Even though the slip mode frequency shift (SMS) method has been regarded as a highly effective anti-islanding method, the analytical design method of that was not cleared. This paper proposes a modeling of the SMS method using non-detection zone (NDZ) and evaluation of the method according to the test conditions of IEEE Std. 929-2000. The SMS method is derived analytically through the modeling and verified visually by simulation and experiment.

  • PDF

Design and Implementation of the Bidirectional DC-DC Charger for FTP-95 test verification of EV vehicles (EV 자동차의 FTP-75 운전 검증을 위한 양방향 DC-DC 충전기 설계 및 구현)

  • Park, Ilkyu;Kim, Daesik;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.453-454
    • /
    • 2013
  • 본 논문은 EV(Electric Vehicle) 자동차에 사용되는 배터리의 충/방전 전류에 따른 SOC (State of Charge) 및 전압특성을 시뮬레이션으로 구현 및 검증하기 위하여, 양방향 DC-DC 컨버터를 설계 및 구현을 하였다. 실험을 통해 EV 자동차의 도심 주행 모드(FTP-75) 충/방전 전류 패턴을 재현 하였다. 제어기법으로는 PI전류 제어를 사용 하였으며, 배터리 전류 리플을 최소화하기 위하여 L-C-L필터를 사용 하였다.

  • PDF

Development of 3kW Smart Home Energy Server System (3kW급 스마트 홈에너지 서버 시스템 개발)

  • Kim, Minjae;Jung, Ahjin;Yang, Daeki;Hong, Seokyong;Choi, Sewan;Cho, Junseok
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.530-531
    • /
    • 2013
  • 본 논문에서는 비상전원 기능을 갖는 고효율, 고신뢰성의 3kW급 스마트 홈에너지 서버 시스템을 제안한다. 제안하는 시스템은 Li-Ion 배터리 충 방전용 양방향 컨버터, 태양광 발전용 단방향 컨버터, 양방향 계통 연계형 인버터로 구성되어 있다. 제안하는 시스템의 운전모드를 제시하고 3kW급 시작품의 실험을 통하여 타당성을 검증하였다.

  • PDF

Linux Real Time Control Thread Design for the ITER PF/CS MRC

  • Suh, J.H.;Oh, J.S.;SONG, Inho;Yoo, M.H.
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.128-129
    • /
    • 2019
  • ITER AC/DC Converter는 플라즈마 운전에서 기능적인 역할과 동작 모드에 따라 PF/CS, TF, CC Plant로 구분되어 동작하며 PF, CS, VS1 컨버터는 플라즈마 전류 발생, 증감, 형상제어, 위치제어를 하며 PCS(Plasma Control System), MRC(Master Controller)에 의해 제어된다. MRC는 상위 제어인 PCS와 LCC(Local Control Cubicle)의 Middle Ware Layer에서 여러 Linux Machine들과 복잡한 통신망으로 연결되어 초전도 코일 전류 Driver에 있어서 Control과 Soft Down을 위한 Real Time 제어 기능을 한다. 본 논문은 이러한 제어를 구현하기 위한 Linux Real Time Control Thread Design의 구성과 결과를 논의하고자 한다.

  • PDF

A Study on the Selection of Train Operationg Mode Minimizing the Running Energy Consumption (전동열차 운행에너지를 최소화 하는 운전모드 결정)

  • Kim, Yong-Hyun;Kim, Dong-Hwan;Kim, Chi-Tae
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.119-124
    • /
    • 2005
  • Decision of operation performance mode to minimize the energy consumption of urban rail vehicle. This paper analyses how much acceleration and deceleration of urban rail vehicle should be applied andhow to choose an operation mode to minimize energy consumption when train runs between station within the fixed operation time. The decided operation pattern satisfying the minimum energy consumption becomes a target trajectory and a basis for the controller design criteria. To make this goal it grasps the characteristics of urban rail vehicle, realize operation energy model of urban rail vehicle and verify the accuracy of embodied model the Matlab simulation with the same operation result of real route. It searches for operation pattern to minimize operation energy by changing the acceleration and deceleration on the imaginative route and proposes operation pattern minimizing energy consumption by applying real operation data between Dolgogee-Sukgye section of Seoul Metropolitan Subway Line 6.

  • PDF

A Study on the Operating-Mode Characteristics of Two-Module Thyristor Controlled Series Compensator (Two-Module TCSC의 운전모드 특성 연구)

  • Jeong, Gyo-Beom
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.11
    • /
    • pp.1410-1416
    • /
    • 1999
  • This paper aims at investigating the operating-mode characteristics of two-module Thyristor Controlled Series Compensator (TCSC) as an equivalent of the multi-module TCSC in a simple three-phase power transmission system. The load flow program is developed to analyze the steady-state characteristics of two-module TCSC system and to find the thyristor firing angles for the required real power flow. The stability calculation program is developed with Poincare mapping theory. Simulation studies of the TCSC power transmission system using EMTP are performed to evaluate the transient characteristics of two-module TCSC as a real power flow controller and to rpove the results of the load flow calculation and the stability analysis. In the process of the study, the operating-mode characteristics of two-module TCSC are evaluated and compared to those of single-module TCSC.

  • PDF

A Novel Frequency Tracker for Islanded-Mode Operation in Microgrid (마이크로그리드 독립운전모드를 위한 주파수 추종에 관한 연구)

  • Jeon, Jin-Hong;Kim, Kyoung-Hoon;Hwang, Chul-Sang;Kim, Jang-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1331-1338
    • /
    • 2011
  • This paper proposes a method for frequency control of islanded microgrid with battery energy storage system. For frequency control of islanded microgrid, battery energy storage system uses a phase locked loop algorithm with positive sequence components for a fast frequency estimation. Microgrid is a power system with small inertia because it has small capacity generators and inverter systems for renewable energy. So, Islanded microgrid's frequency varies fast and large as small generation and load changes. To reduce frequency variation of islanded microgrid, it needs a device with fast frequency response. For fast frequency response, a fast frequency tracking is important. To show the validation of proposed fast frequency tracking algorithm, battery energy storage system with proposed algorithm is tested in microgrid pilot plant.

Fabrication and Operation Characteristics of Linear Ultrasonic Motor (L$_1$-B$_4$모드 선형 초음파 전동기의 제작과 운전 특성)

  • 이명훈;김진수
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.6
    • /
    • pp.257-262
    • /
    • 2001
  • In this paper, a linear ultrasonic motor using piezoelectric ceramics was fabricated, and its operation characteristics were investigated. A linear ultrasonic motor using L$_1$-B$_4$model was composed of a stator and a rotor, and a stator was composed of piezoelectric ceramics and a elastic body. When applied frequency and voltage were 58.4kHz and 56V respectively, the feeding speed of the motor was 19.8 cm/s. A linear ultrasonic motor could be moved in left and right directions by the phase difference. Feeding speed and feeding force of a linear ultrasonic motor could be controlled by applied voltage. A linear ultrasonic motor had a droping torque-speed characteristic. The maximum efficiency of linear ultrasonic motor was 2.14%. Therefore, this linear ultrasonic motor can be expected to be used for a card-forwarding device, such as a card reader device and so on.

  • PDF

A Study on the Switching Algorithm for IPMSM Speed Control in Railway Vehicle (철도 차량 구동용 IPMSM 속도 제어를 위한 스위칭 알고리즘 연구)

  • Kang, Seong-Yun;Lee, Chang-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.286-287
    • /
    • 2017
  • 본 논문은 철도 차량 구동용 IPMSM 제어를 위한 속도 영역별 PWM 알고리즘을 제안한다. 철도 차량의 고속영역 제어는 인버터 전압 이용률을 최대화 할 수 있는 1-Pulse 제어 기법이 요구된다. 그러나, SPWM을 이용한 비동기 1-Pulse 제어는 출력 전류의 불균형을 초래한다. 따라서, 고속영역 제어를 위해 동기화 시킨 후 SPWM을 이용한 1-pluse 제어는 필수적이다. 본 논문에서는 비동기 모드로 제어를 시작하여 과변조 영역 이전에 지령 전압과 삼각파 주파수를 동기화 시킨 후 고속 영역운전을 하는 PWM 알고리즘을 제안한다. 본 논문에서 제안하는 알고리즘은 시뮬레이션으로 검증한다.

  • PDF

ReBCO Pancake Coil in Persistent Current Mode (영구전류 모드 운전을 위한 ReBCO 팬케이크 권선)

  • Kim, Y.I.;Kim, W.S.;Lee, S.Y.;Park, S.H.;Choi, K.
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.12-14
    • /
    • 2009
  • 초전도 DC 마그네트에 영구전류 (Persistent Current)를 흘리기 위해서는 초전도 접합(Superconducting Joint)이 필요하다. 저온 초전도 선재는 초전도 접합이 가능하며 고온 초전도체 중 BSCCO 선재로도 초전도 접합을 만들 수 있다. 그러나 최근 개발되어 향후의 초전도기기에 적용될 2세대 초전도 선재인 ReBCO CC(Coated Conductor)로는 아직 초전도 접합을 만들 수 없다. 본 연구에서는 광폭 선재의 중심을 가르고 양 종단부가 그대로 붙여진 형태의 선재를 이용하여 영구전류를 홀릴 수 있는 고온 초전도 마그네트를 제작하였다. 영구전류 초기 충전을 위하여 1.2 m 길이의 ReBCO 도체 종단부에 스테인리스 히터를 부착하여 영구전류 스위치를 구성하였다. 발생된 자기장의 시간적 균일성을 측정하기 위하여 34 시간동안 홀센서를 사용하여 대기압 액체질소 77.3 K에서 자기장을 측정하였다.

  • PDF