• Title/Summary/Keyword: 운전범위

Search Result 531, Processing Time 0.027 seconds

Performance of Rotating Biological Contactor under Various Hydraulic Residence Time on thle Removal of Total Ammonia Nitrogen and COD in a Simnulated Water Recirculating System (모의 순환여과식 실험장치에서 회전원판반응기 (RBC)에 의한 순환수처리)

  • SUH Kuen-Hack;KIM Byong-Jin;LIM Sung-Il;CHO Jin-Koo;KIM Yong-Ha;OH Chang-Sup
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.2
    • /
    • pp.180-185
    • /
    • 1999
  • Rotating Biological Contactor (RBC) was tested for the treatment of artificial rearing water in n simulated aquaculture system. Performance of RBC on the removal of TAN and COD was evaluated by controlling hydraulic residence time (HRT). As HRT of RBC was increased, TAN removal rate ana removal efficiency of RBC and TAN concentration of rearing water were increased, but COD removal rate was decreased. Total alkalinity consumption rate was increased by increasing HRT of RBC. Ratio between total alkalinity consumption rate and TAN removal rate was 7.73. HRT for maintaining lowest TAN and COD concentration of artificial rearing water was 14,6 minutes and at that condition TAN and COD concentration of the water was 1.28 and $5.59 g/m^3$, respectively.

  • PDF

The Grounding Method Application of Power Plant Simulator (발전소 시뮬레이션시스템 접지방식 연구를 위한 타시스템 접지방식 분석)

  • 오영일
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1999.10a
    • /
    • pp.70-74
    • /
    • 1999
  • 발전소 시뮬레이션 시스템 기술은 종합적인 지식을 바탕으로 자료수집 및 분석, 소프트웨어 개발 환경, 수학적 모델, 전산기 구성, 각종 계기류 설계 및 구매 장착 등의 노하우를 알아야만 제작할 수 있는 종합적인 기술이다. 또 지시기반의 기술이며 부가가치가 높은 기술이기 때문에 선진 각국에서는 계측제어 시스템의 기술개발 및 시장 확대를 위하여 힘을 쓰는 동시에 타국으로의 기술정보 유출을 경계하는데 신경을 곤두세우고 있다. 현재 복잡화되어 가고 있는 산업 사회의 전력 수요에 대한 대폭적인 증가 추세에 따라 발전소에서는 보다 효율적이며 합리적이고 경제적인 전력 공급을 위해서 전력 생산에 대한 신뢰성 향상 및 안정성 확보는 물론, 효율성 높은 운전이 절실히 요구되고 있다. 한편, 국내의 시뮬레이션 시스템 분야 기술은 아직도 완벽한 수준에는 미치지 못하며, 이 분야의 기술력 확보 및 신기술 개발은 향후 미래의 모든 시스템산업의 성쇄를 판가름하는 아주 중요한 척도가 될 것이다. 이 중에서 접지 분야는 고전압 혼촉에 의한 저압측 선로의 전압상승 방지, 모선(Bus)이나 전력 기기의 절연보호 및 회로전압의 안정등으로 시스템 성능을 한층 증가 시켜줄 뿐아니라 기기의 오동작이나 낙뇌등으로 인명피해 발생을 없애주는 아주 중요한 분야임에도 불구하고 이 분야의 국내 관련법규등이 미비한 사항이다. 그래서 발전소 분산제어 시스템분야의 장기간 신뢰성 및 안정성을 가지고 있고, 국내에서 많이 사용하는 미국 Bailey의 infi-90 및 독일 ABB의 Procontrol-P를 비교 분석하여 발전소 시뮬레이션 시스템의 접지에 응용 하고져 한다.상호 발생기를 이용한 다양한 시스템 검증 및 분석에 이용할 수 있을 것이다. 본 논문은 가상호 발생기의 구조와 최대 용량 시험 방법을 소개하고, 더 나아가 호 Traffic에 대한 최대 용량 시험뿐 아니라 QoS를 향상시키기 위한 교환 시스템의 제반 성능 시험 및 분석에 이를 이용하기 위해 개선이 필요함을 서술하고자 한다.textrm{m}$~3.4$\mu\textrm{m}$ 범위에서의 투과 및 흡수 스펙트럼을 측정하였다. 결정 성장 결과 B3+, Er3+, Cr3+ 이온은 Ti4+ 이온과 이온의 크기 차이가 심하여 결정의 정상적인 성장을 방해하는 물성을 나타냈고, V5+, Cr3+ 이온은 흑색의 결정, Fe3+ 이온은 적갈색의 결정으로 성장되었다. Al3+, Zr4+, Al3+의 순서로 투과도가 높아지는 것이 관찰되었다. 불순이온의 농도에 따른 영향으로서 Al3+ 이온의 경우 주입농도가 높아질수록 low angle boundary와 oxygen deficiency가 감소하였고, 투과율은 조금 감소하거나 큰 차이가 없는 것으로 나타났다. 반면에 Cr3+ 이온을 주입한 경우 0.003 atomic%에서 최적의 물성을 보였으며, 주입농도가 높아질수록 결정성장이 어려워지고 광의 투과도가 급격히 저하되었다.은 1.3을 나타내었다.로 보인다.하면 수평축과 수직축의 분산 장벽의 비에 따라 cluster의 두께비가 달라지는 성장을 볼 수 있었고, 한 축 방향으로의 팔 넓이는 fcc(100) 표면의 경우 동일한 Ed+Ep값에 대응하는 팔 넓이와 거의 동일한 결과가 나타나는 것을 볼 수 있다. 따라서 이러한 비대칭적인

  • PDF

Study on Pyrolysis Characteristics for Upgrading of Bitumen-Like Heavy Oil Contained in Indonesian Resources (인도네시아산 자원 내에 포함된 역청성 오일의 경질화를 위한 열분해 특성에 관한 연구)

  • Jang, Jung Hee;Han, Gi Bo;Park, Cheon-kyu;Jeon, Cheol-Hwan;Kim, Jae-Kon;Kwak, Hyun
    • Clean Technology
    • /
    • v.22 no.4
    • /
    • pp.292-298
    • /
    • 2016
  • In this study, the pyrolysis process was carried out in order to upgrade of heavy oil contained in the resources from Indonesia. In order to investigate the composition and basic properties of the heavy oil contained in the resources, the various analytical methods was used and then the TGA (thermogravimetric) method was especially used for the thermal degradation characteristics of heavy oil in the pyrolysis. From the results obtained from the various analytical methods, the reaction conditions such as the reaction temperature was collected for the pyrolysis process and the pyrolysis using the resources containing the heavy oil was conducted using the fixed-bed reactor under the various reaction conditions. Consequently, We found that the content of heavy oil contained in the resources was about 35% and the conversion of heavy oil and the recovery efficiency of thermal degradation oil were about 21 and 80%, respectively.

Flow behavior characteristics according to superficial gas velocity of NiO/MoO3/MoS2 (NiO/MoO3/MoS2의 공탑속도에 따른 유동화 특성)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Lee, Kwan-Young;Kim, Kwang-Deuk;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.13 no.2
    • /
    • pp.79-85
    • /
    • 2017
  • This study identified the loss of minimum fluidization velocity and pressure in accordance with the superficial velocity of $NiO/MoO_3/MoS_2$, a rare metallic oxide and high value-added material in the lab-scale fluidized bed reactor (L=0.25 m, D=0.05 m). The average pressure loss in L/D 1, 2, and 3 of $NiO/MoO_3/MoS_2$ within the scope of superficial gas velocity between 0.07 and 0.45 m/s based on the L/D 1, 2, and 3 of the specimen was shown to be 290~1952 Pa at decreasing flux and 253~1925 Pa at increasing flux. The comparison between the theoretical value proposed by Wen and the test data showed a difference between 0.021~0.36 magnification. Based on these results, this study was able to determine the operation conditions where rare metallic oxides could be applied in real phenomena.

A Study on Removal of T-N by Loess Ball Using Synthetic Wastewater (Loess ball에 의한 총질소 제거에 관한 연구)

  • Shin Sung-Euy;Lee Choon-Boem;Cha Wol-Suk
    • Journal of Life Science
    • /
    • v.15 no.4 s.71
    • /
    • pp.590-594
    • /
    • 2005
  • In this study, the wastewater treatment was conducted to evaluate the removal efficiency of total nitrogen from synthetic wastewater in the F-STEP PROCESS $(anaerobic{\rightarrow}\;oxic\;{\rightarrow}\;anoxic)$ with loess ball as support metrics. The average removal efficiencies of total nitrogen and ammonia nitrogen were $83.0\%\;and\;84.4\%$, respectively. The average nitrification efficiency at the oxic area was $60.9\%$ in the pH range of effluent water between 4.8 and 6.0. On the other hand, in the case of pH range of effluent water between 6.5 and 7.5, the denitrification efficiency at the anoxic area was $96.3\%$. The average concentration of COD was 12.8 ppm and the removal efficiency of COD in the F-STEP PROCESS were $96.3\%$. In the case of SS, the average concentration was $7.0\%$ at the effluent.

A-team Based Approach for Reactive Power/Voltage Control Considering Steady State Security Assessment (정태 안전성 평가를 고려한 무효전력 전압제어를 위한 A-team기반 접근법)

  • Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.2
    • /
    • pp.150-159
    • /
    • 1996
  • In this paper, an A-team(Asynchronous Team ) based approach for Reactive power and volage control considering static security assessment in a power system with infrastructural deficiencies is proposed. Reactive power and voltage control problem is the one of optimally establishing voltage level given several constraints such as reactive generation, voltage magnitude, line flow, and other switchable reactive power sources. It can be formulated as a mixed-integer linear programming(MILP) problem without deteriorating of solution accuracy to a certain extent. The security assessment is to estimate the relative robustness of the system in Its present state through the evaluation of data provided by security monitoring. Deterministic approach based on AC load flow calculations is adopted to assess the system security, especially voltage security. A security metric, as a standard of measurement for power system security, producting a set of discrete values rather than binary values, is employed. In order to analyze the above two problems, reactive power/voltage control problem and static security assessment problem, in an integrated fashion for real-time operations, a new organizational structure, called an A-team, is adopted. An A-team is an organization for agents which ale all autonomeus, work in parallel and communicate asynchronously, which is well-suited to the development of computer-based, multi-agent systems for operations. This A-team based approach, although it is still in the beginning stage, also has potential for handling other difficult power system problems.

  • PDF

The Effect of Sea Water Containing Heavy Oil on RO Membrane (유탁해수의 RO막에 대한 영향)

  • Cho, Bong-Yeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • An experimental study regarding the effect of emulsions on RO is presented. Heavy oil was added to the sea water and the distilled water separately and treated for 30 minutes by a homogenizer to make emulsions. For the case of the sea water without heavy oil the permeate decreased from the beginning of the experiment. Chloride and conductivity increased with time, due to the fouling occurring as the suspended solids in the sea water accumulated on the membrane surface. Rejection rate of salt was 99.6~99.7%. As for the sea water containing heavy oil, the permeate decreased slowly from the beginning of the experiment. This result was the same for the case of the sea water only. However. chloride and conductivity increased significantly when heavy oil was added. In the second experiment with sea water containing heavy oil, the operation time of RO was reduced considerably. With addition of oil, the chloride increased greatly, while the permeate reduced comparatively. In the experiment where emulsion of $0.3{\sim}0.8mg/{\ell}$ was supplied to RO. oil concentration was about 10ppb in the permeate at the end of the experiment. In case of the distilled water containing heavy oil. the conductivity increased. However. the permeate reduced to 30% compared to the case of the sea water containing heavy oil. The case of sea water containing heavy oil showed an opposite result, but the effect of the addition of oil on RO was significant. Oil caused fouling of the RO and the contamination of the whole system, and as the result the system could not be operated properly. As a result the membrane capacity, the amount and water quality of permeate deteriorated significantly.

  • PDF

Treatment of Dredging Suspended Solids Using Chitosan Coagulant (Chitosan 응집제를 이용한 준설토 부유물질 처리)

  • Lee, Jun-Ho;Yang, Seung-Ho;Shin, Yiung-Kyewn;Bang, Ki-Woong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.11
    • /
    • pp.834-846
    • /
    • 2011
  • The objective of this study is to development of IDFIS system, that are consisted of hydrocyclone, rapid flocculation and inclined settler with chitosan coagulant. As the results of Jar test, a chitosan optimum dosage of 40 mg/L for river sediment, and 5 mg/L for tunnelling wastewater sediment, which these conditions leaves of residual turbidity of less than 5 NTU. Because of the effectiveness of chitosan in removing turbidity was independent on pH, the operation of IDFIS system would be simple. The synthesized turbidity was made with clay particles, river sediment, river suspended sediment, and tunnelling wastewater sediment. Results indicate that the mean overall removal efficiency of turbidity, SS, COD and TP were 98%, 99%, 85% and 95%, respectively. Chitosan is very efficient in removing turbidity in the entire turbidity range examined. IDFIS system would have possibility with compact design, because of the increase of floc size favours the floc settling speed and reduces the settling time.

An investigation on the insulation characteristics of $SF_6$ mixtures gas under uniform and non-uniform electric field (평등/불평등 전계에서의 $SF_6$혼합된 가스의 절연파괴특성 연구)

  • Lee, Sang-Hwa;Lee, Young-Jo;Ahn, Hee-Sung;Jeong, Seung-Young;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1397-1398
    • /
    • 2007
  • 본 연구는 $SF_6$와 Dry-air(건조공기), $N_2$, $CO_2$ 가스가 혼합된 절연매체의 절연 특성과 부분방전 특성 연구를 기초실험용 쳄버와 70kV급 GIS mock up을 이용하여 교류전압을 인가하여 실험이 수행되었다. 전자의 경우, Sphere gap 및 Needle/Plate 전극시스템을 이용하여 순수 $SF_6$가스와 Dry-air, $N_2$, $CO_2$ 가스들의 절연내력을 비교하고, 챔버의 압력을 5기압으로 유지한 상태에서 Dry-air, $N_2$, $CO_2$$SF_6$가스의 혼합비를 변화시키면서 절연내력이 측정되었다. 후자의 경우, 기초실험에서 도출된 $SF_6$가스와 Dry-air, $N_2$, $CO_2$의 최적의 혼합비율을 선택한 후, 방전 개시전압과 부분방전 양상을 순수 $SF_6$가스의 결과와 비교분석하기 위한 실험을 수행하였다. 이를 위하여 GIS 사고의 주요원인이 되는 결함들, 즉 Protrusion, Floating, Free moving particle 들을 인위적으로 모의하여 Mock up 내부에 설치하고 내부 압력을 5기압으로 유지한 상태에서 수행되었다. 전자의 경우, $0.5{\sim}5$ 기압 범위 내에서 Dry-air, $N_2$, $CO_2$ 압력을 변화시켰을 때 절연내력은 전극시스템에 무관하게 순수 $SF_6$가스의 결과치의 Dir-air $47{\sim}51%$, $N_2\;48{\sim}61%$, $CO_2\;47{\sim}60%$ 정도이다. 또한 챔버 압력이 5기압인 상태에서 Dry-air, $N_2$, $CO_2$가 80% 혼합된 절연매체는 순수 $SF_6$가스 절연내력의 80%이상의 절연내력을 가지고 있다. 후자의 경우, 인가전압을 고정 시켰을 때, 부분방전 패턴과 방전크기는, 순수 $SF_6$가스와 Dry-air 가 80% 혼합된 절연매체는 동일한 패턴과 방전크기를 나타내고 있다. 이러한 결과를 근거로, 가스 압력이 5기압에서 운전되는 전력기기의 절연매체로서 혼합가스를 사용할 경우, $SF_6$가스와 Dry-air, $CO_2$, $N_2$ 가스들의 혼합비는 2:8정도가 적절한 것으로 제안한다.

  • PDF

Life Prediction of Low Cycle Fatigue for Ni-base Superalloy GTD111 DS at Elevated Temperature (Ni기 초내열합금 GTD111 DS의 고온 저주기 피로수명 예측)

  • Kim, Jin Yeol;Yoon, Dong Hyun;Kim, Jae Hoon;Bae, Si Yeon;Chang, Sung Yong;Chang, Sung Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.765-770
    • /
    • 2017
  • GTD111 DS of nickel base superalloy has been used for gas turbine blades. In this study, low cycle fatigue test was conducted on the GTD111 DS alloy by setting conditions similar to the real operating environment. The low cycle fatigue tests were conducted at room temperature, $760^{\circ}C$, $870^{\circ}C$, and various strain amplitudes. Test results showed that fatigue life decreased with increasing total strain amplitude. Cyclic hardening response was observed at room temperature and $760^{\circ}C$; however, tests conducted at $870^{\circ}C$ showed cyclic softening response. Stress relaxation was observed at $870^{\circ}C$ because creep effects occurred from holding time. A relationship between fatigue life and total strain range was obtained from the Coffin-Manson method. The fratography using a SEM was carried out at the crack initiation and propagation regions.