• Title/Summary/Keyword: 운영 모드

Search Result 185, Processing Time 0.032 seconds

Sensor Node Control Algorithm Based on TinyOS (TinyOS 기반의 센서 노드 제어 알고리즘)

  • Boo, Jun-Pil;Yang, Hyeon-Gyu;Kim, Do-Hyeon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.4
    • /
    • pp.1-8
    • /
    • 2008
  • Recently, there is developing various ubiquitous application services using sensor networks based on TinyOS represented the operating system of sensor node. These sensor networks perform the collection and the transmission of sensing data from sensor node to get the context information. In this paper, we proposes the sensor node control algorithm which converts a sensor node to sleep, active, power off mode according to monitoring result of the voltage state of sensor node. Also, we designs and implement the sensor control module on server, sink, sensor node of sensor networks using this algorithm. It designs a sensor voltage control module of sensor node, data receive and display module of USN server using a java language and TinyOS. And, it checks the voltage state of sensor node, and it changes one of the sleep or power off modes in case of high voltage loss. Accordingly, we effectively use the power of sensor nodes as changing control modes of sensor nodes.

  • PDF

Provable Security of PRF-based Key Derivation Functions according to Input Types of Counters (PRF-기반 키유도함수에서 카운터 입력 형태에 따른 증명가능 안전성)

  • Kim, Nayoung;Kang, Ju-Sung;Yeom, Yongjin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.25 no.3
    • /
    • pp.547-557
    • /
    • 2015
  • The security of all cryptographic algorithms and protocols is based on the confidentiality of secret keys. Key management mechanism is an indispensable part of the cryptographic system and this deals with the generation, exchange, storage, use, and replacement of keys. Within the key management mechanism there are key derivation functions (KDFs) which derive one or more keys from a master key. NIST specifies three families of PRF-based KDFs in SP 800-108. In this paper, we examine the difference of security models between the KDFs and the encryption modes of operations. Moreover we focus on the provable security of PRF-based KDFs according to input types of counters, and show that the counter and feedback modes of KDFs using XOR of counters are insecure, while these modes using concatenation of counters are secure.

A Study on the Improvement of Optimal Load Range for Sliding Pressure Operation of coal-fired Power Plant (석탄화력 발전소 최적 변압운전 부하 범위 개선에 대한 연구)

  • Lee, Sang-Hun;Wang, Min-Seok;Wee, Sang-Bong;Son, Yung-Deug
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.675-680
    • /
    • 2019
  • The coal-fired power plant is operated by a combined operation method, which is operated by sliding pressure operation under low load and by fixed pressure operation under high load for improved efficiency. The combined operation is divided into two and three valve open modes. Each plant is operated by selecting the turbine control valve mode in accordance with the manufacturer's recommendation, but is not really operating at the optimal sliding pressure operation according to load range, also Load range of each plant is configured differently. The internal efficiency of the high-pressure turbines is reduced due to loss of the turbine valves and the plant efficiency is reduced. To solve these problems, In this paper, the optimum load range is selected through the analysis method of thermal performance by each load in order to improve the optimum variable pressure operation load range by turbine control valve mode.

A Study for Reliability Improvement of Belt Type Door System using FMECA (FMECA 적용을 통한 벨트식 도어시스템 신뢰성 향상에 관한 연구)

  • An, Cheon-Heon;Lee, Do-Sun;Son, Young-Jin;Lee, Hi-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.1
    • /
    • pp.58-64
    • /
    • 2010
  • As a modem urban train is getting complex in terms of high-technology in its systems and components, the failure management should be performed with scientific and systematic technique. FMEA is a technique to analyze the failure trends of component parts and influences to the higher level system in order to discover the design incompleteness and potential defects, which is for improving reliability. Especially, FMECA (Failure Mode Effects, and Criticality Analysis) is used in case that the criticality that has an immense influence to the system is important. In case of urban train, in its design and manufacturing steps, FMEA is frequently used as an analysis technique to meet the safety objectives and eliminate potential hazards/failures since the concepts of reliability of train is introduced these days. Though, FMEA technique in the maintenances steps lacks in its investigation and applications yet. FMEA is also not applied to the trains operated by Seoul metro in the design and manufacture steps excepts the newest trains. In this paper, through analyzing the failures/maintenance data of the belt-type door systems used in trains operated in Seoul metro Line 1, which is accumulated in RIMS (Rolling-stock Information Maintenance System), FMEA procedures to the belt-type door engines are proposed. Especially, an effort is made, to approach the detailed FMECA procedures to the door magnet valve and switch and door engine devices which vastly influences the customer safety and satisfaction.

A operation scheme to the power consumption of base station in wireless networks (무선망에서 기지국의 전력소모에 대한 운영 방안)

  • Park, Sangjoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.2
    • /
    • pp.285-289
    • /
    • 2020
  • The configuration of hierarchical wireless networks is provided to support diverse network environments. In the base station, two system state can be basically considered for the operation management so that the state transition may be occurred between active and sleep modes. Hence, to reduce energy consumption the system operation management of the low power should be considered to the base station system. In this paper we consider the analytical model of Discontinuous Reception (DRX) to investigate the system management. We provide the analysis scheme of base station system by the DRX model, and the low power factor would be investigated for the energy consumption. We also use the finite-state Markov system model that in a system state period the wireless resource request and the operation of service call arrival interval is considered to numerically analyze the performance of energy saving operations of base station.

Effects of the Open Level of the Side Window on the Control of the Temperature and Relative Humidity in the Fog Cooling Greenhouse (포그냉방 온실에서 측창개폐수준이 온습도 제어에 미치는 영향)

  • Kim, Young-Bok;Sung, Hyun-Soo;Yun, Nam-Kyu;Lee, Si-Young;Hwang, Seung-Jae;Kim, Hyeon-Tae;Lee, Jang-Pyung
    • Journal of agriculture & life science
    • /
    • v.45 no.6
    • /
    • pp.265-278
    • /
    • 2011
  • Effects of the open level of the side window were studied to control the temperature and relative humidity in the fog cooling greenhouse. The greenhouse was cooled by air atomizing spray nozzles of the air and water two-fluid process. The control process includes the measuring of environmental variables, setting and coding of the water balance equations and heat balance in greenhouse, calculating of the roof window open and spray water, and operating of the motor and pump. The target temperature and relative humidity were set at $28^{\circ}C$, 75%, respectively. The three modes of the side window open level were 0%, 50% and 100%. The average dry bulb temperatures of the inside air were 28.2, 27.2 and $26.3^{\circ}C$, respectively and their standard deviation was ranged from $0.4^{\circ}C$to $0.8^{\circ}C$. Also the relative humidity of the 0% mode was the best controlled one with the average of 76.3% and the standard deviation of 2.1%.

A Study on Robust Optimal Sensor Placement for Real-time Monitoring of Containment Buildings in Nuclear Power Plants (원전 격납 건물의 실시간 모니터링을 위한 강건한 최적 센서배치 연구)

  • Chanwoo Lee;Youjin Kim;Hyung-jo Jung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.3
    • /
    • pp.155-163
    • /
    • 2023
  • Real-time monitoring technology is critical for ensuring the safety and reliability of nuclear power plant structures. However, the current seismic monitoring system has limited system identification capabilities such as modal parameter estimation. To obtain global behavior data and dynamic characteristics, multiple sensors must be optimally placed. Although several studies on optimal sensor placement have been conducted, they have primarily focused on civil and mechanical structures. Nuclear power plant structures require robust signals, even at low signal-to-noise ratios, and the robustness of each mode must be assessed separately. This is because the mode contributions of nuclear power plant containment buildings are concentrated in low-order modes. Therefore, this study proposes an optimal sensor placement methodology that can evaluate robustness against noise and the effects of each mode. Indicators, such as auto modal assurance criterion (MAC), cross MAC, and mode shape distribution by node were analyzed, and the suitability of the methodology was verified through numerical analysis.

Development of an Operation Control System of the Vertical Transferable Korean Personal Rapid Transit (수직이송 서비스가 가능한 한국형 PRT 운행제어시스템 개발)

  • Kim, Baek-Hyun;Um, Ju-Hwan;Jeong, Rag-Gyo;Byun, Yeun-Sub;Kang, Seok-Won
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.337-343
    • /
    • 2014
  • The PRT(Personal Rapid Transit) in material or immaterial guided tracks is operated automatically according to the needs of passengers with the optimal non-stop path from the source to the destination. In recent years, the personal rapid transit (PRT) system, which affords superior accessibility and ease of use, has been spotlighted as a new transport system for the future. In this study, a method for vertical lifting of PRT vehicles was proposed to facilitate interlink with other means of transport and thereby improve the efficiency of door-to-door transport. For this purpose, operation control interfaces were designed and experiments were conducted. Programmable Logic Controller (PLC) dedicated for the PRT vertical lift was designed to interface with Operation Control Center (OCC) by Modbus TCP over Ethernet. We implemented a 3D graphical PRT operation simulator which can emulate the mixing operation of the virtual vehicles and the actual vehicles.

IPSec based Network Design for the Mobile and Secure Military Communications (이동성과 보안성 만족 군용 통신을 위한 IPSec 기반 네트워크 설계)

  • Jung, Youn-Chan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.9B
    • /
    • pp.1342-1349
    • /
    • 2010
  • Full-mesh IPSec tunnels, which constitute a black network, are required so that the dynamically changing PT (Plain Text) networks can be reachable across the black network in military environments. In the secure and mobile black networks, dynamically re-configuring IPSec tunnels and security policy database (SPD) is very difficult to manage. In this paper, for the purpose of solving mobility and security issues in military networks, we suggest the relating main technologies in association with DMIDP (Dynamic Multicast-based IPSec Discovery Protocol) based on existing IPSec ESP (Encapsulating Security Payload) tunnels and IPSec key managements. We investigate the main parameters of the proposed DMIDP techniques and their operational schemes which have effects on mobility and analyze operational effectivemess of the DMIDP with proposed parameters.

Operation and Control Strategy of a New Hybrid ESS-UPS system (수요관리와 비상발전기능을 갖는 새로운 하이브리드 ESS-UPS 시스템의 운영 및 제어전략)

  • Kim, Sang-jin;Kwon, Min-ho;Kim, Hyo-jun;Choi, Se-wan;Hwang, Dong-ok;Lee, Dong-ju;Paik, Seok-min
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.339-340
    • /
    • 2017
  • 본 논문은 에너지 저장시스템(ESS)과 무정전 전원장치(UPS)를 하나로 통합한 새로운 하이브리드 ESS-UPS 시스템을 제안한다. 제안하는 시스템은 ESS와 UPS를 하나로 통합함으로써 전력변환 시스템(PCS)의 가격을 줄이고 배터리의 이용률을 높일 수 있다. 또한 기존의 on-line UPS와는 달리 두 종류의 중요부하를 구성할 수 있어 PCS의 용량대비 비상발전 용량을 증대시키는 것이 가능하다. 본 논문에서는 제안하는 하이브리드 ESS-UPS 시스템의 운영 전략 및 급속 모드전환 알고리즘을 제안하며, 5kW급 축소 시작품을 통한 실험 결과로 타당성을 입증하였다.

  • PDF