• Title/Summary/Keyword: 우수유출

Search Result 650, Processing Time 0.027 seconds

Surgical Outcome of Tetralogy of Fallot in Adolt -Implication of Preoperative Cyanosis- (수술 전 청색증 정도에 따른 성인 활로씨 4징증의 임상 양상)

  • Kim Sang-hwa;Park Soon-Ik;Park Jung-Jun;Song Hyun;Lee Jae-Won;Seo Dong-Man;Song Meong-Gun;Song Jong-Min;Kang Duck-Hyun;Song Jae-Kwan;Jang Wan-Sook;Kim Young-Hwue;Yun Tae-Jin
    • Journal of Chest Surgery
    • /
    • v.38 no.4 s.249
    • /
    • pp.271-276
    • /
    • 2005
  • We analysed differences in operative methods and postoperative outcome according to the severity of preoperative cyanosis in adult ToF (Tetralogy of Fallot) patients. Material and Method: From August 1989 to June 2001, thirty three adult patients, 18 females and 15 males, underwent total correction for ToF. Their age ranged from 15 years to 54 years (median: 34). Patients were divided into 2 groups by preoperative $SaO_2$ (arterial oxygen saturation): group I$(n=cyanotic,\;SaO_2\;\geq94\%)$ and group II $(acyanotic,\; SaO_2\geq95%)$. Preoperative median hemoglobin level was higher in group I compared to group II (17.5 g/dl vs 15 g/dl). Postoperative follow-up duration ranged from 1 to 94 months (670 patient-month, median: 14 months), and 63 two-dimensional echocardiographic examinations were done during this period. Result: There were no early or late mortality. With regard to RVOT (right ventricular outflow tract) reconstruction, trans-annular patch and RV-PA extracardiac conduit were used in 7 and 3 patients respectively, and all of them belonged to group I. In group I, cardiopulmonary bypass time, aortic cross-clamping time, ICU day, hospital day were significantly longer than in group II, and postoperative inotropic support was significantly greater than in group II. There was no ventricular arrhythmia in both groups, and one patient in group I suffered from atrial arrhythmia, which was resolved spontaneously after tricuspid and pulmonary valve replacement. During follow-up periods, functional class, residual RVOT stenosis and pulmonary regurgitation, tricuspid regurgitation, occurrence of ventricular and atrial arrhythmias were comparable between two groups. Conclusion: In adult ToF patients with severe preoperative cyanosis, more aggressive RVOT reconstruction and careful postoperative care are mandatory. However intermediate-term outcome of this group of patients is comparable to the patients with minimal or no preoperative cyanosis.

Development of Domestic Rainwater Treatment System and its Application in the Field (소규모 빗물처리시설 개발 및 현장 적용성 평가 연구)

  • Pak, Gijung;Park, Minseung;Kim, Hwansuk;Lim, Yoonsoo;Kim, Sungpyo
    • Journal of Wetlands Research
    • /
    • v.18 no.1
    • /
    • pp.24-31
    • /
    • 2016
  • The increase of impervious area in cities caused the unbalanced water cycle system and the accumulated various contaminants, which make troubles as introducing into watershed. In Korea, most of rainfall in a year precipitate in a summer season. This indicate that non-point source pollution control should be more important in summer and careful rainfall reuse strategy is necessary. Accordingly, the aim of this study is to monitor the characteristics of rainfall contaminants harvested in roofs and to develop the rainfall treatment system which are designed to fit well in a typical domestic household including rain garden. The rain garden consists of peatmoss, gravel and san to specially treat the initial rainfall contaminants. For this purpose, lab scale experiments with synthetic rainfall had been conducted to optimize the removal efficiency of TN, TP and CODcr. After lab scale experiments, field scale rainfall treatment system installed as a pilot scale in a field. This system has been monitored during June to July in 2015 in four time rainfall events as investigating the function of time, rainfall, and pollutant concentrations. As results, high loading of pollutants were introduced to the rainfall treatment system and its removal efficiency is increased as increase of pollutant concentrations. Since it is common that the mega-size of rainfall treatment system is not attractive in urban area, small scale rainfall treatment system is promising to treat the non-point source contaminants from cities. In addition, this small scale rainfall treatment system could have a potential to water resue system in islands, which usually suffer the shortage of water.

Operating Status and Improvement Plans of Ten Wetlands Constructed in Dam Reservoirs in Korea (국내 10개 댐저수지 인공습지의 운영현황 및 개선방안)

  • Choi, Kwangsoon;Kim, Sea Won;Kim, Dong Sup;Lee, Yosang
    • Journal of Wetlands Research
    • /
    • v.16 no.3
    • /
    • pp.431-440
    • /
    • 2014
  • To propose the improvement and management plans to strengthen the pollutant removal efficiency of dam reservoir's constructed wetlands(CWs), the operation status and configuration of CWs (including water depth, operational flow, water flow distribution, residence time, and pollutant removal efficiency, aspect ratio, open water/vegetation ratio etc.) were analyzed in 10 major wetlands constructed in dam reservoirs. The pollutant concentrations in the inflows of the studied CWs were lower than those of American and European constructed wetlands. Especially, organic matter concentrations in all of inflows were below 3 mg/L(as BOD) due to advanced treatment of sewage disposal plant and an intake of low concentration water during dry and normal seasons. The average removal efficiency of total nitrogen(TN) and total phosphorus(TP) for 10 CWs ranged from 7.6~67.6%(mean 24.9%) and -4.9~74.5%(mean 23.7%), respectively, showing high in wetlands treating municipal wastewater. On the other hand, the removal efficiency of BOD was generally low or negative with ranging from -133.3 to 41.7%. From the analysis of the operation status and configuration of CWs, it is suggested that the low removal efficiency of dam reservoir's CWs were caused by both structural (inappropriate aspect ratio, excessive open water area) and operational (neglecting water-level management, lack of facilities and operation for first flush treatment, lake of monitoring during rainy events) problems. Therefore, to enable to play a role as a reduction facility of non-point source(NPS) pollutants, an appropriate design and operation manuals for dam reservoir's CW is urgently needed. In addition, the monitoring during rainy events, when NPS runoff occur, must be included in operation manual of CW, and then the data obtained from the monitoring is considered in estimation of the pollutant removal efficiency by dam reservoir's CW.

Effects of High Temperature Sterilization on Qualities Characteristics of the Canned Boiled Oyster (가열살균처리가 굴 보일드통조림의 품질특성에 미치는 영향)

  • Kong, Chung-Sik;Yun, Jae-Ung;Oh, Dong-Hun;Park, Jun-Yong;Kang, Jin-Yeong;Oh, Kwang-Soo
    • Journal of agriculture & life science
    • /
    • v.43 no.6
    • /
    • pp.85-93
    • /
    • 2009
  • The boiled oyster vacuum-packed in cylindrical can(No. 301-3) were thermally processed at $115^{\circ}C$ to reach Fo values of 5~20 min. The yield was slightly decreased with the increasing of Fo-values (79.2~ 83.7%), and volatile basic nitrogen (VBN) contents increased markedly with the increasing of Fo-value. In fatty acid composition of canned oyster, the composition ratio of saturates and monoenes such as 14:0, 16:0 and 18:1n9 increased, while polyunsaturated fatty acids such as 20:5n-3 and 22:6n-3 decreased with the increasing of Fo-value. In taste compounds, content of total free amino acid in raw oyster was 1,533.5 mg%, and this total content was slightly increased (1,140.8~1,266.2 mg%) with the increasing of Fo values. But contents of betaine and ionic minerals such as Na, K, Mg and P decreased markedly by thermal processing at $115^{\circ}C$. As compared with Fo 5 min. heat treatment; Fo 20 min. heat treatment at $115^{\circ}C$ became more hardened in texture of oyster meat. In sensory evaluations on organoleptic characteristics, no significant difference at 5% level was observed among the canned boiled oyster meats heated at Fo 5~15 min.

Effect of a Frontal Impermeable Layer on the Excess Slurry Pressure during the Shield Tunnelling (전방 차수층이 쉴드터널 초과 이수압에 미치는 영향)

  • Lee, Yong-Jun;Lee, Sang-Duk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1199-1213
    • /
    • 2011
  • Slurry type shield would be very effective for the tunnelling in a sandy ground, but low slurry pressure could cause a tunnel face failure or a ground settlement in front of the tunnel face. Thus, the stability of tunnel face could be maintained by applying an excess slurry pressure that is larger than the active earth pressure. However, the slurry pressure should increase properly because an excessively high slurry pressure could cause the slurry flow out or the passive failure of the frontal ground. It is possible to apply the high slurry pressure without passive failure if a horizontal impermeable layer is located in the ground in front of the tunnel face, but its location, size, and effects are not clearly known yet. In this research, two-dimensional model tests were carried out in order to find out the effect of a horizontal impermeable layer for the slurry shield tunnelling in a saturated sandy ground. As results, larger slurry pressure could be applied to increase the stability of the tunnel face when the impermeable layer was located in the ground above the crown in front of the tunnel face. The most effective length of the impermeable grouting layer was 1.0~1.5D, and the location was 1.0D above the crown level. The safety factor could be suggested as the ratio of the maximum slurry pressure to the active earth pressure at the tunnel face. It could also be suggested that the slurry pressure in the magnitude of 3.5~4.0 times larger than the active earth pressure at the initial tunnel face could be applied if the impermeable layer was constructed at the optimal location.

  • PDF

The Effect of Pervious Pavement on Reducing the Surface Runoff (투수성 포장재의 우수 표면유출 저감 효과)

  • Lee, Chun-Seok;Ryu, Nam-Hyung;Han, Seung-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.6
    • /
    • pp.26-37
    • /
    • 2008
  • The purpose of the study was to evaluate the effect of pervious pavements on reducing the surface runoff caused by rainfall. The surface runoff from twelve steel experimental beds with different pavement had been recorded every minute from May to September 2008, by the measuring system of tipping buckets(0.1mm/count) and data aquisition systems(National Instrument's Labview and DAQ boards & Autonics PR12-4). The dimension of the experimental bed was $1.5m(W){\times}2.0m(L){\times}0.6m(D)$ and eleven different kinds of vegetational(grass, grass+cubic stone, grass+hole brick), modular(brick, cubic stone, small cubic stone, wood block, interlocking block, clay brick, granular clay brick) and granular(naked soil, gravel) paving materials and concrete were applied for the comparison. Six rain events with depth over 30mm were selected and compared. The maximum depth of the rainfall selected was 137.5mm for 28 hours, and the minimum 30mm for 5 hours. The maximum rainfall per hour was 23mm/hr and the minimum 11.4mm/hr. The major findings were as follows; 1. All pervious pavement applied reduced over 75% of the surface runoff compared with concrete pavement. The grassy and porous pavements were relatively efficient in reducing surface runoff. 2. The grass was the more efficient as intercepting average 69.5mm of initial surface runoff, and maximum 77.8mm at the condition of 13.5mm/hr rainfall. The next was gravel intercepting maximum 65.5mm at the condition of 13.5mm/hr and the 40.9mm at 19.1mm/hr, average 55.7mm. 3. The modular pavements common in urban area were not good in intercepting the runoff except the 'clay granular brick' compared with others. The 'clay granular brick' showed relatively efficient intercepting average 14.1mm, which was the bigger amount than the 'grass+hole brick'. 4. The 'naked soil' were more effective than the 'concrete', 'brick', and 'interlocking block' in reducing the surface runoff, but less efficient than other materials. The capacity of the 'naked soil' to intercept the initial rainfall was similar to the 'brick'. As summary, the more grassy and porous pavement shows more effective in reducing surface runoffs.

Analysis of Rainfall Runoff Delay Effect of Vegetation Unit-type LID System through Rainfall Simulator-based Probable Rainfall Recreation (인공강우기 기반 확률강우재현을 통한 식생유니트형 LID시스템의 우수유출지연 효과분석)

  • Kim, Tae-Han;Park, Jeong-Hyun;Choi, Boo-Hun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.22 no.6
    • /
    • pp.115-124
    • /
    • 2019
  • In a climate change environment where heat damage and drought occur during a rainy season such as in 2018, a vegetation-based LID system that enables disaster prevention as well as environment improvement is suggested in lieu of an installation-type LID system that is limited to the prevention of floods. However, the quantification of its performance as against construction cost is limited. This study aims to present an experiment environment and evaluation method on quantitative performance, which is required in order to disseminate the vegetation-based LID system. To this end, a 3rd quartile huff time distribution mass curve was generated for 20-year frequency, 60-minute probable rainfall of 68mm/hr in Cheonan, and effluent was analyzed by recreating artificial rainfall. In order to assess the reliability of the rainfall event simulator, 10 repeat tests were conducted at one-minute intervals for 20 minutes with minimum rainfall intensity of 22.29mm/hr and the maximum rainfall intensity of 140.69mm/hr from the calculated probable rainfall. Effective rainfall as against influent flow was 21.83mm/hr (sd=0.17~1.36, n=20) on average at the minimum rainfall intensity and 142.27mm/hr (sd=1.02~3.25, n=20) on average at the maximum rainfall intensity. In artificial rainfall recreation experiments repeated for three times, the most frequent quartile was found to be the third quartile, which is around 40 minutes after beginning the experiment. The peak flow was observed 70 minutes after beginning the experiment in the experiment zone and after 50 minutes in the control zone. While the control zone recorded the maximum runoff intensity of 2.26mm/min(sd=0.25) 50 minutes after beginning the experiment, the experiment zone recorded the maximum runoff intensity of 0.77mm/min (sd=0.15) 70 minutes after beginning the experiment, which is 20 minutes later than the control zone. Also, the maximum runoff intensity of the experiment zone was 79.6% lower than that of the control zone, which confirmed that vegetation unit-type LID system had rainfall runoff reduction and delay effects. Based on the above findings, the reliability of a lab-level rainfall simulator for monitoring the vegetation-based LID system was reviewed, and maximum runoff intensity reduction and runoff time delay were confirmed. As a result, the study presented a performance evaluation method that can be applied to the pre-design of the vegetation-based LID system for rainfall events on a location before construction.

Finite Element Analysis on the Deformation Behavior Safety of a Gas Valve (가스밸브의 변형거동 안전성에 관한 유한요소해석)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.4
    • /
    • pp.70-75
    • /
    • 2017
  • This paper presents the FEM analysis results on the deformation behavior safety of automatic cut-off horizontal and conventional vertical gas valves. Based on the FEM analysis, the primary maximum deformation of $4.4{\mu}m$ was formed on the right end side of a valve body when the internal gas pressure was supplied on the screw port and gas discharge port of an automatic cut-off horizontal gas valve. And the secondary maximum deformation of $2.9{\mu}m$ was formed on the end side of safety valve port. This small deformation of an automatic cut-off horizontal gas valve is strongly related to the balanced design of a horizontal gas valve main body, which is composed of a screw part, gas outlet port, port for a stem and spindle shaft assembly, and safety valve port. But, the primary maximum deformation of 0.076mm was formed on the upper part of a conventional automatic cut-off vertical gas valve when the internal gas pressure was supplied on the screw port and gas discharge port. And the secondary maximum deformation of 0.055mm was formed on the left end side of a gas outlet port. This may effect on the sealing clearance of o-ring that is inserted on the groove of an automatic cut-off unit. Thus, this paper recommends an automatic cut-off horizontal gas valve compared with that of a conventional gas valve for a gas leakage free mechanism of a LPG cylinder valve.

Study on Efficiency of Silicon in PC Dripper of Drip Irrigation (점적관수기의 PC 드립용 실리콘 특성에 관한 연구)

  • Kim, J.H.;Choi, J.M.;Song, N.S.;Kim, D.E.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.56-56
    • /
    • 2017
  • 점적 호스 중 PC 드립은 경질 호스의 내부에 Micro-path가 부착된 유로장치와 압력을 보상하는 연질의 실리콘으로 구성되어 있다. 이때 일정압력에서 적정 길이까지 동시에 내부 압력을 유지하며 균등하게 유출구를 통하여 유량을 공급하는 압력보상 기능이 매우 중요하다. 그러나 이 부분에 대한 기술은 선진국에 비해 아직 부족하여 수입에 의존하는 경향이 매우 높다. 뿐만 아니라 선진국 제품에 비해 유로장치 및 연질 실리콘의 탄성이 균일하지 못해 압력에 따른 유량의 편차가 큰 편이다. 본 연구에서는 우리나라 제품의 PC 드립 압력 균등성 기술을 향상시키기 위해 PC 드립의 핵심기술인 연질 실리콘의 성능에 대한 평가와 유량의 편차를 분석하여 문제점을 통한 개선방안을 제시하고자 하였다. 연질 실리콘의 규격은 $17{\times}8{\times}0.85mm$ (가로${\times}$세로${\times}$두께)로서 Water line의 내부에 결합되어 구성된다. PC 드립용 실리콘은 국내 A사 제품을 중심으로 하여 성능을 측정하였다. 측정을 정밀하게 하기 위해 Microtester를 사용하여 일정하게 하중이 부과되도록 하였다. 연질의 실리콘의 경도는 압력 보상에 중요한 기능을 하고 있으며 또한 PC 드립의 경질 미로와 같이 압력을 제어하는 역할을 하고 있다. 국내 A사의 실리콘 경도는 이상적인 실리콘 경도에 비하면 매우 불균일하였다. 세부적으로는 40 이하의 낮은 경도에서는 비교적 일치하였으나 경도 45 이상에서는 큰 차이를 보여주고 있었다. 국내 A사의 실리콘 경도에 따른 공급유량의 특성에서는 실리콘의 경도가 낮을수록 실리콘은 무르며 탄성이 줄어든다. 반면에 경도가 높을수록 탄성이 커지고 딱딱한 특성을 가진다. 동일한 PC 드립에 실리콘의 경도별 특성은 경도에 따른 유량이 반드시 일정하지 않으며 대체로 경도가 높을수록 동일 압력에 대해 유량이 많아지는 것을 알 수 있었다. 압력의 변화에 대해 유량이 일정하게 유지하는 특성을 가질수록 사용범위가 넓어지고 안정성이 높은 것으로 판단되며 실리콘 경도 35~55 범위에서 1~2bar의 공급압력에서 사용하는 것이 적합할 것으로 보여진다. 경도 45의 실리콘을 사용하여 수입 드립, 국내 A사의 드립 및 수입과 국내 혼용시 압력에 따른 공급유량의 특성을 분석하였다. 최대 유량과 최소 유량에서 발생되는 오차는 수입 실리콘이 비교적 작았으나 3.6 bar 이상에서는 유량이 급격히 떨어지는 양상을 보였다. 국내 A사의 제품은 0.8~2.0 bar 까지 성능이 비슷했으나 0.8 bar 이하에서는 오차가 있었으나 높은 압력에서는 오히려 성능이 우수하였다. 수입 드립과 다소 유사한 성능을 나타낸 것이 A사 드립과 수입 실리콘을 혼용하여 사용한 것은 전체적으로 비슷한 양상을 나타내었다. 따라서 실리콘 경도 오차를 고려하면 압력별 유량의 변화는 실리콘의 경도와 밀접한 관계가 있는 것으로 판단되었다.

  • PDF

Removal of Volatile Organic Silicon Compounds (Siloxanes) from Landfill Gas by Adsorbents (흡착제에 의한 매립가스 중 휘발성 유기규소화합물(실록산) 제거특성)

  • Seo, Dong-Cheon;Song, Soo-Sung;Won, Jong-Choul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.793-802
    • /
    • 2009
  • Adsorption properties were estimated for the organic silicon compounds (siloxanes) in an actual landfill gas (LFG) using adsorbents such as coconut activated carbon, coal activated carbon, silica gel, sulfur adsorbent, carbonized sludge, and molecular sieve 13X. Coconut activated carbon showed the highest removal efficiency of more than 95%. The desorption of hexamethyldisiloxane (L2) from the adsorbent, however, resulted in the remarkable concentration variation of the compound in the treated gas. Silica gel, which had high adsorption capacity for L2 in single substance adsorption experiment in the other study, could not remove the component in the actual landfill gas while it adsorbed well octamethylcyclotetrasiloxane (D4) and decamethylcyclopentasiloxane (D5) in the LFG. Therefore the elimination of hexamethyldisiloxane is an important factor to determine the level of total organosilicon compound in pretreated landfill gas. Moreover, the L2 from the actual landfill gas was effectively adsorbed by the serial adsorption test using two columns packed with coconut activated carbon which has the great capacity of siloxanes removal among others. In order to utilize efficiently LFG as a renewable energy, the emission and adsorptive characteristics of the substance to be treated should be considered for the organization, operation, and management of pretreatment process.