• Title/Summary/Keyword: 용적분석

Search Result 618, Processing Time 0.029 seconds

Analysis of Performance of Organic Rankine Cycle for Inlet Condition of Displacement Type Expander (용적형 팽창기 입구 조건 변화에 따른 유기랭킨사이클 성능 분석)

  • Shin, Dong Gil
    • Journal of Energy Engineering
    • /
    • v.26 no.1
    • /
    • pp.23-27
    • /
    • 2017
  • An expander of an organic Rankine cycle is an essential component that significantly influences its entire performance and cycle efficiency. The inlet pressure and temperature of the expander used for the organic Rankine cycle are limited by the expander's mechanical properties and the characteristics of the working fluid. The organic Rankine cycle's output, heat absorption, and efficiency are altered by the inlet pressure and temperature of the expander. In this study, a theoretical comparative analysis was conducted on an organic Rankine cycle's performance changes, which are dependent on the inlet condition of the expander. The working fluid is an R134a refrigerant, and the expander is a positive-displacement type.

Effects of Functional Electrical Stimulation of Rectus Abdominis on Respiratory Capabilities in Children with Spastic Cerebral Palsy (복직근의 기능적 전기자극이 경직형 뇌성마비 아동의 호흡 능력에 미치는 효과)

  • Cho, Mi-Suk;Park, Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.4
    • /
    • pp.601-612
    • /
    • 2005
  • 본 연구는 복직근의 기능적 전기자극이 경직형 뇌성마비 아동의 1회 호흡용적과 폐활량 등의 호흡능력과 복직근의 근육활동에 미치는 영향을 알아보기 위해서 대구 시내 OO특수학교에 재학 중인 14세 이상 16세 미만의 경직형 사지 뇌성마비 아동 6명(남자 3, 여자 3)을 대상으로 하여 복직근에 1회 20분. 주 3회씩 총 6주간 기능적 전기자극을 적용하였다. 기능적 전기자극의 적용 6주 전과, 직전에 두 번의 사전 검사와 적용 후 사후 검사를 실시하였다. MP30(Biopack, USA)을 이용하여 폐활량과 예측치 폐활량 백분율, 1회 호흡용적을 검사하였으며 Table면전극 근전도(Noraxon, USA)를 이용하여 복직근의 근육 활동량을 측정하였다. 분석결과는 다음과 같다. 1. 복직근의 기능적 전기자극 적용 6주 전과 직전의 폐활량은 유의한 차이가 없었으나, 적용 후의 폐활량은 적용 전에 비해 유의한 증가를 나타내었다(p<0.05). 2. 복직근의 기능적 전기자극 적용 6주 전과 직전의 예측치 폐활량 백분율은 유의한 차이가 없었으나, 적용 후의 예측치 폐활량 백분율은 적용 전에 비해 유의한 증가를 나타내었다(p<0.05). 3. 복직근의 기능적 전기자극 적용 6주 전과 직전의 1회 호흡용적은 유의한 차이가 없었으나, 적용 후의 1회 호흡용적은 적용 전에 비해 유의한 증가를 나타내었다(p<0.05). 4. 복직근의 기능적 전기자극 적용 6주 전과 직전의 복직근의 활동 값은 유의한 차이가 없었으나 적용 후의 복직근의 활동 값은 적용 전에 비해 유의한 증가를 나타내었다(p<0.05). 이상의 결과를 종합해 볼 때 6주간의 복직근의 기능적 전기자극이 경직형 뇌성마비 아동에 있어서 복직근의 근력을 강화시킴으로써 폐활량과 1회 호흡 용적 등의 호흡능력을 향상시킴을 확인할 수 있었다.

  • PDF

Measurement of a Blood Velocity by using Photoplethysmograph and Radial Artery Pulse Wave Equipped with Magnetic Hall Device (자성 홀소자 맥진기와 용적맥파계의 맥진파형을 이용한 혈류속도 측정 연구)

  • Jang, Deok-Hyeong;Kim, Dam-Bee;Choi, Suel-Gi;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.4
    • /
    • pp.130-135
    • /
    • 2012
  • One prototype product of clip-type pulsimeter equipped with magnetic field sensing semiconductor Hall device after one permanent magnet attached "Chwan" position in center of a radial artery was developed. The clip-pulsimeter was composed of the hard ware system measuring to voltage signals. To measure the blood velocity, the radial artery pulsimeter is simultaneously connected the PPG (photoplethysmograph). Analysis and comparison of two pulse waves data has done obtained from a clinical test of forty subjects of 20 ages. The value of a blood velocity simultaneously measured from a radial artery puls wave and PPG is an average value of 0.8m/s. The usage of this research results is possible to store the biomedical signals for health care.

Urban Tissue, Zoning and Achieved Floor Area Ratio (A-FAR) - Focused on Developed Floor Area Ratio (D-FAR) Compared to the Legal Floor Area Ratio (L-FAR) in Residential Area and Commercial Area in Seoul - (용적실현비(A-FAR)에 영향을 미치는 용도지역별 대지특성에 대한 분석 - 서울시 주거지역 및 상업지역에서 법정용적률(L-FAR) 대비 실현된 용적률(D-FAR)을 중심으로 -)

  • Kim, Soo Hyun;Choi, Chang Gyu
    • Journal of Korea Planning Association
    • /
    • v.54 no.2
    • /
    • pp.33-45
    • /
    • 2019
  • The Legal Floor Area Ratio (L-FAR) has been used as a major urban planning tool for efficient management of land use, landscape, and density. The Developed Floor Area Ratio (D-FAR) in each parcel is realized by such physical and institutional factors as urban tissue, local characteristics, and zoning with the L-FAR. The Achieved Floor Area Ratio (A-FAR), the ratio of the D-FAR to the L-FAR, is the relationship between realized density and the intended/desired outcomes of the regulations. The A-FAR informs the efficiency of L-FAR and its effect on parcels, and is an indicator of the demands of real estate developments under the zoning regulation. This study used detailed data of each parcel's characteristics, including parcel size, road width, and the number of roads bordered by a parcel, to identify the influencing factors on A-FAR. This analysis confirmed that the parcel size has a non-linear negative effect in the residential zone but a linear positive effect on A-FAR in the commercial zone. The width of the parcel's frontage in the commercial zone has a positive effect on the value, while in the residential zone the narrower width has higher A-FAR. In Seoul, the residential zone has higher A-FAR than the commercial zone, which means that the former has a relatively higher development pressure but a lower designated L-FAR. This result reflects that Seoul's residential zone absorbs the demand of commercial uses because of the significant permitting of mixed land use and has high-density residential buildings.

Analysis of Performance Characteristics of Swash-Plate-Type Hydraulic Piston Motor (사판식 유압 피스톤모터의 성능특성 분석)

  • Lee, Yong-Bum;Kim, Kwang-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.11
    • /
    • pp.1441-1446
    • /
    • 2012
  • An axial-piston-type hydraulic motor involves friction and leakage losses at the sliding parts, contact loss at the mechanism assembly parts, volumetric loss caused by the pressure drop, housing oil churning loss and compressibility from the hydraulic oil pipe resistance, etc. the friction and volumetric loss at the hydrostatic bearing between the piston shoe and the swash plate rotating at high speed and having an oil film gap of 8-15 ${\mu}m$ strongly affects the total efficiency of the hydraulic motor. In this study, a variable swash-plate-type hydraulic piston motor operating under a maximum pressure of 35 MPa, maximum speed of 2,500 rpm, and displacement of 320 cc/rev is tested to verify the optimal ratio of the hydrostatic bearing which is closely related to the hydraulic motor performance.

Pharmacokinetics of antitumer agents, KR 53170 (항암성분 KR 53170 및 관련화합물의 약물동태 연구)

  • 권광일
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1993.04a
    • /
    • pp.130-130
    • /
    • 1993
  • 실험목적: KR 53170 및 KR 53234 는 천연물에서 분리 추출한 화합물로 terpene lacton ring을 가진 약산성 물질이다. in vitro 항종양 실험에서 종양억제효과가 있었고 in vivo 항종양 실험에서도 유의성 있는 효과가 있었으며 급성 경구독성시험에서도 독성이 낮은 것으로 평가 되었다. 이에 따라 KR 53170 등의 약물동태학적인 성질을 연구하여 독성실험과 임상실험을 위한 용법용량을 결정하고 나아가 본약물의 제제개발에 도움이 되도록 본 연구를 시행하였다. 방법: KR 53170 및 53234은 경구시 20mg/kg, 정맥투여시는 10mg/kg로 투여하였다. Rat의 혈장 sample 채취는 ether로 흡입마취 시킨 후 heart puncture 하였다. 뇨시료는 대사 cage를 이용하여 채취하였으며 얻어진 모든 시료는 HPLC로 분석 하였다. 분석결과는 computer program 'Multi-free'를 이용하여 주요 pqarameter를 산출하였다. 인체혈액에 대한 혈청단백결합율 측정은 ultrafiltration법을 이용하였다. 즉 YMT membrane을 이용하여주요 parameter를 산출하였다. 인체혈액에 대한 혈청단백결합율 측정은 ultrafiltration법을 이용하였다. 즉 YMT membrane을 이용하여 유리약물을 분리하여 HPLC로 정량하였다. 결과 및 고찰: 1. KR 53170 10mg/kg 정맥투여시 최고혈중농도는 0.55ug/ml, 반감기는 0.51hr, 분포용적은 4.5L이었다. 20mg/kg를 경구 투여시 최고 혈중농도는 0.18ug/ml, 반감기는 3.5기산이고 AUC는 0.91ug.ml, 분포용적 28Lm, Ka 3.49$hr^{-1}$ 그리고 Cl는 5.5L/hr/kg이었다. 이는 투여용량에 비해 매우 적은량이 흡수되고 배설 된 것으로 약물이 혈액에 대한 용해도 문제에 기인하는 것으로 간주된다. 2. KR 53234 10mg/kg 정맥투여후의 최고혈중농도는 1.14ug/ml, 반감기는 0.50hr, 분포용적은 2.2L이었다. 20mg/kg 경구 투여시의 최소 혈중 농도는 0.33 ug/ml, 소실반감기는 1.5시간, AUC는 0.942ug.hr/ml, 분포용적 11L, Ka는 3.05 $hr^{-1}$ 그리고 Cl는 5.3L/hr/kg이었다. 이는 KR 53170에서와 같이 매우 적은량이 흡수되고 배설되었다. 3. KR 53170의 혈청단백 결합율은 5-500 ug/ml 범위에서 78.7-86.2%이었고 KR 53234의 혈청단백결합율은 5-100 ug/ml 범위에서 79.6-71.2%이었다.이었다.

  • PDF

A Study on the Correlations between Total Prostate Volume and Prostate Transition Zone Volume Assessed Using Blood and Ultrasound Tests: in the Healthy Korean Men in Thirties (혈액, 초음파 검사 결과를 이용한 전립선이행대용적의 상관관계 연구: 기초질환이 없는 30대를 대상으로)

  • Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.407-412
    • /
    • 2017
  • This study investigates the correlations between the total prostate volume (TPV), using the prostate specific antigen (PSA) and prostate specific antigen density (PSAD) as the blood test results and transrectal ultrasound (TRUS), and the prostate transition zone volume (PTZV), as well as variables such as age; the findings can be used as clinical indicators. A retrospective analysis was conducted on 68 healthy men in their 30s who underwent TRUS and PSA and PSAD blood tests from June 2007 to April 2016, with no history of treatment in their prostate. Siemens Acuson sequoia 512 and the probe Siemens EC-10C5 Endocavitary were used as the ultrasound equipment. For statistical analysis, SPSS 18.0 was used to calculate the standard deviation and mean of each variable; Pearson's correlation analysis was also performed. The descriptive statistics of the variables were $24.27{\pm}6.60$ for TPV, $6.99{\pm}6.60$ for PTZV, $2.12{\pm}2.76$ for PSA, and $0.281{\pm}0.1$ for PSAD. The coefficients of correlations between PTZV and variables were 0.831 for PSAD, 0.707 for TPV, 0.398 for age, and 0.118 for PSA. While PSA and age were positively correlated, PSAD and TPV were highly correlated. Therefore, PTZV of men in their 30s without underlying diseases can be predicted using PSAD and TPV.

Influence of Soil Bulk Density on Growth and Root Development of Populus alba × P. glandulosa (토양(土壤)의 물리적(物理的) 조건(條件)이 은수원사시나무(Populus alba × P. glandulosa)의 생장(生長) 및 근계발달(根系發達)에 미치는 영향(影響) - 용적중(容積重)을 중심(中心)으로 -)

  • Min, Ell Sik;Lee, Soo Wook
    • Journal of Korean Society of Forest Science
    • /
    • v.66 no.1
    • /
    • pp.45-53
    • /
    • 1984
  • This experiment has been made to find out the influence of soil bulk density on growth and root development of Populus alba ${\times}$ P. glandulosa in Buyeo-kun, Chungnam. Bulk density and porosity significantly change according to slope position and soil depth and have a significant effect on tree height, DBH, biomass, and the distribution of root development. The results extracted from the experiments are as follows; 1) Bulk density in average changes from $1.17g/cm^3$ (1.05 ~ 1.40) in lower slope position to $1.43g/cm^3$ (1.36 ~ 1.60) in upper slope position, and porosity from 52.65% (55.05 ~ 45.50) in lower slope position to 41.20% (43.81 ~ 37.21) in upper slope position. 2) Bulk density increases significantly with soil depth. 3) Tree height, DBH, and total biomass decrease with bulk density. 4) Foliage, branch, bolewood, bolebark, and root also significantly have a negative correlation with hulk density. 5) Populus alba ${\times}$ P. glandulosa has a shallow root system chiefly distributing only in AI horizon, and critical bulk density is $1.43g/cm^3$. Therefore, slope position, hulk density, and porosity are considered to influence on the growth, biomass, and root development of Populus alba ${\times}$ P. glandulosa.

  • PDF