• Title/Summary/Keyword: 용입체

Search Result 245, Processing Time 0.027 seconds

Three-Dimensional Dosimetry Using Magnetic Resonance Imaging of Polymer Gel (중합체 겔과 자기공명영상을 이용한 3차원 선량분포 측정)

  • Oh Young-Taek;Kang Haejin;Kim Miwha;Chun Mison;Kang Seung-Hee;Suh Chang Ok;Chu Seong Sil;Seong Jinsil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.264-273
    • /
    • 2002
  • Purpose : Three-dimensional radiation dosimetry using magnetic resonance imaging of polymer gel was recently introduced. This dosimetry system is based on radiation induced chain polymerization of acrylic monomers in a muscle equivalent gel and provide accurate 3 dimensional dose distribution. We planned this study to evaluate the clinical value of this 3-dimensional dosimetry. Materials and Methods: The polymer gel poured into a cylindrical glass flask and a spherical glass flask. The cylindrical test tubes were for dose response evaluation and the spherical flasks, which is comparable to the human head, were for isodose curves. T2 maps from MR images were calculated using software, IDL. Dose distributions have been displayed for dosimetry. The same spherical flask of gel and the same irradiation technique was used for film and TLD dosimetry and compared with each other. Results : The R2 of the gel respond linearly with radiation doses in the range of 2 to 15 Gy. The repeated dosimetry of spherical gel showed the same isodose curves. These isodose curves were identical to dose distributions from treatment planning system especially high dose range. In addition, the gel dosimetry system showed comparable or superior results with the film and TLD dosimetry. Conclusion : The 3-dimensional dosimetry for conformal radiation therapy using MRI of polymer gal showed stable and accurate results. Although more studies are needed for convenient clinical application, it appears to be a useful tool for conformal radiation therapy.

Name Review, and Production Method of Pyeongjeongmo, Housed by the National Palace Museum of Korea (국립고궁박물관 소장 평정모(平頂帽)의 명칭 검토와 제작방법)

  • Lee, Eun-Joo;Jin, Duk-Soon;Lee, Jeong-Min
    • Korean Journal of Heritage: History & Science
    • /
    • v.51 no.2
    • /
    • pp.4-21
    • /
    • 2018
  • This paper reviewed the legitimacy of the name of those sixteen pieces of hat artifacts known in Korean as pyeongjeongmo and currently housed by the National Palace Museum. This was undertaken in order to rectify the error of calling them pyeongjeongmo. Also, the paper suggested pyeongjeongmo's production method to apply representation of the artifacts or production of Joseon officials' hats as representation of ritual costumes in the royal court. The name pyeongjeongmo originated from pyeongjeonggeon. Gyeongguk Daejeon recorded that noksas wore yugak-pyeongjeonggeon and seoris wore mugak-pyeongjeonggeon, but the pyeongjeongmo artifacts housed in the National Palace Museum have been found irrelevant to those pyeongjeonggeons put on by both noksas and seoris. Rather, they has been confirmed as corresponding to dugeon or jogeon worn by byeolgams or suboks who served at the palace of the crown prince or princess. Through the investigation of the artifacts, the researchers could find out the tailoring and sewing methods, the finished look, and the folding manner of pyeongjeonggeon. Although the structure of pyeongjeonggeon was generally consistent, the frontal look was slightly different depending on the folding manner, resulting in three distinguished types of pyeongjeonggeon. Regardless, the pyeongjeongmo was made with one piece of fabric by a flat tailoring and folding method to create a three-dimensional hat. The finished shape appeared low in the front and high in the back side structure. The head girth was 55~59 cm, and the height was 19.4~21.5 cm. To make it with one piece of fabric, the head girth part was tailored in the same direction as the strands. Based on the artifact Changdeok 23820, this paper has also suggested a finished reproduction through the processes of preparing the materials, mounting, making the center ornaments, sewing and folding. The tailoring was completed with black silk fabric which was cut in a unique shape designed in advance, and hemp fabric which was mounted to the former. The top part of the head was finished with black threads, and the center line at the back was fixed with decolored cotton threads by blanket stitches with 3.5~4 cm intervals. Bamboo strands were inserted in the inside of the front-folded part, which then was fixed by patterned stitches with white cotton thread. At the back, a small bamboo clasp was attached so that one can lock it to the headband and prevent it from falling off.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

A Study on the morphologic characteristics of each constitution's trunk (체간부의 사상체질별 형태학적 특징에 관한 연구)

  • Hong, Suck-chull;Lee, Su-kyung;Lee, Eui-joo;Han, Gi-hwan;Chou, Yong-jin;Choi, Chang-seok;Koh, Byung-hee;Song, Il-byung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.10 no.1
    • /
    • pp.101-142
    • /
    • 1998
  • 1. Objects The base of classification of Sasang Constitution was the different congenital formation of organs such as lungs, spleen, liver, kidneys, and it was expanded from the viscera region of lungs, spleen, liver, kidneys to the body shape of trunk. The researched about body shape of Sasang Constitution have had points of issues which derived by measurement with hands. But this study was measured the characteristics of body shape putting in importance of anatomical position with the computerized 3-Dimension scanner, which minimized the errors of measurement, and it was abled the cubic measurement such as volume, area of cross section as well as round length. 2. Materials & Method The examinee was healthy male 40 persons and female 20 persons from 20's to 40's, who was diagnosed by the specialist of Sasang Constitutional Medicine. The body shape was measured round length, area of cross section, and volume of 31 anatomical points and the 25 hypothesis with the Rapid 3D Color Scanner Model 3030 RGB/PS. And the characteristics of each constitution's body shape was derived. 3. Results & Concousion In female, Taeumin had the largest trunk and Soeumin had the smallest trunk compared to other constitution, but Soyangin had only the smallest neck. Soeumin has the smallest round length of nipple and the $CV_{12}$, and Soyangin has the smallest breadth of ASIS. Soyangin had the smallest volume from thyroid bone to the highest points of armpits and from sternum to nipple. Taeumin had the largest volume from sternum to the $CV_{12}$ and from sternum to xiphoid process. In male, Taeumin had the largest trunk and Soeumin had the smallest trunk from the level of thyroid bone to ASIS. Soyangin has the longest distance and Soeumin has the shortest distance from nipple to the lowest of breast. Taeumin had the largest volume of trunk and Soeumin had the smallest volume of trunk. In the ration of four-Cho, Taeumin had the longest distance from the highest points of armpits to nipple and Soyangin had the shortest distance of that. Soyangin had the smallest ratio of the height of upper middle cho. Soeumin had the smallest ratio from the $CV_{12}$ to navel among trunk. In the correlation among the four Cho, Taeumin had the negative correlation between the Upper-Cho and the Lower-Middle-Cho significantly.

  • PDF

The Impact of Bladder Volume on Acute Urinary Toxicity during Radiation Therapy for Prostate Cancer (전립선암의 방사선치료시 방광 부피가 비뇨기계 부작용에 미치는 영향)

  • Lee, Ji-Hae;Suh, Hyun-Suk;Lee, Kyung-Ja;Lee, Re-Na;Kim, Myung-Soo
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.237-246
    • /
    • 2008
  • Purpose: Three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) were found to reduce the incidence of acute and late rectal toxicity compared with conventional radiation therapy (RT), although acute and late urinary toxicities were not reduced significantly. Acute urinary toxicity, even at a low-grade, not only has an impact on a patient's quality of life, but also can be used as a predictor for chronic urinary toxicity. With bladder filling, part of the bladder moves away from the radiation field, resulting in a small irradiated bladder volume; hence, urinary toxicity can be decreased. The purpose of this study is to evaluate the impact of bladder volume on acute urinary toxicity during RT in patients with prostate cancer. Materials and Methods: Forty two patients diagnosed with prostate cancer were treated by 3DCRT and of these, 21 patients made up a control group treated without any instruction to control the bladder volume. The remaining 21 patients in the experimental group were treated with a full bladder after drinking 450 mL of water an hour before treatment. We measured the bladder volume by CT and ultrasound at simulation to validate the accuracy of ultrasound. During the treatment period, we measured bladder volume weekly by ultrasound, for the experimental group, to evaluate the variation of the bladder volume. Results: A significant correlation between the bladder volume measured by CT and ultrasound was observed. The bladder volume in the experimental group varied with each patient despite drinking the same amount of water. Although weekly variations of the bladder volume were very high, larger initial CT volumes were associated with larger mean weekly bladder volumes. The mean bladder volume was $299{\pm}155\;mL$ in the experimental group, as opposed to $187{\pm}155\;mL$ in the control group. Patients in experimental group experienced less acute urinary toxicities than in control group, but the difference was not statistically significant. A trend of reduced toxicity was observed with the increase of CT bladder volume. In patients with bladder volumes greater than 150 mL at simulation, toxicity rates of all grades were significantly lower than in patients with bladder volume less than 150 mL. Also, patients with a mean bladder volume larger than 100 mL during treatment showed a slightly reduced Grade 1 urinary toxicity rate compared to patients with a mean bladder volume smaller than 100 mL. Conclusion: Despite the large variability in bladder volume during the treatment period, treating patients with a full bladder reduced acute urinary toxicities in patients with prostate cancer. We recommend that patients with prostate cancer undergo treatment with a full bladder.