• Title/Summary/Keyword: 용수재이용

Search Result 228, Processing Time 0.024 seconds

Design and Operation of the Rainwater-Greywater Hybrid System : SNU No. 39 Building (빗물-저농도 오수 하이브리드 시스템의 설계 및 운전 평가 : 서울대 39동)

  • Shim, In-tae;Park, Hyun-ju;Kim, Tschung-il;Jung, Sung-un;Han, Moo-young;Namkung, Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.12
    • /
    • pp.676-682
    • /
    • 2016
  • In this study, rainwater-greywater hybrid system was installed and operated for 1 year in order to evaluate its water quantity, water quality, and economic efficiency in building no. 39. This system was expected to overcome each disadvantages of and maximize each advantages. Low-greywater that was washed up from shower room was treated by MBR (Membrane Bioreactor) and ozone oxidation. Rainwater that was collected from the rooftop was stored in a reservoir, and then transferred to the storage tank that was mixed with treated greywater. After 1 year operating in building no. 39, rainwater and greywater was used to supply $2,599m^3$ of toilet flushing water. In terms of water quality, rainwater was satisfied far the greywater reuse standards except for E.coli. Moreover, low greywater quality was acceptable except for E. coli, BOD, SS, and turbidity. In addition, economic analysis was obtained from benefit-cost ratio (B/C) with 1.11. It implies that the feasibility of the project was reasonable. Furthermore, various research and policy to improve the economic efficiency of water recycling facilities is required to expand the use of water recycling facilities.

밀봉수주입 열교환기의 비정상 열전달 특성

  • 장근선;진승령;손용수
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.352-357
    • /
    • 1995
  • 원자력발전소 화학 및 체적제어계통의 일부인 밀봉수주입계통은 원자로 냉각재펌프 밀봉장치로 일정한 온도 범위의 밀봉수를 공급하여 밀봉장치의 건전성 및 원자로 냉각재 계통의 압력경계를 유지한다. 그러나 발전소 과도상태시 밀봉수 주입온도가 허용범위를 벗어나게 되면 온도조절기 폐쇄신호에 의해 밀봉장치로의 밀봉수 주입이 차단될 수 있다. 본 연구에서는 발전소 과도시에도 밀봉수 주입이 지속적으로 가능한 설계개선 방안으로 밀봉수주입 열교환기 주위에 우회라인을 설치하는 방안을 제시하고 밀봉수주입 열교환기 내에서의 비정상 열전달 현상을 수치해석을 이용하여 분석하였다. 계산은 속도장을 정상 상태인 power-law분포로 가정하고 시간 t=0에서 입구온도가 급격히 변하는 과도시 우회 유량 및 시간 변화에 대한 온도분포, 국부 Nusselt 수, 평균온도 등을 구하였다.

  • PDF

Treatment Characteristics of Rapid filtration Process treating Secondary Clarifier Effluent for Wastewater Reuse (처리수 재이용을 위한 최종침전지 유출수의 급속여과공정 처리특성)

  • Han, Dong-U
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.2
    • /
    • pp.213-220
    • /
    • 2002
  • This reserch was focused upon experimental study for wastewater reuse and conducted to evaluate optimum operating conditions of rapid filtration process such as filter flow rate, filtration time and backwashing condition for reuse of secondary-treated effluent using the pilot plant installed in real wastewater treatment plant. Also, the experiment on treatment char-acteristics of coagulant-added activated sludge process was performed to compare with activated sludge succeeded to rapid filtration. As the filtration velocity was 100m/day, the filtration time of the rapid filter connected with activated sludge system was revealed to 40 hours. Backwashing of filter was conducted by water wash and air scour. The optimum backwashing time and backwash flow rate were 10min and 10LPM, respectively. The quantity of backwashing water of the rapid filter was about 2% of total treated water.

The Effect of Reclaimed Sewage Irrigation on the Rice Cultivation (벼 재배시 생활오수 처리수 관개 효과)

  • Yoon, Chun-Gyeong;Kwun, Soon-Kuk;Chung, Ill-Min;Kwon, Tae-Young
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.3
    • /
    • pp.236-244
    • /
    • 1999
  • A feasibility study was performed to examine the agronomic application of treated sewage on paddy rice culture by field experiment. The domestic sewage was treated by the constructed wetland system which was in subsurface flow type and consisted of sand and macrophyte. The effluent of the wetland system was adjusted to maintain the total nitrogen concentration below $25mgL^{-1}$ and used for irrigation water. Four treatments include (1) irrigation of treated sewage after concentration adjusted with conventional fertilization (TWCF), (2) irrigation of treated sewage after concentration adjusted with half of the conventional fertilization (TWHF), (3) irrigation of treated sewage after concentration adjusted without fertilization (TWNF), and (4) irrigation of treated sewage as it was without fertilization (SWNF). These cases were compared to the control case of tap water irrigation with conventional fertilization (Control). Generally, addition of the treated sewage to the irrigation water showed no adverse affect on paddy rice culture, and even improvement was noticed in both growth and yields. TWCF showed the best result and the yields exceed the Control in about 10%. Overall performance of the treatments was TWCF, Control, TWHF, TWNF, and SWNF in decreasing order. From this study, it appears that reuse of treated sewage as a supplemental irrigation water could be feasible and practical alternative for ultimate sewage disposal which often causes water quality problem to the receiving water body. For full scale application, further study is recommended on the specific guidelines of major water quality components and public health.

  • PDF

Immobilization of Arsenic in Tailing using the Hydmgen-Peroxide (과산화수소를 이용한 광미중 비소의 불용화)

  • 정익재;최용수;박흥목
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.3
    • /
    • pp.67-75
    • /
    • 1999
  • It is difficult to remedy tailings and soils including arsenic because arsenic compounds show anionic behaviour in natural condition and have chemical diversity by Eh/pH. This study was carried out to develop immobilization method of arsenic and iron in tailings and soils into ferric arsenate using hydrogen peroxide. According to experimental results, concentrations of arsenic and iron extracted from tailing of closed Gubong mine were reduced up to 84% and 93%, respectively. in this experiment. arsenic concentration decreased with an increase of hydrogen peroxide dosage. It was also showed that only 10% of arsenic and 20% of iron were extracted from the re-extraction experiments. Therefore, soil and tailing remedied by this method will be able to maintain long-time stability.

  • PDF

Effects of Pre-Oxidation for Recirculation of Aquaculture Wastewater (양어용수 재이용을 위한 전 산화처리의 효과)

  • Lim, Jae-Lim;Shin, Hang-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.103-111
    • /
    • 2000
  • Ozonation and advanced oxidation($H_2O_2/O_3$) process were investigated under various experimental conditions to improve the efficiency of biological filter used for the treatment of recycled wastewater from aquaculture. Ammonia removal followed the first-order reaction whose reaction rate constant(k) was $2.0{\times}10^{-2}min^{-1}$ in ozonation. The ammonia removal rate increased according as the bicarbonate alkalinity is increased. About 46% $NH_3$ was oxidized by ozone at 200 mg/L as $CaCO_3$. When alkalinity existed in wastewater, ammonia removal rate by advanced oxidation was very low due to the inhibition effect of bicarbonate. However, when initial pH was adjusted to about 8.2 by 0.1 N KOH, ammonia removal rate was improved higher than that by ozonation. Especially. ammonia removal rate was the highest at $H_2O_2/O_3$ of 0.25 and about 90% of ammonia was removed in 30 min at this ratio as pH was maintained over 9. In the case of wastewater containing ammonia and organic constituents, ammonia removal efficiency by both ozonation and advanced oxidation decreased seriously because organic constituents consumed the oxidant faster than ammonia. In addition the optimal $H_2O_2/O_3$ ratio was changed. Like ammonia removal, DOC(dissolved organic carbon) increased for first 10 min and then decreased slowly because the particulate organic constituents were oxidized rapidly and then produce DOC. Even when the ammonia concentration by twice, oxidation of DOC was not retarded.

  • PDF

Determination of Rainwater Storage Capacity for Supplying Upland Crops (밭 작물 용수 공급을 위한 빗물저류조 용량 결정)

  • Hwang, Ju Ha;Maeng, Seung Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.53-53
    • /
    • 2019
  • 최근 지구온난화로 인한 기상 이변의 이유로 우리나라뿐만 아니라 세계 여러 국가에서 홍수 및 가뭄이 빈번하게 발생하고 있다. 특히 우리나라에서는 게릴라성 호우가 빈번히 발생하여 저지대 및 많은 지역에서 홍수가 발생하고 있으며, 연평균 총 강우량은 매년 비슷하나 게릴라성 호우와 같은 폭우의 빈도가 증가되고 있어 상대적으로 과거에 비해 가뭄의 발생기간도 길어지는 실정이다. 다시 말하면 게릴라성 호우와 같은 폭우는 잦아졌지만 강수량 자체는 감소하는 추세이다. 이는 홍수와 가뭄의 위험이 더 커졌다는 것을 의미한다. 이에 우리지역의 전체 물 이용 및 관리의 효율화가 필수적이며, 물 이용량의 약 50%를 차지하는 농업용수의 효율적 이용 및 관리가 중요하다. 따라서 본 연구에서는 관개기에 필요한 물이 얼마나 사용이 되는지에 대한 작물의 생육시기별 필요수량을 산정하고, 산정된 필요수량의 갈수빈도분석을 실시하고자 한다. 갈수빈도분석을 통해 재현기간에 따른 작물의 순별 필요수량 따라 저류조에 유입되는 빗물의 양으로 얼마만큼 해결이 되는지 확인하여 빗물의 사용량을 산정하여 저류조의 적정 용량을 검토하고자 한다. 작물계수를 이용하여 작물별 필요수량은 HOMWRS 프로그램을 이용하여 산정하며, 작물별 생육시기에 따른 필요수량에 대한 갈수빈도분석은 수문 통계 분석과 적합도 검정을 통하여 GUM, PT3, GEV, GLO, GPA 및 GNO분포를 대상으로 적정 분포를 선정한다. 선정된 분포형을 통해 재배작물별 생육시기에 따른 필요수량 계열의 설계 필요수량을 산정한다. 이에 따른 필요수량과 갈수빈도분석 결과를 통해 재배작물의 순별 수요량을 추정한다. 재배작물의 순별 물 수요와 잠재적인 저류조의 높이를 통해 빗물을 얼마만큼 재이용할 수 있는지에 대한 수용 비율(sufficiency ratio)을 산정하고. 순별 수요량에 따른 밭 작물의 적정 빗물 저류조 용량을 결정하는 방법을 제시하고자 한다.

  • PDF

Wastewater Reuse in Textile Industry: Case of Bandung, Indonesia (섬유공장폐수 재이용 사례: 인도네시아 반둥을 대상으로)

  • Chung, Youngkun;Lee, Mi-Young;Yang, Shi Chun;Kang, Seoktae
    • Journal of Appropriate Technology
    • /
    • v.5 no.1
    • /
    • pp.18-24
    • /
    • 2019
  • Citarum river in West Java, Indonesia plays strategic roles for Jakarta metropolitan areas. Besides it provides major source of water supply such as domestics and drinking water including Jakarta, it also provides water for hundreds of industries through its cascade reservoirs. However, recently, Citarum river basin has been seriously suffering from water and groundwater pollution as well as the lowering-down of groundwater level due to the extreme use of water resources in dry season by domestic and industrial activities. This project objectives are design and installation of industrial wastewater treatment/recycle facilities to overcome the problem of water pollution and the lowering-down of groundwater level in Bandung. For these, cyclone type dissolved air flotation (DAF), CYFLOAT, was successfully installed as the appropriate technology for the target textile industry with 100 ton/day of capacity. The CYFLOAT system can remove the 96.8% of particulates, which are known as a critical factor to recycle the wastewater, within 40 min of residence time. Furthermore, The CYFLOAT system can reduce the operational cost and land use. The project was carried out in strong partnership with local institute including UNPAR, IBT, and PUSKIM for the sustainability of the technology to textile industry complex in Indonesia.

Photoreactivation Study of Wastewater Treatment Effluent Disinfected by UV-disinfection for Water Reuse (용수재이용을 위한 하수처리 유출수의 UV 소독 후 광회복 조사)

  • 윤춘경;정광욱;함종화;전지홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.3
    • /
    • pp.84-93
    • /
    • 2003
  • Photoreactivation of microorganism following UV-disinfection is one of the research topics of interest in assessing the UV-disinfection performance. Apparent photoreactivation was examined under fluorescent lamp and solar radiation as well as in darkness. Total coliform, fecal coliform, and Escherichia coli were used as indicator microorganisms, and their concentration was monitored with time after UV-disinfection. Under the darkness, their initial concentration of 10∼30 MPN/100 mL increased to the level of 100 MPN/100 mL after 24 hours, which implied that part of damaged microorganisms by UV-disinfection might be repairable with time. Under the fluorescent lamp, photoreactivation was more apparent that their concentration increased up to 1,000 MPN/100 mL which might significantly impair the water uses specially in reuse of reclaimed wastewater. However, their concentration further decreased down to below 2 MPN/100 mL under the solar radiation primarily due to additional disinfection by solar radiation rather than photoreactivation. Samples not disinfected by UV-disinfection also demonstrated substantial decrease of their concentration under solar radiation from about 5,000 MPN/100 mL to less than 30 MPN/100 mL in 24 hours. But direct reuse of effluent without disinfection is not recommended because natural decay by solar radiation may take time and be affected by climatic conditions. The result suggests that photoreactivation of pathogenic microorganisms may not be concerned in agricultural reuse of reclaimed wastewater because solar radiation may provide further disinfection after UV-disinfection.

Feasibility Study of UV-Disinfection for Water Reuse of Effluent from Wastewater Treatment Plant (용수재이용을 위한 하수처리 유출수의 UV 소독 효율 연구)

  • 윤춘경;정광욱;함종화;전지홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.126-137
    • /
    • 2003
  • The feasibility study of UV-disinfection system was performed for disinfection of effluent from wastewater treatment plant. Three low-pressure UV lamps of 17, 25, and 41 W were examined with various flow rates. Low-pressure UV lamps of 17W were examined with various turbidity, DOM (dissolved organic matter), and SS (suspended solid). The pilot plant was a flow-through type UV-disinfection system, and the range of exposure time varied from 5 to 40 seconds, turbidity from 0 to 40 NTU, DOM from 0 to 30 mg/L, and SS from 10 to 40 mg/L. The 41W lamp demonstrated complete disinfection showing no survival ratio in all the experimental conditions, and generally 17W and 25W lamps also showed high removal ratio over 97%. For the same UV dose (UV intensity times exposure time), high intensity-short exposure conditions showed better disinfection efficiency than low intensity-long exposure conditions. While the effects of turbidity and DOM were not apparent, the effects of SS was significant on the disinfection efficiency which indicates that SS control before UV-disinfection appears to be necessary to increase removal efficiency. Considering characteristics of effluent from existing wastewater treatment plants, cost-effectiveness, stable performance, and minimum maintenance, the flow-through type UV-disinfection system with high intensity and low-pressure lamps was thought to be a competitive disinfection system for wastewater reclamation.