• Title/Summary/Keyword: 용량 추정

Search Result 555, Processing Time 0.029 seconds

Maximum Tolerated Dose Estimation by Stopping Rule and SM3 Design in a Phase I Clinical Trial (제 1상 임상시험에서 멈춤 규칙과 SM3 디자인을 이용한 최대허용용량 추정법)

  • Kim, Byoungchan;Kim, Dongjae
    • The Korean Journal of Applied Statistics
    • /
    • v.27 no.1
    • /
    • pp.13-20
    • /
    • 2014
  • Phase I Clinical Trials estimate a Maximum Tolerated Dose(MTD). In this paper, an MTD estimation method applied stopping rule is proposed for Phase I Clinical Trials. The suggested MTD estimation method is compared to the Continual Reassessment Method(CRM) method using a Monte Carlo simulation study.

Adjusted maximum tolerated dose estimation by stopping rule in phaseⅠclinical trial (제 1상 임상시험에서 멈춤 규칙을 이용한 수정된 최대허용용량 추정법)

  • Park, Ju Hee;Kim, Dongjae
    • Journal of the Korean Data and Information Science Society
    • /
    • v.23 no.6
    • /
    • pp.1085-1091
    • /
    • 2012
  • Phase I clinical trials are designed to identify an appropriate dose; the maximum tolerated dose, which assures safety of a new drug by evaluating the toxicity at each dose-level. The adjusted maximum tolerated dose estimation is presented by stopping rule in phase I clinical trial on this research. The suggested maximum tolerated dose estimation is compared to the standard method3 and NM method using a Monte Carlo simulation study.

Study on Analysis of Performance to Surrogate modeling Method for Battery State Estimation (리튬이온 배터리 상태 추정을 위한 근사모델링 방법과 그 성능 분석을 통한 수명 예측에 대한 연구)

  • Kang, Deokhun;Lee, Pyeng-Yeon;Jang, Shinwoo;Kim, Jonghoon
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.206-207
    • /
    • 2019
  • 리튬이온 배터리의 상태를 모니터링 하는 방법에 있어서, 대표적으로 배터리의 충전 상태(SOC)와 배터리의 건강 상태(SOH)를 추정하여 상태 지표로 사용된다. 본 연구에서는 리튬 이온 배터리의 상태 지표를 위한 용량 정보의 추정을 데이터 기반의 근사 모델을 이용하여 수행하였다. 다양한 근사 모델링 방법을 적용하여 추정되는 용량 정보를 비교하고, 모델링 방법에 따른 용량 추정 성능을 확인하였다. 또한, 이를 바탕으로 리튬이온 배터리의 용량을 예측하고 예측 성능을 분석하였다. 본 연구를 통하여 근사모델을 이용하는 경우, 리튬이온 배터리의 용량 추정은 물론 예측을 수행하는 방법으로서의 활용 가능성을 확인하였으며, 또한 제안하는 방법을 이용하여 보유하고 있는 모니터링 데이터를 활용하여 리튬이온 배터리의 성능을 평가하는데 있어 효과적으로 활용될 수 있을 것으로 판단된다.

  • PDF

Simultaneous Estimation of State of Charge and Capacity using Extended Kalman Filter in Battery Systems (확장칼만필터를 활용한 배터리 시스템에서의 State of Charge와 용량 동시 추정)

  • Mun, Yejin;Kim, Namhoon;Ryu, Jihoon;Lee, Kyungmin;Lee, Jonghyeok;Cho, Wonhee;Kim, Yeonsoo
    • Korean Chemical Engineering Research
    • /
    • v.60 no.3
    • /
    • pp.363-370
    • /
    • 2022
  • In this paper, an estimation algorithm for state of charge (SOC) was applied using an equivalent circuit model (ECM) and an Extended Kalman Filter (EKF) to improve the estimation accuracy of the battery system states. In particular, an observer was designed to estimate SOC along with the aged capacity. In the case of the fresh battery, when SOC was estimated by Kalman Filter (KF), the mean absolute percentage error (MAPE) was 0.27% which was smaller than MAPE of 1.43% when the SOC was calculated by the model without the observer. In the driving mode of the vehicle, the general KF or EKF algorithm cannot be used to estimate both SOC and capacity. Considering that the battery aging does not occur in a short period of time, a strategy of periodically estimating the battery capacity during charging was proposed. In the charging mode, since the current is fixed at some intervals, a strategy for estimating the capacity along with the SOC in this situation was suggested. When the current was fixed, MAPE of SOC estimation was 0.54%, and the MAPE of capacity estimation was 2.24%. Since the current is fixed when charging, it is feasible to estimate the battery capacity and SOC simultaneously using the general EKF. This method can be used to periodically perform battery capacity correction when charging the battery. When driving, the SOC can be estimated using EKF with the corrected capacity.

Maximum Tolerated Dose Estimation with Dose De-Escalation Design in a Phase I Clinical Trials (제 1상 임상시험에서 용량 감량을 허용하는 MTD 추정법)

  • Jang, Eunah;Kim, Dongjae
    • The Korean Journal of Applied Statistics
    • /
    • v.27 no.7
    • /
    • pp.1115-1123
    • /
    • 2014
  • The main purpose of phase I clinical trials is to estimate the Maximum Tolerated Dose (MTD), which minimizes side effect and assures safety of a new drug by evaluating the toxicity at each dose-level. The conventional MTD estimation methods is Standard method (Storer, 1989; Korn et al., 1994), Accelerated Titration Designs (Simon et al., 1997) and DM method (Dixon and Mood, 1948) etc. In this paper, MTD estimation method with de-escalation is suggested phase I clinical trials. The proposed MTD estimation method is compared to Accelerated Titration Designs, SM3 without de-escalation method and SM3 with de-escalation method using a Monte Carlo simulation.

호처리 용량

  • Im, Ju-Hwan
    • ETRI Journal
    • /
    • v.8 no.2
    • /
    • pp.159-166
    • /
    • 1986
  • 본고는 TDX-1 의 호처리 용량에 관한 것으로 우선 전자교환기에 있어서 일반적인 호처리 용량 측정 방법에 대해 설명하고, LCS(Local Call Simulator)를 이용하여 측정에 의한 결과를 토대로 TDX-1의 호처리 용량을 산출한 결과 135,000BHCA로 추정됨을 밝힌다. RSS의 경우는 시스팀 구성에 따라 7,200~24,000BHCA로 추정된다.

  • PDF

Online State-of-Charge Estimation Algorithm Using Proportional-Integral Observer (비례적분 관측기를 이용한 실시간 잔존용량 추정 알고리즘)

  • Kim, Nari;Ahn, Jung-Hoon;Lee, Byung-Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.13-14
    • /
    • 2015
  • 본 논문은 추정 정확도를 높이기 위해 비례적분 관측기를 이용한 실시간 잔존용량 추정 알고리즘을 제안한다. 시뮬레이션을 통해 제안하는 알고리즘의 타당성을 검증하였고, 초기 잔존 용량이 불명확하거나 배터리 모델 파라미터 값이 실제와 일치하지 않더라도 평균 추정오차는 0.3% 미만으로 확인되었다.

  • PDF

Effect of Channel Estimation Error on Capacity of MIMO Systems (MIMO 시스템의 채널 용량에 대한 채널 추정 오차의 영향 분석)

  • 함재상;심세준;이충용;박현철;홍대식
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.8
    • /
    • pp.63-68
    • /
    • 2004
  • The capacity of MIMO systems is numerically analyzed when channel estimation error exists. The analysis shows that the capacity is influenced by Mean Square Error (MSE) as well as average Signal to Noise Ratio (SNR). Furthermore, in this paper we present the standard selecting a channel estimator suitable to a system owing to get a tolerable channel estimation error in a given average SNR and channel capacity loss. The simulation results show that the tolerable MSEs for 1 bps/Hz capacity loss are about 10$^{-2}$ and 10$^{-4}$ at n dB and 40 dB average SNR, respectively.

A study on SOH estimation of Lithium-ion battery based on Bayesian Regression. (베이지안 회귀분석을 이용한 리튬이온 배터리의 SOH 추정 방법 연구)

  • Park, Seongyun;Kim, Jonghoon;Park, Sungbeak;Kim, Youngmi
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.53-55
    • /
    • 2019
  • 리튬 이온 배터리가 소형 모바일 기기, 전기 자동차, 에너지 저장장치 등에 상용화됨에 따라서 이의 충전 상태(SOC) 추정 및 셀, 모듈의 건전성(SOH)의 예측이 배터리 사용 기기의 관리 지표로 사용되고 있다. 리튬 이온 배터리는 여러 차례의 방전으로 노화되어 기기의 요구 부하를 공급가능한지 지표로 평가되어야 한다. 정확한 SOH 추정을 위해 리튬 이온 배터리의 방전 용량 실험이 주기적으로 진행되어야 하며, 이를 통해 오프라인 기반의 SOH 추정이 가능해진다. 본 논문에서는 베이지안 회귀분석 방법을 이용하여 오프라인 SOH 추정을 진행하기 위해 방전 용량을 추정하였으며, 고출력 배터리인 18650 25R셀을 이용하여 방전 용량 추정 결과 방전 전류 1 C-rate에서 1%, 2 C-rate에서 2%의 추정 오차율을 나타냈다.

  • PDF

SOH estimation method based on simple linear regression model for high power lithium ion battery (고출력 리튬이온 배터리에 적합한 단순선형회귀모형 기반 SOH 추정 기법)

  • Lee, Pyeong-Yeon;Park, Jin-Hyeong;Yoon, Chan-O;Kim, Jonghoon
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.246-248
    • /
    • 2018
  • 본 논문에서는 배터리 수명의 지표인 SOH(state of health) 추정 시 배터리 노화에 따라 방전 용량의 급격한 변화가 발생하면 SOH도 변화하게 된다. 이로 인해 잘못된 SOH의 정보를 가지고 오게 되며 배터리의 안정성 및 신뢰성에 문제가 된다. 본 논문에서는 방전 용량과 내부 저항의 선형적 관계를 확인하고, 방전 용량과 내부저항을 고려한 단순선형회귀모형(simple linear regression model)을 모델링하였다. 방전 용량의 급격한 변화나 오프라인 기반 방전 용량을 측정함에 어려움이 있는 경우 단순선형회귀모형에 따라 방전 용량을 추정하여 SOH를 보정하는 기법을 제안하고 이에 대한 검증을 수행하였다.

  • PDF