• Title/Summary/Keyword: 요오드조영제

Search Result 30, Processing Time 0.02 seconds

1H-NMR Analysis according to the Storage Period after the Use of Iopamidol and Ioversol Formulations Contrast Agents (Iopamidol과 Ioversol 제제 조영제의 사용 후 보관 기간에 따른 1H-NMR 분석)

  • Han, Beom-Hee
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.239-245
    • /
    • 2021
  • Since the side effects of contrast agents occur in many ways, hospitals must clearly identify the contrast agents and know how to manage them. Storage of contrast media It is common practice to store contrast media in a warm room to reduce viscosity and improve patient comfort. However, it is important to recognize that long-term storage at high temperatures can shorten the shelf life of a product. Therefore, in this study, the presence or absence of chemical changes according to the storage period after using the contrast medium was analyzed. As the analysis equipment, a 500 MHz Nuclear Magnetic Resonance Spectrometer of Bruker Avance (Germany) possessed by Korea Basic Science Institute (KOREA BASIC SCIENCE INSTITUTE; KBSI) was used. For the X-ray iodide contrast medium, Pamiray contrast medium of Iopamidol and Optiray contrast medium of Ioversol, samples remaining after 7 days, 20 days, 30 days, and 1 year were collected, By acquiring the spectrum from the 1H-NMR spectrometer of the contrast medium stimulated by It was compared and analyzed with the standard sample. In conclusion, depending on the storage period of the contrast medium, no peaks of physical and chemical changes were observed in both the Pamiray contrast medium of Iopamidol and the Optiray contrast medium of Ioversol after 7 days, 20 days, 30 days, and 1 year after use.

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF

Spectral CT Analysis of Hounsfield Unit (HU) according to MonoE (keV) and Dilution Ratio of the Contrast Agent: Use of Spectral CT (단색에너지(keV)와 조영제 희석비율 변화에 따른 HU(Hounsfield Unit)값 분석: Spectral CT 이용)

  • Jung, Hee-Ra;Kang, Jin-woo;Kwon, Oh-Jun;Kim, Ho-Jin;Jung, Dabin;Lee, Jae-Hyun;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.669-676
    • /
    • 2020
  • The purpose of this study was to analyze the changes in the values of Hounsfield Unit (HU) according to the changes in monoenergy (keV) and dilution ratio of the contrast agent, using the spectral CT. Spectral CT was used as the testing device, while 20 cc syringe phantom was used to set a total of six dilution ratios of the contrast agent: 8:2, 7:3, 6:4, 5:5, 4:6, and 3:7. Here, the non-ionic iodine solution (350 mg/ml) was used as a contrast agent. The syringe axial image was reconstructed by adjusting the obtained data on nine MonoE levels; 40 keV, 45 keV, 50 keV, 55 keV, 60 keV, 65 keV, 70 keV, 75 keV, and 80 keV. The HU values were measured at the three points of the reconstructed syringe axial image. The measurements were taken 1,620 times in total. In the analysis of the HU values according to the changes in keV and dilution ratio of the contrast agent, the highest and lowest HU values were obtained from dilution ratio 8:2 and dilution ratio 3:7, respectively, across every MonoE in the comparison of HU according to dilution ratio per MonoE (p<0.05), while the highest and lowest HU values were obtained from 40 keV and 80 keV, respectively, across all dilution ratios in the comparison of HU according to MonoE per dilution ratio (p<0.05). For the correlation per each parameter, a negative correlation of -15.014 ± 0.298 was found for HU per keV (R2=0.519) and a negative correlation of -61.372 ± 3.608 was found for HU per dilution ratio (R2=0.152) (p<0.05). To conclude, an increase in keV or dilution ratio of the contrast agent was shown to decrease the HU, and the findings in this study are anticipated to serve as the basic data in the research of HU-related parameters in Spectral CT.

Signal Change of Iodinated Contrast Agents in MR Imaging (요오드화 조영제가 MR영상에 미치는 신호 변화)

  • Jeong, HK;Kim, Seongho;Kang, Chunghwan;Lee, Suho;Yi, Yun;Kim, Mingi;Kim, Hochul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.131-138
    • /
    • 2016
  • In this study, we tried to analyze the influence of ICM(Iodinated Contrast Media) in MR imaging compare to GBCA(Gadolinium Based Contrast Agent), and as this result we discussed whether resonable or not the protocol which is MRI scan after enhanced CT scan without proper time interval in clinical field. For this research, we assembled two phantoms. which one was iodine and another one was gadolinium. We did test two phantoms in conventional MRI scan which is T1, T2, T2 FLAIR and 3D angio. After that, quantitative analysis was progressed. The results of study were as follow : SSI(Saline's Signal Intensity) was shown as each sequences 175, 1231, 333, 37 [a.u] at iodine. and 1297, 123, 757, 232 [a.u] was recorded at gadolinium. BDEPS(the Biggest Difference of EPS) was shown as each sequences 1297, 123, 757, 232 [a.u] at iodine and 793, 6, 1495, 365 [a.u] was recorded at gadolinium. At this time, EPS(Enhancement Percentage to Saline) was shown 641.1, -90.0, 127.3, 527% at iodine and 685.1, 99.4, 365.7, 1077.4% was recorded at gadolinium. BP(BDEPS's point) was shown 900, 900, 477, 900 mmol at iodine and 4, 0.2, 0.2, 40 mmol was recorded at gadolinium. CPSS(Change Point of SI to SSI) was shown 63, 423, 63, 29 mmol at iodine and each [50, 30], [4, 0.2], [4, 1], 0.2 mmol was recorded at gadolinium. According to this research, we could not only discover the fact that was iodine could effect on MR signal, but also the pattern is different as various sequences compare to gadolinium. Therefore, we expect useful diagnostic MR image in clinical field with this quantitative data for deciding protocol regarding MRI and CT scan order.

A Simulation Study on Image Quality of Virtual Monochromatic Image using Dual-energy Method (이중에너지 방법을 이용한 가상 단색 영상의 화질 시뮬레이션 연구)

  • Son, Ki-Hong;Lee, Soo-Yeul;Kim, Dae-Hong;Chung, Myung-Ae
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.553-558
    • /
    • 2022
  • The purpose of this work was a simulation study to evaluate the virtual monochromatic (VM) image quality of blood vessels compared to the monochromatic image. Dual-energy images were obtained based on the linear attenuation coefficients of five materials at 50 keV and 80 keV at low- and high-energies, respectively. A weighting factor is required to synthesize the VM image, and the liver and bone were used as basis materials to obtain the weighting factor. VM images were synthesized at energies ranging from 30 keV to 100 keV. Image quality was evaluated by Contrast to noise ratio (CNR) and noise by setting calcium and contrast medium as signals and blood as background. According to the results, the energies with the maximum CNR were 50 keV and 60 keV for calcium and contrast medium, respectively. The energies showing the minimum noise were 70 keV, 70 keV, and 60 keV in calcium, iodine contrast medium, and blood, respectively. The VM image can contribute to the improvement of diagnostic performance in CT examination because it can implement an image at the optimal energy that minimize noise and maximize CNR.

Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography - (소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 -)

  • Lee, Hee-Jung;Son, Soon-Yong;Lee, Won-Hong
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.279-286
    • /
    • 2005
  • Purpose : There are two modalities, those are small bowel series(SBS) and abdominal pelvic computed tomography(CT), for diagnosis of small bowel disease. The aim of this study is to lend radiological technologists who are doing the two modalities assistance in the understanding characteristic of disease by comparing the two results. Meterials and method : 284 patients were examined the two SBS and abdominal pelvic CT together from 1999 to 2003. 250 ml $BaSO_4$ suspension 40 w/v% and 600ml carboxy methyl cellulose 0.5 w/v% were used for SBS. Abdominal Pelvic CT was examined in one hour before taking 450 ml $BaSO_4$ suspension 1.5 w/v%. The CT scan was done in 72 sec after 150 ml contrast media injection. the used protocol was helical mode 5:5 mm pitch 1.375:1, speed 27.50, exposure 120 kv, 240 mA, tube rotation time 0.5 sec. the statistic analysis was conducted with statistical program SPSS 10 version with frequency and crossing analysis. P-value less than 0.05 were considered significant. Results : In the results of SBS, normal findings were 131 patients(46.1%), inflammatory bowel disease(IBD) 64(22.9%), ischemia+ileocolitis+vasculitis 22(7.7%), Obstruction+stricture 21(7.7%) and Others 45(15.9%). In the results of abdominal pelvic CT, normal findings were 103 patients(36.3%), inflammatory bowel disease 65(22.9%), wall thickening+lymphadenopathy 42(14.8%), Fluid collection 17(6%), and Others 57case(20%). The same results of the two were 130patients(45.8%). 30patients(10.6%) of normal finding in SBS were diagnosed as wall thickening+lymphadenopathy and IBD in CT, and 15patients(5.3%) of normal finding in CT were diagnosed as ischemia+ileocolitis+vasculitis, mass and IBD in SBS(p<0.05). Transit time delay was diagnosed in 10patients(3.5%) on only SBS, wall thickening+lymphadenopathy was diagnosed in 20patients(7%) in only CT(p<0.05). Conclusion : We think that proper examination method will be selected in the small bowel disease, if we understand the characteristics of the disease and method.

  • PDF

Risk Factors for Adverse Reactions to Iodinated Contrast Media in Computed Tomography (컴퓨터 단층촬영을 위한 요오드화 조영제 사용으로 인한 부작용 발생의 위험인자 연구)

  • Kang, Hyung Rim;Lee, Yu Jeung
    • Korean Journal of Clinical Pharmacy
    • /
    • v.26 no.1
    • /
    • pp.40-45
    • /
    • 2016
  • Objective: The increasing use of imaging examinations such as computed tomography (CT) results in increased contrast media use, which increases contrast media-induced adverse reactions (AR). This study investigated the risk factors of ARs to nonionic iodinated contrast media. Methods: This study evaluated patients who were administered iodinated contrast media during CT scanning in Yeouido St. Mary's Hospital in Seoul, Korea in 2012. Among the subjects, those with contrast media-induced ARs were classified as the AR group. The control group included individuals without ARs who were selected through simple random sampling. The effects of sex, age, contrast media type and dose, CT region, previous contrast media administration, allergy history, and comorbidity were analyzed in the AR and control groups. Results: Multivariate logistic regression analyses were performed to evaluate the identified AR risk factors in 103 subjects in the AR group and 412 subjects in the control group. The results confirmed that the risk of developing ARs was significantly higher in females [odds ratio (OR): 2.206; 95% confidence interval (CI): 1.353-3.598], in individuals administered Iohexol (OR: 9.981; 95% CI: 2.361-42.193), in individuals with an allergy history (OR: 3.982; 95% CI: 1.742-9.101), and in individuals with comorbid asthma (OR: 6.619; 95% CI: 1.377-31.826). Most of the ARs were mild and immediate. Conclusion: In patients who were administered contrast media during CT scans, female gender, Iohexol use, allergy history, and asthma were risk factors for ARs. Therefore, special care is required for patients with such risk factors to prevent ARs.

Fundamental Study of Relative Measurement for Accurate Measurement of Stent Size in Computed Tomography Angiography (컴퓨터단층 혈관조영술에서 스텐트 사이즈의 정확한 측정을 위한 상대적 측정법의 기초연구)

  • Lee, Seung-Young;Hong, Joo-Wan;Kang, Su-Mi;Kim, Su-Bin;Joon, Sang-Hoon;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.713-720
    • /
    • 2019
  • The purpose of this study was to propose a new measurement method for accurate measurement of vessel diameter in computed tomography angiography(CTA). CTA test was performed after non-ionic iodine contrast agent was flowed at a constant rate to self-maded perfusion phantom. After obtaining raw data, images were reconstructed with multi-planar reconstruction(MPR) and maximal intensity projection(MIP). Diameters of vascular models were measured for each technique. Relative and conventional measurements were then compared. The mean diameter of the vascular model was closer to the actual measurement when relative measurement was used compared to that when conventional measurement was used both in MPR and MIP. Relative measurements of MPR and MIP were closer to actual measurement than those of conventional measurement (34% VS, 24%, p<0.05). The relative measurement method proposed in this study was closer to the actual measurement than the conventional measurement method. However, both test methods were still larger than actual results. Therefore, further study of relative measurement method is needed using this study as basic data.

Comparison of Bone Volume Measurements Using Conventional Single and Dual Energy Computed Tomography (전산화단층영상검사에서 단일에너지와 이중에너지를 이용한 뼈 부피측정의 비교)

  • Kim, Yung-kyoon;Park, Sang-Hoon;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.253-259
    • /
    • 2017
  • The study examines changes in calcium volume on born by comparing two figures; one is measured by dual energy computed tomography(DECT) followed by applying variation in monochromatic energy selection(keV), material decomposition(MD), and material suppressed iodine(MSI) analysis, and the other is measured by conventional single source computed tomography(CSCT). For this study, based on CSCT images taken by using human mimicked phantom, 70, 100, 140 keV and MSI, MD material calcium weighting(MCW) and MD material iodine weighting(MIW) of DECT were applied respectively. Then calculated calcium volume was converted to Agatston score for comparison. Volume of human mimicked phantom was in inverse proportion to keV. The volume decreased while keV increased(p<0.05). The most similar DECT volumes were reconstructed at 70 keV, the difference was showed $35.8{\pm}12.2$ for rib, femur ($16.1{\pm}24.1$), pelvis($13.7{\pm}18.8$), and spine($179.0{\pm}61.8$). However, the volume of MSI was down for each organ; the volume of rib was 5.55%, femur(76.34%), pelvis(55.16%) and spine(87.58%). The volume of MSI decreased 55.9% for rib, femur(80.7%), pelvis(69.6%) and spine(54.2%) while MD MIW reduced for rib(83.51%), femur(87.68%), pelvis(86.64%), and spine(82.62%). With the results, the study found that outcomes were affected by the method which examiners employed. When using DECT, calcium volume of born dropped with keV increased. It also found that the most similar DECT images were reconstructed at 70 keV. The results of experiments implied that the users of MSI and MD should be cautious of errors as there are big differences in scores between those two methods.

Optimization of Processing Process for Functional Anchovy Fish Sauce in Addition with Raw Sea Tangle (다시마를 첨가한 기능성 멸치액젓 제조조건 확립)

  • Jeong, Min-Hong;Jeong, Woo-Young;Gyu, Hyeon-Jin;Jeong, Sang-Won;Park, Hun-Kyu;Cho, Young-Je;Shim, Kil-Bo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.25 no.6
    • /
    • pp.1408-1418
    • /
    • 2013
  • To investigate the quality properties of functional anchovy fish sauce added with raw sea tangle, 2%, 5%, and 10% (w/w) of sea tangle was added to 25% (w/w) salted anchovy and then fermented at $20^{\circ}C$. During fermentation period, the amino nitrogen contents were increased at all groups and the highest contents were at 450 days of fermentation with $11.99{\pm}0.08$, $12.51{\pm}0.08$, and $11.95{\pm}0.08mg/mL$ at 2%, 5%, and 10% addition of raw sea tangle, respectively. After later, the contents were keeping at a similar level. VBN contents were continuously increased until 270 days of fermentation with $208.10{\pm}3.50$, $210.00{\pm}4.10$, $215.15{\pm}1.50mg/100ml$ at 2%, 5%, 10% addition of raw sea tangle, respectively. Alginic acid recovery was gradually increased in fermentation duration, showed the highest concentration at 540 days of fermentation with 67.00, 67.25, 67.90% at 2%, 5% and 10% addition of raw sea tangle, respectively. Dietary fiber recovery was rapidly increased at the beginning of fermentation and then decreased slowly as the fermentation is progressed. The highest recovery was at 30 days with 18.7, 18.6, and 17.9%, and the lowest was at 360 days with 8.7 and 11.1% at 2 and 10% addition of raw sea tangle, respectively, and 450 days with 11.4% at 5% sea tangle. The lowest fucoidan contents were exhibited at 30 days of fermentation with 0.07% at both of 2% and 5% addition, and 90 days with 0.10% at 10% addtion of sea tangle. The highest fucoidan contents were 270 days showing 0.24, 0.25, and 0.23% at 2, 5, and 10% addition, respectively. All groups adding different sea tangle concentration were not significantly different at all properties. However, the newly developed products were sufficient to the standard guideline of Korea Food Drug Adminstration. The best processing process of functional anchovy fish sauce in addition with raw sea tangle is 2% addition of raw sea tangle and fermented more than 450 days. The results obtained in this study indicated that the fish sauce added with sea tangle is superior in taste, functions to traditional fish sauce and could be competitive fishery fermented food.